Rapid Detection of Melamine in Milk Powder by near Infrared Spectroscopy

2009 ◽  
Vol 17 (2) ◽  
pp. 59-67 ◽  
Author(s):  
Chenghui Lu ◽  
Bingren Xiang ◽  
Gang Hao ◽  
Jianping Xu ◽  
Zhengwu Wang ◽  
...  

This paper establishes a novel and rapid method for detecting pure melamine in milk powder using near infrared (NIR) spectroscopy based on least squares-support vector machine (LS-SVM). Partial least square discriminant analysis (PLS-DA) was used for the extraction of principal components (PCs). The scores of the first two PCs have been applied as inputs to LS-SVM. Compared to PLS-DA, the performance of LS-SVM was better, with higher classification accuracy, both 100% for the training and testing set. The detection limit was lower than 1 ppm. Based on the results, it was concluded that NIR spectroscopy combined with LS-SVM could be used as a rapid and accurate method for detecting pure melamine in milk powder.

2011 ◽  
Vol 460-461 ◽  
pp. 667-672
Author(s):  
Yun Zhao ◽  
Xing Xu ◽  
Yong He

The main objective of this paper is to classify four kinds of automobile lubricant by near-infrared (NIR) spectral technology and to observe whether NIR spectroscopy could be used for predicting water content. Principle component analysis (PCA) was applied to reduce the information from the spectral data and first two PCs were used to cluster the samples. Partial least square (PLS), least square support vector machine (LS-SVM), and Gaussian processes classification (GPC) were employed to develop prediction models. There were 120 samples for training set and test set. Two LS-SVM models with first five PCs and first six PCs were built, respectively, and accuracy of the model with five PCs is adequate with less calculation. The results from the experiment indicate that the LS-SVM model outperforms the PLS model and GPC model outperforms the LS-SVM model.


2020 ◽  
Vol 28 (5-6) ◽  
pp. 255-266 ◽  
Author(s):  
Elise A Kho ◽  
Jill N Fernandes ◽  
Andrew C Kotze ◽  
Glen P Fox ◽  
Maggy Lord ◽  
...  

Heavy infestations of the blood-sucking gastrointestinal nematodes, Haemonchus contortus can cause severe anaemia in sheep and leakage of blood into the faeces, leading to morbidity and mortality. Early and accurate diagnosis of infections is critical for timely treatment of sheep, minimizing production and sheep welfare impacts. In pursuit of a quick and easy measure of H. contortus infections, we investigated the use of portable visible near infrared spectrometers for detecting the presence of haemoglobin in sheep faeces as an indicator of H. contortus infection. Calibration models built within the 400–600 nm region by partial least square regression resulted in acceptable prediction accuracies (r 2 p > 0.70 and root mean squared error of prediction <2.64 µg Hb mg−1 faeces) for haemoglobin quantification using two spectrometers. The prediction results from support vector machine regression further improved the prediction of haemoglobin in moist sheep faeces (r 2 p > 0.87 and root mean squared error of prediction <2.00 µg haemoglobin mg−1 faeces). Based on a threshold for anthelmintic treatment of 3 µg Hb mg−1 faeces, both the partial least square and support vector machine models showed high sensitivity (89%) and high specificity (>77%). The specificity of the prediction model for detecting haemoglobin in sheep faeces may be improved by adding more variations in faecal composition into the calibration model. Our success in detecting haemoglobin in sheep faeces, following minimal sample preparation, suggests that with further development, vis–near infrared spectroscopy can provide a sensitive and convenient method for on-farm diagnosis of H. contortus infections.


2020 ◽  
Vol 16 ◽  
Author(s):  
Linqi Liu ◽  
JInhua Luo ◽  
Chenxi Zhao ◽  
Bingxue Zhang ◽  
Wei Fan ◽  
...  

