The Influence of Force Direction on the Fracture Pattern and Fracture Resistance of Canine Teeth in Dogs

2017 ◽  
Vol 34 (1) ◽  
pp. 8-17 ◽  
Author(s):  
Stephanie Goldschmidt ◽  
Catherine Zimmerman ◽  
Caitlyn Collins ◽  
Scott Hetzel ◽  
Heidi-Lynn Ploeg ◽  
...  

Biomechanical studies of the elongated canine tooth of animals are few, and thus our understanding of mechanical and physical properties of animal teeth is limited. The objective of the present study was to evaluate the influence of force direction on fracture resistance and fracture pattern of canine teeth in an ex vivo dog cadaver model. Forty-five extracted canine teeth from laboratory beagle dogs were standardized by hard tissue volume and randomly distributed among 3 force direction groups. The teeth were secured within a universal testing machine and a load was applied at different directions based on testing group. The maximum force to fracture and the fracture pattern classification were recorded for each tooth. After correcting for hard tissue cross-sectional area in a multivariate analysis, no significant difference in the amount of force required for fracture was apparent between the different force direction groups. However, the influence of force direction on fracture pattern was significant. The results of this study may allow the clinician to educate clients on possible causal force directions in clinically fractured teeth and, thus, help prevent any contributing behavior in the future.

2015 ◽  
Vol 03 (02) ◽  
pp. 080-084
Author(s):  
Vijay Singh ◽  
Poonam Bogra ◽  
Saurabh Gupta ◽  
Navneet Kukreja ◽  
Neha Gupta

AbstractFracture resistance of endodontically treated teeth restored with post. Aims: This study aims to compare the fracture resistance of endodontically treated teeth restored with resin fiber and stainless steel post. Commercially available prefabricated resin fiber post(Dentsply Maillefer Easy Post), prefabricated stainless steel post(Coltene/Whaledent Parapost) were used. Methods and Material: Forty five maxillary central incisors were obturated and divided into 3 groups: Control Group (Group I) without any post (n = 15), Resin Fiber Post Group (Group II) (n = 15) and Stainless Steel Post Group (Group III) (n = 15). In all Groups except control group, post space was prepared; a post was cemented, and a core build-up was provided. All the specimens were subjected to compressive force under a universal testing machine until fracture. Statistical analysis used: The results were analyzed using the variable analysis test (ANOVA). Results: One-way analysis of variance revealed significant difference among test groups. The control group demonstrated highest fracture resistance (925.2183 N), followed by the resin fiber post group (486.7265 N) and stainless steel post group (423.539N). Conclusions: Teeth restored with resin fiber post showed higher fracture resistance values than prefabricated stainless steel post.


2019 ◽  
Vol 2019 ◽  
pp. 1-12 ◽  
Author(s):  
Noha Badran ◽  
Sanaa Abdel Kader ◽  
Fayza Alabbassy

Statement of Problem. In some clinical situations, the vertical length of either a prepared tooth or an implant abutment is short, while the occlusal clearance to be restored by a porcelain crown is large. Incisal thickness of the veneering porcelain should be considered to prevent mechanical failure of the crown. Purpose. The aim of this study is to evaluate the effect of two different incisal veneering porcelain thickness on the fracture resistance of the anterior all-ceramic CAD/CAM zirconia crown system as compared with the conventionally used metal ceramic crown system. Method. CAD/CAM zirconia all-ceramic and metal ceramic crowns were fabricated on the prepared dies with standardized dimensions and designs using standardized methods according to the manufacturer’s instructions. All crowns were then adhesively luted with resin-based cement (Multilink cement system), subjected to thermal cycling and cyclic loading, and were loaded until fracture using the universal testing machine to indicate the fracture resistance for each crown material in each veneering thickness. Results. Statistical analysis was carried out, and the results showed that the fracture resistance of the nickel-chromium metal ceramic group was significantly higher than that of the CAD/CAM zirconia all-ceramic group. Also, the fracture resistance of crowns with 1.5 mm incisal veneering thickness was significantly higher than those with 3 mm incisal veneering thickness in both groups. Furthermore, there was no significant difference in the fracture mode of the two groups where 50% of the total specimens demonstrated Mode II (veneer chipping), while 35% demonstrated Mode I (visible crack) and only 15% demonstrated Mode III (bulk fracture). Conclusion. High failure load values were demonstrated by the specimens in this study, which suggest sufficient strength of both incisal veneering thickness in both crown systems to withstand clinical applications; however, the fracture patterns still underline the requirement of a core design that support a consistent thickness of the veneering ceramic, and it is recommended to conduct long-term prospective clinical studies to confirm findings reported in the present study.


