scholarly journals Transvalvular Volume Flow Rate: A Useful Tool for Assessment of Aortic Valve Stenosis in Preserved Ejection Fraction Patients

Cardiology ◽  
2018 ◽  
Vol 141 (1) ◽  
pp. 69-70 ◽  
Author(s):  
Chris J. Kapelios ◽  
Maria Bonou ◽  
John Barbetseas
2010 ◽  
Vol 103 (4) ◽  
pp. 227-235 ◽  
Author(s):  
Sylvestre Maréchaux ◽  
Émilie Carpentier ◽  
Marie Six-Carpentier ◽  
Philippe Asseman ◽  
Thierry H. LeJemtel ◽  
...  

Cardiology ◽  
2018 ◽  
Vol 141 (1) ◽  
pp. 37-45 ◽  
Author(s):  
Dragos Alexandru ◽  
Simcha Pollack ◽  
Florentina Petillo ◽  
J. Jane Cao ◽  
Eddy Barasch

Objectives: To substitute the stroke volume index (SVi) with flow rate (FR) in the hemodynamic classification of severe aortic stenosis (AS) with preserved ejection fraction (EF), in order to evaluate its prognostic value. Methods: A total of 529 patients (78.8 ± 9.8 years old, 44.1% males) with isolated severe AS (aortic valve area, AVA < 1 cm2), EF ≥50%, in sinus rhythm, who underwent transthoracic echocardiography, were stratified by FR (≥/< 200 mL/s) and mean pressure gradient (MG) (≥/< 40 mm Hg): FRnormal/MGhigh, FRlow/MGhigh, FRnormal/MGlow, and FRlow/MGlow. Results: Aortic valve replacement was more frequently performed in the FRnormal/MGhigh than in the FRlow/MGlow group (69.3 vs. 47%, respectively, p < 0.0001), yielding a similar survival benefit across all four groups. Over a median follow-up of 51 ± 29 months, there were 249 deaths. In highly adjusted models, the FRlow/MGlow group had a higher all-cause mortality (HR = 1.7, 95% CI: 1.1–2.6, p = 0.02) than patients with FRnormal/MGhigh. FR had a stronger association with AVA than SVi (r = 0.51 vs. 0.41, respectively, p = 0.0002), and a similar predictive value for death (AUC = 0.57 and 0.58, respectively, p = 0.88). Conclusions: The FRlow/MGlow subset of AS is associated with the worst prognosis, and FR is not superior to SVi in the hemodynamic classification of severe AS.


2013 ◽  
Vol 66 (4) ◽  
pp. 255-260
Author(s):  
Cristina González-Cánovas ◽  
Carmen Muñoz-Esparza ◽  
María J. Oliva ◽  
Josefa González-Carrillo ◽  
Ángel López-Cuenca ◽  
...  

Author(s):  
Joe A. Mascorro ◽  
Gerald S. Kirby

Embedding media based upon an epoxy resin of choice and the acid anhydrides dodecenyl succinic anhydride (DDSA), nadic methyl anhydride (NMA), and catalyzed by the tertiary amine 2,4,6-Tri(dimethylaminomethyl) phenol (DMP-30) are widely used in biological electron microscopy. These media possess a viscosity character that can impair tissue infiltration, particularly if original Epon 812 is utilized as the base resin. Other resins that are considerably less viscous than Epon 812 now are available as replacements. Likewise, nonenyl succinic anhydride (NSA) and dimethylaminoethanol (DMAE) are more fluid than their counterparts DDSA and DMP- 30 commonly used in earlier formulations. This work utilizes novel epoxy and anhydride combinations in order to produce embedding media with desirable flow rate and viscosity parameters that, in turn, would allow the medium to optimally infiltrate tissues. Specifically, embeding media based on EmBed 812 or LX 112 with NSA (in place of DDSA) and DMAE (replacing DMP-30), with NMA remaining constant, are formulated and offered as alternatives for routine biological work.Individual epoxy resins (Table I) or complete embedding media (Tables II-III) were tested for flow rate and viscosity. The novel media were further examined for their ability to infilftrate tissues, polymerize, sectioning and staining character, as well as strength and stability to the electron beam and column vacuum. For physical comparisons, a volume (9 ml) of either resin or media was aspirated into a capillary viscocimeter oriented vertically. The material was then allowed to flow out freely under the influence of gravity and the flow time necessary for the volume to exit was recored (Col B,C; Tables). In addition, the volume flow rate (ml flowing/second; Col D, Tables) was measured. Viscosity (n) could then be determined by using the Hagen-Poiseville relation for laminar flow, n = c.p/Q, where c = a geometric constant from an instrument calibration with water, p = mass density, and Q = volume flow rate. Mass weight and density of the materials were determined as well (Col F,G; Tables). Infiltration schedules utilized were short (1/2 hr 1:1, 3 hrs full resin), intermediate (1/2 hr 1:1, 6 hrs full resin) , or long (1/2 hr 1:1, 6 hrs full resin) in total time. Polymerization schedules ranging from 15 hrs (overnight) through 24, 36, or 48 hrs were tested. Sections demonstrating gold interference colors were collected on unsupported 200- 300 mesh grids and stained sequentially with uranyl acetate and lead citrate.


