Precessional strategies for the ultrafast switching of soft and hard magnetic nanostructures

2002 ◽  
Vol 746 ◽  
Author(s):  
T. Devolder ◽  
M. Belmeguenai ◽  
H. W. Schumacher ◽  
C. Chappert ◽  
Y. Suzuki

ABSTRACTWe discuss the precessional, quasi-ballistic switching of magnetization in magnetic nanostructures. In soft spin-valve cells, fast and energy-cost effective magnetization switching can be triggered by a transverse field pulse of moderate amplitude, below the in plane anisotropy field, because of an amplification effect brought by the demagnetizing field at the early stage of the reversal. The same effect is no more possible in hard nanomagnets with perpendicular easy magnetization axis. We propose a new type of nanostructured magnetic device, designed to overcome this limitation. The speed is obtained through the use of a very high effective magnetic field, obtained by incorporating a significant exchange field which stores the energy in the form of a constrained domain wall surrounding a region of high magnetic anisotropy. This stored energy is partially available to accelerate the magnetization reversal in a precessional scenario. We illustrate the concept by studying numerically a model system. The key parameter for the reversal is the ratio of the domain wall width to the structure lateral dimension. Possible routes for device preparation are discussed. Promising application to magnetic storage are anticipated.

2003 ◽  
Vol 777 ◽  
Author(s):  
T. Devolder ◽  
M. Belmeguenai ◽  
C. Chappert ◽  
H. Bernas ◽  
Y. Suzuki

AbstractGlobal Helium ion irradiation can tune the magnetic properties of thin films, notably their magneto-crystalline anisotropy. Helium ion irradiation through nanofabricated masks can been used to produce sub-micron planar magnetic nanostructures of various types. Among these, perpendicularly magnetized dots in a matrix of weaker magnetic anisotropy are of special interest because their quasi-static magnetization reversal is nucleation-free and proceeds by a very specific domain wall injection from the magnetically “soft” matrix, which acts as a domain wall reservoir for the “hard” dot. This guarantees a remarkably weak coercivity dispersion. This new type of irradiation-fabricated magnetic device can also be designed to achieve high magnetic switching speeds, typically below 100 ps at a moderate applied field cost. The speed is obtained through the use of a very high effective magnetic field, and high resulting precession frequencies. During magnetization reversal, the effective field incorporates a significant exchange field, storing energy in the form of a domain wall surrounding a high magnetic anisotropy nanostructure's region of interest. The exchange field accelerates the reversal and lowers the cost in reversal field. Promising applications to magnetic storage are anticipated.


Author(s):  
Muhammad Nadeem Ashraf ◽  
Muhammad Hussain ◽  
Zulfiqar Habib

Diabetic Retinopathy (DR) is a major cause of blindness in diabetic patients. The increasing population of diabetic patients and difficulty to diagnose it at an early stage are limiting the screening capabilities of manual diagnosis by ophthalmologists. Color fundus images are widely used to detect DR lesions due to their comfortable, cost-effective and non-invasive acquisition procedure. Computer Aided Diagnosis (CAD) of DR based on these images can assist ophthalmologists and help in saving many sight years of diabetic patients. In a CAD system, preprocessing is a crucial phase, which significantly affects its performance. Commonly used preprocessing operations are the enhancement of poor contrast, balancing the illumination imbalance due to the spherical shape of a retina, noise reduction, image resizing to support multi-resolution, color normalization, extraction of a field of view (FOV), etc. Also, the presence of blood vessels and optic discs makes the lesion detection more challenging because these two artifacts exhibit specific attributes, which are similar to those of DR lesions. Preprocessing operations can be broadly divided into three categories: 1) fixing the native defects, 2) segmentation of blood vessels, and 3) localization and segmentation of optic discs. This paper presents a review of the state-of-the-art preprocessing techniques related to three categories of operations, highlighting their significant aspects and limitations. The survey is concluded with the most effective preprocessing methods, which have been shown to improve the accuracy and efficiency of the CAD systems.


