scholarly journals A Numerical Study on the Solidification and Melting of Water Around a Vertical Heat Transfer Plate with Pin Fins.

1997 ◽  
Vol 63 (615) ◽  
pp. 3722-3728
Author(s):  
Dong CHEN ◽  
Yoshio HIRASAWA ◽  
Eisyun TAKEGOSHI
2019 ◽  
Vol 29 (8) ◽  
pp. 2545-2565
Author(s):  
Safeer Hussain ◽  
Jian Liu ◽  
Lei Wang ◽  
Bengt Ake Sunden

Purpose The purpose of this paper is to enhance the heat transfer and thermal performance in the trailing edge region of the vane with vortex generators (VGs). Design/methodology/approach This numerical study presents the enhancement of thermal performance in the trailing part of a gas turbine blade. In the trailing part, generally, pin fins are used either in staggered or in-line arrangements to enhance the heat transfer. In this study, based on the idea from heat exchangers, pin fins are combined with VGs. A pair of VGs is embedded in the boundary layer upstream of each pin fin in the first row of the pin fin array having an in-line configuration. The effects of the VG angle relative to the streamwise direction and streamwise distance between the pin fin and VGs are investigated at various Reynolds numbers. Findings The results indicated that the endwall heat transfer is enhanced with the addition of VGs and the heat transfer from the surfaces of the pin fins. The level of heat transfer enhancement compared to the case without VGs is more significant at high Reynolds number. The surfaces of the VGs also show a significant amount of heat transfer. Study of the angle of the attack suggested that a high angle of attack is more appropriate for pin fin cooling enhancement whereas an intermediate gap between the VGs and pin fins shows considerable improvement of thermal performance compared to the small and large gaps. The phenomenon of heat transfer augmentation with the VGs is demonstrated by the flow field. It shows that the enhancement of heat transfer is governed by the mixing of the flow as a result of the interaction of vortices generated by the VGs and pin fins. Originality/value VGs are used to disturb the thermal boundary layer. It shows that heat transfer is augmented as a result of the interaction of vortices associated with VGs and pin fins.


Author(s):  
K. Takeishi ◽  
Y. Oda ◽  
Y. Miyake ◽  
Y. Motoda

Local endwall heat transfer characteristics and overall pressure loss of normal and inclined pin fins arrayed in rectangular ducts with flat and wavy endwalls have been investigated to improve the cooling efficiency of jet engine combustor liners. The detailed time-mean local Nusselt number profiles were measured using a naphthalene sublimation method based on the heat/mass transfer analogy. Four kinds of angled pin fins (−45, 0, and +45 degrees with a flat endwall, and −45 degrees with a wavy endwall) were tested and compared with each other. As a result, the average heat transfer coefficient on the flat endwall of normal pin fins was higher than that of the angled pin fins. The average heat transfer coefficient of −45-degree inclined pin fins with a wavy endwall is the same or a little higher than the heat transfer coefficient of those with a flat endwall; however, the pressure loss of the −45-degree inclined pin fins with a wavy endwall is less than the pressure loss of those with a flat endwall. Corresponding numerical simulations using Large Eddy Simulation (LES) with the Mixed Time Scale (MTS) model have been also conducted at Red = 1000 for fully developed regions, and the results have shown good quantitative agreement with mass transfer experiments. It can be concluded that wavy endwalls can realize better heat transfer with less pressure loss as long as the aim consists in enhancing endwall heat transfer in inclined pin-fin channels.


Author(s):  
Haleh Shafeie ◽  
Omid Abouali ◽  
Khosrow Jafarpour

This paper presents a numerical study of laminar forced convection in microchannels network heat sinks with fabricated offset pin-fins. A 3-dimensional mathematical model, for conjugate heat transfer in both solid and liquid is presented. For this aim the Navier-Stokes and energy equations for the liquid region and the energy equation for the solid region are solved simultaneously and the pressure drop together heat transfer characteristics of a single-phase microchannel heat sink were investigated. A typical microchannel was selected and it was shown that using offset pin-fins has a noticeable effect and heat removal rate can be increased using this technique. However the pressure drop is also highly increasing which leads to a low coefficient of performance for microchannel with this type of micro-structure.


Author(s):  
N. Kulasekharan ◽  
B. V. S. S. S. Prasad

A numerical investigation is carried out for estimating the influence of rib turbulators on heat transfer and pressure drop of staggered non-uniform pin-fin arrays of different shapes, in a simulated cambered vane trailing region. Pin-fins of square, circular and the diamond shapes, each of two sizes (d) were chosen. The ratio of span-wise pitch to longitudinal pitch is 1.06 and that to the pin size are 4.25 and 3.03, for all pin shapes. A constant heat flux boundary condition is assumed over the coolant channel walls, rib surfaces and circumferential faces of the pin-fins. Reynolds number is varied (20,000<ReD<40,000) by changing the coolant outlet to inlet pressure ratio. Pin end-wall and pin surface averaged heat transfer coefficients and Nusselt numbers are estimated and detailed contours of heat transfer coefficient on both the pressure and suction surfaces are presented. Whilst there is an enhancement in heat transfer and pressure drop with ribs for all the pin shapes, diamond pins have shown the highest enhancement values for both ribbed and non-ribbed configuration.


