scholarly journals Effects of different types of verbal encouragement on ankle force and muscle activity

2018 ◽  
Vol 32 (4) ◽  
pp. 699-708
Author(s):  
Ulisses T. Taddei ◽  
Francis Trombini-Souza ◽  
Jane S. S. P. Ferreira ◽  
Alessandra B. Matias ◽  
Rafael S. Inoue ◽  
...  

The aim of this study is to investigate (i) the effect of live and recorded verbal encouragement on muscle activity and ankle force; (ii) the effect of communication/extroversion on the variables; (iii) the reliability intra and inter examiners of the variables. Twenty healthy-youngers were assessed by surface electromyography of tibialis anterior and ankle flexion force by an ergometer twice, with one week apart. No difference was found between ankle force (p = 0.373) and root mean square values (RMS) (p = 0.207) for any of the conditions assessed on day 1 nor between examiners 1 and 2 for both live and recorded conditions in RMS (p = 0.207) and force (p = 0.373). Between the 1st and 7th days, there were no differences for any of the conditions on RMS (main effect “Day” p = 0.261, “condition” p = 0.568, interaction p = 0.936) or force (main effect“Day” p = 0.889, “condition” p = 0.781, interaction p = 0.961). Intraclass correlation coefficients (ICCs) for the ankle force were, for without verbal encouragement (ICC2, k = 0.880), live verbal encouragement of examiner 1 (ICC2, k = 0.870), and recorded verbal encouragement of examiner 1 (ICC2, k = 0.920). RMS without verbal encouragement condition (ICC2, k = 0.860), live verbal encouragement of examiner 1 (ICC2, k = 0.930) and recorded verbal encouragement of examiner 1 (ICC2, k = 0.920). Reproducibility between the two examiner’s live encouragements for ankle force (ICC3, k = 0.981) and RMS (ICC3, k = 0.920). There was no effect of the presence or type of the augmented feedback in RMS and ankle force. We conclude that verbal encouragement does not influence ankle torque or muscle activity and there is good to excellent intra and inter rater reliability for subjects’ performance regardless of verbal encouragement modality. In addition, we observed that psychological traits Communication and Emotional stability does not affect the subjects’ strength performance at the ankle.

2003 ◽  
Vol 83 (10) ◽  
pp. 899-906 ◽  
Author(s):  
Deborah Falla ◽  
Gwendolen Jull ◽  
Paul Dall'Alba ◽  
Alberto Rainoldi ◽  
Roberto Merletti

Abstract Background and Purpose. This study evaluated an electromyographic technique for the measurement of muscle activity of the deep cervical flexor (DCF) muscles. Electromyographic signals were detected from the DCF, sternocleidomastoid (SCM), and anterior scalene (AS) muscles during performance of the craniocervical flexion (CCF) test, which involves performing 5 stages of increasing craniocervical flexion range of motion—the anatomical action of the DCF muscles. Subjects. Ten volunteers without known pathology or impairment participated in this study. Methods. Root-mean-square (RMS) values were calculated for the DCF, SCM, and AS muscles during performance of the CCF test. Myoelectric signals were recorded from the DCF muscles using bipolar electrodes placed over the posterior oropharyngeal wall. Reliability estimates of normalized RMS values were obtained by evaluating intraclass correlation coefficients and the normalized standard error of the mean (SEM). Results. A linear relationship was evident between the amplitude of DCF muscle activity and the incremental stages of the CCF test (F=239.04, df=36, P<.0001). Normalized SEMs in the range 6.7% to 10.3% were obtained for the normalized RMS values for the DCF muscles, providing evidence of reliability for these variables. Discussion and Conclusion. This approach for obtaining a direct measure of the DCF muscles, which differs from those previously used, may be useful for the examination of these muscles in future electromyographic applications.


2015 ◽  
Vol 50 (4) ◽  
pp. 392-399 ◽  
Author(s):  
Enda Whyte ◽  
Aoife Burke ◽  
Elaine White ◽  
Kieran Moran

