Compound Library Management in High Throughput Screening

1997 ◽  
Vol 2 (2) ◽  
pp. 99-102 ◽  
Author(s):  
Paul A. Gosnell ◽  
Amy D. Hilton ◽  
Lynette M. Anderson ◽  
Lyman Wilkins ◽  
William P. Janzen

Compound library management is inherent to the success of a high throughput screen. The library management system developed at Sphinx Pharmaceuticals accomplishes this through a series of Paradox and Orade database applications. This suite of applications allows compounds to be grouped as libraries, inventoried, and scheduled for testing in a screen. Compound libraries can be defied using any combination of source, structure, and target, and may be divided into sublibraries, allowing a flexible mix of compounds to be scheduled across several targets. Test requests can then be made for an entire library, sublibrary, or individual mother plates. The priority of requests is set by a combination of assay and compound source, allowing management of sources that require special handling. An inventory module tracks both physical volumes and the volume available for requests by plate and well. Positive sample tracking is maintained throughout the screening process from the time of request through the compound preparation process, to the date of test, and subsequent re-test if necessary. Furthermore, assay results can be tracked to the exact well on the assay plate. The tracking of this data allows a flexible diversity set for each target, tracks compound preparation to date, and facilitates the scheduling of preparation.


2017 ◽  
Vol 22 (10) ◽  
pp. 1203-1210 ◽  
Author(s):  
Katrin Beeman ◽  
Jens Baumgärtner ◽  
Manuel Laubenheimer ◽  
Karlheinz Hergesell ◽  
Martin Hoffmann ◽  
...  

Mass spectrometry (MS) is known for its label-free detection of substrates and products from a variety of enzyme reactions. Recent hardware improvements have increased interest in the use of matrix-assisted laser desorption/ionization time-of-flight (MALDI-TOF) MS for high-throughput drug discovery. Despite interest in this technology, several challenges remain and must be overcome before MALDI-MS can be integrated as an automated “in-line reader” for high-throughput drug discovery. Two such hurdles include in situ sample processing and deposition, as well as integration of MALDI-MS for enzymatic screening assays that usually contain high levels of MS-incompatible components. Here we adapt our c-MET kinase assay to optimize for MALDI-MS compatibility and test its feasibility for compound screening. The pros and cons of the Echo (Labcyte) as a transfer system for in situ MALDI-MS sample preparation are discussed. We demonstrate that this method generates robust data in a 1536-grid format. We use the MALDI-MS to directly measure the ratio of c-MET substrate and phosphorylated product to acquire IC50 curves and demonstrate that the pharmacology is unaffected. The resulting IC50 values correlate well between the common label-based capillary electrophoresis and the label-free MALDI-MS detection method. We predict that label-free MALDI-MS-based high-throughput screening will become increasingly important and more widely used for drug discovery.



2005 ◽  
Vol 10 (7) ◽  
pp. 725-729 ◽  
Author(s):  
Upasana Singh ◽  
Vinita Panchanadikar ◽  
Dhiman Sarkar

Mycobacterium tuberculosis glutamine synthetase (GS) is an essential enzyme involved in the pathogenicity of the organism. The screening of a compound library using a robust high-throughput screening (HTS) assay is currently thought to be the most efficient way of getting lead molecules, which are potent inhibitors for this enzyme. The authors have purified the enzyme to a >90% level from the recombinant Escherichia coli strain YMC21E, and it was used for partial characterization as well as standardization experiments. The results indicated that the Kmof the enzyme for L-glutamine and hydroxylamine were 60 mM and 8.3 mM, respectively. The Km for ADP, arsenate, and Mn2+ were 2 [.proportional]M, 5 [.proportional]M, and 25 [.proportional]M, respectively. When the components were adjusted according to their Km values, the activity remained constant for at least 3 h at both 25° C and 37° C. The Z′ factor determined in microplate format indicated robustness of the assay. When the signal/noise ratios were determined for different assay volumes, it was observed that the 200-[.proportional]l volume was found to be optimum. The DMSO tolerance of the enzyme was checked up to 10%, with minimal inhibition. The IC50 value determined for L-methionine S-sulfoximine on the enzyme activity was 3 mM. Approximately 18,000 small molecules could be screened per day using this protocol by a Beckman Coulter HTS setup.



