scholarly journals Serum CA72-4 as a biomarker in the diagnosis of colorectal cancer: A meta-analysis

Open Medicine ◽  
2018 ◽  
Vol 13 (1) ◽  
pp. 164-171 ◽  
Author(s):  
Han Yanqing ◽  
Dong Cheng ◽  
Xu Ling

AbstractThe purpose of this meta-analysis was to investigate the serum CA72-4 as a biomarker in the diagnosis of colorectal cancer by pooling the open published data. Methods. An electronic search of databases Pubmed, Medline, Web of Science, Cochrane Embase CBM, and CNKI were performed by two reviewers (Han Yanqing, Dong Cheng) independently to identify the studies relevant to serum CA72-4 as a biomarker in the diagnosis of colorectal cancer. The patient number of true positive(tp), false positive(fp), false negative(fn) and true negative(tn) were extracted from each included study. The diagnostic performance of serum CA72-4 as a biomarker in the diagnosis of colorectal cancer was assessed by pooled sensitivity, specificity and hierarchical summary receiver operating characteristic curve (HSROC). All the data was pooled by MetaDiSc 1.4 and Stata/SE 11.0 statistical software. Results A total of 22 studies with 2474 colorectal patients and 1576 controls were included in the present study and meta-analysis. The combined diagnostic sensitivity and specificity were 0.50 (95%CI:0.48-0.52) and 0.86 (95%CI:0.84-0.88) for serum CA72-4 as a biomarker in the diagnosis of colorectal cancer. The pooled positive and negative likelihood ratio were 3.41(95%CI:2.57-4.53) and 0.62(0.55-0.71). The pooled area under the ROC curve (AUC) was 0.73. Deeks’funnel plot and Egger’s line regression test (p=0.49) showed no significant publication bias in the present meta-analysis. Conclusion Due toits low diagnostic sensitivity, the diagnostic performance of serum CA72-4 as a biomarker for colorectal cancer screening is limited.

2020 ◽  
Vol 41 (4) ◽  
pp. 240-247
Author(s):  
Lei Yang ◽  
Qingtao Zhao ◽  
Shuyu Wang

Background: Serum periostin has been proposed as a noninvasive biomarker for asthma diagnosis and management. However, its accuracy for the diagnosis of asthma in different populations is not completely clear. Methods: This meta-analysis aimed to evaluate the diagnostic accuracy of periostin level in the clinical determination of asthma. Several medical literature data bases were searched for relevant studies through December 1, 2019. The numbers of patients with true-positive, false-positive, false-negative, and true-negative results for the periostin level were extracted from each individual study. We assessed the risk of bias by using Quality Assessment of Diagnostic Accuracy Studies 2. We used the meta-analysis to produce summary estimates of accuracy. Results: In total, nine studies with 1757 subjects met the inclusion criteria. The pooled estimates of sensitivity, specificity, and diagnostic odds ratios for the detection of asthma were 0.58 (95% confidence interval [CI], 0.38‐0.76), 0.86 (95% CI, 0.74‐0.93), and 8.28 (95% CI, 3.67‐18.68), respectively. The area under the summary receiver operating characteristic curve was 0.82 (95% CI, 0.79‐0.85). And significant publication bias was found in this meta‐analysis (p = 0.39). Conclusion: Serum periostin may be used for the diagnosis of asthma, with moderate diagnostic accuracy.


2019 ◽  
Vol 34 (2) ◽  
pp. 306-314
Author(s):  
Do Hyun Kim ◽  
Youngjun Seo ◽  
Kyung Min Kim ◽  
Seoungmin Lee ◽  
Se Hwan Hwang

