Numerical Study of the Flow in the Flow Path of a Centrifugal Natural Gas Compressor at Different Positions of the Inlet Guide Vane

Author(s):  
M.V. Krutikov ◽  
V.L. Blinov

The paper focuses on the problem of a possible expansion of the range of operating modes of a centrifugal natural gas compressor due to the rotation of the inlet guide vanes at different rotor speeds. The geometry of the flow path of the investigated object, obtained by three-dimensional scanning, is presented. On its basis, a numerical model is built and the influence of various factors of the formulation of the computational problem on the results of modeling the gas flow in the flow path of the compressor is analyzed. The calculations were performed using the k--ε and SST turbulence models for various parameters of the computational grid and conditions for averaging the flow parameters between the computational domains. The results obtained were compared with the nameplate and operational data. Recommendations on the formulation of the modeling problem are proposed, the results of the calculations are described, and the characteristics of the centrifugal compressor are plotted at different angles of the inlet guide vanes in a wide range of rotor speeds. The possible range of expansion of the operating modes of the investigated compressor is described, which can be provided by varying the position of the inlet guide vane

Author(s):  
Sang-Won Kim ◽  
Youn-Jea Kim

An axial-flow pump has a relatively high discharge flow rate and specific speed at a relatively low head and it consists of an inlet guide vane, impeller, and outlet guide vane. The interaction of the flow through the inlet guide vane, impeller, and outlet guide vane of the axial-flow pump has a significant effect on its performance. Of those components, the guide vanes especially can improve the head and efficiency of the pump by transforming the kinetic energy of the rotating flow, which has a tangential velocity component, into pressure energy. Accordingly, the geometric configurations of the guide vanes such as blade thickness and angle are crucial design factors for determining the performance of the axial-flow pump. As the reliability of Computational Fluid Dynamics (CFD) has been elevated together with the advance in computer technology, numerical analysis using CFD has recently become an alternative to empirical experiment due to its high reliability to measure the flow field. Thus, in this study, 1,200mm axial-flow pump having an inlet guide vane and impeller with 4 blades and an outlet guide vane with 6 blades was numerically investigated. Numerical study was conducted using the commercial CFD code, ANSYS CFX ver. 16.1, in order to elucidate the effect of the thickness and angle of the guide vanes on the performance of 1,200mm axial-flow pump. The stage condition, which averages the fluxes between interfaces and is accordingly appropriate for the evaluation of pump performance, was adopted as the interface condition between the guide vanes and the impeller. The rotational periodicity condition was used in order to enable a simplified geometry to be used since the guide vanes feature multiple identical regions. The shear stress transport (SST) k-ω model, predicting the turbulence within the flow in good agreement, was also employed in the CFD calculation. With regard to the numerical simulation results, the characteristics of the pressure distribution were discussed in detail. The pump performance, which will determine how well an axial-flow pump will work in terms of its efficiency and head, was also discussed in detail, leading to the conclusion on the optimal blade thickness and angle for the improvement of the performance. In addition, the total pressure loss coefficient was considered in order to investigate the loss within the flow paths depending on the thickness and angle variations. The results presented in this study may give guidelines to the numerical analysis of the axial-flow pump and the investigation of the performance for further optimal design of the axial-flow pump.


Author(s):  
Ashlie B. Flegel

Abstract A Honeywell Uncertified Research Engine was exposed to various ice crystal conditions in the NASA Glenn Propulsion Systems Laboratory. Simulations using NASA’s 1D Icing Risk Analysis tool were used to determine potential inlet conditions that could lead to ice crystal accretion along the inlet of the core flowpath and into the high pressure compressor. These conditions were simulated in the facility to develop baseline conditions. Parameters were then varied to move or change accretion characteristics. Data were acquired at altitudes varying from 5 kft to 45 kft, at nominal ice particle Median Volumetric Diameters from 20 μm to 100 μm, and total water contents of 1 g/m3 to 12 g/m3. Engine and flight parameters such as fan speed, Mach number, and inlet temperature were also varied. The engine was instrumented with total temperature and pressure probes. Static pressure taps were installed at the leading edge of the fan stator, front frame hub, the shroud of the inlet guide vane, and first two rotors. Metal temperatures were acquired for the inlet guide vane and vane stators 1–2. In-situ measurements of the particle size distribution were acquired three meters upstream of the engine forward fan flange and one meter downstream of the fan in the bypass in order to study particle break-up behavior. Cameras were installed in the engine to capture ice accretions at the leading edge of the fan stator, splitter lip, and inlet guide vane. Additional measurements acquired but not discussed in this paper include: high speed pressure transducers installed at the trailing edge of the first stage rotor and light extinction probes used to acquire particle concentrations at the fan exit stator plane and at the inlet to the core and bypass. The goal of this study was to understand the key parameters of accretion, acquire particle break-up data aft of the fan, and generate a unique icing dataset for model and tool development. The work described in this paper focuses on the effect of particle break-up. It was found that there was significant particle break-up downstream of the fan in the bypass, especially with larger initial particle sizes. The metal temperatures on the inlet guide vanes and stators show a temperature increase with increasing particle size. Accretion behavior observed was very similar at the fan stator and splitter lip across all test cases. However at the inlet guide vanes, the accretion decreased with increasing particle size.


