Experimental research on the stability bearing capacity of Q420 high-strength steel tubular members

Author(s):  
Buhui Li ◽  
Pingzhou Cao ◽  
Dachang Zhang ◽  
Tao Xu
2014 ◽  
Vol 638-640 ◽  
pp. 101-104
Author(s):  
Yi Liang Peng ◽  
Guo Tian Li ◽  
Xuan Min Han ◽  
Lei Chen

With the rapid development of power transmission and transformation projects in China, steel supporting structure has already became the most popular structural form for these structures. However, the limit of steel grade used for current substation supporting structures is normally Q420, compared with that of Q690 used in other countries. When the high-strength steel is used, the geometric parameters of section for members become smaller, and the stability of members is the most important factors to influence the bearing capacity of structures. The stability factor for axial loaded steel members in current 《Code for design of steel structures》(GB50017-2003) was derived based on the experimental results for steel members with lower steel grade, the results are inevitably different from those for high-strength steel members. To make the calculations of Q690 high-strength steel tubes more accurate and reasonable, this paper conducts experimental study on the bearing capacity of Q690 high-strength steel tubes under axial load to provide scientific basis for practical design of these structures.


2011 ◽  
Vol 474-476 ◽  
pp. 739-743
Author(s):  
Xian Lei Cao ◽  
Ji Ping Hao

Single-angle compression members with an eccentric load at one end were widely used in transmission towers, analyzing the stability bearing capacity become a very complex issue due to end restraint conditions and the impact of defects. Experiment method and analytical method were used to study the size of the stability capacity on four kinds of members, analytical method use energy relationship, the boundary conditions issue is simplified according to different end restraint capacity, and finally discuss the theoretical ultimate bearing capacity of the test members. Compared with the experimental results show that the elastic theory analytical solution overestimates the capacity of members, using experiment method can obtain more secure mechanical behavior of high-strength angle steel member with an eccentric load at one end.


Polymers ◽  
2021 ◽  
Vol 13 (23) ◽  
pp. 4267
Author(s):  
Qi Ye ◽  
Yingchun Gong ◽  
Haiqing Ren ◽  
Cheng Guan ◽  
Guofang Wu ◽  
...  

Cross-laminated timber (CLT) elements are becoming increasingly popular in multi-storey timber-based structures, which have long been built in many different countries. Various challenges are connected with constructions of this type. One such challenge is that of stabilizing the structure against vertical loads. However, the calculations of the stability bearing capacity of the CLT members in axial compression in the structural design remains unsolved in China. This study aims to determine the stability bearing capacity of the CLT members in axial compression and to propose the calculation method of the stability coefficient. First, the stability coefficient calculation theories in different national standards were analyzed, and then the stability bearing capacity of CLT elements with four slenderness ratios was investigated. Finally, based on the stability coefficient calculation formulae in the GB 50005-2017 standard and the regression method, the calculation method of the stability coefficient for CLT elements was proposed, and the values of the material parameters were determined. The result shows that the average deviation between fitting curve and calculated results of European and American standard is 5.43% and 3.73%, respectively, and the average deviation between the fitting curve and the actual test results was 8.15%. The stability coefficients calculation formulae could be used to predict the stability coefficients of CLT specimens with different slenderness ratios well.


Author(s):  
Yonghui Hou ◽  
Shuangyin Cao ◽  
Xiangyong Ni ◽  
Yizhu Li

The use of new developed high-strength steel in concrete members can reduce steel bars congestion and construction costs. This research aims to study the behavior of concrete columns reinforced with new developed high-strength steel under eccentric loading. Ten reinforced concrete columns were fabricated and tested. The test variables are transverse reinforcement amount and yield strength, eccentricity, and longitudinal reinforcement yield strength. The failure patterns are compression and tensile failure for columns subjected to small eccentricity and large eccentricity, respectively. The same level of post-peak deformability and ductility only can be obtained with lower amount of transverse reinforcement when high-strength transverse reinforcements are used in columns subjected to small eccentricity. The high-strength longitudinal reinforcement can improve bearing capacity and post-peak deformability of concrete columns. Besides, three different equivalent rectangular stress block (ERSB) parameters in predicting bearing capacity of columns with high-strength steel were discussed based on test and simulated results. It is concluded that the Code of GB 50010-2010 overestimates the bearing capacity of columns with high-strength steel, whereas bearing capacities computed using Codes of ACI 318-14 and CSA A23.3-04 agree well with test results.


