scholarly journals Safety of the effective radiation dose received during stroke hospitalization

2021 ◽  
Vol 20 ◽  
Author(s):  
Gregório Platero Canton ◽  
Gustavo José Luvizutto ◽  
Pedro Tadao Hamamoto Filho ◽  
Marcos Ferreira Minicucci ◽  
Gabriel Pinheiro Modolo ◽  
...  

Abstract Background Neuroimaging is widely used for diagnosis and treatment of stroke. However, little is known about whether the radiation doses received by patients comply with international safety guidelines. Objectives The aim of this study was to evaluate the effective radiation dose received while in hospital for stroke and analyze its safety according to current guidelines. Methods This cross-sectional study included 109 patients who were hospitalized and diagnosed with ischemic stroke. The National Institutes of Health Stroke Scale was used to evaluate stroke severity, the Bamford clinical classification was used for topography, and the TOAST classification was used for etiology. The computed tomography dose index and size-specific dose estimates were used to calculate the effective radiation dose (ERD) received while in hospital. A Mann-Whitney test was used to compare the ERD received by thrombolysed and non-thrombolysed patients. Non-parametric statistics were used to analyze the data with a 95% confidence interval. Results During the study period, the median ERD received was 10.9 mSv. Length of stay was not associated with radiation exposure. No differences were demonstrated in ERD according to stroke etiology or Bamford clinical classification. Patients who had CT perfusion (only or in addition to CT or angiotomography) received the highest ERD (46.5 mSv) and the difference compared to those who did not (10.8 mSv) was statistically significant (p<0.001). No differences were found in the ERD between thrombolysed and non-thrombolysed patients. There was no correlation between ERD while in hospital and stroke severity. Conclusions According to the current national guidelines, the protocol for examining images at our stroke unit is safe in terms of the ERD received by the patient while in hospital. There was no difference in the ERD received by patients stratified by thrombolytic treatment or stroke severity.

2018 ◽  
Vol 38 (1) ◽  
Author(s):  
Yuning Pan ◽  
Aiqin Song ◽  
Shizhong Bu ◽  
Zhaoqian Chen ◽  
Qiuli Huang ◽  
...  

Aim: To investigate the feasibility of low-concentration contrast (270 mg/ml) together with low tube voltage (80 kV) and adaptive iterative dose reduction (AIDR)-3D reconstruction in liver computed tomography (CT) perfusion imaging. Method: A total of 15 healthy New Zealand rabbits received two CT scans each. The first scan (control) was acquired at 100 kV and 100 mA with iopromide (370 mg/ml), while the second scan (experimental) was acquired at 80 kV and 100 mA with iodixanol (270 mg/ml) 24 h after the first scan. The obtained images were reconstructed with filtered back projection (FBP) and AIDR-3D in the control and experimental groups respectively. The perfusion parameters (hepatic artery perfusion [HAP], portal vein perfusion [PVP], hepatic perfusion index [HPI], and total liver perfusion [TLP]) and image quality (image quality score, average CT value of abdomen aorta, signal-to-noise ratio [SNR], contrast-to-noise ratio [CNR], and figure of merit [FOM]) were compared using a paired t-test or Mann–Whitney U test between the two groups, when appropriate. The effective radiation dose and iodine intake were also recorded and compared. Results: With the exception of the FOM criteria, the image quality and perfusion parameters were not significantly different between the two groups. The effective radiation dose and iodine intake were 38.79% and 27.03% lower respectively, in the experimental group. Conclusion: Low-concentration contrast (iodixanol, 270 mg/ml) together with low tube voltage (80 kV) and AIDR-3D reconstruction help to reduce radiation dose and iodine intake without compromising perfusion parameters and image quality in liver CT perfusion imaging.


BMJ Open ◽  
2018 ◽  
Vol 8 (3) ◽  
pp. e019535 ◽  
Author(s):  
Jorge Vilar-Palop ◽  
Ildefonso Hernandez-Aguado ◽  
María Pastor-Valero ◽  
José Vilar ◽  
Isabel González-Alvarez ◽  
...  

