Urinary gonadotropin measurements by enhanced luminometric assays (LIA) for the evaluation of pubertal development

Author(s):  
And Demir ◽  
Adem Aydın ◽  
Atilla Büyükgebiz ◽  
Ulf-Håkan Stenman ◽  
Matti Hero

Abstract Objectives Determination of LH in urine has proved to be a reliable method for evaluation of pubertal development. The human LH assay based on time-resolved immunofluorometric (IFMA) technology (AutoDELFIA, PerkinElmer, Wallac) has been found to be suitable for this purpose thanks to its high sensitivity but other assays have not been evaluated. We have analyzed our data obtained by another potentially sensitive detection technique, enhanced luminometric assay (LIA) with the objective of finding a viable alternative to IFMA since these may not be available in the future. Methods LIA was used to measure LH and FSH in serum and urine samples from 100 healthy subjects of each Tanner stage and both genders, whose pubertal development has been determined. Results Urinary gonodotropin concentrations measured by LIA correlated well with Tanner stage [(r=0.93 for girls, r=0.81 for boys; p<0.01 for LH) and (r=0.81 for girls, r=0.73 for boys; p<0.01 for FSH)]. LIA determinations revealed the increase in U-LH concentrations during the transition from Tanner stage 1–2 in both girls and boys (p<0.001), whereas U-FSH and S-LH were able to detect the increase from Tanner stage 1–2 only in boys or girls, respectively (both p<0.001). Conclusions Measurement of urinary gonadotropin concentrations by LIA may be useful for the evaluation of overall pubertal development and also in the detection of transition from prepuberty to puberty.

PLoS ONE ◽  
2021 ◽  
Vol 16 (5) ◽  
pp. e0251598
Author(s):  
Mandy Goldberg ◽  
Anna J. Ciesielski Jones ◽  
John A. McGrath ◽  
Christie Barker-Cummings ◽  
Deborah S. Cousins ◽  
...  

Background Many studies investigating pubertal development use Tanner staging to assess maturation. Endocrine markers in urine and saliva may provide an objective, sensitive, and non-invasive method for assessing development. Objective Our objective was to examine whether changes in endocrine levels can indicate the onset of pubertal development prior to changes in self-rated Tanner stage. Methods Thirty-five girls and 42 boys aged 7 to 15 years were enrolled in the Growth and Puberty (GAP) study, a longitudinal pilot study conducted from 2007–2009 involving children of women enrolled in the Agricultural Health Study (AHS) in Iowa. We collected saliva and urine samples and assessed pubertal development by self-rated Tanner staging (pubic hair, breast development (girls), genital development (boys)) at three visits over six months. We measured dehydroepiandrosterone (DHEA) in saliva and creatinine-adjusted luteinizing hormone (LH), testosterone, follicle stimulating hormone (FSH), estrone 3-glucuronide (E13G) and pregnanediol 3-glucuronide (Pd3G) concentrations in first morning urine. We evaluated the relationships over time between Tanner stage and each biomarker using repeated measures analysis. Results Among girls still reporting Tanner breast stage 1 at the final visit, FSH levels increased over the 6-month follow-up period and were no longer lower than higher stage girls at the end of follow-up. We observed a similar pattern for testosterone in boys. By visit 3, boys still reporting Tanner genital stage 1 or pubic hair stage 1 had attained DHEA levels that were comparable to those among boys reporting Tanner stages 2 or 3. Conclusions Increasing concentrations of FSH in girls and DHEA and testosterone in boys over a 6-month period revealed the start of the pubertal process prior to changes in self-rated Tanner stage. Repeated, non-invasive endocrine measures may complement the more subjective assessment of physical markers in studies determining pubertal onset.


1971 ◽  
Vol 25 (3) ◽  
pp. 305-312 ◽  
Author(s):  
W. F. Morris ◽  
E. F. Worden

A spectrographic method has been developed for the determination of 24 trace elements in MoO3. The method is particularly effective for the refractory elements Nb, Ta, Zr, Ti, and V, which are difficult to determine by conventional spectrographic procedures. High sensitivity is achieved in a low amperage arc in argon as a consequence of certain thermochemical reactions which occur in the anode during the arcing process. Although it would appear that the discharge takes place in argon, in fact a small quantity of CO is evolved into the are when MoO3 is reduced in the anode. The evolution of CO changes the composition of the are gas and is essential to the ultimate vaporization and excitation of metal impurities. This paper presents time-resolved spectra, anode temperature, and arc gap voltage measurements which demonstrate the effect of CO.


1997 ◽  
Vol 82 (2) ◽  
pp. 541-549 ◽  
Author(s):  
Kerstin Albertsson-Wikland ◽  
Sten Rosberg ◽  
Birgitta Lannering ◽  
Leo Dunkel ◽  
Gunnar Selstam ◽  
...  

