scholarly journals CORRECTION OF THE QUALITY OF CURRENT OF THE ELECTRIC NETWORK WITH A THYRISTOR REGULATOR OF AC VOLTAGE WITH ACTIVE-INDUCTIVE LOAD

Author(s):  
A.I. Chyzhenko ◽  
◽  
I.V. Blinov ◽  

The use of the AC voltage control method is considered. In this method, the improvement of the current quality of the supply network is achieved by a discrete change of the inductance in the network current flow circuit. In this method, it is proposed to use a circuit with counter-parallel thyristors and the neutral wire. The dependences of the harmonic coefficient and the current distortion coefficient of the electric network on the values of the regulated voltage are constructed. The obtained dependences prove the effectiveness of the proposed regulator. The required number of reactor sections is determined and the proper inductance of their windings to provide the values ​​of the harmonics coefficient that does not exceed 7% while adjusting the voltage depth of 50% on the active-inductive load. References 9, 3 figures 3, table.

1997 ◽  
Vol 77 (5) ◽  
pp. 2300-2315 ◽  
Author(s):  
Andrey Vyshedskiy ◽  
Jen-Wei Lin

Vyshedskiy, Andrey and Jen-Wei Lin. Activation and detection of facilitation as studied by presynaptic voltage control at the inhibitor of the crayfish opener muscle. J. Neurophysiol. 77: 2300–2315, 1997. Facilitation at the crayfish neuromuscular inhibitor synapse was investigated with the use of a presynaptic voltage control method in which 5-ms presynaptic pulses were used to activate and monitor facilitation. A single 5-ms pulse was able to activate facilitation with a decay time constant similar to that of the F2 component of facilitation activated by action potentials. The quality of the control of presynaptic potential during F2 facilitation was evaluated by measuring the amplitude of presynaptic pulses and by analyzing the shape of the depolarization-release coupling plot during facilitation. Both approaches suggested that neither the amplitude of presynaptic depolarizations nor the space clamp of the presynaptic axon was changed during F2 facilitation. The activation of facilitation was examined by changing the amplitude of conditioning pulses systematically and using a test pulse of a constant amplitude to monitor facilitation. We found that a significant amount of facilitation could be activated by conditioning pulses that were subthreshold to the activation of transmitter release. Facilitation plateaued before the inhibitory postsynaptic potentials (IPSPs) activated by conditioning pulses reached their maximum. A double logarithm plot of facilitation magnitude against the conditioning IPSP amplitude yielded a slope of 0.34, which implies that the calcium ion cooperativity of activating facilitation is about one third of the secretion process. These findings enabled us to activate near maximal facilitation, by a burst of subthreshold conditioning pulses, without any conditioning transmitter release, and, therefore, to avoid complications associated with previous transmitter release. The detection of facilitation was examined by changing test pulse amplitude systematically to evaluate the ability of the test pulse to detect a constant level of facilitation. The magnitude of normalized facilitation decreased with increasing test pulse amplitude. The magnitude of absolute facilitation (the amplitude of the facilitated minus the control IPSP) increased with increasing test pulse amplitude. A double logarithm plot between facilitated and control IPSPs gave rise to a slope of 0.77, which suggests that the calcium cooperativity of transmitter release was decreased during facilitation.


2020 ◽  
Vol 140 (6) ◽  
pp. 456-464
Author(s):  
Naoto Yorino ◽  
Tsubasa Watakabe ◽  
Ahmed Bedawy Khalifa ◽  
Yutaka Sasaki ◽  
Yoshifumi Zoka

2012 ◽  
Vol 132 (4) ◽  
pp. 309-316 ◽  
Author(s):  
Shoji Kawasaki ◽  
Noriaki Kanemoto ◽  
Hisao Taoka ◽  
Junya Matsuki ◽  
Yasuhiro Hayashi

2011 ◽  
Vol 131 (11) ◽  
pp. 896-904
Author(s):  
Yuji Tamura ◽  
Shinji Takasaki ◽  
Yasuyuki Miyazaki ◽  
Hideo Takeda ◽  
Shoichi Irokawa ◽  
...  

2020 ◽  
Vol 3 (3) ◽  
pp. 95-99
Author(s):  
E. H. ABU ◽  

The article explores individual approaches used to measure and evaluate the quality of financial state-ments: standardized assessment, accrual-based models (accrual quality), Beneise models (M-Score), in-dexes - the internal control method and the degree of accounting conservatism. The reason for the great dependence on the use of indirect measures (proxies for the quality of financial statements or stock prices) is that some of the qualities of financial statements are unobservable.


2017 ◽  
Vol 6 (04) ◽  
pp. 5347 ◽  
Author(s):  
Omar B. Ahmed* ◽  
Anas S. Dablool

Several methods of Deoxyribonucleic acid (DNA) extraction have been applied to extract bacterial DNA. The amount and the quality of the DNA obtained for each one of those methods are variable. The study aimed to evaluate bacterial DNA extraction using conventional boiling method followed by alcohol precipitation. DNA extraction from Gram negative bacilli was extracted and precipitated using boiling method with further precipitation by ethanol. The extraction procedure performed using the boiling method resulted in high DNA yields for both E. coli and K. pneumoniae bacteria in (199.7 and 285.7μg/ml, respectively) which was close to control method (229.3 and 440.3μg/ml). It was concluded that after alcohol precipitation boiling procedure was easy, cost-effective, and applicable for high-yield quality of DNA in Gram-negative bacteria.


2015 ◽  
Vol 713-715 ◽  
pp. 1556-1559
Author(s):  
Ning Wang ◽  
De Chao Zhang

The inductance and the capacitance on DC side are two important parameter of SVG. In this paper, the effect of inductance and capacitance on DC sides’ voltage control method of SVG is addressed.


2013 ◽  
Vol 732-733 ◽  
pp. 1261-1264
Author(s):  
Zhi Lei Yao ◽  
Lan Xiao ◽  
Jing Xu

An improved control strategy for three-phase grid-connected inverters with space vector pulse width modulation (SVPWM) is proposed. When the grid current contains harmonics, the d-and q-axes grid currents is interacted in the traditional control method, and the waveform quality of the grid current is poor. As the reference output voltage cannot directly reflect the change of the reference grid current with the traditional control strategy, the dynamic response of the grid-connected inverter is slow. In order to solve the aforementioned problems, the d-and q-axes grid currents in the decoupled components of the grid current controller are substituted by the d-and q-axes reference grid currents, respectively. The operating principles of the traditional and proposed control methods are illustrated. Experimental results show that the grid-connected inverter with the improved control strategy has high waveform quality of the grid current and fast dynamic response.