Context Deficits in dynamic postural control predict lower limb injury. Differing fatiguing protocols negatively affect dynamic postural control. The effect of high-intensity, intermittent exercise on dynamic postural control has not been investigated. Objective To investigate the effect of a high-intensity, intermittent exercise protocol (HIIP) on the dynamic postural control of men and women as measured by the Star Excursion Balance Test (SEBT). Design Descriptive laboratory study. Setting University gymnasium. Patients or Other Participants Twenty male (age = 20.83 ± 1.50 years, height = 179.24 ± 7.94 cm, mass = 77.67 ± 10.82 kg) and 20 female (age = 20.45 ± 1.34 years, height = 166.08 ± 5.83 cm, mass = 63.02 ± 6.67 kg) athletes. Intervention(s) We recorded SEBT measurements at baseline, pre-HIIP, and post-HIIP. The HIIP consisted of 4 repetitions of 10-m forward sprinting with a 90° change of direction and then backward sprinting for 5 m, 2 repetitions of 2-legged jumping over 5 hurdles, 2 repetitions of high-knee side stepping over 5 hurdles, and 4 repetitions of lateral 5-m shuffles. Participants rested for 30 seconds before repeating the circuit until they reported a score of 18 on the Borg rating of perceived exertion scale. Main Outcome Measure(s) A mixed between- and within–subjects analysis of variance was conducted to assess time (pre-HIIP, post-HIIP) × sex interaction effects. Subsequent investigations assessed the main effect of time and sex on normalized maximal SEBT scores. We used intraclass correlation coefficients to determine the test-retest reliability of the SEBT and paired-samples t tests to assess the HIIP effect on circuit times. Results We found a time × sex effect (F8,69 = 3.5; P range, <.001–.04; η2 range, 0.057–0.219), with women less negatively affected. We also noted a main effect for time, with worse normalized maximal SEBT scores postfatigue (F8,69 = 22.39; P < .001; η2 range, 0.324–0.695), and for sex, as women scored better in 7 SEBT directions (F8,69 = 0.84; P range, <.001–008; η2 range, 0.088–0.381). The intraclass correlation coefficients demonstrated high (0.77–0.99) test-retest repeatability. Paired-samples t tests demonstrated increases in circuit time post-HIIP (P < .001). Conclusions The HIIP-induced fatigue negatively affected normalized maximal SEBT scores. Women had better scores than men and were affected less negatively by HIIP-induced fatigue.


PeerJ ◽  
2019 ◽  
Vol 7 ◽  
pp. e8028
Author(s):  
Manuel López-Nicolás ◽  
José A. García-Vidal ◽  
Francesc Medina-Mirapeix ◽  
Joaquín P. Sánchez-Onteniente ◽  
Juan D. Berná Mestre ◽  
...  

Background The aim of this study was to evaluate the effect of different ergonomic supports on the muscle activity of two trunk muscles while a group of dentists performed a common dental procedure on a phantom head, divided into three tasks. Methods A one-way repeated measures study (ANOVA) was conducted on a group of 36 dentists. The middle trapezius and lumbar erector spinae muscles were measured with and without the use of different ergonomic supports (ergonomic stool, magnification lenses and both) using a portable surface electromyography (sEMG) device. Intraclass correlation coefficients (ICCs) and the absolute standard error of measurement (SEM) were used to establish the reliability of the baseline measures without ergonomic supports. Results The sEMG showed excellent ICCs (ranging from 0.92 to 0.99) and SEM. Bonferroni post hoc tests showed differences between the three ergonomic supports (p < 0.001) in both muscles studied. The lowest muscle activity measurement occurred with the isolated used of magnification lenses. The use of the ergonomic stool increased the muscle activity of the middle trapezius and lumbar erector spinae muscles to a greater extent than the magnification lenses. The combination of the ergonomic stool and the magnification lenses produced a different effect on each muscle.


1991 ◽  
Vol 34 (5) ◽  
pp. 989-999 ◽  
Author(s):  
Stephanie Shaw ◽  
Truman E. Coggins

This study examines whether observers reliably categorize selected speech production behaviors in hearing-impaired children. A group of experienced speech-language pathologists was trained to score the elicited imitations of 5 profoundly and 5 severely hearing-impaired subjects using the Phonetic Level Evaluation (Ling, 1976). Interrater reliability was calculated using intraclass correlation coefficients. Overall, the magnitude of the coefficients was found to be considerably below what would be accepted in published behavioral research. Failure to obtain acceptably high levels of reliability suggests that the Phonetic Level Evaluation may not yet be an accurate and objective speech assessment measure for hearing-impaired children.


Author(s):  
Marcos A Soriano ◽  
G Gregory Haff ◽  
Paul Comfort ◽  
Francisco J Amaro-Gahete ◽  
Antonio Torres-González ◽  
...  