2021 ◽  
Vol 21 (1) ◽  
Author(s):  
Mitnala Sasikala ◽  
Yelamanchili Sadhana ◽  
Ketavarapu Vijayasarathy ◽  
Anand Gupta ◽  
Sarala Kumari Daram ◽  
...  

Abstract Background A considerable amount of evidence demonstrates the potential of saliva in the diagnosis of COVID-19. Our aim was to determine the sensitivity of saliva versus swabs collected by healthcare workers (HCWs) and patients themselves to assess whether saliva detection can be offered as a cost-effective, risk-free method of SARS-CoV-2 detection. Methods This study was conducted in a hospital involving outpatients and hospitalized patients. A total of 3018 outpatients were tested. Of these, 200 qRT-PCR-confirmed SARS-CoV-2-positive patients were recruited for further study. In addition, 101 SARS-CoV-2-positive hospitalized patients with symptoms were also enrolled in the study. From outpatients, HCWs collected nasopharyngeal swabs (NPS), saliva were obtained. From inpatients, HCWs collected swabs, patient-collected swabs, and saliva were obtained. qRT-PCR was performed to detect SARS-CoV-2 by TAQPATH assay to determine the sensitivity of saliva detection. Sensitivity, specificity and positive/negative predictive values (PPV, NPV) of detecting SARS-CoV-2 were calculated using MedCalc. Results Of 3018 outpatients (asymptomatic: 2683, symptomatic: 335) tested by qRT-PCR, 200 were positive (males: 140, females: 60; aged 37.9 ± 12.8 years; (81 asymptomatic, 119 symptomatic). Of these, saliva was positive in 128 (64%); 39 of 81 asymptomatic (47%),89 of 119 symptomatic patients (74.8%). Sensitivity of detection was 60.9% (55.4–66.3%, CI 95%), with a negative predictive value of 36%(32.9–39.2%, CI 95%).Among 101 hospitalized patients (males:65, females: 36; aged 53.48 ± 15.6 years), with HCW collected NPS as comparator, sensitivity of saliva was 56.1% (47.5–64.5, CI 95%), specificity 63.5%(50.4–75.3, CI95%) with PPV of 77.2% and NPV of 39.6% and that of self-swab was 52.3%(44–60.5%, CI95%), specificity 56.6% (42.3–70.2%, CI95%) with PPV 77.2% and NPV29.7%. Comparison of positivity with the onset of symptoms revealed highest detection in saliva on day 3 after onset of symptoms. Additionally, only saliva was positive in 13 (12.8%) hospitalized patients. Conclusion Saliva which is easier to collect than nasopharyngeal swab is a viable alternate to detect SARS-COV-2 in symptomatic patients in the early stage of onset of symptoms. Although saliva is currently not recommended for screening asymptomatic patients, optimization of collection and uniform timing of sampling might improve the sensitivity enabling its use as a screening tool at community level.


2004 ◽  
Vol 95 (11) ◽  
pp. 6777-6779 ◽  
Author(s):  
J. Grollier ◽  
P. Boulenc ◽  
V. Cros ◽  
A. Hamzić ◽  
A. Vaurès ◽  
...  

2015 ◽  
Vol 233-234 ◽  
pp. 55-59
Author(s):  
Marina Kirman ◽  
Artem Talantsev ◽  
Roman Morgunov

The magnetization dynamics of metal-organic crystals has been studied in low frequency AC magnetic field. Four modes of domain wall motion (Debye relaxation, creep, slide and over - barrier motion (switching)) were distinguished in [MnII(H(R/S)-pn)(H2O)] [MnIII(CN)6]⋅2H2O crystals. Debye relaxation and creep of the domain walls are sensitive to Peierls relief configuration controlled by crystal lattice chirality. Structural defects and periodical Peierls potential compete in the damping of the domain walls. Driving factor of this competition is ratio of the domain wall width to the crystal lattice parameter.


Sign in / Sign up

Export Citation Format

Share Document