scholarly journals Analysis of translational errors in frame-based and frameless cranial radiosurgery using an anthropomorphic phantom

2016 ◽  
Vol 49 (2) ◽  
pp. 98-103 ◽  
Author(s):  
Taynná Vernalha Rocha Almeida ◽  
Arno Lotar Cordova Junior ◽  
Pedro Argolo Piedade ◽  
Cintia Mara da Silva ◽  
Priscila Marins ◽  
...  

Abstract Objective: To evaluate three-dimensional translational setup errors and residual errors in image-guided radiosurgery, comparing frameless and frame-based techniques, using an anthropomorphic phantom. Materials and Methods: We initially used specific phantoms for the calibration and quality control of the image-guided system. For the hidden target test, we used an Alderson Radiation Therapy (ART)-210 anthropomorphic head phantom, into which we inserted four 5mm metal balls to simulate target treatment volumes. Computed tomography images were the taken with the head phantom properly positioned for frameless and frame-based radiosurgery. Results: For the frameless technique, the mean error magnitude was 0.22 ± 0.04 mm for setup errors and 0.14 ± 0.02 mm for residual errors, the combined uncertainty being 0.28 mm and 0.16 mm, respectively. For the frame-based technique, the mean error magnitude was 0.73 ± 0.14 mm for setup errors and 0.31 ± 0.04 mm for residual errors, the combined uncertainty being 1.15 mm and 0.63 mm, respectively. Conclusion: The mean values, standard deviations, and combined uncertainties showed no evidence of a significant differences between the two techniques when the head phantom ART-210 was used.

2021 ◽  
Vol 11 ◽  
Author(s):  
Hua Chen ◽  
Lingxiang Liu ◽  
Hao Wang ◽  
Yan Shao ◽  
Hengle Gu ◽  
...  

PurposeTo explore the influence of clinical and tumor factors over interfraction setup errors with rotation correction for non-small cell lung cancer (NSCLC) stereotactic body radiation therapy (SBRT) patients immobilized in vacuum cushion (VC) to better understand whether patient re-setup could further be optimized with these parameters.Materials and MethodsThis retrospective study was conducted on 142 NSCLC patients treated with SBRT between November 2017 to July 2019 in the local institute. Translation and rotation setup errors were analyzed in 732 cone-beam computed tomography (CBCT) scans before treatment. Differences between groups were analyzed using independent sample t-test. Logistic regression test was used to analyze possible correlations between patient re-setup and clinical and tumor factors.ResultsMean setup errors were the largest in anterior–posterior (AP) direction (3.2 ± 2.4 mm) compared with superior–inferior (SI) (2.8 ± 2.1 mm) and left–right (LR) (2.5 ± 2.0 mm) directions. The mean values were similar in pitch, roll, and rtn directions. Of the fractions, 83.7%, 90.3%, and 86.6% satisfied setup error tolerance limits in AP, SI, and LR directions, whereas 95% had rotation setup errors of <2° in the pitch, roll, or rtn directions. Setup errors were significantly different in the LR direction when age, body mass index (BMI), and “right vs. left” location parameters were divided into groups. Both univariate and multivariable model analyses showed that age (p = 0.006) and BMI (p = 0.002) were associated with patient re-setup.ConclusionsAge and BMI, as clinical factors, significantly influenced patient re-setup in the current study, whereas all other clinical and tumor factors were not correlated with patient re-setup. The current study recommends that more attention be paid to setup for elderly patients and patients with larger BMI when immobilized using VC, especially in the left–right direction.