2018 ◽  
Vol 145 ◽  
pp. 04003
Author(s):  
Ekaterina Karteva ◽  
Neshka Manchorova ◽  
Dessislava Pashkouleva ◽  
Donka Keskinova ◽  
Stoyan Vladimirov

Endodontically treated teeth (ETT) are more susceptible to fracture during mastication. The aim of our study was to investigate the fracture resistance of premolars, restored with different techniques. Eighteen human premolars, extracted for orthodontic or periodontal reasons, were used. Mesio-occlusal cavities were prepared on all of them. They were divided into 3 groups according to the restoration method: with a cemented fiber post (FP), with a cemented metal post (MP) and without a post, but restored with a fiber reinforced composite core (FRC). After thermocycling, their fracture resistance was evaluated in a standard testing machine. The results were analyzed with one-way ANOVA and Tukey Honestly Significant Difference (HSD) tests (p<0.05). The fracture modes were also determined. The MP group showed the lowest fracture resistance rates and the highest number of unrestorable root fractures. In conclusion, teeth restored with FRC cores or FP show better survival rates than those restored with metal posts.


2020 ◽  
Vol 14 (02) ◽  
pp. 245-249
Author(s):  
Haider Hasan Jasim ◽  
Meelad Basil Findakly ◽  
Nada Ali Mahdi ◽  
Mustafa Tariq Mutar

Abstract Objectives The aim of this study was to compare the effects of two margin designs (shoulderless and slight chamfer) with two occlusal thicknesses on fracture resistance and failure mode of the monolithic zirconia crowns. Materials and Methods Forty nickel–chromium dies were duplicated from the previous two prepared teeth using a three-dimensional optical scanner. Nickel–chromium supporting dies were divided into two main groups (n = 20) according to the type of margin design: group A, slight chamfer margin design and group B, shoulderless margin design. These groups were further divided into two subgroups according to the occlusal thicknesses (0.5 and 1 mm). The digital imaging of each die was done using a three-dimensional optical scanner, then zirconia blocks were milled by 5-axis machine. The crowns were cleaned by alcohol, air dried, and cemented by resin cement. Next, the crowns were subjected to 500 hot and cold cycles (30 seconds for each cycle). The samples were subjected to a static load until failure using an electronic universal testing machine and fracture resistance was recorded in Newton (N). Statistical Analysis Data were analyzed using the test of normality (Shapiro–Wilk test) and two-way analysis of variance (ANOVA) test. Results  The highest mean fracture load was recorded by the shoulderless (1 mm occlusal thickness) subgroup (3,992.5 N), followed by shoulderless (0.5 mm occlusal thickness) subgroup (3,244.4 N), and the slight chamfer (1 mm occlusal thickness) subgroup (2,811 N). The lowest mean of fracture load was recorded by slight chamfer (0.5 mm occlusal thickness) subgroup (1,632.9 N). The two-way ANOVA test revealed a significant difference between the four subgroups. Regarding the fracture mode, the slight chamfer subgroups showed a severe fracture of the restoration while the shoulderless subgroups showed a fracture through the midline of the restoration. Conclusion Within the limitation of the comparative study, shoulderless margin design has a more favorable outcome than a slight chamfer design in all thicknesses. Although the restoration with reduced occlusal thickness has lower fracture resistance than 1 mm occlusal thickness, the 0.5 mm restorations still can tolerate occlusal forces.


