scholarly journals First field application of temperature sensor modules for groundwater flow detection near borehole heat exchanger

2019 ◽  
Vol 7 (1) ◽  
Author(s):  
Alexander Michalski ◽  
Norbert Klitzsch

AbstractHere, we present the first application of a temperature sensor module (TSM) for deducing groundwater flow velocity and direction at borehole heat exchangers (BHEs). The TSM maps the horizontal temperature distribution around a BHE. As groundwater flow distorts this temperature distribution, flow velocity and direction can be inferred from the measured temperatures. As modular systems, TSMs can be attached to a BHE at any depth. For the studied BHE, the depths of interest are 82 m and at 94 m. We recorded TSM data for 2 weeks before and during the operation of the BHE. After simulating the working fluid temperature, we model the horizontal temperature distributions using the working fluid temperatures at the depths of interest as input. We use the latter simulations for inferring groundwater flow by minimizing the root mean square error between the measured and simulated temperatures. We obtain a groundwater flow of 0.4 m/day in the NW direction and groundwater flow below the detection limit of 0.01 m to 0.02 m/day at 82 m and 94 m depths, respectively. A flow meter measurement in a nearby groundwater well confirms the flow direction at 82 m but gives an order of magnitude higher velocity, which we attribute to the measurement principle. Moreover, long-term monitoring of a BHE equipped with multiple TSMs could provide information on seasonal variations in groundwater flow, changes in the thermal properties of the BHE filling or changes in the thermal resistance between BHE and ground.

2011 ◽  
Vol 347-353 ◽  
pp. 2640-2644 ◽  
Author(s):  
Xue Tao Duan ◽  
Bin Xu ◽  
Hao Luo

This paper investigated the behaviors of flow and heat transfer of single-phase in rectangular micro-channels with three-dimensional numerical analysis. The single micro-channel is 200μm deep, 50μm wide. Deionized water was used as the working fluid. The fluid physical properties varying with temperature and Re number were studied. Comparisons were made among the results obtained from experiments, numerical simulations, and from those in the literature. The results indicated that the friction factors decreasing along the flow direction were ascribed to the fluid temperature rising under the unified heat flux boundary condition. It was found that influence of viscosity variation with temperature and viscous dissipation effect could be too significant to be neglected.


Author(s):  
Ennio Macchi ◽  
Giampaolo Manzolini ◽  
Paolo Silva

The role of renewable energies and in particular solar energy could be fundamental in future scenarios of worldwide increase of energy demand: thermodynamic solar energy can play an important role in country with high solar radiation. This paper discusses the development and testing of an innovative code for the prediction of thermodynamic performances at nominal conditions and the estimation of costs of the whole plant, for different parabolic trough solar fields. The code allows a preliminary design of the solar field lay-out, the sizing of the main components of the plant and the optimization of the steam cycle. The code, named PATTO (PArabolic Trough Thermodynamic Optimization), allows to separately calculate the thermal efficiency of (i) parabolic trough systems in commerce as well as (ii) combination of components of various commercial systems, in order to exploit different technology solutions: combination of mirrors, receivers and supports. Using the selected parabolic troughs, the plant configuration is then completed by connecting pipes, heat exchangers, the steam cycle, and storage tanks. The code is also flexible in terms of working fluid, temperature and pressure range. Regarding the power block, a conventional steam cycle with super-heater and re-heater sections and up to seven regenerative bleedings is adopted. It is possible to use also simpler configuration as without re-heater or with less regenerative bleedings. Moreover, thanks to simple or sophisticated economic correlations depending on available data, the code calculates the overall investment cost for the considered solar field and the power block. The code performs steady state analysis at nominal conditions, while future developments are planned regarding part load analysis and transient simulations. The model is tested towards real applications and reference values found in literature; in particular, focusing on SEGS VI plant in the USA. Detailed results showing code potentiality, are presented in terms of solar field and power block energy balances, plant auxiliaries, piping and economic analysis.