BACKGROUND: Measuring medicinal compounds to evaluate their quality and efficacy has been recognized as a useful approach in treatment. Rhubarb anthraquinones compounds (mainly including aloe-emodin, rhein, emodin, chrysophanol and physcion) are its main effective components as purgating drug. In the current Chinese Pharmacopoeia, the total anthraquinones content is designated as its quantitative quality and control index while the content of each compound has not been specified. METHODS: On the basis of forty rhubarb samples, the correlation models between the near infrared spectra and UPLC analysis data were constructed using support vector machine (SVM) and partial least square (PLS) methods according to Kennard and Stone algorithm for dividing the calibration/prediction datasets. Good models mean they have high correlation coefficients (R2) and low root mean squared error of prediction (RMSEP) values. RESULTS: The models constructed by SVM have much better performance than those by PLS methods. The SVM models have high R2 of 0.8951, 0.9738, 0.9849, 0.9779, 0.9411 and 0.9862 that correspond to aloe-emodin, rhein, emodin, chrysophanol, physcion and total anthraquinones contents, respectively. The corresponding RMSEPs are 0.3592, 0.4182, 0.4508, 0.7121, 0.8365 and 1.7910, respectively. 75% of the predicted results have relative differences being lower than 10%. As for rhein and total anthraquinones, all of the predicted results have relative differences being lower than 10%. CONCLUSION: The nonlinear models constructed by SVM showed good performances with predicted values close to the experimental values. This can perform the rapid determination of the main medicinal ingredients in rhubarb medicinal materials.


Foods ◽  
2021 ◽  
Vol 10 (4) ◽  
pp. 885
Author(s):  
Sergio Ghidini ◽  
Luca Maria Chiesa ◽  
Sara Panseri ◽  
Maria Olga Varrà ◽  
Adriana Ianieri ◽  
...  

The present study was designed to investigate whether near infrared (NIR) spectroscopy with minimal sample processing could be a suitable technique to rapidly measure histamine levels in raw and processed tuna fish. Calibration models based on orthogonal partial least square regression (OPLSR) were built to predict histamine in the range 10–1000 mg kg−1 using the 1000–2500 nm NIR spectra of artificially-contaminated fish. The two models were then validated using a new set of naturally contaminated samples in which histamine content was determined by conventional high-performance liquid chromatography (HPLC) analysis. As for calibration results, coefficient of determination (r2) > 0.98, root mean square of estimation (RMSEE) ≤ 5 mg kg−1 and root mean square of cross-validation (RMSECV) ≤ 6 mg kg−1 were achieved. Both models were optimal also in the validation stage, showing r2 values > 0.97, root mean square errors of prediction (RMSEP) ≤ 10 mg kg−1 and relative range error (RER) ≥ 25, with better results showed by the model for processed fish. The promising results achieved suggest NIR spectroscopy as an implemental analytical solution in fish industries and markets to effectively determine histamine amounts.


2021 ◽  
pp. 096703352098731
Author(s):  
Adenilton C da Silva ◽  
Lívia PD Ribeiro ◽  
Ruth MB Vidal ◽  
Wladiana O Matos ◽  
Gisele S Lopes

The use of alcohol-based hand sanitizers is recommended as one of several strategies to minimize contamination and spread of the COVID-19 disease. Current reports suggest that the virucidal potential of ethanol occurs at concentrations close to 70%. Traditional methods of verifying the ethanol concentration in such products invite potential errors due to the viscosity of chemical components or may be prohibitively expensive to undertake in large demand. Near infrared (NIR) spectroscopy and chemometrics have already been used for the determination of ethanol in other matrices and present an alternative fast and reliable approach to quality control of alcohol-based hand sanitizers. In this study, a portable NIR spectrometer combined with classification chemometric tools, i.e., partial least square discriminant analysis (PLS–DA) and linear discriminant analysis with successive algorithm projection (SPA–LDA) were used to construct models to identify conforming and non-conforming commercial and laboratory synthesized hand sanitizer samples. Principal component analysis (PCA) was applied in an exploratory data study. Three principal components accounted for 99% of data variance and demonstrate clustering of conforming and non-conforming samples. The PLS–DA and SPA–LDA classification models presented 77 and 100% of accuracy in cross/internal validation respectively and 100% of accuracy in the classification of test samples. A total of 43% commercial samples evaluated using the PLS–DA and SPA–LDA presented ethanol content non-conforming for hand sanitizer gel. These results indicate that use of NIR spectroscopy and chemometrics is a promising strategy, yielding a method that is fast, portable, and reliable for discrimination of alcohol-based hand sanitizers with respect to conforming and non-conforming ethanol concentrations.