Background We evaluated the accuracy of nasal endoscopy in diagnosing chronic rhinosinusitis (CRS) compared with paranasal sinus computed tomography (CT). Methods Two authors independently searched the 5 databases (PubMed, SCOPUS, Embase, the Web of Science, and the Cochrane database) up to March 2019. For all included studies, we calculated correlation coefficients between the endoscopic and CT scores. We extracted data on true-positive and false-positive and true-negative and false-negative results. Methodological quality was assessed using the Quality Assessment of Diagnostic Accuracy Studies tool (version 2). Results We included 16 observational or retrospective studies. A high correlation ( r = .8543; 95% confidence interval [CI] [0.7685–0.9401], P < .0001, I2 = 76.58%) between endoscopy and CT in terms of the diagnostic accuracy for CRS was apparent. The odds ratio (Lund–Kennedy endoscopic score ≥1) was 7.915 (95% CI [4.435–14.124]; I2 = 28.361%). The area under the summary receiver operating characteristic curve was 0.765. The sensitivity and specificity were 0.726 (95% CI [0.584–0.834]) and 0.767 (95% CI [0.685–0.849]), respectively. However, high interstudy heterogeneity was evident given the different endoscopic score thresholds used (Lund–Kennedy endoscopic score ≥1 vs 2). In a subgroup analysis of studies using a Lund–Kennedy endoscopic score threshold ≥2, the area under the summary curve was 0.881, and the sensitivity and specificity were 0.874 (95% CI [0.783–0.930]) and 0.793 (95% CI [0.366–0.962]), respectively. Conclusion Nasal endoscopy is a useful diagnostic tool; the Lund–Kennedy score was comparable with that of CT.


Author(s):  
Minbum Kim ◽  
Do Hyun Kim ◽  
So Yeon Yoon ◽  
Sung Won Kim ◽  
Hansol Hong ◽  
...  

Objectives: This study evaluated the diagnostic value of the various symptoms of COVID-19 in the screening of this disease.Methods: Two authors (working independently) comprehensively reviewed six databases (PubMed, Cochrane database, Embase, Web of Science, SCOPUS, and Google Scholar) from their dates of inception until November 2020. Patient-reported symptoms, including otolaryngologic and general symptoms, were evaluated for their predictive values in adults who underwent testing for COVID-19. True-positive, true-negative, false-positive, and false-negative data were extracted from each study. The methodological quality of included studies was evaluated using the Quality Assessment of Diagnostic Accuracy Studies tool (ver. 2). Results: Twenty-eight prospective and retrospective studies were included in the meta-analysis. The diagnostic odds ratio (DOR) of a change in olfaction and/or taste was 10.20 (95% confidence interval [CI], 8.43; 12.34). The area under the summary receiver operating characteristic curve was 0.8. Olfactory and/or taste changes had a low sensitivity (0.57, 95%CI: 0.47; 0.66) but moderate negative (0.78, 95%CI: 0.69; 0.85] and positive (0.78, 95%CI: 0.66; 0.87) predictive values and a high specificity (0.91, (95%CI: 0.83; 0.96). Olfactory and/or taste changes had a higher diagnostic value than the other otolaryngologic symptoms, a higher DOR and specificity, and a similar or higher diagnostic value than the other general symptoms. Conclusions: Among otolaryngologic symptoms, olfactory and/or taste dysfunction was the most highly associated with COVID-19 and its general symptoms and should be considered when screening for the disease.


2019 ◽  
Vol 61 (7) ◽  
pp. 964-972 ◽  
Author(s):  
Chong Hyun Suh ◽  
Seung Chai Jung ◽  
Se Jin Cho ◽  
Dong-Cheol Woo ◽  
Woo Yong Oh ◽  
...  