2018 ◽  
Vol 23 (7) ◽  
pp. 697-707 ◽  
Author(s):  
John Joslin ◽  
James Gilligan ◽  
Paul Anderson ◽  
Catherine Garcia ◽  
Orzala Sharif ◽  
...  

The goal of high-throughput screening is to enable screening of compound libraries in an automated manner to identify quality starting points for optimization. This often involves screening a large diversity of compounds in an assay that preserves a connection to the disease pathology. Phenotypic screening is a powerful tool for drug identification, in that assays can be run without prior understanding of the target and with primary cells that closely mimic the therapeutic setting. Advanced automation and high-content imaging have enabled many complex assays, but these are still relatively slow and low throughput. To address this limitation, we have developed an automated workflow that is dedicated to processing complex phenotypic assays for flow cytometry. The system can achieve a throughput of 50,000 wells per day, resulting in a fully automated platform that enables robust phenotypic drug discovery. Over the past 5 years, this screening system has been used for a variety of drug discovery programs, across many disease areas, with many molecules advancing quickly into preclinical development and into the clinic. This report will highlight a diversity of approaches that automated flow cytometry has enabled for phenotypic drug discovery.



2000 ◽  
Vol 22 (5) ◽  
pp. 149-157 ◽  
Author(s):  
Ralf Thiericke

Secondary metabolites from plants, animals and microorganisms have been proven to be an outstanding source for new and innovative drugs and show a striking structural diversity that supplements chemically synthesized compounds or libraries in drug discovery programs. Unfortunately, extracts from natural sources are usually complex mixtures of compounds:: often generated in time consuming and for the most part manual processes. As quality and quantity of the provided samples play a pivotal role in the success of high-throughput screening programs this poses serious problems. In order to make samples of natural origin competitive with synthetic compound libraries, we devised a novel, automated sample preparation procedure based on solid-phase extraction (SPE). By making use of a modified Zymark RapidTrace®SPE workstation an easy-to-handle and effective fractionation method has been developed which allows the generation of highquality samples from natural origin, fulfilling the requirements of an integration into high-throughput screening programs.



2008 ◽  
Vol 13 (9) ◽  
pp. 879-887 ◽  
Author(s):  
William E. Severson ◽  
Michael McDowell ◽  
Subramaniam Ananthan ◽  
Dong-Hoon Chung ◽  
Lynn Rasmussen ◽  
...  

Using a highly reproducible and robust cell-based high-throughput screening (HTS) assay, the authors screened a 100,000-compound library at 14- and 114-µM compound concentration against influenza strain A/Udorn/72 (H3N2). The “hit” rates (>50% inhibition of the viral cytopathic effect) from the 14- and 114-µM screens were 0.022% and 0.38%, respectively. The hits were evaluated for their antiviral activity, cell toxicity, and selectivity in dose-response experiments. The screen at the lower concentration yielded 3 compounds, which displayed moderate activity (SI50 = 10-49). Intriguingly, the screen at the higher concentration revealed several additional hits. Two of these hits were highly active with an SI50 > 50. Time of addition experiments revealed 1 compound that inhibited early and 4 other compounds that inhibited late in the virus life cycle, suggesting they affect entry and replication, respectively. The active compounds represent several different classes of molecules such as carboxanilides, 1-benzoyl-3-arylthioureas, sulfonamides, and benzothiazinones, which have not been previously identified as having antiviral/anti-influenza activity. ( Journal of Biomolecular Screening 2008:879-887)



2011 ◽  
Vol 16 (9) ◽  
pp. 1007-1017 ◽  
Author(s):  
Joost C. M. Uitdehaag ◽  
Cecile M. Sünnen ◽  
Antoon M. van Doornmalen ◽  
Nikki de Rouw ◽  
Arthur Oubrie ◽  
...  

