<p><strong>Objective:</strong> This in vitro study evaluated the effects of three polishing systems on the surface roughness of two ceromers. <strong>Material and Methods:</strong> 96 specimens (8 mm in diameter and 2 mm thick) were prepared in a metal mold using two restorative materials: CERAMAGE (Shofu, Japan) and VMLC VITA (VITA Zahnfabrik, Germany). The specimens were divided into 4 groups (n=12): G1: positive control, Mylar strip; G2: abrasive tips, Edenta system; G3: silicon tips, Enhance system; and G4: abrasive tips, Shofu system. The parameter evaluated was the average surface roughness (Ra) determined by using a profilometer SJ 301 (Mitutoyo, Japan), followed by photographic evaluation images through Scanning Electron Microscopy (SEM), with a 1000x magnification range. The data was subjected to statistical analysis for comparison between the groups (ANOVA, Tukey and Student T-tests), with a significance level of 5%. <strong>Results:</strong> there was a statistically significant difference between the silicone tip Enhance and the other groups for both ceromers with higher values of surface roughness. There was no statistically significant difference between the ceromers, except for the Shofu system, which showed lower values of surface roughness for Vita VMLC. <strong>Conclusion: </strong>Within the limitations of this study, it was concluded that the Edenta and Shofu abrasive tips are more effective in reducing the surface roughness of ceromers compared with the Enhance silicone tip.</p><p><strong>Keywords:</strong> Resins; Surface roughness; Dental polishing.</p>

2020 ◽  
Vol 11 (2) ◽  
pp. 180-188
Author(s):  
Hüsniye Gümüş ◽  
Mustafa Aydınbelge ◽  
Hayriye Sönmez

Aim: To analyze the remineralization efficacy of casein phosphopeptide–amorphous calcium phosphate (CPP–ACP) and 8% arginine on artificial early enamel lesions on primary teeth enamel samples. Materials and Methods: In this in vitro study, artificial enamel lesions were created in 120 primary teeth. Teeth were randomly divided into 5 groups: group C: CPP–ACP paste; group CF: CPP–ACPF paste with 900 ppm flour; group A: paste with 8% arginine; group K+: 500 ppm NaF as a positive control; and group K–: deionized water as a negative control. After 4 weeks of the remineralization process, the effect of remineralization on samples of agents used the microhardness, atomic force microscope, and scanning electron microscope analyses. Statistical analysis was done using Statistical Package for the Social Sciences (SPSS version 20.0, SPSS Inc., Chicago, IL, USA). ANOVA and Tukey Post-Hoc multiple comparison test were applied ( p < .05). Results: Increasing percentage values of the microhardness at groups C, CF, and A were significantly better than group K– ( p < .05), whereas there is no statistically significant difference with group K+ ( p > .05). The average surface roughness values of groups C and CF were similar with group K+ in AFM analysis, whereas average surface roughness values of group A were significantly higher than K+ group. Conclusion: The CPP–ACP, CPP–ACPF, and arginine are effective agents for remineralization of early childhood caries lesions.


2018 ◽  
Vol 20 (4) ◽  
pp. 238
Author(s):  
Júlia Bazaga Ferreira ◽  
Gabriella Rodovalho Paiva ◽  
Vinícius Rangel Geraldo-Martins ◽  
Juliana Jendiroba Faraoni ◽  
Regina Guenka Palma Dibb ◽  
...  

