scholarly journals Analysis of protein glycation in human fingernail clippings with near-infrared (NIR) spectroscopy as an alternative technique for the diagnosis of diabetes mellitus

2018 ◽  
Vol 56 (9) ◽  
pp. 1551-1558 ◽  
Author(s):  
Tinne Monteyne ◽  
Renaat Coopman ◽  
Antoine S. Kishabongo ◽  
Jonas Himpe ◽  
Bruno Lapauw ◽  
...  

Abstract Background: Glycated keratin allows the monitoring of average tissue glucose exposure over previous weeks. In the present study, we wanted to explore if near-infrared (NIR) spectroscopy could be used as a non-invasive diagnostic tool for assessing glycation in diabetes mellitus. Methods: A total of 52 patients with diabetes mellitus and 107 healthy subjects were enrolled in this study. A limited number (n=21) of nails of healthy subjects were glycated in vitro with 0.278 mol/L, 0.556 mol/L and 0.833 mol/L glucose solution to study the effect of glucose on the nail spectrum. Consequently, the nail clippings of the patients were analyzed using a Thermo Fisher Antaris II Near-IR Analyzer Spectrometer and near infrared (NIR) chemical imaging. Spectral classification (patients with diabetes mellitus vs. healthy subjects) was performed using partial least square discriminant analysis (PLS-DA). Results: In vitro glycation resulted in peak sharpening between 4300 and 4400 cm−1 and spectral variations at 5270 cm−1 and between 6600 and 7500 cm−1. Similar regions encountered spectral deviations during analysis of the patients’ nails. Optimization of the spectral collection parameters was necessary in order to distinguish a large dataset. Spectra had to be collected at 16 cm−1, 128 scans, region 4000–7500 cm−1. Using standard normal variate, Savitsky-Golay smoothing (7 points) and first derivative preprocessing allowed for the prediction of the test set with 100% correct assignments utilizing a PLS-DA model. Conclusions: Analysis of protein glycation in human fingernail clippings with NIR spectroscopy could be an alternative affordable technique for the diagnosis of diabetes mellitus.

Foods ◽  
2021 ◽  
Vol 10 (4) ◽  
pp. 885
Author(s):  
Sergio Ghidini ◽  
Luca Maria Chiesa ◽  
Sara Panseri ◽  
Maria Olga Varrà ◽  
Adriana Ianieri ◽  
...  

The present study was designed to investigate whether near infrared (NIR) spectroscopy with minimal sample processing could be a suitable technique to rapidly measure histamine levels in raw and processed tuna fish. Calibration models based on orthogonal partial least square regression (OPLSR) were built to predict histamine in the range 10–1000 mg kg−1 using the 1000–2500 nm NIR spectra of artificially-contaminated fish. The two models were then validated using a new set of naturally contaminated samples in which histamine content was determined by conventional high-performance liquid chromatography (HPLC) analysis. As for calibration results, coefficient of determination (r2) > 0.98, root mean square of estimation (RMSEE) ≤ 5 mg kg−1 and root mean square of cross-validation (RMSECV) ≤ 6 mg kg−1 were achieved. Both models were optimal also in the validation stage, showing r2 values > 0.97, root mean square errors of prediction (RMSEP) ≤ 10 mg kg−1 and relative range error (RER) ≥ 25, with better results showed by the model for processed fish. The promising results achieved suggest NIR spectroscopy as an implemental analytical solution in fish industries and markets to effectively determine histamine amounts.


2021 ◽  
pp. 096703352098731
Author(s):  
Adenilton C da Silva ◽  
Lívia PD Ribeiro ◽  
Ruth MB Vidal ◽  
Wladiana O Matos ◽  
Gisele S Lopes

The use of alcohol-based hand sanitizers is recommended as one of several strategies to minimize contamination and spread of the COVID-19 disease. Current reports suggest that the virucidal potential of ethanol occurs at concentrations close to 70%. Traditional methods of verifying the ethanol concentration in such products invite potential errors due to the viscosity of chemical components or may be prohibitively expensive to undertake in large demand. Near infrared (NIR) spectroscopy and chemometrics have already been used for the determination of ethanol in other matrices and present an alternative fast and reliable approach to quality control of alcohol-based hand sanitizers. In this study, a portable NIR spectrometer combined with classification chemometric tools, i.e., partial least square discriminant analysis (PLS–DA) and linear discriminant analysis with successive algorithm projection (SPA–LDA) were used to construct models to identify conforming and non-conforming commercial and laboratory synthesized hand sanitizer samples. Principal component analysis (PCA) was applied in an exploratory data study. Three principal components accounted for 99% of data variance and demonstrate clustering of conforming and non-conforming samples. The PLS–DA and SPA–LDA classification models presented 77 and 100% of accuracy in cross/internal validation respectively and 100% of accuracy in the classification of test samples. A total of 43% commercial samples evaluated using the PLS–DA and SPA–LDA presented ethanol content non-conforming for hand sanitizer gel. These results indicate that use of NIR spectroscopy and chemometrics is a promising strategy, yielding a method that is fast, portable, and reliable for discrimination of alcohol-based hand sanitizers with respect to conforming and non-conforming ethanol concentrations.