Materials ◽  
2021 ◽  
Vol 14 (22) ◽  
pp. 6860
Author(s):  
Jun Wang ◽  
Yuxin Duan ◽  
Yifan Wang ◽  
Xinran Wang ◽  
Qi Liu

To investigate the applicability of the methods for calculating the bearing capacity of high-strength steel-reinforced concrete (SRC) composite columns according to specifications and the effect of confinement of stirrups and steel on the bearing capacity of SRC columns. The axial compression tests were conducted on 10 high-strength SRC columns and 4 ordinary SRC columns. The influences of the steel strength grade, the steel ratio, the types of stirrups and slenderness ratio on the bearing capacity of such members were examined. The analysis results indicate that using high-strength steel and improving the steel ratio can significantly enhance the bearing capacity of the SRC columns. When the slenderness ratio increases dramatically, the bearing capacity of the SRC columns plummets. As the confinement effect of the stirrups on the concrete improves, the utilization ratio of the high-strength steel in the SRC columns increases. Furthermore, the results calculated by AISC360-19(U.S.), EN1994-1-1-2004 (Europe), and JGJ138-2016(China) are too conservative compared with test results. Finally, a modified formula for calculating the bearing capacity of the SRC columns is proposed based on the confinement effect of the stirrups and steel on concrete. The results calculated by the modified formula and the finite element modeling results based on the confinement effect agree well with the test results.


2020 ◽  
Vol 20 (06) ◽  
pp. 2040007
Author(s):  
Limeng Zhu ◽  
Haipeng Yan ◽  
Po-Chien Hsiao ◽  
Jianhua Zhang

An innovative composite vertical connecting structure (CVC) with capacity carrying and energy-dissipating ability is proposed in this study, which could be used in prefabricated composite shear wall structural systems to enhance the resilience and seismic performance of structural system. The CVC structure is mainly composed of three parts, including the connecting zone, the capacity bearing zone characterized by high strength and elastic deforming ability, and the energy-dissipating zone assembled by replaceable metal dampers. The low-yield strength steel and high-strength steel are used, respectively, for the metal dampers in the energy-dissipating zone and the concrete-filled high-strength steel tubes in the bearing capacity zone to enhance the energy dissipation and self-centering abilities of CVC structures. The working mechanism is analyzed and validated through finite element models built in ABAQUS. The hysteretic behavior is simulated to evaluate their performance. First, the metal dampers are designed. The theoretical and finite elemental parametric analysis are carried out. According to the simulation results, the “Z-shaped” metal dampers exhibit better energy-dissipating ability than the rectangular shape, in which the “Z-shaped” metal dampers with 45∘ show the best performance. Simultaneously, the results of the models calculated by the finite element method and theoretical analysis work very well with each other. Furthermore, seven FE models of shear walls with CVC structures are designed. Monotonic and cyclic loading simulations are conducted. The failure modes and comprehensive mechanical performance are investigated and evaluated according to their calculated force–displacement curves, skeleton curves, and ductility coefficients. The results indicate that the CVC structure delivered preferable lateral-bearing capacity and displacement ductility. Finally, according to available design standards, the lateral stiffness of CVC structures could be conventionally controlled and some practical design recommendations are discussed.


Materials ◽  
2019 ◽  
Vol 12 (13) ◽  
pp. 2139 ◽  
Author(s):  
Yonghui Hou ◽  
Shuangyin Cao ◽  
Xiangyong Ni ◽  
Yizhu Li

The use of new developed high-strength steel in concrete members can reduce steel bar congestion and construction costs. This research aims to study the behavior of concrete columns reinforced with new developed high-strength steel under eccentric loading. Ten reinforced concrete columns were fabricated and tested. The test variables were the transverse reinforcement amount and yield strength, eccentricity, and longitudinal reinforcement yield strength. The failure patterns were compression and tensile failure for columns subjected to small eccentricity and large eccentricity, respectively. The same level of post-peak deformability and ductility could only be obtained with a lower amount of transverse reinforcement when high-strength transverse reinforcements were used in columns subjected to small eccentricity. The high-strength longitudinal reinforcement improved the bearing capacity and post-peak deformability of the concrete columns. Furthermore, three different equivalent rectangular stress block (ERSB) parameters for predicting the bearing capacity of columns with high-strength steel are discussed based on test and simulated results. It is concluded that the China Code GB 50010-2010 overestimates the bearing capacity of columns with high-strength steel, whereas the bearing capacities computed using the America Code ACI 318-14 and Canada Code CSA A23.3-04 agree well with the test results.


2012 ◽  
Vol 446-449 ◽  
pp. 981-988
Author(s):  
Zhen Bao Li ◽  
Wen Jing Wang ◽  
Wei Jing Zhang ◽  
Yun Da Shao ◽  
Bing Zhang ◽  
...  

Axial compression experiments of four full-scale reinforced concrete columns of two groups were carried out. One group of three columns used high-strength steel with the yield strength of 1000MPa as reinforcement hoops, and the second group used the ordinary-strength steel with yield strength of 400MPa. The axial compressive performances between these two groups were assessed. Compared to the specimen using the ordinary-strength steel, the axial compressive bearing capacity of using the high strength steel dose not increase significantly, while the deformation ability increases greatly. The results also indicate that the stress redistributions of the hoops and the concrete sections are obvious, and long-lasting when specimens achieve the ultimate bearing capacity after the yield of the rebar and local damage of concrete materials, at this time the strain of the specimens developes a lot, especially stress - strain curves of speciments with high-strength hoop all show a wide and flat top.