2012 ◽  
Vol 501 ◽  
pp. 376-381
Author(s):  
Yan Zhou ◽  
Wen Juan Zheng ◽  
Xi Yan Fan ◽  
Jun Chao ◽  
Qing Ling Li

The extended surface is used to enhance paraffin/air heat transfer because of the paraffin’s poor thermal conductivity, and the heat storing and releasing capacity of paraffin heat storage layer with variety of extended surface are compared by numerical simulation. The results show that: the heat storage layer with vertical rectangular fin extended surface has stronger ability on the heat storage and release, and can more effectively improve the air flow velocity in the solar chimney power plant system with vertical heat collector. Due to the restrictions of manufacturing, the heat storage and release capacity is stronger when the heat storage layer surface area with vertical rectangular fin is from 3.4 times to 5.8 times compare to the flat-plate heat storage layer.


Author(s):  
Wei Jin ◽  
Ning Jia ◽  
Junmei Wu ◽  
Jiang Lei ◽  
Lin Liu

Abstract Equipping pin-fins in the blade trailing edge is an significant method for enhancing heat transfer. In order to obtain a geometry of pin-fins with good heat transfer effect and small friction factor, six pin-fins (circular, elliptic, oblong, teardrop, lancet and NACA) are selected. The flow and heat transfer features of the rectangular channel with the staggered pin-fins were numerically studied through FLUENT software. The channels with different pin-fins have the same relative spanwise pitch (S/D = 2.5) and streamwise pitch (X/D = 2.5), and the range of Reynolds number is 5×103 to 3×104. The applicability and accuracy of five turbulence models (Standard k-ε, Realizable k-ε, RNG k-ε, Standard k-ω and SST k-ω) are checked by comparing the numerically predicted results with the experimental from literature. It is found that the Realizable k-ε model is better at capturing the microstructure of flow field and has higher precision in predicting the averaged Nusselt number on the heated surface. For the six pin-fins, the leading edge is surrounded by a “U-shaped” strong heat exchange zone, but the vortex systems in the trailing edge are different from each other. Compared to the circular pin-fin, the oblong pin-fin has the best heat transfer enhancement effect, but the friction factor of channel is also larger. While the NACA pin-fin has the lowest friction factor, and the heat transfer effect is second only to the oblong. NACA pin-fin may be applied in blade trailing edge cooling by further optimizing the relative position of the pin-fins in the channel.


Author(s):  
Xinjun Wang ◽  
Xiaowei Bai ◽  
Jiangbo Wu ◽  
Rui Liu ◽  
Ding Zhu ◽  
...  

By using the CFX software, three-dimensional flow and heat transfer characteristics in rectangular cooling ducts with in-line and staggered array pin-fins of gas turbine blade trailing edge were numerically simulated. The effects of in-line and staggered arrays of pin-fins, flow Reynolds number as well as density of cylindrical pin-fins in flow direction on heat transfer characteristics were analyzed. Both in the cases of in-line and staggered arrays of pin-fins, the results show that the pin-fin surface averaged Nusselt number increases with the increasing of Reynolds number. In the case of the same Reynolds number, the mean Nusselt number of pin-fin surface decreased with the increasing of X/D (the ratio of streamwise pin-pitch to pin-fin diameter) value. The Nusselt number increases gradually before the first pin-fin row and then reached the fully developed value at fourth or fifth row. The pin-fin Nusselt number at flow direction is larger than that at back flow direction. Along the height direction of pin-fin, the Nusselt number in middle area is larger.


Author(s):  
Muralikrishnan Gopalakrishnan Meena ◽  
Abhijith Anandakrishnan ◽  
Madhu Anandarajan Kavumcheril

Pin fins and dimples are used for enhancing heat transfer from surfaces and here we take into account their use in cooling the trailing edge of gas turbine blades. The main problem is the increase in pressure drop with increase in dimple depths. This is a vital factor for the total work done by the turbine. The models for which study has been conducted are the ones with dimple depths of 1mm, 2mm and 3mm. Also, as a modification, fillets are added to the edges of the dimples with 3mm depth. Turbulent flow with Re of about 55,000 is employed through the surface, which is heated with constant heat flux of 50,000 W/m2. The results showed that the modified model reduces the frictional loss to a large extent without creating much disturbance to the heat transfer capability of the original structure. The modified model gave the lowest amount of friction factor at the same time providing reasonable amount of heat transfer compared to the other three models.


Sign in / Sign up

Export Citation Format

Share Document