The aims of this study were to (I) determine the differences and relationship between the overhead press and split jerk performance in athletes involved in weightlifting training, and (II) explore the magnitude of these differences in one-repetition maximum (1RM) performances between sexes. Sixty-one men (age: 30.4 ± 6.7 years; height: 1.8 ± 0.5 m; body mass 82.5 ± 8.5 kg; weightlifting training experience: 3.7 ± 3.5 yrs) and 21 women (age: 29.5 ± 5.2 yrs; height: 1.7 ± 0.5 m; body mass: 62.6 ± 5.7 kg; weightlifting training experience: 3.0 ± 1.5 yrs) participated. The 1RM performance of the overhead press and split jerk were assessed for all participants, with the overhead press assessed on two occasions to determine between-session reliability. The intraclass correlation coefficients (ICC) and 95% confidence intervals showed a high reliability for the overhead press ICC = 0.98 (0.97 – 0.99). A very strong correlation and significant differences were found between the overhead press and split jerk 1RM performances for all participants (r = 0.90 [0.93 – 0.85], 60.2 ± 18.3 kg, 95.7 ± 29.3 kg, p ≤ 0.001). Men demonstrated stronger correlations between the overhead press and split jerk 1RM performances (r = 0.83 [0.73-0.90], p ≤ 0.001) compared with women (r = 0.56 [0.17-0.80], p = 0.008). These results provide evidence that 1RM performance of the overhead press and split jerk performance are highly related, highlighting the importance of upper-limb strength in the split jerk maximum performance.


Dysphagia ◽  
2021 ◽  
Author(s):  
Sofie Albinsson ◽  
Lisa Tuomi ◽  
Christine Wennerås ◽  
Helen Larsson

AbstractThe lack of a Swedish patient-reported outcome instrument for eosinophilic esophagitis (EoE) has limited the assessment of the disease. The aims of the study were to translate and validate the Eosinophilic Esophagitis Activity Index (EEsAI) to Swedish and to assess the symptom severity of patients with EoE compared to a nondysphagia control group. The EEsAI was translated and adapted to a Swedish cultural context (S-EEsAI) based on international guidelines. The S-EEsAI was validated using adult Swedish patients with EoE (n = 97) and an age- and sex-matched nondysphagia control group (n = 97). All participants completed the S-EEsAI, the European Organization for Research and Treatment of Cancer Quality of Life Questionnaire-Oesophageal Module 18 (EORTC QLQ-OES18), and supplementary questions regarding feasibility and demographics. Reliability and validity of the S-EEsAI were evaluated by Cronbach’s alpha and Spearman correlation coefficients between the domains of the S-EEsAI and the EORTC QLQ-OES18. A test–retest analysis of 29 patients was evaluated through intraclass correlation coefficients. The S-EEsAI had sufficient reliability with Cronbach’s alpha values of 0.83 and 0.85 for the “visual dysphagia question” and the “avoidance, modification and slow eating score” domains, respectively. The test–retest reliability was sufficient, with good to excellent intraclass correlation coefficients (0.60–0.89). The S-EEsAI domains showed moderate correlation to 6/10 EORTC QLQ-OES18 domains, indicating adequate validity. The patient S-EEsAI results differed significantly from those of the nondysphagia controls (p < 0.001). The S-EEsAI appears to be a valid and reliable instrument for monitoring adult patients with EoE in Sweden.


Author(s):  
Jens Sörensen ◽  
Jonny Nordström ◽  
Tomasz Baron ◽  
Stellan Mörner ◽  
Sven-Olof Granstam ◽  
...  

Abstract Aim To develop a method for diagnosing left ventricular (LV) hypertrophy from cardiac perfusion 15O-water positron emission tomography (PET). Methods We retrospectively pooled data from 139 subjects in four research cohorts. LV remodeling patterns ranged from normal to severe eccentric and concentric hypertrophy. 15O-water PET scans (n = 197) were performed with three different PET devices. A low-end scanner (66 scans) was used for method development, and remaining scans with newer devices for a blinded evaluation. Dynamic data were converted into parametric images of perfusable tissue fraction for semi-automatic delineation of the LV wall and calculation of LV mass (LVM) and septal wall thickness (WT). LVM and WT from PET were compared to cardiac magnetic resonance (CMR, n = 47) and WT to 2D-echocardiography (2DE, n = 36). PET accuracy was tested using linear regression, Bland–Altman plots, and ROC curves. Observer reproducibility were evaluated using intraclass correlation coefficients. Results High correlations were found in the blinded analyses (r ≥ 0.87, P < 0.0001 for all). AUC for detecting increased LVM and WT (> 12 mm and > 15 mm) was ≥ 0.95 (P < 0.0001 for all). Reproducibility was excellent (ICC ≥ 0.93, P < 0.0001). Conclusion 15O-water PET might detect LV hypertrophy with high accuracy and precision.


Author(s):  
Igor Junio de Oliveira Custódio ◽  
Gibson Moreira Praça ◽  
Leandro Vinhas de Paula ◽  
Sarah da Glória Teles Bredt ◽  
Fabio Yuzo Nakamura ◽  
...  