ObjectivesTo determine the appropriateness of medical imaging examinations involving radiation and to estimate the effective radiation dose and costs associated.DesignCross-sectional retrospective study.SettingTwo Spanish public tertiary hospitals.Participants2022 medical imaging tests were extracted from the radiology information system in February and March of 2014. MRI and ultrasound examinations were excluded.Primary and secondary outcome measuresFive outcomes were set independently by at least two researchers according to four guidelines: (1) appropriate; (2) inappropriate; (3) inappropriate due to repetition, if the timing to carry out next diagnostic tests was incorrect according to guidelines; (4) not adequately justified, if the referral form did not include enough clinical information to allow us to understand the patient’s clinical condition; and (5) not included in the guidelines, if the referral could not be matched to a clinical scenario described in the guidelines. We estimated the prevalence of the five categories according to relevant clinical and sociodemographic variables and the effective radiation dose and costs for each category.ResultsApproximately half of the imaging tests were deemed as appropriate (967, 47.8%) while one-third (634, 31.4%) were considered inappropriate. 19.6% of the effective dose and 25.2% of the cost were associated with inappropriate tests. Women were less likely than men to have an imaging test classified as appropriate (adjusted OR 0.70,95% CI 0.57 to 0.86). Imaging tests requested by general practitioners were less likely to be considered appropriate than those requested by central services (adjusted OR 0.60, 95% CI 0.38 to 0.93). Mammography and CT were more likely to be appropriate than conventional X-rays.ConclusionThere was a significant frequency of inappropriateness, which resulted in a high percentage of associated effective radiation dose. Percentage of inappropriateness depends on sociodemographic and clinical characteristics such as sex, age, referral physician and medical imaging test.


2010 ◽  
Vol 49 (05) ◽  
pp. 173-182 ◽  
Author(s):  
G. Vincenti ◽  
A. Quercioli ◽  
H. Zaidi ◽  
R. Nkoulou ◽  
S. Dewarrat ◽  
...  

Summary Purpose: To evaluate the mean effective radiation dose of 13N-ammonia PET/CT and ECGpulsing CT angiography (CTA) in the evaluation of myocardial perfusion, myocardial blood flow (MBF) and coronary morphology for the identification of subclinical CAD. Patients, material, methods: Following rest-stress 13N-ammonia PET/CT perfusion imaging and MBF quantification, ECG-pulsing CTA at a pulse window of 70% of the R-R cycle was performed in ten healthy controls and in sixteen individuals with cardiovascular risk factors. Individual radiation dose exposure for ECG-pulsing CTA was estimated from the dose-length product. Results: PET demonstrated normal perfusion in all study individuals, while hyperemic MBFs during dipyridamole stimulation and the myocardial flow reserve (MFR) in cardiovascular risk individuals were significantly lower than in healthy controls (1.34 ± 0.26 vs. 2.28 ± 0.47 ml/g/min and 1.48 ± 0.39 vs. 3.24 ± 0.81, both p . 0.0001). Further, ECG-pulsing CTA identified mild calcified and non-calcified coronary plaque burden in 7 (43%) individuals of the cardiovascular risk group. Rest-stress 13N-ammonia PET/CT perfusion study yielded a mean effective radiation dose of 3.07 ± 0.06 mSv (2.07 ± 0.06 mSv from the rest-stress 13N-ammonia injections and 1.0 mSv from the 2 CT transmission scans), while ECG-pulsing CTA was associated with 5.57 ± 2.00 mSv. The mean effective radiation dose of the combined 13N-ammonia PET/CT and ECG-pulsing CTA exams in the evaluation of myocardial perfusion and coronary morphology was 8.0 ± 1.5 mSv. Conclusion: 13N-ammonia PET/CT and ECG-pulsing CTA affords cardiac hybrid imaging studies in the evaluation of subclinical CAD with a relatively low mean effective radiation exposure of 8.0 ± 1.5mSv.