2021 ◽  
Author(s):  
Goedele Verreydt ◽  
Niels Van Putte ◽  
Timothy De Kleyn ◽  
Joris Cool ◽  
Bino Maiheu

<p>Groundwater dynamics play a crucial role in the spreading of a soil and groundwater contamination. However, there is still a big gap in the understanding of the groundwater flow dynamics. Heterogeneities and dynamics are often underestimated and therefore not taken into account. They are of crucial input for successful management and remediation measures. The bulk of the mass of mass often is transported through only a small layer or section within the aquifer and is in cases of seepage into surface water very dependent to rainfall and occurring tidal effects.</p><p> </p><p>This study contains the use of novel real-time iFLUX sensors to map the groundwater flow dynamics over time. The sensors provide real-time data on groundwater flow rate and flow direction. The sensor probes consist of multiple bidirectional flow sensors that are superimposed. The probes can be installed directly in the subsoil, riverbed or monitoring well. The measurement setup is unique as it can perform measurements every second, ideal to map rapid changing flow conditions. The measurement range is between 0,5 and 500 cm per day.</p><p> </p><p>We will present the measurement principles and technical aspects of the sensor, together with two case studies.</p><p> </p><p>The first case study comprises the installation of iFLUX sensors in 4 different monitoring wells in a chlorinated solvent plume to map on the one hand the flow patterns in the plume, and on the other hand the flow dynamics that are influenced by the nearby popular trees. The foreseen remediation concept here is phytoremediation. The sensors were installed for a period of in total 4 weeks. Measurement frequency was 5 minutes. The flow profiles and time series will be presented together with the determined mass fluxes.</p><p> </p><p>A second case study was performed on behalf of the remediation of a canal riverbed. Due to industrial production of tar and carbon black in the past, the soil and groundwater next to the small canal ‘De Lieve’ in Ghent, Belgium, got contaminated with aliphatic and (poly)aromatic hydrocarbons. The groundwater contaminants migrate to the canal, impact the surface water quality and cause an ecological risk. The seepage flow and mass fluxes of contaminants into the surface water were measured with the novel iFLUX streambed sensors, installed directly in the river sediment. A site conceptual model was drawn and dimensioned based on the sensor data. The remediation concept to tackle the inflowing pollution: a hydraulic conductive reactive mat on the riverbed that makes use of the natural draining function of the waterbody, the adsorption capacity of a natural or secondary adsorbent and a future habitat for micro-organisms that biodegrade contaminants. The reactive mats were successfully installed and based on the mass flux calculations a lifespan of at least 10 years is expected for the adsorption material.  </p>


2013 ◽  
Vol 433-435 ◽  
pp. 1563-1566
Author(s):  
Jian Lin Zhang

An intelligent thermometer system design is presented in this paper. There are temperature sensor module, data collection module, data processing module, keyboard number tube module, voice module and LCD display module in this system. Due to excellent performance of temperature sensor, temperature sensor is used in system to obtain the temperature, transform the voltage, amplify OP precisely, and get 12 bits accuracy of samples. In order to make the system interface friendly, embedded software is developed to realize such functions as alarm temperature settings, LED screen display, audio playback and so on.


Energies ◽  
2018 ◽  
Vol 11 (11) ◽  
pp. 2960 ◽  
Author(s):  
Carlo Renno

The knowledge of the actual energy performances of a concentrating photovoltaic and thermal (CPV/T) system with a linear focus optics, allows to evaluate the possibility of adopting this type of system for cogeneration purposes. Hence, the main aim of this paper is the design, realization, setting and modeling of a linear focus CPV/T system in the high concentration field. An experimental linear focus CPV/T plant was created in order to determine its electrical and thermal performance under different working conditions in terms of environment temperature, sunny and cloudy conditions, focal length, etc. Moreover, a theoretical model of the linear focus CPV/T system was also studied. This model evaluates the temperatures of the working fluid that flows in the cooling circuit of the CPV/T system under several operating conditions. The temperatures of the triple junction (TJ) cells, experimentally evaluated referring to different solar radiation and atmospheric conditions, were considered as the input data for the model. The values of the fluid temperature, theoretically and experimentally determined, were thus compared with good agreement. The electrical production of the CPV/T system depends generally on the TJ cell characteristics and the concentration factor, while the thermal production is above all linked to the system configuration and the direct normal irradiance (DNI) values. Hence, in this paper the electric power obtained by the linear-focus CPV/T system was evaluated referring to the cogeneration applications, and it was verified if the TJ cell and the cooling fluid reach adequate temperature levels in this type of system, in order to match the electrical and the thermal loads of a user.