This study aimed to analyze the intersession reliability of global positioning system (GPS-based) distances and accelerometer-based (acceleration) variables in small-sided soccer games (SSG) with and without the offside rule, as well as compare variables between the tasks. Twenty-four high-level U-17 soccer athletes played 3 versus 3 (plus goalkeepers) SSG in two formats (with and without the offside rule). SSG were performed on eight consecutive weeks (4 weeks for each group), twice a week. The physical demands were recorded using a GPS with an embedded triaxial accelerometer. GPS-based variables (total distance, average speed, and distances covered at different speeds) and accelerometer-based variables (Player Load™, root mean square of the acceleration recorded in each movement axis, and the root mean square of resultant acceleration) were calculated. Results showed that the inclusion of the offside rule reduced the total distance covered (large effect) and the distances covered at moderate speed zones (7–12.9 km/h – moderate effect; 13–17.9 km/h – large effect). In both SSG formats, GPS-based variables presented good to excellent reliability (intraclass correlation coefficients – ICC > 0.62) and accelerometer-based variables presented excellent reliability (ICC values > 0.89). Based on the results of this study, the offside rule decreases the physical demand of 3 versus 3 SSG and the physical demands required in these SSG present high intersession reliability.


2021 ◽  
Vol 11 (1) ◽  
Author(s):  
Minjeong Kim ◽  
Ja Young Oh ◽  
Seon Ha Bae ◽  
Seung Hyeun Lee ◽  
Won Jun Lee ◽  
...  

AbstractWe evaluated the reliability and validity of the 5-scale grading system to interpret the point-of-care immunoassay for tear matrix metalloproteinase (MMP)-9. Six observers graded red bands of photographs of the readout window in MMP-9 immunoassay kit (InflammaDry) two times with 2-week interval based on the 5-scale grading system (i.e. grade 0–4). Interobserver and intraobserver reliability were evaluated using intraclass correlation coefficients. The interobserver agreements were analyzed according to the severity of tear MMP-9 expression. To validate the system, a concentration calibration curve was made using MMP-9 solutions with reference concentrations, then the distribution of MMP-9 concentrations was analyzed according to the 5-scale grading system. Both intraobserver and interobserver reliability was excellent. The readout grades were significantly correlated with the quantified colorimetric densities. The interobserver variance of readout grades had no correlation with the severity of the measured densities. The band density continued to increase up to a maximal concentration (i.e. 5000 ng/mL) according to the calibration curve. The difference of grades reflected the change of MMP-9 concentrations sensitively, especially between grade 2 and 4. Together, our data indicate that the subjective 5-scale grading system in the point-of-care MMP-9 immunoassay is an easy and reliable method with acceptable accuracy.


Sensors ◽  
2021 ◽  
Vol 21 (9) ◽  
pp. 3065
Author(s):  
Ernest Kwesi Ofori ◽  
Shuaijie Wang ◽  
Tanvi Bhatt

Inertial sensors (IS) enable the kinematic analysis of human motion with fewer logistical limitations than the silver standard optoelectronic motion capture (MOCAP) system. However, there are no data on the validity of IS for perturbation training and during the performance of dance. The aim of this present study was to determine the concurrent validity of IS in the analysis of kinematic data during slip and trip-like perturbations and during the performance of dance. Seven IS and the MOCAP system were simultaneously used to capture the reactive response and dance movements of fifteen healthy young participants (Age: 18–35 years). Bland Altman (BA) plots, root mean square errors (RMSE), Pearson’s correlation coefficients (R), and intraclass correlation coefficients (ICC) were used to compare kinematic variables of interest between the two systems for absolute equivalency and accuracy. Limits of agreements (LOA) of the BA plots ranged from −0.23 to 0.56 and −0.21 to 0.43 for slip and trip stability variables, respectively. The RMSE for slip and trip stabilities were from 0.11 to 0.20 and 0.11 to 0.16, respectively. For the joint mobility in dance, LOA varied from −6.98–18.54, while RMSE ranged from 1.90 to 13.06. Comparison of IS and optoelectronic MOCAP system for reactive balance and body segmental kinematics revealed that R varied from 0.59 to 0.81 and from 0.47 to 0.85 while ICC was from 0.50 to 0.72 and 0.45 to 0.84 respectively for slip–trip perturbations and dance. Results of moderate to high concurrent validity of IS and MOCAP systems. These results were consistent with results from similar studies. This suggests that IS are valid tools to quantitatively analyze reactive balance and mobility kinematics during slip–trip perturbation and the performance of dance at any location outside, including the laboratory, clinical and home settings.


Sign in / Sign up

Export Citation Format

Share Document