2017 ◽  
Vol 8 (1) ◽  
pp. 10
Author(s):  
Narendra Kumar Singh ◽  
Nishant Goyal

Background: Schizophrenia is associated with a high familial, social and economic burden. Schizophrenia is also associated with a high level of disability which may create impediments on the social and economic areas of the patients as well as on their respective family networks. Families with schizophrenia may encounter problems such as impairment of health and well being of other family members, restriction of social activities of the family members and shrinking of support from the social network. Aims: The present study examined the difference in perceived social support and burden of care between the male and female caregivers of patients with schizophrenia. Methods: This was a cross-sectional study examining the difference in perceived social support and burden of care between the male and female caregivers of patients with schizophrenia. The sample consisted of 60 (30 male and 30 female) caregivers of the patients with the diagnosis of schizophrenia as per ICD-10-DCR. Results and Conclusion: This study revealed that male caregivers perceived more social support and less burden of care as compared to female caregivers. Key words: Gender, social support, burden


2020 ◽  
Vol 20 (5) ◽  
pp. 748-751
Author(s):  
Seyed Ali Dehghan Manshadi ◽  
Neda Alijani ◽  
Mohammadreza Salehi ◽  
Omid Dadras ◽  
SeyedAhmad SeyedAlinaghi ◽  
...  

Introduction: The aim of this study was to determine the prevalence of exposure to hepatitis A by means of serologic markers in chronic hepatitis B patients, with the secondary aim of finding the best prevention method for hepatitis A infection in susceptible groups of our setting. Methods: During the period between 2016 and 2017, we recruited 403 hepatitis B patients aged more than 14 years and regularly attending the infectious diseases clinic at a referral university hospital, Tehran, Iran. A blood sample was collected from all the patients and tested for hepatitis A IgG. The data was analyzed by SPSS v.19. Results: Although none of the patients had previously received hepatitis A vaccine, the results for serologic level of hepatitis A IgG, demonstrated positive results in 379 (94%) cases. The mean age of patients with negative and positive IgG was 29.17 and 42.46 years, respectively; the difference was statistically significant (P≤0.001). The majority of seronegative patients were young adults aged < 25 years and 25 to 35 years (P <0.001). Conclusion: Seroprevalence of hepatitis A in chronic HBV patients in Iran is high. As HBV infected patients younger than 35 years could be seronagative for HAV infection, evaluation of these patients for HAV infection and vaccination of seronegative patients would be a reasonable approach.


Author(s):  
Erika Viktória Miszory ◽  
Melinda Járomi ◽  
Annamária Pakai

Abstract Aim The number of Hungarian polio patients can be estimated at approximately 3000. Polio infection is currently affecting people 56–65 years of age. The aim of the study was to reveal the quality of life of patients living with polio virus in Hungary. Subject and methods The quantitative cross-sectional study was conducted in January–April 2017 among polyomyelitis patients living in Hungary. In the non-random, targeted, expert sample selection, the target group was composed of patients infected with poliovirus (N = 268). We have excluded those who refused to sign the consent statement. Our data collection method was an SF-36 questionnaire. Using the IBM SPSS Statistics Version 22 program, descriptive and mathematical statistics (χ2-test) were calculated (p < 0.05). Results The mean age of the members of the examined population is 63.5 years; 68.1% were women and 31.90% were men. The majority of the respondents were infected by the polyovirus in 1956 (11.9%), 1957 (24.3%), and 1959 (19.5%). Polio patients, with the exception of two dimensions (mental health, social operation), on the scale of 100 do not reach the “average” quality of life (physical functioning 23 points, functional role 36 points, emotional role 47 points, body pain 48 points, general health 42 points, vitality 50 points, health change 31 points). Conclusion The quality of life of polio patients is far below the dimensions of physical function, while the difference in mental health compared to healthy people is minimal. It would be important to educate health professionals about the existing disease, to develop an effective rehabilitation method.


