scholarly journals Automatic segmentation of wrist bone fracture area by K-means pixel clustering from X-ray image

Author(s):  
Kwang Baek Kim ◽  
Doo Heon Song ◽  
Sang-Seok Yun

Early detection of subtle fracture is important particularly for the senior citizens’ quality of life. Naked eye examination from X-ray image may cause false negatives due to operator subjectivity thus computer vision based automatic detection software is much needed in practice.  In this paper, we propose an automatic extraction method for suspisious wrist fracture regions. We apply K-means in pixel clustering to form the candidate part of possible fracture from wrist X-ray image automatically. This method can recover previously detected patterned false cases with edge detection method after fuzzy stretching. The proposed method is successful in 16 out of 20 tested cases in experiment.

Materials ◽  
2020 ◽  
Vol 13 (20) ◽  
pp. 4517
Author(s):  
John D. Yeager ◽  
Lindsey A. Kuettner ◽  
Amanda L. Duque ◽  
Larry G. Hill ◽  
Brian M. Patterson

Microstructural characterization of composite high explosives (HEs) has become increasingly important over the last several decades in association with the development of high fidelity mesoscale modeling and an improved understanding of ignition and detonation processes. HE microstructure influences not only typical material properties (e.g., thermal, mechanical) but also reactive behavior (e.g., shock sensitivity, detonation wave shape). A detailed nondestructive 3D examination of the microstructure has generally been limited to custom-engineered samples or surrogates due to poor contrast between the composite constituents. Highly loaded (>90 wt%) HE composites such as plastic-bonded explosives (PBX) are especially difficult. Here, we present efforts to improve measurement quality by using single and dual-energy microcomputed X-ray tomography and state-of-the-art image processing techniques to study a broad set of HE materials. Some materials, such as PBX 9502, exhibit suitable contrast and resolution for an automatic segmentation of the HE from the polymer binder and the voids. Other composite HEs had varying levels of success in segmentation. Post-processing techniques that used commercially available algorithms to improve the segmentation quality of PBX 9501 as well as zero-density defects such as cracks and voids could be easily segmented for all samples. Aspects of the materials that lend themselves well to this type of measurement are discussed.


2016 ◽  
Vol 16 (01) ◽  
pp. 1650001 ◽  
Author(s):  
Oishila Bandyopadhyay ◽  
Bhabatosh Chanda ◽  
Bhargab B. Bhattacharya

In this paper, we introduce an efficient method for segmenting the bone region of an X-ray image from its surrounding muscles and tissues. Automated segmentation of the bone part in a digital X-ray image is a challenging problem because of its low contrast with the surrounding flesh. The presence of noise and spurious edges further complicates the segmentation. Most of the existing methods either suffer from noisy contour detection or need training samples for manual tuning of certain thresholding parameters. We propose a fully automated segmentation technique, which utilizes a variant of entropy measure of the image. This scheme has been shown to be useful for fast and efficient analysis of a wide class of human X-ray images including skull, chest, pelvic region and ortho-dental zones. In order to quantify the quality of segmentation, we propose a new metric called average contour distortion index (ACDI) based on certain neighborhood properties of the contour pixels. Experiments on several X-ray images reveal encouraging results compared to other approaches as evident from the ACDI metric. We also re-validate the quality of several segmented bone images using segmentation entropy quantitative assessment (SEQA), and boundary-based precision–recall profile. All three metrics establish the superiority of the proposed technique to prior art.


2020 ◽  
Author(s):  
Stuart Yeates

A brief introduction to acronyms is given and motivation for extracting them in a digital library environment is discussed. A technique for extracting acronyms is given with an analysis of the results. The technique is found to have a low number of false negatives and a high number of false positives. Introduction Digital library research seeks to build tools to enable access of content, while making as few as possible assumptions about the content, since assumptions limit the range of applicability of the tools. Generally, the broader the assumptions the more widely applicable the tools. For example, keyword based indexing [5] is based on communications theory and applies to all natural human textual languages (allowances for differences in character sets and similar localisation issues not withstanding) . The algorithm described in this paper makes much stronger assumptions about the content. It assumes textual content that contains acronyms, an assumption which is known to hold for...


2020 ◽  
Vol 86 (10) ◽  
pp. 18-22
Author(s):  
K. N. Vdovin ◽  
K. G. Pivovarova ◽  
N. A. Feoktistov ◽  
T. B. Ponamareva

Zinc sulfate is the main component in the composition of the acidic zinc plating electrolyte. Deviation in the electrolyte composition from the optimum content leads to destabilization of the electrolysis process and deteriorate the quality of the resulting zinc coating. The proper quality of a zinc coating obtained by galvanic deposition can be ensured only with timely monitoring and adjustment of the electrolyte composition. A technique of X-ray fluorescence determination of zinc (in terms of zinc sulfate) in an acidic zinc plating electrolyte is proposed. The study was carried out using an ARL Quant’X energy dispersive spectrometer (Thermo Fisher Scientific, USA) with a semiconductor silicon-lithium detector. The features of the spectrometer design are presented. The optimal parameters of excitation and detection of zinc radiation were specified when the electrolyte sample was diluted 1:1000. The ZnKα1 line was used as an analytical line. The plotted calibration graph is linear, the correlation coefficient being 0.999234. The results of zinc determination according to the developed method were compared with the data of the reference method of complexometric titration to prove the reliability of the procedure. The results are characterized by good convergence and accuracy. The proposed method of X-ray fluorescence zinc determination in a zinc plating electrolyte equals complexometric titration in the limiting capabilities and even exceeds the latter in terms of the simplicity of sample preparation and rapidity. The developed method of X-ray fluorescence determination of zinc is implemented in analysis of the electrolyte used in the continuous galvanizing unit at «METSERVIS LLC».