Over the past years, improvements in high-throughput screening (HTS) technology and compound libraries have resulted in a dramatic increase in the amounts of good-quality screening hits, and there is a growing need for follow-on hit profiling assays with medium throughput to further triage hits. Here the authors present such assays for the colony-stimulating factor 1 receptor (CSF1R, Fms), including tests for cellular activity and a homogeneous assay to measure affinity for inactive CSF1R. They also present a high-throughput assay to measure target residence time, which is based on competitive binding kinetics. To better fit koff rates, they present a modified mathematical model for competitive kinetics. In all assays, they profiled eight reference inhibitors (imatinib, sorafenib, sunitinib, tandutinib, dasatinib, GW2580, Ki20227, and J&J’s pyrido[2,3-d]pyrimidin-5-one). Using the known biochemical selectivities of these inhibitors, which can be quantified using metrics such as the selectivity entropy, the authors have determined which assay readout best predicts hit selectivity. Their profiling shows surprisingly that imatinib has a preference for the active form of CSF1R and that Ki20227 has an unusually slow target dissociation rate. This confirms that follow-on hit profiling is essential to ensure that the best hits are selected for lead optimization.



2001 ◽  
Vol 6 (6) ◽  
pp. 429-440 ◽  
Author(s):  
Michael W. Pantoliano ◽  
Eugene C. Petrella ◽  
Joseph D. Kwasnoski ◽  
Victor S. Lobanov ◽  
James Myslik ◽  
...  

More general and universally applicable drug discovery assay technologies are needed in order to keep pace with the recent advances in combinatorial chemistry and genomics-based target generation. Ligand-induced conformational stabilization of proteins is a well-understood phenomenon in which substrates, inhibitors, cofactors, and even other proteins provide enhanced stability to proteins on binding. This phenomenon is based on the energetic coupling of the ligand-binding and protein-melting reactions. In an attempt to harness these biophysical properties for drug discovery, fully automated instrumentation was designed and implemented to perform miniaturized fluorescence-based thermal shift assays in a microplate format for the high throughput screening of compound libraries. Validation of this process and instrumentation was achieved by investigating ligand binding to more than 100 protein targets. The general applicability of the thermal shift screening strategy was found to be an important advantage because it circumvents the need to design and retool new assays with each new therapeutic target. Moreover, the miniaturized thermal shift assay methodology does not require any prior knowledge of a therapeutic target's function, making it ideally suited for the quantitative high throughput drug screening and evaluation of targets derived from genomics.



2005 ◽  
Vol 10 (4) ◽  
pp. 374-382 ◽  
Author(s):  
Susan M. Young ◽  
Cristian Bologa ◽  
Eric R. Prossnitz ◽  
Tudor I. Oprea ◽  
Larry A. Sklar ◽  
...  

High-throughput flow cytometry (HTFC), enabled by faster automated sample processing, represents a promising high- content approach for compound library screening. HyperCyt® is a recently developed automated HTFC analysis system by which cell samples are rapidly aspirated from microplate wells and delivered to the flow cytometer. The formylpeptide receptor (FPR) family of G protein–coupled receptors contributes to the localization and activation of tissue-damaging leukocytes at sites of chronic inflammation. Here, the authors describe development and application of an HTFC screening approach to detect potential anti-inflammatory compounds that block ligand binding to FPR. Using a homogeneous no-wash assay, samples were routinely processed at 1.5 s/well (~2500 cells analyzed/sample), allowing a 96-well plate to be processed in less than 2.5 min. Assay sensitivity and accuracy were validated by detection of a previously documented active compound with relatively low FPR affinity (sulfinpyrazone, inhibition constant [Ki]=14 μM) from among a collection of 880 compounds in the Prestwick Chemical Library. The HyperCyt® system was therefore demonstrated to be a robust, sensitive, and highly quantitative method with which to screen lead compound libraries in a 96-well format.



Sign in / Sign up

Export Citation Format

Share Document