1995 ◽  
Vol 78 (3) ◽  
pp. 802-806 ◽  
Author(s):  
José Louis Rodriguez-Otero ◽  
Maria Hermida ◽  
Alberto Cepeda

Abstract Near-infrared reflectance (NIR) spectroscopy was used to analyze fat, protein, and total solids in cheese without any sample treatment. A set of 92 samples of cow’s milk cheese was used for instrument calibration by principal components analysis and modified partial least-square regression. The following statistical values were obtained: standard error of calibration (SEC) = 0.388 and squared correlation coefficient (R2) = 0.99 for fat, SEC = 0.397 and R2 = 0.98 for protein, and SEC = 0.412 and R2 = 0.99 for total solids. To validate the calibration, an independent set of 25 cheese samples of the same type was used. Standard errors of validation were 0.47,0.50, and 0.61 for fat, protein, and total solids, respectively, and hf for the regression of measurements by reference methods versus measurements by NIR spectroscopy was 0.98 for the 3 components.


Poljoprivreda ◽  
2019 ◽  
Vol 25 (1) ◽  
pp. 48-55
Author(s):  
Marina Vranić ◽  
Marko Petek ◽  
Krešimir Bošnjak ◽  
Boris Lazarević ◽  
Klaudija Carović Stanko

In this study, near-infrared spectroscopy (NIRS) was used to predict the contents of essential macro- and microelements in common bean (Phaseolus vulgaris L.) accessions of most widespread Croatian landraces. Total of 175 samples were used for the model development by modified partial least square (MPLS), principal component regression (PCR) and partial least square (PLS) techniques. Based on the coefficients of determination (R2), standard error of calibration (SEC) and error of prediction (SEP) the models developed were (i) nearly applicable for nitrogen (N) (0.89, 0.12 and 0.45 respectively), (ii) poor for iron (Fe), cinc (Zn), potassium oxide (K2O) and potassium (K), (iii) usable for phosphorus pentoxide (P2O5), phosphorus (P), phytic acid (PA) and manganese (Mn). The MPLS regression statistics suggested the most accurate models developed comparing with PLS and PCR. It was concluded that a wider set of common bean samples needs to be used for macro- and microelements prediction by NIRS.


2018 ◽  
Vol 56 (9) ◽  
pp. 1551-1558 ◽  
Author(s):  
Tinne Monteyne ◽  
Renaat Coopman ◽  
Antoine S. Kishabongo ◽  
Jonas Himpe ◽  
Bruno Lapauw ◽  
...  

Abstract Background: Glycated keratin allows the monitoring of average tissue glucose exposure over previous weeks. In the present study, we wanted to explore if near-infrared (NIR) spectroscopy could be used as a non-invasive diagnostic tool for assessing glycation in diabetes mellitus. Methods: A total of 52 patients with diabetes mellitus and 107 healthy subjects were enrolled in this study. A limited number (n=21) of nails of healthy subjects were glycated in vitro with 0.278 mol/L, 0.556 mol/L and 0.833 mol/L glucose solution to study the effect of glucose on the nail spectrum. Consequently, the nail clippings of the patients were analyzed using a Thermo Fisher Antaris II Near-IR Analyzer Spectrometer and near infrared (NIR) chemical imaging. Spectral classification (patients with diabetes mellitus vs. healthy subjects) was performed using partial least square discriminant analysis (PLS-DA). Results: In vitro glycation resulted in peak sharpening between 4300 and 4400 cm−1 and spectral variations at 5270 cm−1 and between 6600 and 7500 cm−1. Similar regions encountered spectral deviations during analysis of the patients’ nails. Optimization of the spectral collection parameters was necessary in order to distinguish a large dataset. Spectra had to be collected at 16 cm−1, 128 scans, region 4000–7500 cm−1. Using standard normal variate, Savitsky-Golay smoothing (7 points) and first derivative preprocessing allowed for the prediction of the test set with 100% correct assignments utilizing a PLS-DA model. Conclusions: Analysis of protein glycation in human fingernail clippings with NIR spectroscopy could be an alternative affordable technique for the diagnosis of diabetes mellitus.


Sign in / Sign up

Export Citation Format

Share Document