O objetivo deste trabalho in vitro foi avaliar a influência de diferentes agentes remineralizantes no tratamento de lesões erosivas em esmalte. Foram confeccionados espécimes de 4mmx4mm e 3 mm de espessura a partir da superfície vestibular de incisivos bovinos (n=10) e divididos aleatoriamente em 4 grupos. G1=aplicação do dentifrício remineralizante, G2= aplicação do agente potencializador remineralizante, G3= dentifrício remineralizante + agente potencializador remineralizante, G4=aplicação de verniz fluoretado (controle positivo), G5=nenhum tratamento (controle negativo). Os espécimes foram imersos em refrigerante durante um período de 10 dias. A rugosidade superficial foi analisada por meio de microscopia confocal de varredura a laser. Os dados foram analisados quanto à homogeneidade (Levene’s) e normalidade (Kolmogorov- Smirnov). Foram realizados testes paramétricos com análise de variância a dois critérios: fator tempo e fator tratamento, e pós-teste de Tukey para diferenciação das médias. Todos os testes estatísticos tiveram nível de significância de 5% (α=0,05). Os resultados obtidos mostraram diferenças estatisticamente significantes, demonstrando a redução da rugosidade da superfície do esmalte logo após o primeiro tratamento (G3) e para os demais grupos (G1, G2 e G4) somente após o segundo tratamento. Concluiu-se que a utilização de dentifrício composto por silicato de cálcio e fosfato de sódio influenciou na rugosidade do esmalte erodido do dente bovino.Palavras-chave: Dentifrícios. Erosão Dentária. Esmalte Dentário.Abstract The objective of this in vitro study was to evaluate the influence of different remineralizing agents in the treatment of enamel erosive lesions. Specimens of 4mmx4mm and 3mm thickness were made from the buccal surface of bovine incisors (n=10) and randomly divided into 4 groups. G1 = application of the remineralizing dentifrice, G2 = application of the remineralizing agent, G3 = remineralizing dentifrice + remineralizing agente, G4 = application of fluoride varnish (positive control), G5 = no treatment Specimens were immersed in refrigerant solution during a period of 10 days. The surface roughness was analyzed by means of confocal laser scanning microscopy. The data were analyzed for homogeneity (Levene's) and normality (Kolmogorov-Smirnov). Parametric tests with analysis of variance were performed on two criteria: time factor and treatment factor, and Tukey post-test for differentiation of means. All tests were statistically significant at 5% (α = 0.05). The results showed statistically significant difference, demonstrating the reduction of surface roughness after the first treatment (G3) and the other groups (G1, G2 and G4) only after the second treatment. It was concluded that the use of dentifrice composed of calcium silicate and sodium phosphate influenced the roughness of the eroded tooth enamel of the bovine tooth.Keywords: Dentifrices. Tooth Erosion. Tooth Enamel.


2019 ◽  
Vol 21 (4) ◽  
pp. 365
Author(s):  
Leandro Silva Almeida ◽  
Gabriella Rodovalho Paiva ◽  
Vinícius Rangel Geraldo-Martins ◽  
Juliana Jendiroba Faraoni ◽  
Regina Guenka Palma Dibb ◽  
...  

AbstractThe objective of this in vitro study was to evaluate the influence of the Er,Cr:YSGG laser associated or not to a desensitizing agent in the treatment of erosive lesions. Forty specimens with dimensions of 4mm x 4mm and 3mm thickness were divided into 4 groups (n = 10): G1- no treatment; G2- 5% fluoride varnish; G3- Er,Cr: YSGG; G4 - fluoride varnish + laser. The specimens were immersed in erosive drink 3 times a day for 1 minute with an average interval of 2 hours between cycles for a period of 10 days. The treatments were performed according to the groups and the surface roughness and the wear profile were analyzed by scanning confocal microscopy. The normality (Kolmogorov-Smirnov) and homogeneity (Levene's) of the tests were evaluated. After these analyzes, the surface roughness data were submitted to the statistical analysis of Variance Analysis (ANOVA). All tests adopted a significance level of 5% (α = 0.05). At the representative images of the wear profile, the morphology of bovine dental enamel in its control and eroded areas were compared and qualitatively discussed. As regard surface roughness, there was no statistically significant difference between the groups. The qualitative analysis of the loss of volume showed that all experimental groups showed significant superficial morphology differences. Considering the limitations of an in vitro study, it can be concluded that the treatments performed were not able to treat dental erosion satisfactorily, indicating the need for more treatment sessions. Keywords: Tooth Erosion. Dental Enamel. Fluoride. YSGG Laser. ResumoO objetivo desse estudo in vitro foi avaliar a influência do laser Er,Cr:YSGG associado ou não a um agente dessensibilizante no tratamento de lesões erosivas. Foram confeccionados 40 espécimes com dimensões de 4mm x 4mm e 3mm de espessura, divididos em 4 grupos (n=10): G1- nenhum tratamento; G2- verniz fluoretado 5%; G3- aplicação do laser Er,Cr:YSGG; G4- verniz fluoretado + laser. Os espécimes foram imersos em bebida erosiva, 3 vezes por dia, durante 1 minuto, com intervalo médio de 2 horas entre os ciclos, por um período de 10 dias. Os tratamentos foram realizados de acordo com os grupos e que foram analisados a rugosidade superficial e o perfil de desgaste por meio de microscopia confocal de varredura. Avaliou-se a normalidade (Kolmogorov-Smirnov) e homogeneidade (Levene’s) dos dados. Após estas análises, os dados de rugosidade superficial foram submetidos ao teste estatístico de Análise de Variância (ANOVA). Todos os testes adotaram nível de significância de 5% (α=0,05). Através da obtenção das imagens representativas do perfil desgaste, a morfologia do esmalte dental bovino em suas áreas controle e erodida foram comparadas e qualitativamente discutidas. Quanto à rugosidade superficial, não houve diferença estatisticamente significativa entre os grupos. A análise qualitativa da perda de volume mostrou que todos os grupos experimentais apresentaram diferenças significativas na morfologia superficial. Considerando as limitações de um estudo in vitro pode-se concluir que os tratamentos realizados não foram capazes de tratar a erosão dentária de forma satisfatória, indicando a necessidade de mais sessões de tratamento. Palavras-chave: Erosão dentária. Esmalte dental. Flúor. Laser de YSGG.