1871 ◽  
Vol 161 ◽  
pp. 69-75

Results of Seven Years' Observations of the Pip and Horizontal Force . In a paper published in the Philosophical Transactions for 1863, the President of the Royal Society enters into a discussion of a six years’ series of the Kew Magnetic Observations, with the view of ascertaining whether the sun’s position with reference to the earth really produces a sensible semiannual inequality in the terrestrial magnetic elements. The probability of the existence of such a disturbing cause, founded on a comparison of the monthly determinations of the Dip and Horizontal Force taken at Hobarton and at Toronto, was made much more evident by Sir Edward Sabine’s discussion of the Kew observations; and it was from a desire of bringing more data to bear upon this important question that the reduction of the seven years’ observations, just completed at this observatory, has been undertaken. With this object in view, it was considered of great importance to adhere closely to the plan laid down by Sir Edward Sabine, and to present the results, for the sake of comparison, in three Tables. The first contains the mean monthly determinations of the elements, with their deduced mean values and secular variation, the second presents a view of the semiannual inequality, and the third gives the residual errors and the consequent most probable errors of any single observation and of the deduced mean values of the elements. Magnetic observations were first taken at Stonyhurst in 1858, but the continuous, series of monthly determinations of the Dip, Declination, and Intensity were only commencedin March 1863. The same instruments, i. e . a dip-circle by Barrow and a Jones unifilar, have been used throughout the whole seven years. These instruments were both tested at Kew before being sent to this observatory, and the dip-circle was again examined there last January with most satisfactory results. The constants of the vibration-magnet were determined by Mr. W else, and are given in the Proceedings of the Royal Society for February 1865. In calculating the value of the Horizontal Force, it has never been found necessary to apply any correction for the arc of vibration, which has always been small, nor for the Frodsham chronometer, whose rate has never exceeded 2 s per day.


2016 ◽  
Vol 16 (2) ◽  
pp. 231-237 ◽  
Author(s):  
Joe H. Chang ◽  
Arnjeet Sangha ◽  
Derek Hyde ◽  
Hany Soliman ◽  
Sten Myrehaug ◽  
...  

The aim of this study is to determine whether stereotactic body radiotherapy for multiple vertebral metastases treated with a single isocenter results in greater intrafraction errors than stereotactic body radiotherapy for single vertebral metastases and to determine whether the currently used spinal cord planning organ at risk volume and planning target volume margins are appropriate. Intrafraction errors were assessed for 65 stereotactic body radiotherapy treatments for vertebral metastases. Cone beam computed tomography images were acquired before, during, and after treatment for each fraction. Residual translational and rotational errors in patient positioning were recorded and planning organ at risk volume and planning target volume margins were calculated in each direction using this information. The mean translational residual errors were smaller for single (0.4 (0.4) mm) than for multiple vertebral metastases (0.5 (0.7) mm; P = .0019). The mean rotational residual errors were similar for single (0.3° (0.3°) and multiple vertebral metastases (0.3° (0.3°); P = .862). The maximum calculated planning organ at risk volume margin in any direction was 0.83 mm for single and 1.22 for multiple vertebral metastases. The maximum calculated planning target volume margin in any direction was 1.4 mm for single and 1.9 mm for multiple vertebral metastases. Intrafraction errors were small for both single and multiple vertebral metastases, indicating that our strategy for patient immobilization and repositioning is robust. Calculated planning organ at risk volume and planning target volume margins were smaller than our clinically employed margins, indicating that our clinical margins are appropriate.


2021 ◽  
Vol 20 ◽  
pp. 153303382110245
Author(s):  
Dingjie Li ◽  
Shengtao Wei ◽  
Tian Li ◽  
Yang Liu ◽  
Jing Cai ◽  
...  

Purpose: To analyze the setup errors and residual errors of different spinal cord parts in esophageal cancer patients and to explore the necessity of spinal cord segmental expansion. Methods and Materials: Sixty cases of esophageal cancer were included with 20 patients subdivided into the following groups: neck, chest and abdomen as per the treatment site. The patients underwent intensity modulated radiation therapy (IMRT) between 2017 and 2019. Thermoplastic mask or vacuum bag were utilized for immobilization of different groups. CTVision (Siemens CT-On-Rail system) was used to acquire pre-treatment CT, and 20 consecutive pre-treatment CT datasets were collected for data analysis for each case. Images were exported to MIM (MIM Software Inc.) for processing and data analysis. Dice coefficient, maximum Hausdorff distance and centroid coordinate values between the spinal cord contours in the pre-treatment CTs and the planning CT were calculated and extracted. The contour expansion margin value is calculated as MPRV = 1.3 ∑ total + 0.5 σ total, where ∑ total and σ total are the systematic and random error, respectively. Results: For neck, chest, abdominal segments of the spinal cord, the mean Dice coefficients (± SD) are 0.73 ± 0.06, 0.80 ± 0.06, 0.82 ± 0.06, the maximum Hausdorff distance residual error (± SD) are 4.46 ± 0.55, 3.49 ± 0.53, 3.46 ± 0.69 mm, and the mean centroid coordinate residual error (± SD) are 2.40 ± 0.53, 1.66 ± 0.47, 2.14 ± 0.95 mm, respectively. The calculated margin using residual centroid method in medial-lateral (ML), anterior-posterior (AP), and cranial-caudal (CC) direction of spinal cord in neck, chest, abdominal segments are 3.86, 5.37, 6.36 mm, 3.45, 3.83, 4.51 mm, 4.05, 4.83, 7.06 mm, respectively, and the calculated margin using residual Hausdorff method are 3.10, 5.33 and 6.15 mm, 3.30, 3.77, 4.61 mm, 3.35, 4.76, 6.87 mm, respectively. Conclusion: The setup errors and residual errors are different in each segment of the spinal cord. Different margins expansion should be applied to different segment of spinal cord.