Background Hemorrhagic transformation increases mortality and morbidity in patients with acute ischemic stroke. Purpose The purpose of this study is to evaluate the diagnostic performance of magnetic resonance imaging (MRI) for prediction of hemorrhagic transformation in acute ischemic stroke. Material and Methods A systematic literature search of MEDLINE and EMBASE was performed up to 27 July 2018, including the search terms “acute ischemic stroke,” “hemorrhagic transformation,” and “MRI.” Studies evaluating the diagnostic performance of MRI for prediction of hemorrhagic transformation in acute ischemic stroke were included. Diagnostic meta-analysis was conducted with a bivariate random-effects model to calculate the pooled sensitivity and specificity. Subgroup analysis was performed including studies using advanced MRI techniques including perfusion-weighted imaging, diffusion-weighted imaging, and susceptibility-weighted imaging. Results Nine original articles with 665 patients were included. Hemorrhagic transformation is associated with high permeability, hypoperfusion, low apparent diffusion coefficient (ADC), and FLAIR hyperintensity. The pooled sensitivity was 82% (95% confidence interval [CI] 61–93) and the pooled specificity was 79% (95% CI 71–85). The area under the hierarchical summary receiver operating characteristic curve was 0.85 (95% CI 0.82–0.88). Although study heterogeneity was present in both sensitivity (I2=67.96%) and specificity (I2=78.93%), a threshold effect was confirmed. Studies using advanced MRI showed sensitivity of 92% (95% CI 70–98) and specificity of 78% (95% CI 65–87) to conventional MRI. Conclusion MRI may show moderate diagnostic performance for predicting hemorrhage in acute ischemic stroke although the clinical significance of this hemorrhage is somewhat uncertain.


2020 ◽  
Vol 7 ◽  
Author(s):  
Ying Luo ◽  
Ying Xue ◽  
Liyan Mao ◽  
Qun Lin ◽  
Guoxing Tang ◽  
...  

Background: Tuberculous peritonitis (TP) is a common form of abdominal tuberculosis (TB). Diagnosing TP remains challenging in clinical practice. The aim of the present meta-analysis was to evaluate the diagnostic accuracy of peripheral blood (PB) T-SPOT and peritoneal fluid (PF) T-SPOT for diagnosing TP.Methods: PubMed, EmBase, Cochrane, Scopus, Google scholar, China national knowledge internet, and Wan-Fang databases were searched for relevant articles from August 1, 2005 to July 5, 2020. Statistical analysis was performed using Stata, Revman, and Meta-Disc software. Diagnostic parameters including pooled sensitivity, specificity, positive likelihood ratio (PLR), negative likelihood ratio (NLR), and diagnostic odds ratio (DOR) were determined. Summary receiver operating characteristic curve was used to determine the area under the curve (AUC).Results: Twelve studies were eligible and included in the meta-analysis. The analysis showed that the pooled sensitivity and specificity of PB T-SPOT in diagnosing TP were 0.91 (95% CI, 0.88–0.94) and 0.78 (95% CI, 0.73–0.81), respectively, while the pooled PLR, NLR, and DOR were 4.05 (95% CI, 2.73–6.01), 0.13 (95% CI, 0.07–0.23), and 37.8 (95% CI, 15.04–94.98), respectively. On the other hand, the summary estimates of sensitivity, specificity, PLR, NLR, and DOR of PF T-SPOT for TP diagnosis were 0.90 (95% CI, 0.85–0.94), 0.78 (95% CI, 0.72–0.83), 6.35 (95% CI, 2.67–15.07), 0.14 (95% CI, 0.09–0.21), and 58.22 (95% CI, 28.76–117.83), respectively. Furthermore, the AUC of PB T-SPOT and PF T-SPOT for TP diagnosis were 0.91 and 0.94, respectively.Conclusions: Our results indicate that both PB T-SPOT and PF T-SPOT can be served as sensitive approaches for the diagnosis of TP. However, the unsatisfactory specificities of these two methods limit their application as rule-in tests for TP diagnosis. Furthermore, the standardization of the operating procedure of PF T-SPOT is further needed.