2012 ◽  
Vol 06 (02) ◽  
pp. 198-205 ◽  
Author(s):  
Ugur Erdemir ◽  
Hande Sar Sancakli ◽  
Esra Yildiz

ABSTRACTObjectives: The objective of this in vitro study was to evaluate the surface roughness and microhardness of three novel resin composites containing nanoparticles after polishing with one-step and conventional multi-step polishing systems.Methods: A total of 126 specimens (10 X 2 mm) were prepared in a metal mold using three nanocomposites (Filtek Supreme XT, Ceram-X, and Grandio), 21 specimens of each resin composite for both tests (n=63 for each test). Following light curing, seven specimens from each group received no polishing treatment and served as controls for both tests. The specimens were randomly polished using PoGo and Sof-Lex systems for 30 seconds after being wet-ground with 1200-grit silicon carbide paper. The mean surface roughness of each polished specimen was determined with a profilometer. The microhardness was determined using a Vickers hardness measuring instrument with a 200-g load and 15 seconds dwell time. The data were analyzed using the Kruskal-Wallis test and the post hoc Dunn's multiple comparison tests at a significance level of .05.Results: Among all materials, the smoothest surfaces were obtained under a matrix strip (control) (P<.05). There were no statistically significant differences among polishing systems in the resin composites for surface roughness (P>.05). The lowest hardness values for the three resin composites were obtained with a matrix strip, and there was a statistically significant difference compared with other polishing systems (P<.05) whereas no statistically significant differences were observed between the polishing systems (P<.05).Conclusion: The current one-step polishing system appears to be as effective as multi-step systems and may be preferable for polishing resin composite restorations. (Eur J Dent 2012;6:198-205)


2007 ◽  
Vol 8 (2) ◽  
pp. 89-96 ◽  
Author(s):  
Hacer Deniz Arisu ◽  
Mine Betül Üçtaşli ◽  
Hüma Ömürlü ◽  
Evrim Eligüzeloğlu ◽  
Suat Özcan ◽  
...  