2021 ◽  
Vol 21 (1) ◽  
Author(s):  
Jiang Wang ◽  
Yi Lv ◽  
Junchen Wang ◽  
Furong Ma ◽  
Yali Du ◽  
...  

Abstract Background Segmentation of important structures in temporal bone CT is the basis of image-guided otologic surgery. Manual segmentation of temporal bone CT is time- consuming and laborious. We assessed the feasibility and generalization ability of a proposed deep learning model for automated segmentation of critical structures in temporal bone CT scans. Methods Thirty-nine temporal bone CT volumes including 58 ears were divided into normal (n = 20) and abnormal groups (n = 38). Ossicular chain disruption (n = 10), facial nerve covering vestibular window (n = 10), and Mondini dysplasia (n = 18) were included in abnormal group. All facial nerves, auditory ossicles, and labyrinths of the normal group were manually segmented. For the abnormal group, aberrant structures were manually segmented. Temporal bone CT data were imported into the network in unmarked form. The Dice coefficient (DC) and average symmetric surface distance (ASSD) were used to evaluate the accuracy of automatic segmentation. Results In the normal group, the mean values of DC and ASSD were respectively 0.703, and 0.250 mm for the facial nerve; 0.910, and 0.081 mm for the labyrinth; and 0.855, and 0.107 mm for the ossicles. In the abnormal group, the mean values of DC and ASSD were respectively 0.506, and 1.049 mm for the malformed facial nerve; 0.775, and 0.298 mm for the deformed labyrinth; and 0.698, and 1.385 mm for the aberrant ossicles. Conclusions The proposed model has good generalization ability, which highlights the promise of this approach for otologist education, disease diagnosis, and preoperative planning for image-guided otology surgery.


1980 ◽  
Vol 23 (3) ◽  
pp. 630-645 ◽  
Author(s):  
Gerald Zimmermann ◽  
J.A. Scott Kelso ◽  
Larry Lander

High speed cinefluorography was used to track articulatory movements preceding and following full-mouth tooth extraction and alveoloplasty in two subjects. Films also were made of a control subject on two separate days. The purpose of the study was to determine the effects of dramatically altering the structural dimensions of the oral cavity on the kinematic parameters of speech. The results showed that the experimental subjects performed differently pre and postoperatively though the changes were in different directions for the two subjects. Differences in both means and variabilities of kinematic parameters were larger between days for the experimental (operated) subjects than for the control subject. The results for the Control subject also showed significant differences in the mean values of kinematic variables between days though these day-to-day differences could not account for the effects found pre- and postoperatively. The results of the kinematic analysis, particularly the finding that transition time was most stable over the experimental conditions for the operated subjects, are used to speculate about the coordination of normal speech.


1986 ◽  
Vol 55 (01) ◽  
pp. 108-111 ◽  
Author(s):  
M Köhler ◽  
P Hellstern ◽  
C Miyashita ◽  
G von Blohn ◽  
E Wenzel

SummaryThis study was performed to evaluate the influence of different routes of administration on the efficacy of DDAVP treatment. Ten healthy volunteers received DDAVP intranasally (i.n.), subcutaneously (s.c.) and intravenously (i.v.) in a randomized cross-over trial. Factor XII and high molecular weight (HMW)-kininogen levels increased only slightly after DDAVP administration. The mean increase of factor VIII: C was 3.1 (i. v.), 2.3 (s. c.), and 1.3 (i.n.) - fold over baseline. Ristocetin cofactor (von Willebrand factor antigen) increased 3.1 (2.5), 2.0 (2.3) and 1.2 (1.2) - fold over baseline mean values after i.v., s.c. and i.n. DDAVP, respectively. The half-disappearance time of factor VIII and von Willebrand factor (vWF) after DDAVP ranged from five (factor VIII: C) to eight hours (vWF). The mean increase of fibrinolytic activity was more pronounced after i.v. DDAVP. The antidiuretic effect was moderate with no apparent differences between the routes of application. This study provides further evidence that both i.v. and s.c. DDAVP administration result in an appropriate and reliable stimulation of haemostasis. An additional advantage of s. c. administration is its suitability for home treatment.