Abstract To follow and correlate gonadotropin and sex steroid changes throughout puberty, 24-h profiles of LH, FSH, testosterone, and estradiol were taken on several occasions for between 2–9.5 yr in 12 healthy boys, aged 8.7–18.2 yr. Serum concentrations of LH and FSH were measured every 20 min, whereas testosterone and estradiol were measured every 2–4 h during the 24-h period. The prepubertal boys (Tanner stage 1) were subdivided into two groups: Pre 1, with a testicular volume of 1–2 mL, and Pre 2, with a testicular volume of 3 mL. Pubertal stages were classified, according to testicular volume, as early puberty (pubertal stage 2; 4–9 mL), midpuberty (pubertal stages 3–4; 10–15 mL), and late puberty (pubertal stage 5; ≥16 mL). Mean levels of LH and FSH increased with pubertal development, although the increase in LH was greater than that in FSH. These increases were due to elevated basal levels of LH and FSH as well as to increases in the number of peaks and the peak amplitudes of LH. No diurnal rhythm was found in boys at stage Pre 1. Thereafter, a clear diurnal rhythm appeared for LH, and later in puberty, an ultradian rhythm was superimposed, as shown by time-sequence analyses. A diurnal rhythm also existed for FSH, but was much less marked than that for LH despite a clear covariation between LH and FSH, as shown from cross-correlation studies. Testosterone also showed diurnal variations from the late prepubertal stage, followed by increasing levels during both day and night in puberty. We conclude that during puberty, gonadotropin levels rise differently for LH and FSH, which may be due to the development of differences in feedback mechanisms. Despite covariation between LH and FSH, only LH showed a clear diurnal variation. In parallel, nocturnal variations in testosterone and estradiol were found. Changes in mean levels of LH, testosterone, and estradiol as well as their mean daytime and nighttime levels follow each other from the prepubertal stages to late puberty.


2019 ◽  
Vol 48 (48) ◽  
pp. 17945-17952 ◽  
Author(s):  
Tian-Yu Liu ◽  
Xiang-Long Qu ◽  
Bing Yan

A novel luminescent probe based on a Eu3+ functionalized MOF hybrid (Eu3+@1) with high sensitivity and selectivity has been proved to possess enormous potential for the determination of fleroxacin in human serum and urine.


2020 ◽  
Vol 105 (8) ◽  
pp. 2846-2856 ◽  
Author(s):  
Susan C Campisi ◽  
Josée D Marchand ◽  
Fahad Javaid Siddiqui ◽  
Muhammad Islam ◽  
Zulfiqar A Bhutta ◽  
...  

Abstract Context Clinicians, researchers, and global health advocates often include pubertal development in outcomes. However, assessments of pubertal stage can be challenging because of the sensitive nature and feasibility of clinical examinations, especially in larger settings. Objective To determine the accuracy of self-assessed Tanner staging when compared with physically assessed Tanner stages by a clinician. Data Sources MEDLINE, PubMed, Embase, Web of Science, Scopus, the Cochrane Library, CINAHL. Study Selection Studies were included if they reported 5 × 5 tables of self-assessment compared to clinician–assessment for the 5-stage Tanner scale. Data Extraction We extracted data to generate complete 5 × 5 tables for each study, including any subgroup eligible for the analysis, such as overweight/obese youth. Data Synthesis After screening, 22 studies representing 21,801 participants met our inclusion criteria for the meta-analysis. Overall agreement was moderate or substantial between the 2 assessments, with breast stage 1, female pubic hair 1, male pubic hair 1, and male pubic hair 5 having the highest agreement. When stages were collapsed into pre- (Tanner stage 1), in (stages 2,3), and completing (stages 4,5) puberty, levels of agreement improved, especially for pre- and completing pubertal development. Most included studies comprised Caucasian youth. More studies are needed which include a broader range of geographic and socioeconomic settings, as well as a greater diversity of racial/ethnic groups. Conclusions Self-assessment of puberty is most accurate when identifying Tanner stage 1, Tanner stage 5 and when development is categorized into prepuberty, in, and completing puberty phases. Use of self-assessment data should be structured accordingly. Protocol Registration PROSPERO # CRD42018100205


2019 ◽  
Vol 85 (2) ◽  
pp. 12-16
Author(s):  
I. V. Saunina ◽  
E. N. Gribanov ◽  
E. R. Oskotskaya