1995 ◽  
Vol 78 (3) ◽  
pp. 802-806 ◽  
Author(s):  
José Louis Rodriguez-Otero ◽  
Maria Hermida ◽  
Alberto Cepeda

Abstract Near-infrared reflectance (NIR) spectroscopy was used to analyze fat, protein, and total solids in cheese without any sample treatment. A set of 92 samples of cow’s milk cheese was used for instrument calibration by principal components analysis and modified partial least-square regression. The following statistical values were obtained: standard error of calibration (SEC) = 0.388 and squared correlation coefficient (R2) = 0.99 for fat, SEC = 0.397 and R2 = 0.98 for protein, and SEC = 0.412 and R2 = 0.99 for total solids. To validate the calibration, an independent set of 25 cheese samples of the same type was used. Standard errors of validation were 0.47,0.50, and 0.61 for fat, protein, and total solids, respectively, and hf for the regression of measurements by reference methods versus measurements by NIR spectroscopy was 0.98 for the 3 components.


Poljoprivreda ◽  
2019 ◽  
Vol 25 (1) ◽  
pp. 48-55
Author(s):  
Marina Vranić ◽  
Marko Petek ◽  
Krešimir Bošnjak ◽  
Boris Lazarević ◽  
Klaudija Carović Stanko

In this study, near-infrared spectroscopy (NIRS) was used to predict the contents of essential macro- and microelements in common bean (Phaseolus vulgaris L.) accessions of most widespread Croatian landraces. Total of 175 samples were used for the model development by modified partial least square (MPLS), principal component regression (PCR) and partial least square (PLS) techniques. Based on the coefficients of determination (R2), standard error of calibration (SEC) and error of prediction (SEP) the models developed were (i) nearly applicable for nitrogen (N) (0.89, 0.12 and 0.45 respectively), (ii) poor for iron (Fe), cinc (Zn), potassium oxide (K2O) and potassium (K), (iii) usable for phosphorus pentoxide (P2O5), phosphorus (P), phytic acid (PA) and manganese (Mn). The MPLS regression statistics suggested the most accurate models developed comparing with PLS and PCR. It was concluded that a wider set of common bean samples needs to be used for macro- and microelements prediction by NIRS.


2020 ◽  
Vol 2020 ◽  
pp. 1-9
Author(s):  
Mohd Yusop Nurida ◽  
Dolmat Norfadilah ◽  
Mohd Rozaiddin Siti Aishah ◽  
Chan Zhe Phak ◽  
Syafiqa M. Saleh

The analytical methods for the determination of the amine solvent properties do not provide input data for real-time process control and optimization and are labor-intensive, time-consuming, and impractical for studies of dynamic changes in a process. In this study, the potential of nondestructive determination of amine concentration, CO2 loading, and water content in CO2 absorption solvent in the gas processing unit was investigated through Fourier transform near-infrared (FT-NIR) spectroscopy that has the ability to readily carry out multicomponent analysis in association with multivariate analysis methods. The FT-NIR spectra for the solvent were captured and interpreted by using suitable spectra wavenumber regions through multivariate statistical techniques such as partial least square (PLS). The calibration model developed for amine determination had the highest coefficient of determination (R2) of 0.9955 and RMSECV of 0.75%. CO2 calibration model achieved R2 of 0.9902 with RMSECV of 0.25% whereas the water calibration model had R2 of 0.9915 with RMSECV of 1.02%. The statistical evaluation of the validation samples also confirmed that the difference between the actual value and the predicted value from the calibration model was not significantly different and acceptable. Therefore, the amine, CO2, and water models have given a satisfactory result for the concentration determination using the FT-NIR technique. The results of this study indicated that FT-NIR spectroscopy with chemometrics and multivariate technique can be used for the CO2 solvent monitoring to replace the time-consuming and labor-intensive conventional methods.


2012 ◽  
Vol 500 ◽  
pp. 832-837 ◽  
Author(s):  
Tao Pan ◽  
Wei Wei Chen ◽  
Wen Jie Huang ◽  
Rui Tuo Qu

A directly rapid quantitative analysis method for chemical oxygen demand (COD) of wastewater samples was established by near-infrared (NIR) spectroscopy and partial least square (PLS) method. The optimization of Savitzky-Golay (SG) smoothing modes combined with PLS factor was applied to optimize the model of NIR spectroscopy analysis here. The waveband used for modeling was the combination of 400-1878 nm and 2088-2338 nm. The optimal smoothing parameters were the 5th derivative smoothing, 5th degree polynomial, 17 smoothing points, the optimal PLS factor, root mean squared error of predication (RMSEP) and correlation coefficient of predication (RP) were 7, 33.2 (mg/L) and 0.929 respectively, which was obviously superior to the direct PLS model without SG smoothing and ones based on the whole spectral collecting region 400-2500 nm. This demonstrated that NIR spectroscopy can be applied to the rapid determination of COD of wastewater, large-scale simultaneous optimization selection of SG smoothing parameters and PLS factor can be effectively applied to the model optimization of NIR analysis.


