scholarly journals Actual trends in the use of the kastle-meyer test: applications in different species and verification of the limit of detection of sensitivity and vestigiality

Author(s):  
Andre Rinaldi Fukushima ◽  
Renata Inzinna Bernardo Fonseca ◽  
Esther Lopes Ricci ◽  
Helenice de Souza Spinosa ◽  
Maria Marta Bernardi ◽  
...  
Keyword(s):  
1973 ◽  
Vol 72 (4) ◽  
pp. 714-726 ◽  
Author(s):  
A. Burger ◽  
B. Miller ◽  
C. Sakoloff ◽  
M. B. Vallotton

ABSTRACT An improved method for the determination of serum triiodothyronine (T3) has been developed. After addition of a tracer amount of the hormone, T3 was extracted from 1 ml serum under conditions of pH and ionic strength which favoured T3 extraction (89%) over thyroxine (T4) extraction (58%). Chromatography of the extracted material on Sephadex LH-20 separated T3 completely from residual T4. The T3 eluate was dried, then re-dissolved in 0.5 ml NaOH 0.04 n. To 0.2 ml duplicate aliquots, a standard amount of TBG was added for the competitive protein analysis. After one hour incubation at 4°C, separation of bound from free T3 was achieved on small Sephadex G-25 columns. Overall recovery was 67 ± 10.8% and correction for the loss was made. The solvent blank was 37 ± 27 (sd) ng/100 ml. Accuracy of measurement of known quantities of T3 added to serum was 98.4%. The coefficient of variation within the assay was 6.2% and between the assays it was 11.4%. The limit of detection (0.1 ng) corresponded to a concentration of 25 ng/100 ml. T4 added to serum did not interfere with T3 determination until high non-physiological values were reached. The mean ± sd serum T3 in 54 euthyroid subjects was 153 ± 58 ng/100 ml and in 24 hyperthyroid patients it was 428 ±186 ng/100 ml; 4 out of the 24 hyperthyroid values were within 2 sd of the mean euthyroid group. All the values found in the euthyroid group were well above the limit of detection of the method.


2017 ◽  
Vol 26 (2) ◽  
pp. 171-181 ◽  
Author(s):  
Liana Gheorghe ◽  
Ioan Sporea ◽  
Speranţa Iacob ◽  
Roxana Şirli ◽  
Anca Trifan ◽  
...  

Background & Aims: Hepatitis C Virus (HCV) infection is a common condition with endemic prevalence in some areas of the world. In Romania, the mean prevalence is about 3%. New treatments became available on the market in recent years and new drugs are in the pipeline. A re-evaluation of HCV therapy was considered mandatory. The Romanian Society of Gastroenterology and Hepatology undertook this task for the practitioners of this country.Methodology: A group of recognized experts was created who screened the available literature and the major available guidelines. A list of items requiring attention has been created. These items were discussed and rated. Decisions were taken by consensus.Recommendations: We present here the first of the two parts of our Society’s recommendations for chronic HCV infection treatment. An agreement was reached regarding the diagnostic tools, the assessment of severity and the up-dated therapy schedules.Conclusions: This Position Paper represents a guide for the assessment and the therapy of HCV infection. The recommendations are in concordance with other guidelines but are applied to the real-life conditions in this country.Abbreviations: DAAs: Direct-acting antivirals; DDIs: Drug-drug interactions; ESLD: End-stage liver disease; ESRD: End-stage renal disease; eGFR: Estimated glomerular filtration rate; EASL: European Association for the Study of the Liver; EMA: European Medicines Agency; FDA: US Food and Drug Administration; FDC: Fixed-dose combination; GT: Genotype; GRADE: Grading of Recommendations Assessment, Development and Evaluation; HCV: Hepatitis C virus; HCC: Hepatocellular carcinoma; LT: Liver transplantation; LLD: Lower limit of detection; MELD score: Mayo-Clinic End-Stage Liver Disease score; ANMDM: National Agency of Medicines and Medical Devices; PPIs: Proton pump inhibitors; PWID: People who inject drugs; RCT: Randomized controlled trial; RDT: Rapid diagnostic test; RAS: Resistance-associated substitution; SRGH: Romanian Society of Gastroenterology and Hepatology; SAE: serious adverse events; SPC: Summary of Product Characteristics; SVR: Sustained virologic response.


Author(s):  
Raju Chandra ◽  
Manisha Pant ◽  
Harchan Singh ◽  
Deepak Kumar ◽  
Ashwani Sanghi

A reliable and reproducible reversed-phase high performance liquid chromatography (RP-HPLC) was developed for the quantitative determination of Remipril drug content from marketed bulk tablets. The active ingredient of Remipril separation achieved with C18 column using the methanol water mobile phase in the ratio of 40:60 (v/v). The active ingredient of the drug content quantify with UV detector at 215 nm. The retention time of Remipril is 5.63 min. A good linearity relation (R2=0.999) was obtained between drug concentration and average peak areas. The limit of detection and limit of quantification of the instrument were calculated 0.03 and 0.09 µg/mL, respectively. The accuracy of the method validation was determined 102.72% by recoveries method.