2018 ◽  
Vol 4 (4) ◽  
pp. 519-522
Author(s):  
Jeyakumar S ◽  
Jagatheesan Alagesan ◽  
T.S. Muthukumar

Background: Frozen shoulder is disorder of the connective tissue that limits the normal Range of motion of the shoulder in diabetes, frozen shoulder is thought to be caused by changes to the collagen in the shoulder joint as a result of long term Hypoglycemia. Mobilization is a therapeutic movement of the joint. The goal is to restore normal joint motion and rhythm. The use of mobilization with movement for peripheral joints was developed by mulligan. This technique combines a sustained application of manual technique “gliding” force to the joint with concurrent physiologic motion of joint, either actively or passively. This study aims to find out the effects of mobilization with movement and end range mobilization in frozen shoulder in Type I diabetics. Materials and Methods: 30 subjects both male and female, suffering with shoulder pain and clinically diagnosed with frozen shoulder was recruited for the study and divided into two groups with 15 patients each based on convenient sampling method. Group A patients received mobilization with movement and Group B patients received end range mobilization for three weeks. The outcome measurements were SPADI, Functional hand to back scale, abduction range of motion using goniometer and VAS. Results: The mean values of all parameters showed significant differences in group A as compared to group B in terms of decreased pain, increased abduction range and other outcome measures. Conclusion: Based on the results it has been concluded that treating the type 1 diabetic patient with frozen shoulder, mobilization with movement exercise shows better results than end range mobilization in reducing pain and increase functional activities and mobility in frozen shoulder.


1966 ◽  
Vol 53 (2) ◽  
pp. 177-188 ◽  
Author(s):  
P. Lund-Johansen ◽  
T. Thorsen ◽  
K. F. Støa

ABSTRACT A comparison has been made between (A), a relatively simple method for the measurement of aldosterone secretion rate, based on paper chromatography and direct densitometry of the aldosterone spot and (B) a more elaborate isotope derivative method. The mean secretion rate in 9 normal subjects was 112 ± 26 μg per 24 hours (method A) and 135 ± 35 μg per 24 hours (method B). The »secretion rate« in one adrenalectomized subject after the intravenous injection of 250 μg of aldosterone was 230 μg per 24 hours (method A) and 294 μg per 24 hours (method B). There was no significant difference in the mean values, and correlation between the two methods was good (r = 0.80). It is concluded that the densitometric method is suitable for clinical purposes as well as research, being more rapid and less expensive than the isotope derivative method. Method A also measures the urinary excretion of the aldosterone 3-oxo-conjugate, which is of interest in many pathological conditions. The densitometric method is obviously the less sensitive and a prerequisite for its use is an aldosterone secretion of 20—30 μg per 24 hours. Lower values are, however, rare in adults.


1970 ◽  
Vol 64 (2) ◽  
pp. 265-272 ◽  
Author(s):  
A. A. van der Gugten ◽  
M. Sala ◽  
H. G. Kwa

ABSTRACT Eight female and eight male rats were castrated at the age of 8 to 10 weeks. Four spayed and four orchidectomized rats received one oestrone/cholesterol pellet (200 μg oestrone) on the day of operation (day 0), a second pellet on day 11 and a third on day 23. The remaining animals received four oestrone/cholesterol pellets at these times. The fluctuations in the prolactin levels in the circulation induced by the oestrogen challenges in these animals were followed during 31 days by radioimmunoassays performed on days 3, 7, 9, 14, 15, 17, 23, 24, 25, 28 and 31. The results suggested that the homoeostatic mechanism regulating plasma levels of prolactin was capable of withstanding the three time-spaced oestrogen challenges only in the spayed animals receiving the lower doses of oestrogen, since it allowed the mean values of the prolactin levels to remain fairly constant during the first 4 weeks. The levels in this group rose to much higher levels only on day 31. The higher doses of oestrone in the spayed rats and both dose levels of oestrone in the orchidectomized animals apparently resulted in a primary break-down of the homoeostatic mechanism, since the prolactin levels in the animals of these groups rose to much higher levels either on day 7 or on day 9. This was followed by a period during which the prolactin levels appeared to be more or less under control, until a second and probably definitive failure of the homoeostatic mechanism allowed the mean levels to rise sharply again.


Sign in / Sign up

Export Citation Format

Share Document