Author(s):  
Qianhao Xiao ◽  
Jun Wang ◽  
Boyan Jiang ◽  
Weigang Yang ◽  
Xiaopei Yang

In view of the multi-objective optimization design of the squirrel cage fan for the range hood, a blade parameterization method based on the quadratic non-uniform B-spline (NUBS) determined by four control points was proposed to control the outlet angle, chord length and maximum camber of the blade. Morris-Mitchell criteria were used to obtain the optimal Latin hypercube sample based on the evolutionary operation, and different subsets of sample numbers were created to study the influence of sample numbers on the multi-objective optimization results. The Kriging model, which can accurately reflect the response relationship between design variables and optimization objectives, was established. The second-generation Non-dominated Sorting Genetic algorithm (NSGA-II) was used to optimize the volume flow rate at the best efficiency point (BEP) and the maximum volume flow rate point (MVP). The results show that the design parameters corresponding to the optimization results under different sample numbers are not the same, and the fluctuation range of the optimal design parameters is related to the influence of the design parameters on the optimization objectives. Compared with the prototype, the optimized impeller increases the radial velocity of the impeller outlet, reduces the flow loss in the volute, and increases the diffusion capacity, which improves the volume flow rate, and efficiency of the range hood system under multiple working conditions.


2010 ◽  
Vol 7 (3) ◽  
pp. 169-176 ◽  
Author(s):  
S. K. Pandey ◽  
Dharmendra Tripathi

The paper presents an analytical investigation of the peristaltic transport of a viscous fluid under the influence of a magnetic field through a tube of finite length in a dimensionless form. The expressions of pressure gradient, volume flow rate, average volume flow rate and local wall shear stress have been obtained. The effects of the transverse magnetic field and electrical conductivity (i.e. the Hartmann number) on the mechanical efficiency of a peristaltic pump have also been studied. The reflux phenomenon is also investigated. It is concluded, on the basis of the pressure distribution along the tubular length and pumping efficiency, that if the transverse magnetic field and the electric conductivity increase, the pumping machinery exerts more pressure for pushing the fluid forward. There is a linear relation between the averaged flow rate and the pressure applied across one wavelength that can restrain the flow due to peristalsis. It is found that there is a particular value of the averaged flow rate corresponding to a particular pressure that does not depend on the Hartmann number. Naming these values ‘critical values’, it is concluded that the pressure required for checking the flow increases with the Hartmann number above the critical value and decreases with it below the critical value. It is also inferred that magneto-hydrodynamic parameters make the fluid more prone to flow reversal. The conclusion applied to oesophageal swallowing reveals that normal water is easier to swallow than saline water. The latter is more prone to flow reversal. A significant difference between the propagation of the integral and non-integral number of waves along the tube is that pressure peaks are identical in the former and different in the latter cases.


Author(s):  
Hyungki Shin ◽  
Junhyun Cho ◽  
Young-Jin Baik ◽  
Jongjae Cho ◽  
Chulwoo Roh ◽  
...  

Power generation cycle — typically Brayton cycle — to use CO2 at supercritical state as working fluid have been researched many years because this cycle increase thermal efficiency of cycle and decrease turbomachinery size. But small turbomachinery make it difficult to develop proto type Supercritical Carbon dioxide (S-CO2) cycle equipment of lab scale size. KIER (Korea Institute of Energy Research) have been researched S-CO2 cycle since 2013. This paper is about 60kWe scale and sub-kWe class turbo generator development for applying to this S-CO2 cycle at the lab scale. A design concept of this turbo-generator is to use commercially available components so as to reduce development time and increase reliability. Major problem of SCO2 turbine is small volume flow rate and huge axial force. High density S-CO2 was referred as advantage of S-CO2 cycle because it make small turbomachinery possible. But this advantage was not valid in lab-scale cycles under 100kW because small amount volume flow rate means high rotating speed and too small diameter of turbine to manufacture it. Also, high inlet and outlet pressure make huge axial force. To solve these problem, KIER have attempt various turbines. In this paper, these attempts and results are presented and discussed.


Sign in / Sign up

Export Citation Format

Share Document