Author(s):  
Katherine V. Whittington

Abstract The electronics supply chain is being increasingly infiltrated by non-authentic, counterfeit electronic parts, whose use poses a great risk to the integrity and quality of critical hardware. There is a wide range of counterfeit parts such as leads and body molds. The failure analyst has many tools that can be used to investigate counterfeit parts. The key is to follow an investigative path that makes sense for each scenario. External visual inspection is called for whenever the source of supply is questionable. Other methods include use of solvents, 3D measurement, X-ray fluorescence, C-mode scanning acoustic microscopy, thermal cycle testing, burn-in technique, and electrical testing. Awareness, vigilance, and effective investigations are the best defense against the threat of counterfeit parts.


2015 ◽  
pp. 50-58
Author(s):  
Thi Dung Nguyen ◽  
Tam Vo

Background: The patients on hemodialysis have a significantly decreased quality of life. One of many problems which reduce the quality of life and increase the mortality in these patients is osteoporosis and osteoporosis associated fractures. Objectives: To assess the bone density of those on hemodialysis by dual energy X ray absorptiometry and to examine the risk factors of bone density reduction in these patients. Patients and Method: This is a cross-sectional study, including 93 patients on chronic hemodialysis at the department of Hemodialysis at Cho Ray Hospital. Results: Mean bone densities at the region of interest (ROI) neck, trochanter, Ward triangle, intertrochanter and total neck are 0.603 ± 0.105; 0.583 ± 0.121; 0.811 ± 0.166; 0.489 ± 0.146; 0.723 ± 0.138 g/cm2 respectively. The prevalences of osteoporosis at those ROI are 39.8%, 15.1%; 28%; 38.7%; and 26.9% respectively. The prevalences of osteopenia at those ROI are 54.8%; 46.3%; 60.2%; 45.2% and 62.7% respectively. The prevalence of osteopososis in at least one ROI is 52.7% and the prevalence of osteopenia in at least one ROI is 47.3%. There are relations between the bone density at the neck and the gender of the patient and the albuminemia. Bone density at the trochanter is influenced by gender, albuminemia, calcemia and phosphoremia. Bone density at the intertrochanter is affected by the gender. Bone density at the Ward triangle is influenced by age and albuminemia. Total neck bone density is influenced by gender, albuminemia and phosphoremia. Conclusion: Osteoporosis in patients on chronic hemodialysis is an issue that requires our attention. There are many interventionable risk factors of bone density decrease in these patients. Key words: Osteoporosis, DEXA, chronic renal failure, chronic hemodialysis


2021 ◽  
pp. 174751982098472
Author(s):  
Lalmi Khier ◽  
Lakel Abdelghani ◽  
Belahssen Okba ◽  
Djamel Maouche ◽  
Lakel Said

Kaolin M1 and M2 studied by X-ray diffraction focus on the mullite phase, which is the main phase present in both products. The Williamson–Hall and Warren–Averbach methods for determining the crystallite size and microstrains of integral breadth β are calculated by the FullProf program. The integral breadth ( β) is a mixture resulting from the microstrains and size effect, so this should be taken into account during the calculation. The Williamson–Hall chart determines whether the sample is affected by grain size or microstrain. It appears very clearly that the principal phase of the various sintered kaolins, mullite, is free from internal microstrains. It is the case of the mixtures fritted at low temperature (1200 °C) during 1 h and also the case of the mixtures of the type chamotte cooks with 1350 °C during very long times (several weeks). This result is very significant as it gives an element of explanation to a very significant quality of mullite: its mechanical resistance during uses at high temperature remains.


Geosciences ◽  
2021 ◽  
Vol 11 (4) ◽  
pp. 167
Author(s):  
Unai Cortada ◽  
María Carmen Hidalgo ◽  
Julián Martínez ◽  
María José de la Torre

The abandoned mining district of Linares (South Spain) is marked with waste from the mining and the processing of metal ores that pose an environmental hazard to watercourses. A combined analysis of waste, sediments and water was carried out to analyse the impact of a smelter on Baños Creek. The composition of the facility waste was determined using X-ray diffractometry and scanning electron microscopy. The total contents of the metal(loid)s in the waters and sediments of the watercourse were analysed, and sequential metal(loid) extraction of solid samples was carried out. The facility wastes consisted mainly of secondary minerals, such as natropharmacosiderite and spertiniite, as well as rare metal salts, such as mopungite and NaPb2(CO3)2(OH). The leachates generated by these wastes were highly alkaline, with a pH of 10 and a total dissolved solids concentration of approximately 9 g L−1. This Na-bicarbonate-type water had an As concentration above 200 mg L−1 and elevated levels of Pb, Sb and Zn (5029 µg L−1, 841 µg L−1 and 525 µg L−1, respectively). This highly contaminated lixiviate had a significant effect on the chemical quality of the waters and the bioavailability of metal(loid)s in the creek sediments, especially in the headwaters. In this zone, the As, Pb, Sb and Zn concentrations in the most mobile fraction of the sediments reached 1035 mg kg−1, 261 mg kg−1, 45 mg kg−1 and 30 mg kg−1, respectively. By comparison, smelter slag and mining waste have a much lower impact on the waters and the mobile fraction of the sediments, while significantly increasing the total concentration of these potentially toxic elements in creek sediments.


Sign in / Sign up

Export Citation Format

Share Document