Author(s):  
Rosalía Romero-Tena ◽  
Carmen Llorente-Cejudo ◽  
María Puig-Gutiérrez ◽  
Raquel Barragán-Sánchez

Without having a reaction time, the pandemic has caused an unprecedented transformation in universities around the world, leading to a revolution from structured models anchored in the conception of transmission of training towards a teaching approach-learning saved thanks to the incorporation of technology. This study aims to verify whether the pandemic situation has influenced the digital competence self-perception of students. Comparing two groups during the academic years 2019/2020 and 2020/2021, the instrument used is the questionnaire for digital competence “DigCompEdu Check-In” for future teachers. After the educational intervention, group A (before COVID-19) presented higher self-perceptions of competence than group B (during COVID-19); the pandemic situation caused by COVID-19 has negatively influenced students’ self-perception of their digital skills in the pretest in the different dimensions under study. Before receiving the training, the group that did not experience the pandemic enjoyed a higher self-perception of their competencies than the group that experienced the pandemic. The data obtained indicate that the difference exists, and that it is statistically significant, and may be a consequence of the clear relationship between self-perception and the way in which students face reality through their personal and subjective vision.


2016 ◽  
Vol 171 ◽  
pp. 310-312 ◽  
Author(s):  
Rachel P. Berger ◽  
Ashok Panigrahy ◽  
Shawn Gottschalk ◽  
Michael Sheetz

2020 ◽  
Vol 30 (Supplement_5) ◽  
Author(s):  
R Bosco ◽  
S Gambelli ◽  
V Urbano ◽  
G Cevenini ◽  
G Messina

Abstract Background Sanitizing the operating theatres (OT) is important to minimize risk of post-operative infections. Disinfection procedures between one operation and another is less aggressive than final cleaning procedures, at the end of the day. Aim was assessing the difference of contamination: i) between different levels of disinfection; ii) before and after the use of a UVC Device (UVC-D). Methods Between December 2019/February 2020 a cross sectional study was conducted in OT in a real clinical context. 94 Petri dishes (PD) were used in 3 OT. Three different sanitation levels (SL1-3) were compared pre- and post-use of UVC-D: i) No cleaning after surgery (SL1); ii) after in-between cleaning (SL2); iii) after terminal cleaning (SL3). UVC-D was employed for 6 minutes, 3 minutes per bed side. PD were incubated at 36 °C and colony forming unit (CFU) counted at 48h. Descriptive statistic, Wilcoxon and Mann-Whitney tests were performed to assess the contamination levels in total, pre/post use of UVC-D, and between different sanitation levels, respectively. Results In total we had a mean of 3.39 CFU/PD (C.I. 2.05 - 4.74) and a median of 1 CFU/PD (Min. 0 - Max. 39), after UVC-D use we had a mean of 2.20 CFU/PD (C.I. 0.69 - 5.09) and a median of 0 CFU/PD (Min. 0 - Max. 133). The UVC-D led to a significant reduction of CFU (p &lt; 0.001). Without UVC-D we had a significant CFU drop (p &lt; 0.05) between SL1 and SL3. Using UVC-D, we observed significant reductions of contamination (p &lt; 0.05) between SL3 and SL1. Comparing SL1 (median 0) post UVC-D use vs SL2 pre UVC-D use (median 0.5), and SL2 post UVC-D use (median 0) vs SL3 pre UVC-D use (median 1) we had a significant reduction of contamination (p &lt; 0.05). Conclusions UVC-D improved environmental contamination in any of the three sanitation levels. Furthermore, the use of UVC-D alone was better than in-between and terminal cleaning. Although these encouraging results, the cleaning procedures executed by dedicated staff has to be considered. Key messages UVC are efficient to decrease contamination in operating theatres regardless of sanitation levels. The additional use of UVC technology to standard cleaning procedures significantly improves sanitation levels.


Sign in / Sign up

Export Citation Format

Share Document