Author(s):  
Masoud Kharati-Koopaee ◽  
Hossein Moallemi

This research aims at the numerical study of the blade tip grooving effect on the performance of a ducted axial fan at different tip clearances in the absence and presence of inlet guide vanes. To do this, significant parameters of the fan (i.e. pressure and torque coefficients as well as fan efficiency) comprising single- and double-grooved tips are evaluated and compared with those of the original fan. Validation of the considered numerical model is performed through comparison of the numerical findings with experimental results of a single-stage ducted fan, which comprises a set of 37 guide vane and 24-blade rotor rotating at the speed of 3600 r/min. Results reveal that grooving the blade tip causes the fan parameters to increase and higher fan parameters could be attained adopting single-grooved tip. It is shown that employing grooved blades causes the sensitivity of fan parameters to the change in the tip clearance to diminish. Results exhibit that the impact of grooving the blade on the reduction of sensitivity of fan parameters to the change in the tip clearance for the single-grooved tip in the absence of guide vanes is more remarkable than the other cases and in this case, as the tip clearance increases from the lower to the upper considered value, the decreased percentages in pressure coefficient, torque coefficient, and fan efficiency are 29.8%, 8.9%, and 22.8%, respectively. Numerical findings show that the influence of grooving the blade on the fan parameters in the presence of guide vanes is lower than that without guide vanes and in the presence of guide vanes, the highest average increase percentages in pressure coefficient, torque coefficient, and fan efficiency relative to those of the original fan, which is observed in the single grooved tip, are 3.1%, 1.4%, and 1.7%, respectively.


Author(s):  
Wei-Min Feng ◽  
Jing-Ye Pan ◽  
Zhi-Wei Guo ◽  
Qian Cheng

The effects of variable-inlet guide vanes on the performance of an axial flow pump considering tip clearance are investigated. The performance and the main flow field of the whole passage with five different angles of inlet guide vanes ( −10°, −5°, 0°, 5°, 10°) and with two tip clearance sizes (1‰ and 2‰) are presented. The results show that when the angle of inlet guide vane increases from negative values to positive values, the pump head reduces for two tip clearance sizes. This is mainly caused by the change of inlet velocity triangle of blade. Moreover, as tip clearance size increases from 1‰ to 2‰, both the pump head and efficiency decrease because of increasing of the strength of tip clearance leakage vortex and reverse flow.


1961 ◽  
Vol 83 (4) ◽  
pp. 371-378
Author(s):  
A. J. Stepanoff

The function and effectiveness of the inlet guide vanes to control the blower output and power requirements are examined. Calculated and experimental results of the power reduction by means of guide vanes are presented. The concept of the “Inlet Specific Speed” widely used in centrifugal pump field is discussed in application to the blowers. A method of estimating the performance of single-stage blowers for any position of the guide vanes is suggested. A “casing characteristic” is introduced for this purpose and its utility for the calculation of the impeller diameter for a reduction of the output is demonstrated. The performance of the inlet vanes of multistage blowers is reviewed.


Author(s):  
Zhiwei Guo ◽  
Jingye Pan ◽  
Zhongdong Qian ◽  
Bin Ji

The effect of the inlet guide vanes on cavitation performance of an axial pump is investigated to assess the mechanism for cavitation in pumps and improve their cavitation performance. The effect of inlet guide vane angles on cavitation performance was assessed experimentally, and computational fluid dynamics was used to analyze the inner flow field of the axial pump and to probe the cavitation mechanism. The simulation results agree qualitatively with the experimental data, showing that cavitation performance is improved with positive inlet guide vane angles but hampered with negative ones. The cavitation performance itself is controlled by the cavitation volume, which first expands circumferentially when the net positive suction head decreases from a certain large value and then develops toward the axis radially after the net positive suction head reaches a certain value. This is when the cavitation performance deteriorates. Comparing cavitation volume for the critical net positive suction head as determined by two different methods, the method based on efficiency drop (NPSHeff.,1%) is found to be more suitable than that based on head drop (NPSHhead.,3%). Furthermore, the distribution of swirl is shown to be closely related to the distribution of cavitation, a feature that may be used to predict cavitation along the impeller.