2008 ◽  
Vol 9 (4) ◽  
pp. 17-25 ◽  
Author(s):  
Ilser Turkyilmaz ◽  
Suat Gokce ◽  
Emine Celik-Bagci

Abstract Aim The aim of this study was to investigate the influence of three different thicknesses of In-Ceram core on the load at fracture of all-ceramic crowns. Methods and Materials Thirty standardized crown-shaped nickel-chromium alloy dies were fabricated using a milling machine. Twenty dies were prepared with a 1 mm shoulder for Groups A and B. The only difference in the ten dies used for Group C was a smaller 0.5 mm lingual shoulder. The thicknesses of In-Ceram were 0.5 mm, 1.5 mm, and 0.75 mm for Groups A, B, and C. All all-ceramic crowns were fabricated in accordance with the manufacturer's instructions. After cementation of the crowns, their fracture resistance was tested with a universal testing machine. The load was directed to a point located 3 mm from the lingual aspect of the incisal edge at 30 degrees to the long axis of each specimen until catastrophic failure occurred. Results The mean loads at fracture for Groups A, B, and C were 1117±388 N, 2083±385 N, and 1439±368 N, respectively. No statistically significant difference in load at fracture between Groups A and C was found (p>0.05). However, the differences were statistically significant between Groups A and B (p<0.001) and Groups B and C (p<0.001). Conclusion Under the guidelines of this study, increasing the thickness of the In-Ceram core increased the fracture resistance of the all-ceramic crowns. Clinical Significance The sufficient thickness of the In-Ceram core of all-ceramic crowns is an important factor in fracture resistance. Therefore, dental practitioners should be careful in patient selection; if the horizontal overlap of a tooth to be restored is too limited, then all-ceramic crowns may not be a feasible option. Citation Gokce S, Celik-Bagci E, Turkyilmaz I. A Comparative in vitro Study of the Load at Fracture of Allceramic Crowns with Various Thicknesses of In-Ceram Core. J Contemp Dent Pract 2008 May; (9)4:017-025.


2021 ◽  
Vol 24 (4) ◽  
Author(s):  
Marwa Emam ◽  
Amr El-Etreby ◽  
Jihan Farouk Younis

Objective: The purpose of this in vitro study is to evaluate the effect of four finish line configurations and two cement types on the fracture resistance of zirconia copings. Material and Methods: Forty yttrium tetragonal zirconia polycrystals copings were manufactured on epoxy resin dies with four preparation designs: knife edge, chamfer, deep chamfer 0.5, 1 mm and shoulder 1 mm. The copings were cemented with two cement types (glass ionomer and resin cement); (n = 5). Two strain gauges were attached on each coping before they were vertically loaded till fracture with a universal testing machine. Data were analyzed by 2-way analysis of variance ANOVA (p < .05). Fractured specimens were examined for mode of failure with digital microscope. Results: Knife edge showed the highest mean fracture resistance (987.04 ± 94.18) followed by Chamfer (883.28 ± 205.42) followed by Shoulder (828.64 ± 227.79) and finally Deep chamfer finish line (767.66 ± 207.09) with no statistically significant difference. Resin cemented copings had higher mean Fracture resistance (911.76 ± 167.95) than glass ionomer cemented copings (821.55 ± 224.24) with no statistically significant difference. Knife edge had the highest strain mean values on the buccal (374.04 ± 195.43) and lingual (235.80 ± 103.46) surface. Shoulder finish line showed the lowest mean strain values on the buccal (127.47 ± 40.32) and lingual (68.35 ± 80.68) with no statistically significant difference. Resin cemented copings had higher buccal (295.05 ± 167.92) and lingual (197.38 ± 99.85) mean strain values  than glass ionomer copings (149.14 ± 60.94) and (90.27 ± 55.62) with no statistically significant difference. Conclusion: Vertical knife edge finish line is a promising alternative and either adhesive or conventional cementation can be used with zirconia copings.   KEYWORDS Cementation; Flexural strength; Prosthodontics; Tooth preparation; Zirconium.