Author(s):  
Mohammad Hamzah Hamzah ◽  
Rawa M M Taqi ◽  
Muna M. Hasan ◽  
Raid J. M. Al-Timimi

A simple and accurate spectrophotometric method for the determination of Trifluoperazine HCl in pure and dosage forms was developed. The method is based on the reaction between Trifluoperazine HCl and p-chloroaniline in the presence of cerium ion as oxidizing agent which lead to the formation of violate color product that absorbed at a maximum wavelength 570nm while the blank solution was pink. Under the optimum conditions a linear relationship between the intensity and concentration of TRF in the range 4-50μg/ml was obtained . The molar absorptivity 3.74×103 L.mol-1.cm-1 , Limit of detection (2.21μg/ml), while limit of quantification was 7.39μg/ml. The proposed analytical method was compared with standard method using t-test and F-test , the obtained results shows there is no significant differences between proposed method and standard method. Based on that the proposed method can be used as an alternative method for the determination of TRF in pure and dosage forms.


2017 ◽  
Author(s):  
Bo Tian ◽  
Peter Svedlindh ◽  
Mattias Strömberg ◽  
Erik Wetterskog

In this work, we demonstrate for the first time, a ferromagnetic resonance (FMR) based homogeneous and volumetric biosensor for magnetic label detection. Two different isothermal amplification methods, <i>i.e.</i>, rolling circle amplification (RCA) and loop-mediated isothermal amplification (LAMP) are adopted and combined with a standard electron paramagnetic resonance (EPR) spectrometer for FMR biosensing. For RCA-based FMR biosensor, binding of RCA products of a synthetic Vibrio cholerae target DNA sequence gives rise to the formation of aggregates of magnetic nanoparticles. Immobilization of nanoparticles within the aggregates leads to a decrease of the net anisotropy of the system and a concomitant increase of the resonance field. A limit of detection of 1 pM is obtained with an average coefficient of variation of 0.16%, which is superior to the performance of other reported RCA-based magnetic biosensors. For LAMP-based sensing, a synthetic Zika virus target oligonucleotide is amplified and detected in 20% serum samples. Immobilization of magnetic nanoparticles is induced by their co-precipitation with Mg<sub>2</sub>P<sub>2</sub>O<sub>7</sub> (a by-product of LAMP) and provides a detection sensitivity of 100 aM. The fast measurement, high sensitivity and miniaturization potential of the proposed FMR biosensing technology makes it a promising candidate for designing future point-of-care devices.<br>


Author(s):  
V. N. Rakitskii ◽  
N. E. Fedorova ◽  
I. V. Bereznyak ◽  
N. G. Zavolokina ◽  
L. P. Muhina

The article presents results of studies exemplified by diquat on analysis concerning influence of lower limit value of quantitative assessment in washing sample for safety coefficient in exposure and in absorbed dose, if acting substance is absent in workplace ambient air samples and in dermal washings of workers. To control diquat in dermal washings, there is a method based on ion-pair liquid chromatography with ultraviolet detection (working wavelength 310 nm). To concentrate sample, cartridges for solid-phase extraction, containing ion exchange sorbent (Oasis MCX 6cc/500 mg), are used. Lower limit of assessment in washing sample — 0,15 micrograms. Experimentally set washing completeness is within range of 80–92%, standard deviation of repetition is 7,0% at most. The method created was tested in nature studies determining dermal exposure in workers subjected to 5 various preparations based on diquat dibromide when used for surface spraying from tractor and from aircraft. For lower limit of detection in washing sample (0,15 micrograms/washing), calculated risk value of exposure varied within 0,26–0,36; risk of absorbed dose was low — 0,23 (the allowable one ≤1). Findings are that present measuring methods which provide lower limit of detection 1 and 5 micrograms in washing sample could result in unallowable risk establishment even with absence of the substance in all samples of workplace air and dermal washings. The calculation formula suggested enables to give theoretic basis for requirements to lower limit of detecting active substances in dermal washing samples for evaluating risk of pesticides use in agriculture.