Author(s):  
Huayi Feng ◽  
Yanping Zhang ◽  
Chongzhe Zou

In this paper, a 3-D numerical model is proposed to investigate the capability of generating high operating temperature for a modified solar cavity receiver in large-scale dish Stirling system. The proposed model aims to evaluate the influence of radiation intensity on the cavity receiver performance. The properties of the heat transfer fluid in the pipe and heat transfer losses of the receiver are investigated by varying the direct normal irradiance from 400W/m2 to 1000W/m2. The temperature of heat transfer fluid, as well as the effect of radiation intensity on the heat transfer losses have been critically presented and discussed. The simulation results reveal that the heat transfer fluid temperature and thermal efficiency of the receiver are significantly influenced by different radiation flux. With the increase of radiation intensity, the efficiency of the receiver will firstly increase, then drops after reaching the highest point. The outlet working fluid temperature of the pipe will be increased consistently. The results of the simulations show that the designed cylindrical receiver used in dish Stirling system is capable to achieve the targeted outlet temperature and heat transfer efficiency, with an acceptable pressure drop.


Author(s):  
Nobuhiko Kamagata ◽  
Susumu Horio ◽  
Koichi Hishida

The active flow control, which can adapt to variation of flow velocity and/or direction, is an effective technique to achieve drag reduction. The present study has investigated a separated shear layer and established two control systems; the system reduces drag force and lift force by controlling the separated shear layer to reattachment for variation of flow velocity and /or direction. The adaptive control system to the variation of flow velocity was constructed by using a hot wire anemometer as a sensor to detect flow separation. The system to flow direction was constructed by using pressure transducers as a sensor to estimate drag force and lift force. The extremum-seeking control was introduced as a controller of the both systems. It is indicated from the experimental results that adaptive drag/lift control system to various flow velocity ranging from 3 to 7 m/s and various flow direction ranging from 0 to 30 deg. was established.


Author(s):  
Ziyang Cheng ◽  
Yaxiong Wang ◽  
Qingxuan Sun ◽  
Jiangfeng Wang ◽  
Pan Zhao ◽  
...  

Abstract This paper proposes a novel cogeneration system based on Kalina cycle and absorption refrigeration system to meet the design requirements of China State Shipbuilding Corporation, which is efficiently satisfy the power and cooling demands of a maritime ship at the same time. Unlike most of the combined systems, this cogeneration system is highly coupled and realizes cogeneration without increasing the system complexity too much. The basic ammonia mass fraction of this novel system is increased, so that the ammonia concentration of ammonia-water steam from the separator can be higher, which contributes to lower refrigerating temperature and thus less heat loss in the distillation process. In addition, higher ammonia concentration solution makes overheating easier, which improves the thermal efficiency. Moreover, the system has two recuperators to make further improvement of the thermal efficiency. Thermodynamic models are developed to investigate the system performance and parametric analysis is conducted to figure out the effects of including working fluid temperature at the outlet of the evaporator, working fluid temperature at superheater outlet, mass fraction of ammonia in basic solution, turbine inlet pressure, temperature of cooling water at the inlet of condensers and the refrigeration evaporation temperature on the system performance. Furthermore, the cogeneration system is optimized with genetic algorithm to obtain the best performance, which achieves 333.00kW of net power output, 28.83 kW of cooling capacity and 21.81% of thermal efficiency. Finally, the performance of the proposed system is compared with an optimized recuperative organic Rankine cycle (ORC) system and an optimized Kalina cycle system 34 (KCS34) using the same heat source. The results show that the thermal efficiency and power output of the novel cogeneration system is 3.89% and 1.05% higher than that of the recuperative ORC system and KCS34 system respectively.


Sign in / Sign up

Export Citation Format

Share Document