2011 ◽  
Vol 460-461 ◽  
pp. 667-672
Author(s):  
Yun Zhao ◽  
Xing Xu ◽  
Yong He

The main objective of this paper is to classify four kinds of automobile lubricant by near-infrared (NIR) spectral technology and to observe whether NIR spectroscopy could be used for predicting water content. Principle component analysis (PCA) was applied to reduce the information from the spectral data and first two PCs were used to cluster the samples. Partial least square (PLS), least square support vector machine (LS-SVM), and Gaussian processes classification (GPC) were employed to develop prediction models. There were 120 samples for training set and test set. Two LS-SVM models with first five PCs and first six PCs were built, respectively, and accuracy of the model with five PCs is adequate with less calculation. The results from the experiment indicate that the LS-SVM model outperforms the PLS model and GPC model outperforms the LS-SVM model.


Sensors ◽  
2021 ◽  
Vol 21 (20) ◽  
pp. 6745
Author(s):  
Rebecca-Jo Vestergaard ◽  
Hiteshkumar Bhogilal Vasava ◽  
Doug Aspinall ◽  
Songchao Chen ◽  
Adam Gillespie ◽  
...  

The absorbance spectra for air-dried and ground soil samples from Ontario, Canada were collected in the visible and near-infrared (VIS-NIR) region from 343 to 2200 nm. The study examined thirteen combination of six preprocessing (1st derivative, 2nd derivative, Savitzky-Golay, Gap, SNV and Detrend) method included in ‘prospectr’ R package along with four modeling approaches: partial least square regression (PLSR), cubist, random forest (RF), and extreme learning machine (ELM) for prediction of the soil organic matter (SOM). The 1st derivative + gap, 2nd derivative + gap and standard normal variance (SNV) were the best preprocessing algorithms. Thus, only these three preprocessing algorithms along with four modeling approaches were used for prediction of soil pH, electrical conductively (EC), %sand, %silt, %clay, %very coarse sand (VCS), %coarse sand (CS), %medium sand (ms) and %fine sand (fs). The results showed that OM, pH, %sand, %silt and %CS were all predicted with confidence (R2 > 0.60) and the combination of 1st derivative + gap and RF gained the best performance. A detailed comparison of the preprocessing and modeling algorithms for various soil properties in this study demonstrate that for better prediction of soil properties using VIS-NIR spectroscopy requires different preprocessing and modeling algorithms. However, in general RF and 1st derivative + gap can be labeled at the best combination of preprocessing and modelling algorithms.


2012 ◽  
Vol 262 ◽  
pp. 59-64
Author(s):  
Hong Wei Lu ◽  
Hong He ◽  
Jun Ji ◽  
Guo Qiang Liu ◽  
Ying Hu

For the fast and exact detection of printing color, we combine the near infrared (NIR) spectroscopy technique with partial least square (PLS) to build the detection model of printing color. Applying the 144 samples of spectral curve which obtained by the near infrared spectroscopy randomly separated into calibration set and validation set, and base on the 120 calibration set data to establish the prediction model of printing color by PLS, then this model is employed for predicting the color of the 24 validation set. The RMSEC of the 24 blocks’ color parameters L*, a*, b*, E are 0.73, 2.26, 3.03 and 1.09 respectively; The RMSEP are 0.97, 2.77, 3.57 and 1.34 respectively. Those results tell that the NIR spectrum and blocks’ color parameters L*, a*, b*, E could accurately establish a quantitative regression model, applying such model also can accurately predict unknown samples, and the results approximate to the original reference data. The use of near infrared spectroscopy to detect the printed matter nondestructively is feasible, and lays the foundation for the further analysis and establishment of printing chroma model.


2017 ◽  
Vol 31 (34) ◽  
pp. 1750327
Author(s):  
Li-Na Li ◽  
Chang-Ming Ma ◽  
Ming Chang ◽  
Ren-Cheng Zhang

A novel method based on SIMPLe-to-use Interactive Self-modeling Mixture Analysis (SIMPLISMA) and Kernel Partial Least Square (KPLS), named as SIMPLISMA-KPLS, is proposed in this paper for selection of outlier samples and informative samples simultaneously. It is a quick algorithm used to model standardization (or named as model transfer) in near infrared (NIR) spectroscopy. The NIR experiment data of the corn for analysis of the protein content is introduced to evaluate the proposed method. Piecewise direct standardization (PDS) is employed in model transfer. And the comparison of SIMPLISMA-PDS-KPLS and KS-PDS-KPLS is given in this research by discussion of the prediction accuracy of protein content and calculation speed of each algorithm. The conclusions include that SIMPLISMA-KPLS can be utilized as an alternative sample selection method for model transfer. Although it has similar accuracy to Kennard–Stone (KS), it is different from KS as it employs concentration information in selection program. This means that it ensures analyte information is involved in analysis, and the spectra (X) of the selected samples is interrelated with concentration (y). And it can be used for outlier sample elimination simultaneously by validation of calibration. According to the statistical data results of running time, it is clear that the sample selection process is more rapid when using KPLS. The quick algorithm of SIMPLISMA-KPLS is beneficial to improve the speed of online measurement using NIR spectroscopy.