Author(s):  
Carla Eiras

Interleukin-6 (IL-6) is a multifunctional cytokine and high bloodstream levels of which have been associated with severe inflammatory diseases, such as dengue fever, sepsis, various cancers, and visceral leishmaniasis (VL). Rapid tests for the quantification of IL-6 would be of great assistance for the bedside diagnosis and treatment of diseases such as VL. We have developed a lateral flow assay (LFA) for rapid and colorimetric IL-6 detection, consisting of anti-IL-6 antibodies conjugated to gold nanoparticles (AuNPs). The optimal concentration of anti-IL-6 used in the conjugate was determined to be 800.0 μg/mL, based on an aggregation assay using LFA. A linear relationship between IL-6 standard concentration and color intensity was observed after 20 min, with a linear range between 1.25 ng/mL and 9,000 ng/mL. The limit of detection for this method was estimated a t0.38 ng/mL. The concentration of IL-6 in five patients with severe VL was measured using LFA, and the results were consistent with those obtained using the cytometric bead array (CBA) method. A thorough analysis of the LFA membranes’ surface morphology, before and after sample contact, was performed using atomic force microscopy (AFM).The prototype described here is still being tested and improved, but this LFA will undoubtedly be of great help in the clinical quantification of IL-6.


Author(s):  
Carla Eiras

Interleukin-6 (IL-6) is a multifunctional cytokine and high bloodstream levels of which have been associated with severe inflammatory diseases, such as dengue fever, sepsis, various cancers, and visceral leishmaniasis (VL). Rapid tests for the quantification of IL-6 would be of great assistance for the bedside diagnosis and treatment of diseases such as VL. We have developed a lateral flow assay (LFA) for rapid and colorimetric IL-6 detection, consisting of anti-IL-6 antibodies conjugated to gold nanoparticles (AuNPs). The optimal concentration of anti-IL-6 used in the conjugate was determined to be 800.0 μg/mL, based on an aggregation assay using LFA. A linear relationship between IL-6 standard concentration and color intensity was observed after 20 min, with a linear range between 1.25 ng/mL and 9,000 ng/mL. The limit of detection for this method was estimated at a t0.38 ng/mL. The concentration of IL-6 in five patients with severe VL was measured using LFA, and the results were consistent with those obtained using the cytometric bead array (CBA) method. A thorough analysis of the LFA membranes’ surface morphology, before and after sample contact, was performed using atomic force microscopy (AFM). The prototype described here is still being tested and improved, but this LFA will undoubtedly be of great help in the clinical quantification of IL-6.


2017 ◽  
Vol 68 (4) ◽  
pp. 666-670 ◽  
Author(s):  
Mirela Mihon ◽  
Catalin Stelian Tuta ◽  
Alina Catrinel Ion ◽  
Dana Niculae ◽  
Vasile Lavric

The aim of this work was the development and validation of a fast analytical method to determine the residual solvents content in radiopharmaceuticals such as: 18F-Fluorodeoxyglucose (18F-FDG), 18F-Fluoroestradiol (18F-FES), 18F-Fluorothymidine (18F-FLT),18F-Fluoromisonidazole (18F-FMISO). Radiopharmaceuticals are radioactive preparations for medical purposes used in nuclear medicine as tracers in diagnostic imaging and treatment of certain diseases. Positron Emission Tomography (PET) is a medical imaging technique that consists in introducing into the body of a small amount of a biologically active chemical compound labelled with a short lived positron-emitting radioisotope (18F, 11C, 68Ga). Residual solvents are critical impurities in radiopharmaceuticals that can affect labelling, stability and physicochemical properties of drugs. Therefore, the determination of these solvents is essential for quality control of radiopharmaceuticals. Validation of the control method for residual solvents by gas chromatography is referred by the European Pharmacopoeia using a special injection technique (head space). The parameters of the method, which comply with International Conference on Harmonization guidelines, are: accuracy, precision, linearity, limit of detection, limit of quantification and robustness. The proposed method (direct gas chromatography injection) proved to be linear, precise, accurate and robust. Good linearity was achieved for all the solvents and correlation coefficients (R2) for each residual solvent were found more than 0.99.


1991 ◽  
Vol 24 (2) ◽  
pp. 267-272 ◽  
Author(s):  
S. Dubrou ◽  
H. Kopecka ◽  
J. M. Lopez Pila ◽  
J. Maréchal ◽  
J. Prévot

Enteroviruses were specifically detected by dot blot hybridization when using poliovirus type 1 (PV1) derived subgenomic radiolabeled cRNA probes (riboprobes) in environmental water specimens and in the cell cultures in which the viruses were amplificated. The riboprobe corresponding to the 5' noncoding sequence detected the majority of enteroviruses. Hepatitis A virus (HAV) was specifically detected by an HAV cRNA probe corresponding to the 5' noncoding region of its genome. By this test, the limit of detection of coxsackievirus B5 and echovirus 7 seeded in mineral water was 103 to 104 PFU/spot. In cell cultures, positive signals were observed in the lysates of cells infected by one PFU. Higher positive signals were obtained with a short PV1 probe (nt 221-670) corresponding to the 5' noncoding region, which is a well preserved sequence among the enteroviruses, than with PV1 genomic probe. Hybridization allowed a good detection of enteroviral RNAs in wastewater specimens, but with a lower efficiency in surface water. In this case, amplification of viruses in the cell cultures gave significant hybridization results.


Sign in / Sign up

Export Citation Format

Share Document