2015 ◽  
Vol 2015 ◽  
pp. 1-7 ◽  
Author(s):  
Daye Cheng ◽  
Ying Sun ◽  
Hu He

The diagnostic value of serum HE4 in patients with lung cancer remains controversial. Thus, we performed a systematic review and meta-analysis to assess the diagnostic accuracy of serum HE4 for lung cancer. We conducted a comprehensive literature search in PubMed, EMBASE, Chinese National Knowledge Infrastructure (CNKI), and WANFANG databases between Jan. 1966 and Nov. 2014. The diagnostic sensitivity (SEN), specificity (SPE), positive likelihood ratio (PLR), negative likelihood ratio (NLR), diagnostic odds ratio (DOR), and summary receiver operating characteristic curve (SROC) were pooled by Meta-DiSc 1.4 software. A total of seven articles including 715 cases and 549 controls were included for analysis. The summary estimates for serum HE4 in the diagnosis of lung cancer in these studies were pooled SEN 0.72 (95% CI: 0.68–0.75), SPE 0.85 (95% CI: 0.81–0.88), PLR 4.68 (95% CI: 3.23–6.78), NLR 0.31 (95% CI: 0.24–0.39), and DOR 17.14 (95% CI: 9.72–30.20), and the area under the curve (AUC) was 0.8557. This meta-analysis indicated that serum HE4 is a potential tool in the diagnosis of lung cancer. In addition, considering the high heterogeneity and potential publication bias, further studies with rigorous design and large sample size are needed in the future.


Cancers ◽  
2021 ◽  
Vol 13 (21) ◽  
pp. 5253
Author(s):  
Md. Mohaimenul Islam ◽  
Tahmina Nasrin Poly ◽  
Bruno Andreas Walther ◽  
Ming-Chin Lin ◽  
Yu-Chuan (Jack) Li

Gastric cancer (GC) is one of the most newly diagnosed cancers and the fifth leading cause of death globally. Identification of early gastric cancer (EGC) can ensure quick treatment and reduce significant mortality. Therefore, we aimed to conduct a systematic review with a meta-analysis of current literature to evaluate the performance of the CNN model in detecting EGC. We conducted a systematic search in the online databases (e.g., PubMed, Embase, and Web of Science) for all relevant original studies on the subject of CNN in EGC published between January 1, 2010, and March 26, 2021. The Quality Assessment of Diagnostic Accuracy Studies-2 was used to assess the risk of bias. Pooled sensitivity, specificity, positive likelihood ratio, negative likelihood ratio, and diagnostic odds ratio were calculated. Moreover, a summary receiver operating characteristic curve (SROC) was plotted. Of the 171 studies retrieved, 15 studies met inclusion criteria. The application of the CNN model in the diagnosis of EGC achieved a SROC of 0.95, with corresponding sensitivity of 0.89 (0.88–0.89), and specificity of 0.89 (0.89–0.90). Pooled sensitivity and specificity for experts endoscopists were 0.77 (0.76–0.78), and 0.92 (0.91–0.93), respectively. However, the overall SROC for the CNN model and expert endoscopists was 0.95 and 0.90. The findings of this comprehensive study show that CNN model exhibited comparable performance to endoscopists in the diagnosis of EGC using digital endoscopy images. Given its scalability, the CNN model could enhance the performance of endoscopists to correctly stratify EGC patients and reduce work load.


2020 ◽  
Author(s):  
Yao Lin ◽  
Jiabing Rong ◽  
Zhaocai Zhang

Abstract BackgroundSepsis is a life-threatening and time-critical medical emergency; therefore, the early diagnosis of sepsis is essential to timely treatment and favorable outcomes for patients susceptible to sepsis. Eosinopenia has been identified as a potential biomarker of sepsis in the past decade. However, its clinical application progress is slow and its recognition is low. Recent studies have again focused on the potential association between Eosinopenia and severe infections. This study analyzed the efficacy of Eosinopenia as a biomarker for diagnosis of sepsis and its correlation with pathophysiology of sepsis.MethodWe searched PubMed, EMBASE, Web of Science, and Cochrane Central Register of Controlled Trials CENTRAL databases to identify studies that met the inclusion criteria. Two authors performed data extraction independently. The pooled outcomes were calculated by TP (true positive), FP (false positive), FN (false negative), TN (true negative) by using bivariate meta-analysis model in STATA 14.0 software. Meanwhile, possible mechanisms of sepsis induced Eosinopenia was also analyzed.ResultsSeven studies were included in the present study with a total number of 3842 subjects. The incidence of Eosinopenia based on the enrolled studies varied from 23.2% to 92.7%. For diagnosis of sepsis, the pooled sensitivity, specificity, positive likelihood ratio, negative likelihood ratio and diagnostic odds ratio of Eosinopenia were 0.66 (95%CI [0.53-0.77]), 0.68 (95%CI [0.56-0.79]), 2.09 (95%CI [1.44-3.02]), 0.49 (95%CI [0.34-0.71]) and 4.23 (95%CI [2.15-8.31]), respectively. The area under the summary receiver operator characteristic curve (SROC) was 0.73 (95%CI [0.68-0.76]). Meta-regression analysis revealed that no single parameter accounted for the heterogeneity of pooled outcomes. For each subgroup of different eosinopenia cutoff values (50, 40, ≤25, 100), the sensitivity was 0.61, 0.79, 0.57, 0.54, and the specificity was 0.61, 0.75, 0.83, 0.51, respectively. ConclusionsOur findings suggested that Eosinopenia has a high incidence in sepsis but has no superiority in comparison with conventional biomarkers for diagnosis of sepsis. However, eosinopenia can still be used in clinical diagnosis for sepsis as a simple, convenient, fast and inexpensive biomarker. Therefore, further large clinical trials are still needed to re-evaluate eosinopenia as a biomarker of sepsis.