2021 ◽  
Vol 8 ◽  
Author(s):  
Elke Pollaris ◽  
Bart J. G. Broeckx ◽  
Sivaprakash Rajasekharan ◽  
Rita Cauwels ◽  
Lieven Vlaminck

Background:Ex vivo fracture models are frequently used in human dentistry to provide insights in the fracture mechanisms of teeth. Equine cheek teeth fractures are an important dental pathology, but there has been no research performed to examine the fracture resistance ex vivo.Objective: To evaluate the fracture resistance of equine cheek teeth and identify anatomical predictors that might influence fracture resistance in healthy teeth. It was further evaluated if the presence of a fissure caused a decrease in fracture resistance.Study design:Ex vivo experimental design.Methods: Individual cheek teeth were subjected to a compression load in a universal testing machine until fracture occurred. Testing was performed in two study groups. A first group of healthy cheek teeth was tested to examine anatomical predictors on fracture resistance. A second group comprised cheek teeth with occlusal fissures and an equal number of age- and size-matched fissure-free teeth as controls. The effect of possible predictors on fracture resistance was investigated by regression analysis.Results: In the first group, fracture resistance was significantly influenced by the location on the tooth where testing was performed in both maxillary (p &lt; 0.001) and mandibular teeth (p &lt; 0.001). Additional significantly associated factors were Triadan number in mandibular (p = 0.009) and the mesiodistal length of the occlusal surface of maxillary teeth (p = 0.01). Experimentally induced crown fractures that extended below the simulated bone level were more frequently associated with pulp horn exposure (p &lt; 0.001). In the second group, significant lower fracture loads were recorded in teeth with fissures (mandibular p = 0.006; maxillary p &lt; 0.001), compared to fissure-free teeth.Main limitations: This ex vivo model does not imitate the in vivo masticatory forces and lacks the shock-absorbing properties of the periodontal ligament.Conclusions: The methodology used in this study provides an ex vivo experimental set-up to test fracture resistance of equine cheek teeth enabling evidence-based research to examine the potentially weakening effects of tooth pathology and its treatments. Crown resistance to fracture differed along the occlusal surface of healthy equine cheek teeth, and the presence of fissures further decreased fracture resistance.


2020 ◽  
Author(s):  
Xia Juan ◽  
Wang weidong ◽  
Li Zhengmao ◽  
Lin Bingpeng ◽  
Zhang Qian ◽  
...  

Abstract Background: This study aims to compare the percentage of dentin removed, instrumentation efficacy, root canal filling and load at fracture between contracted endodontic cavities, and traditional endodontic cavities on root canal therapy in premolars. Methods: Forty extracted intact human first premolars were imaged with micro-CT and randomly assigned to the contracted endodontic cavity (CEC) or traditional endodontic cavity (TEC) groups. CEC was prepared with the aid of a 3D-printed template, canals were prepared with a 0.04 taper M-Two rotary instrument, and cavities were restored with resin. Specimens were loaded to fracture in an Instron Universal Testing Machine after a fatigue phase. The data were analyzed by the independent samples T test and Mann-Whitney U test, appropriate post hoc tests. Results: In the premolars tested in vitro, the percentage of dentin removed in the premolars with two dental roots in the CEC group (3.85% ± 0.42%) was significantly smaller (P < 0.05) than in the TEC group (4.94% ± 0.5%). The untouched canal wall (UCW) after instrumentation for TECs (16.43% ± 6.56%) was significantly lower (P< .05) than the UCW (24.42% ± 9.19%) for CECs in single-rooted premolars. No significant differences were observed in the increased canal volume and surface areas in premolars between the TEC and CEC groups (P > 0.05). CECs conserved coronal dentin in premolars with two dental roots but no impact on the instrument efficacy. There were no differences between the CEC groups and the TEC groups in the percentage of filling material and voids (P > 0.05). In addition, the mean load at failure of premolars did not significantly differ between the CEC and TEC groups and there was no significant difference in the type of fracture (P > 0.05). Conclusion: The results of this study suggest that CEC could not improve the fracture resistance of the endodontically treated premolars. The instrumentation efficacy and the percentage of filling material did not significantly differ between CECs and TECs in premolars. Keywords: 3D-printed template, contracted endodontic cavities, instrumentation efficacy, root canal filling, fracture resistance