The sorption of Hg (II), Cd (II), and As (III) by natural aluminosilicate is studied. It is shown that the mineral absorbs those toxicants in a rather wide pH range, quantitative extraction of analytes being achieved in a neutral or close to neutral medium (pH values range within 7.0 - 8.0; 6.3 - 7.5; 7.4 - 8.5 for Hg (II), As (III), and Cd (II), respectively). The effect of the time of phase contact on the degree of extraction of elements is shown. The sorption capacity of the mineral in optimal conditions of the medium acidity (0.06 mmol/g for mercury, 0.31 mmol/g for cadmium, and 0.52 mmol/g for arsenic) is determined. The distribution coefficients attain values of aboutnX 103-nX 104. A new combined method for determination of Hg (II), Cd (II), and As (III) in natural and waste water is developed and tested. The method consists in a preliminary group sorption concentration of the analytes by aluminosilicate, desorption of the analytes from the surface of the mineral and their subsequent atomic absorption determination. The correctness of the method is verified in analysis of spiked samples. The method is easy to use and exhibits high sensitivity, reproducibility and accuracy of analyte determination. The relative standard deviation does not exceed 0.13. Economic availability and possibility of using domestic sorption materials are the important advantages of the proposed procedure which can be used in the practice of laboratories monitoring the quality and safety of environmental objects.


2020 ◽  
Vol 23 (10) ◽  
pp. 1010-1022
Author(s):  
Emrah Dural

Aim and scope: Due to the serious toxicological risks and their widespread use, quantitative determination of phthalates in cosmetic products have importance for public health. The aim of this study was to develop a validated simple, rapid and reliable high-performance liquid chromatography (HPLC) method for the determination of phthalates which are; dimethyl phthalate (DMP), diethyl phthalate (DEP), benzyl butyl phthalate (BBP), di-n-butyl phthalate (DBP), di(2- ethylhexyl) phthalate (DEHP), in cosmetic products and to investigate these phthalate (PHT) levels in 48 cosmetic products marketing in Sivas, Turkey. Materials and Methods: Separation was achieved by a reverse-phase ACE-5 C18 column (4.6 x 250 mm, 5.0 μm). As the mobile phase, 5 mM KH2PO4 and acetonitrile were used gradiently at 1.5 ml min-1. All PHT esters were detected at 230 nm and the run time was taking 21 minutes. Results: This method showed the high sensitivity value the limit of quantification (LOQ) values for which are below 0.64 μg mL-1 of all phthalates. Method linearity was ≥0.999 (r2). Accuracy and precision values of all phthalates were calculated between (-6.5) and 6.6 (RE%) and ≤6.2 (RSD%), respectively. Average recovery was between 94.8% and 99.6%. Forty-eight samples used for both babies and adults were successfully analyzed by the developed method. Results have shown that, DMP (340.7 μg mL-1 ±323.7), DEP (1852.1 μg mL-1 ± 2192.0), and DBP (691.3 μg mL-1 ± 1378.5) were used highly in nail polish, fragrance and cream products, respectively. Conclusion: Phthalate esters, which are mostly detected in the content of fragrance, cream and nail polish products and our research in general, are DEP (1852.1 μg mL-1 ± 2192.0), DBP (691.3 μg mL-1 ± 1378.5) and DMP (340.7 μg mL-1 ±323.7), respectively. Phthalates were found in the content of all 48 cosmetic products examined, and the most detected phthalates in general average were DEP (581.7 μg mL-1 + 1405.2) with a rate of 79.2%. The unexpectedly high phthalate content in the examined cosmetic products revealed a great risk of these products on human health. The developed method is a simple, sensitive, reliable and economical alternative for the determination of phthalates in the content of cosmetic products, it can be used to identify phthalate esters in different products after some modifications.


1990 ◽  
Vol 10 (1) ◽  
pp. 89-92 ◽  
Author(s):  
Liliane Larpent ◽  
Christian Verger

The fate of the peritoneal membrane on continuous ambulatory peritoneal dialysis (CAPD) is usually evaluated through the modification of its permeability to various solutes as glucose, creatinine, and urea. Therefore, the accuracy of the methods used for measurements of creatinine is of great importance. A particular problem does exist for creatinine determination as it may be influenced by the presence of glucose. We studied a new enzymatic colorimetric method for creatinine determination in peritoneal dialysis solutions which contain high dextrose concentrations. Creatinine was measured in plasma, urine, and dialysate from 18 patients on CAPD and in pure dextrose solutions, with an enzymatic test (Boehringer Mannheim) and with Jaffe's reaction on two different analyzers: Astra (Beckman) and Eris (Merck). Creatinine results were similar with both assays (Jaffe's reaction and enzymatic test) when measured in blood and urine. However the Jaffe's reaction gave higher creatinine results than the enzymatic test (p < 0.001), when assays were performed in peritoneal dialysis solutions and in pure glucose solutions. In addition, it appeared that other components of dialysis solutions, mainly calcium chloride, influenced unpredictably the results of creatinine with the Jaffe's reaction. We conclude that specific enzymatic test is a more accurate and reliable method to evaluate creatinine kinetics through the peritoneal membrane when determined in CAPD solutions.


Sign in / Sign up

Export Citation Format

Share Document