PLoS ONE ◽  
2021 ◽  
Vol 16 (3) ◽  
pp. e0248827
Author(s):  
Lili He ◽  
Yinghua Sun ◽  
Wei Sheng ◽  
Qiong Yao

Several recent studies demonstrated that lung ultrasound could achieve desired diagnostic accuracy for transient tachypnea of the neonate (TTN). However, the diagnostic performance of lung ultrasound for TTN has not been systematically studied to date. This meta-analysis aimed to investigate the performance of lung ultrasound in diagnosing TTN. The relevant literature was searched in PubMed, Medline, the Cochrane Library, and Embase databases without any restriction in terms of language and time until January 31, 2021. Studies that assessed the diagnostic performance of lung ultrasound for TTN were included. Seven studies with 1514 participants were summarized. The lung ultrasound provided more accurate performance for diagnosing TTN with pooled sensitivity and specificity of 0.67 [95% confidence interval (CI) = 0.63–0.71] and 0.97 (95% CI = 0.95–0.98), respectively. A higher summarized area under the summary receiver operating characteristic curve was observed as 0.9906. Lower sensitivity and area under the curve (AUC) of B-lines for TTN were observed as 0.330 (95% CI = 0.27–0.38) and 0.5000, respectively. Lung ultrasound provided highly accurate AUC, sensitivity, and specificity in detecting TTN. Large-scale studies are warranted in the future to confirm these results.


2018 ◽  
Vol 26 (2) ◽  
pp. 111-117 ◽  
Author(s):  
Libing Jiang ◽  
Jing Wu ◽  
Xia Feng

Background: Hollow organs perforation is a life-threatening condition. Early diagnosis and emergent intervention are important. Bedside ultrasound may be an alternative diagnostic tool for this condition. Objective: The aim of this study was to explore the diagnostic value of ultrasound of pneumoperitoneum in emergent or critical conditions through meta-analysis. Methods: PubMed, EMBASE, and Cochrane Library were systematically searched for potential studies. Then, two reviewers performed the processes of study selection, data extraction, and quality assessment independently. Finally, diagnostic indexes were analyzed with STATA 12.0 software (Serial No. 40120519635). Results: A total of five studies with moderate to high quality were eligible for meta-analysis. The pooled sensitivity, specificity, positive likelihood ratio, and negative likelihood ratio and their 95% confidence interval were 0.91 (95% confidence interval = 0.86–0.94), 0.96 (95% confidence interval = 0.75–0.99), 22.05 (95% confidence interval = 3.10–156.96), and 0.10 (95% confidence interval = 0.07–0.15), respectively. The area under the summary receiver operating characteristic curve was 0.92 (95% confidence interval = 0.90–0.94). Conclusion: Abdominal ultrasound is a useful alternative tool in diagnosing of pneumoperitoneum. However, due to limited evidence, it is not yet indicated for routine clinical use.


Sign in / Sign up

Export Citation Format

Share Document