Author(s):  
Shahram Mosharrafian ◽  
Maryam Shafizadeh ◽  
Zeinab Sharifi

Objectives: This study aimed to compare the fracture resistance of a bulk-fill and a conventional composite and a combination of both for coronal restoration of severely damaged primary anterior teeth. Materials and Methods: In this in vitro experimental study, 45 primary anterior teeth were randomly divided into three groups. After root canal preparation, the canals were filled with Metapex paste such that after the application of 1 mm of light-cure liner, 3 mm of the coronal third of the canal remained empty for composite post fabrication. Filtek Z250 conventional composite was used in group 1, Sonic-Fill bulk-fill composite was used in group 2 and Sonic-Fill with one layer of Filtek Z250 as the veneering were used in group 3. Adper Single Bond 2 was used in all groups. The teeth were thermocycled, and fracture resistance was measured by a universal testing machine. The mode of fracture was categorized as repairable or irreparable. Data were analyzed using one-way ANOVA. Results: The mean fracture resistance was 307.00±74.72, 323.31±84.28 and 333.30±63.96 N in groups 1 to 3, respectively (P=0.55). The mean fracture strength was 14.53±2.98, 15.08±2.82 and 15.26±3.02 MPa in groups 1 to 3, respectively (P=0.77). The frequency of repairable mode of failure was 80% for the conventional, 73.6% for the bulk-fill and 80% for the bulk-fill plus conventional group, with no significant difference (P>0.05). Conclusions: Bulk-fill composites can be used for coronal reconstruction of severely damaged primary anterior teeth similar to conventional composites to decrease the treatment time in pediatric patients.


2016 ◽  
Vol 27 (4) ◽  
pp. 442-445 ◽  
Author(s):  
Beatriz Carlos Correa ◽  
Rodrigo Galo ◽  
Camila Scatena ◽  
Maria Cristina Borsatto ◽  
Aloísio Oro Spazzin ◽  
...  

Abstract This study evaluated the effect of matrix metalloproteinase (MMP) inhibitors - 2% (CHX) and sodium fluoride (NaF) (5000 ppm) - on microtensile bond strength (μTBS) of composite resin to Er:YAG laser-irradiated dentin after chemical degradation of the bond interface. The occlusal surface of forty sound human molars was removed exposing the dentin surface (n=10), which was polished, irradiated with Er:YAG laser, acid etched and dried. Twenty specimens were rewetted with 2% CHX (control group) and 20 were rewetted with NaF (5000 ppm). The adhesive system was applied and a 4-mm-high plateau of light-cured composite resin was built up. Resin-dentin sticks were obtained with a rectangular cross-sectional area (0.8-1 mm2) and were either stored in water at 37 ?#61616;C for 24 h or submitted to chemical degradation. For chemical degradation, they were immersed in 10% NaOCl aqueous solution for 5 h and rinsed in water for 1 h. The sticks were submitted to microtensile test in a mechanical testing machine at 0.5 mm/min until failure. Fracture pattern was analyzed using SEM. μTBS values were calculated in MPa and submitted to analysis of variance ANOVA (α=0.05). The variance analysis showed that the 'MMP inhibitor' and 'degradation' factors (p=0.214 and p=0.093, respectively) and interaction between the factors were not statistically significant (p=0.143). Mixed failure predominated in all groups. In conclusion, the 2% CHX and NaF 5000 ppm presented similar μTBS of composite resin to laser-irradiated dentin before and after chemical degradation


Sign in / Sign up

Export Citation Format

Share Document