Author(s):  
Armin Zemp ◽  
Reza S. Abhari ◽  
Beat Ribi

Forming the first part of a two-part paper, the quantification of the resonant response levels and the damping quantities for a centrifugal compressor impeller with variable inlet guide vanes under engine representative operating conditions is detailed in this work. The motivation for the investigation is the lack of experimental data that are needed to improve and validate computational tools used during the design phase. Measurements were performed during resonant blade vibrations with the inlet pressure, the inlet guide vane angle and the operating point as the varying parameters. The flow non-uniformity introduced into the inlet flow field was measured with an aerodynamic probe. These measurements showed an increase in flow distortion for increased guide vane angles. The response amplitudes were acquired with dynamic strain gauges. A curve-fit method was applied to estimate the critical damping ratios. The results showed a linear correlation of the aerodynamic damping with the inlet pressure. The mode dependent material damping was therefore derived using a linear extrapolation to vacuum conditions of the inlet pressure dependent overall damping. The resonant blade dynamics could be captured with a single degree of freedom model. The aerodynamic damping and the maximum strain response were found to significantly depend on the inlet guide vane angle setting and on the throttle setting of the compressor.


Author(s):  
Srinuvasu Dakuri ◽  
Bhaskar Roy

A free turbine is intended to produce the effect of a rotating flow field to be fed into a strutted annular diffuser for simulating a 3D fluid mechanic interaction and effect. This turbine is driven by the flow from a flow driver fan, upstream of the turbine. As sufficient pressure is required for the diffuser air flow, the concept of maximum work generation by a turbine is bypassed in the design intent. An inlet guide vane is designed for the turbine such that the rotational speed of the turbine matches the design intended speed and also produces an axial exit flow (no swirl) at design condition, and a rotating wake for off design conditions. The consideration of using of the inlet guide vanes (rather than usual stator-nozzles) is to avoid a mismatch between the absolute angle of the flow coming from the flow driver fan and the absolute design intent flow angle requirement, to run the turbine. Also, due to the 3D flow effects, some uncertainty exists in determining the exact entry air flow angle to the guide vane; this uncertainty is provided for with a rounded leading edge to the inlet guide vanes. The above design considerations when embedded in the conventional turbine design procedure resulted in an unusual turbine design with very low blade cambers.


2018 ◽  
Vol 10 (1) ◽  
pp. 168781401774770
Author(s):  
Hui Cao ◽  
Zhenggui Zhou ◽  
Jinhuan Zhang

A core-driven fan stage operates in both single bypass and double bypass modes. There are large differences in aerodynamic parameters between the two modes. To accommodate the differences, the inlet guide vanes must turn in a very large angle, which may cause significant flow losses. To reduce the flow losses, this article investigates three design schemes in detail using the flow field simulation method. The three schemes investigated include the inlet guide vanes adjusting entirely (Scheme 1), the rear part of the inlet guide vanes adjusting (Scheme 2), and both the front and rear part of the inlet guide vanes adjusting (Scheme 3). Comparisons of the three design schemes suggest that the flow losses in Scheme 1 are higher than those in the other two schemes and that the flow losses in Scheme 3 are not evidently lower than those in Scheme 2. The key geometrical parameters of Schemes 1 and 2 are determined for low flow losses and are used to design the inlet guide vanes. The inlet guide vanes are applied to a core-driven fan stage, and the flow fields are simulated by a three-dimensional flow simulation method to confirm the designs.


1980 ◽  
Vol 102 (1) ◽  
pp. 75-80 ◽  
Author(s):  
N. Venkatrayulu ◽  
D. Prithvi Raj ◽  
R. G. Narayanamurthi

This paper presents the results of experimental investigations on the three-dimensional flow and performance characteristics of a free vortex axial flow fan rotor, with a freely rotating and braked inlet guide vane row. The influences of axial distance between the inlet guide vane row and the rotor inlet, inlet guide vane setting angle and shape, partial omission of guide vanes at the hub and tip regions on the return flows have been studied and optimum axial distance and setting angle that will improve the useful operating range of the fan were determined. Use of freely rotating inlet guide vanes at high flow volumes and braked inlet guide vanes at low flow coefficients resulted in a reduction of return flows and an increase of the stable operating range of the axial fan rotor by more than 35 percent and this combination has yielded higher efficiencies as well in the extended region of stable operation.


Sign in / Sign up

Export Citation Format

Share Document