Abstract Aim The purpose of this in vitro study was to examine the effect of two different finishing systems on the surface roughness of different types of composite restorative materials. Methods and Materials Thirty specimens, 8 mm in diameter and 3 mm in depth, were prepared using a microfill composite (Clearfil ST, Kuraray Co. Ltd., Osaka, Japan), a hybrid composite (Clearfil AP-X, Kuraray Co. Ltd., Osaka, Japan), and a packable composite (Clearfil Photo Posterior, Kuraray Co. Ltd., Osaka, Japan) cured against a Mylar matrix strip to create a baseline surface. The average surface roughness was measured using a surface profilometer (Surftest 211, Mitutoyo, Japan) in five different positions on each sample before and after finishing with one of the two finishing systems [Sof-Lex discs (3M) and Po-Go (Dentsply)]. The obtained data were analyzed by two-way analysis of variance (ANOVA) at a p=0.05 significance level. Results There were statistically significant differences in the average surface roughness (Ra, ìm) between the Mylar matrix strip, Sof-Lex discs, and Po-Go discs (p<0.05). For all tested materials, the Mylar matrix strip provided smoother surfaces than both of the finishing systems (p<0.05). When the finishing discs were compared, Sof-Lex discs produced a smoother surface than Po-Go discs for all tested materials (p<0.05). Conclusion The Mylar matrix strip provided a smoother surface than Sof-Lex and Po-Go discs. Furthermore, Sof-Lex discs produced smoother surfaces than Po-Go discs. Sof-Lex and Po-Go systems produced clinically acceptable surface roughness for microfill, hybrid, and packable composite resin materials. The effect of finishing and polishing systems on surface roughness was dependent on both the system and the composite resin restorative material. Citation Üçtaşli MB, Arisu HD, Ömürlü H, Eligüzeloğlu E, Özcan S, Ergun G. The Effect of Different Finishing and Polishing Systems on the Surface Roughness of Different Composite Restorative Materials. J Contemp Dent Pract 2007 February;(8)2:089-096.


2013 ◽  
Vol 38 (4) ◽  
pp. 429-438 ◽  
Author(s):  
TA Imbery ◽  
A Namboodiri ◽  
A Duncan ◽  
R Amos ◽  
AM Best ◽  
...  

SUMMARY This in vitro study evaluated the effect of six surface treatments on the shear bond strength of three resin-modified glass ionomers (RMGIs) to dentin. Occlusal surfaces of caries-free third molars were reduced to expose only dentin. Surface treatments were smear layer intact (negative control), Cavity Conditioner, EDTA, Ketac Primer, Self Conditioner, and etching with 35% phosphoric acid followed by the application of Optibond Solo Plus. Filtek Z250 composite resin bonded with Optibond Solo Plus served as a positive control. Conditioning agents were used according to the manufacturers' instructions. After surface treatments, Fuji II LC, Riva LC, Ketac Nano, and Filtek Z250 were placed in copper-band matrices 5 mm in diameter and 2 mm in height and were light-cured for 20 seconds. Specimens were stored in 100% humidity for 24 hours, after which they were placed in deionized water for 24 hours at 37°C. They were then tested under shear forces in an Instron Universal Testing Machine at a crosshead speed of 0.5 mm/min. A two-way analysis of variance and Tukey honestly significant difference statistical analyses (p&lt;0.05) indicated significant interaction between RMGIs and conditioning agents. Acid etching followed by Optibond Solo Plus provided highest bond strengths for all three RMGIs, which were not statistically different from the positive control.


2017 ◽  
Vol 40 (2) ◽  
pp. 82-87 ◽  
Author(s):  
Faika Y. Abdelmegid ◽  
Fouad S. Salama ◽  
Waleed M. Al-Mutairi ◽  
Saud K. Al-Mutairi ◽  
Sultan O. Baghazal

Introduction The aim of this in vitro study was to assess and compare the effect of different intermediary bases on microleakage between tooth and a nanocomposite interface in Class II box cavities in primary teeth. Methods Standard Class II box cavities were prepared in 52 primary molars and randomly divided into 9 groups according to the intermediary base used (Multicore Flow, Fuji II LC, SDR, Smart Dentin Replacement, and Biodentine). All specimens were subjected to thermocycling and prepared for microleakage testing and evaluation. Results There was significant difference in the mean ranks of microleakage between the 9 groups, which was observed in the gingival side (p<0.0001) and the occlusal side (p<0.0001). The mean ranks microleakage was significantly higher with experimental SDR, experimental Multicore Flow, and positive control materials when compared with the other 6 groups. The microleakage mean ranks were statistically significantly lower in experimental Fuji II LC, experimental Biodentine, and all negative control groups when compared with the other 3 groups. Conclusions Microleakage is affected by the application of intermediate material. Experimental Biodentine and Fuji II LC showed the lowest microleakage while experimental SDR and experimental Multicore Flow showed the highest microleakage.


2017 ◽  
Vol 2017 ◽  
pp. 1-4 ◽  
Author(s):  
Gardel Nepomuceno Costa ◽  
Elizabeth Ferreira Martinez ◽  
Aluísio Martins de Oliveira Ruellas ◽  
Daiane Cristina Peruzzo ◽  
Júlio Cesar Joly ◽  
...  

Considering the variety of implant connection systems available in the market and the contrasting literature regarding tapered connection systems in terms of bacterial leakage, the aim of this in vitro study was to compare the effectiveness of the bacterial seal at the implant/abutment interface between an external hexagon and a tapered connection system. Twelve sets of indexed tapered connection components and twelve sets of external hexagon connection components were used for microbiological analysis. In addition, for each model, an implant with its respective prosthetic abutment was used as a negative control and another as a positive control of microbial contamination. Failure of the abutment/implant interface seal was observed via turbidity or presence of deposits in the culture. Descriptive analysis of the data and relative frequency (percentage) as well as Fisher’s exact test were used at a significance level of 5%. Two of ten (20%) external hexagon specimens showed contamination against 0/10 (0%) tapered connection implants. In conclusion, both implant/abutment connections were able to prevent bacterial leakage in vitro.


2021 ◽  
Vol 58 (1) ◽  
pp. eUJ3657
Author(s):  
Germano Brandão ◽  
◽  
Liliana Ávila Maltagliati ◽  
Ana Carla Raphaelli Nahás-Scocate ◽  
Murilo Matias ◽  
...  

The objective of this in vitro study was to assess and compare the shear bond strength of conventional and modified orthodontic tubes bonded to the surface of dry and saliva-contaminated enamel. The sample consisted of 40 human teeth, which were randomly divided into four groups according to attachment base and presence or absence of saliva contamination as follows: Group CB, conventional orthodontic tubes without salivary contamination; Group CB-S, conventional orthodontic tubes with salivary contamination; Groups BM, orthodontic tubes modified by welding a metal mesh to their base without salivary contamination; and Group BM-S, modified orthodontic tubes with salivary contamination. Shear bond strength test was performed in a universal testing machine and analysis of the adhesive remnant index (ARI) by optical microscopy. Two-way ANOVA was used, followed by Tukey’s test at a statistical significance level of 5%. The ARI results were analysed descriptively. There was statistically significant difference between the groups regarding the shear bond strength values, with conventional tubes presenting significantly higher values (P < 0.05). In addition, the presence of salivary contamination interfered negatively with the behaviour of conventional tubes only (P < 0.05). Shear bond strength was not improved by increasing the area of the orthodontic tubes. Moreover, salivary contamination influenced negatively the SBS values, but only when conventional tubes were used.


2020 ◽  
Vol 8 (D) ◽  
pp. 166-172
Author(s):  
Ahmed Mohamed Elmarakby ◽  
Mahmoud Darwish ◽  
Yasser R. Souror ◽  
Ahmed Waly

AIM: The aim of the current in vitro study was to evaluate the changes in surface roughness of bulk fill composites after simulated toothbrushing with different dentifrices. MATERIALS AND METHODS: Three types of bulk fill resin composites were used in this study; 27 specimens of each composite resin were randomly divided into three main groups (n = 9). Each main group was further subdivided into three subgroups (n = 3). Each group was subjected to simulated toothbrushing with three different dentifrices. One-way analysis of variance was used to evaluate the effect of brushing using dentifrices on the surface roughness of each type of composite resin, followed by Tukey’s test at a significance level of p ≤ 0.5%. RESULTS: Results revealed that different effects on composite surface roughness were detected after simulating toothbrushing with different dentifrices. Lacalut toothpaste abrades more with Filtek Bulk Fill, Tetric N-Ceram then Bulk Fill SDR. Crest 3D toothpaste abrades more with Tetric N-Ceram, Bulk Fill SDR then Filtek Bulk Fill. BlanX toothpaste abrades more with Tetric N-Ceram, Bulk Fill SDR then Filtek Bulk Fill. CONCLUSION: Chemical composition of both resin composites and dentifrices plays an important role in influencing the degree of surface roughness of bulk fill composite resin restorations.