scholarly journals Chemometrics-Assisted Monitoring in Raman Spectroscopy for the Biodegradation Process of an Aqueous Polyfluoroalkyl Ether from a Fire-Fighting Foam in an Environmental Matrix

Author(s):  
Mario Marchetti ◽  
Marc Offroy ◽  
Ferroudja Abdat ◽  
Philippe Branchu ◽  
Patrice Bourson ◽  
...  

Surfactants based on polyfluoroalky ethers are commonly used in fire-fighting foams on airport platforms, including for training sessions. Because of their persistence into the environment, their toxicity and their bioaccumulation, abnormal amounts can be found in ground and surface water following operations of airport platforms. As many other anthropogenic organic compounds, some concerns raised about their biodegradation. That is why the OECD 301 F protocol was implemented to appreciate the oxygen consumption during the biodegradation of a commercial fire-fighting foam. However, a Raman spectroscopic monitoring of the process was also attached to this experimental procedure to evaluate to what extent a polyfluoroalkyl ether disappeared from the environmental matrix. The relevance of our approach is to use chemometrics, including the Principal Component Analysis (PCA) and the Partial Least Square (PLS), in order to monitor the kinetics of the biodegradation reaction of one fire-fighting foam, Tridol S3B, containing a polyfluoroalkyl ether. This study provided a better appreciation of the partial biodegradation of some polyfluoroalkyl ethers by coupling Raman spectroscopy and chemometrics. This will ultimately facilitates the design of a future purification and remediation devices for the airport platforms.

Environments ◽  
2020 ◽  
Vol 7 (1) ◽  
pp. 4 ◽  
Author(s):  
Mario Marchetti ◽  
Marc Offroy ◽  
Ferroudja Abdat ◽  
Philippe Branchu ◽  
Patrice Bourson ◽  
...  

Surfactants based on polyfluoroalkyl ethers are commonly used in fire-fighting foams on airport platforms, including for training sessions. Because of their persistence into the environment, their toxicity and their bioaccumulation, abnormal amounts can be found in ground and surface water following the operations of airport platforms. As with many other anthropogenic, organic compounds, some concerns are raised about their biodegradation. That is why the Organization for Economic Co-operation and Development (OECD) 301 F protocol was implemented to monitor the oxygen consumption during the biodegradation of a commercial fire-fighting foam. However, a Raman spectroscopic monitoring of the process was also attached to this experimental procedure to evaluate to what extent a polyfluoroalkyl ether disappeared from the environmental matrix. Our approach relies on the use of chemometrics, such as Principal Component Analysis (PCA) and Partial Least Squares (PLS), in order to monitor the kinetics of the biodegradation reaction of one fire-fighting foam, Tridol S3B, containing a polyfluoroalkyl ether. This study provided a better appreciation of the partial biodegradation of some polyfluoroalkyl ethers by coupling Raman spectroscopy and chemometrics. This will ultimately facilitate the design of future purification and remediation devices for airport platforms.


2002 ◽  
Vol 56 (1) ◽  
pp. 117-124 ◽  
Author(s):  
H. Schulz ◽  
B. Schrader ◽  
R. Quilitzsch ◽  
B. Steuer

The essential oils of various commercial citrus species were studied by ATR/FT-IR as well as NIR-FT Raman spectroscopy. Some of the most relevant monoterpene components occurring in the oil, such as limonene and γ-terpinene, show characteristic key bands in the IR and Raman spectra, which are useful for making a quantitative distinction between different oil types. Applying principal component analysis (PCA) to the spectral data, the individual citrus products are located, in most cases, as separated clusters in a 3-dimensional factor space. Cross-validation statistics showed that a partial least-square (PLS) algorithm was able to produce high quality predictions of the relative oil composition as well as general quality parameters. Both complementary spectroscopic techniques described in this study have the potential to replace existing analytical procedures because they are capable of faster quality control measurements and they allow on-line analyses during distillation or extraction processes to be performed.


2021 ◽  
Vol 11 (11) ◽  
pp. 1165
Author(s):  
Mukta Sharma ◽  
Ming-Jer Jeng ◽  
Chi-Kuang Young ◽  
Shiang-Fu Huang ◽  
Liann-Be Chang

The aim of this study was to investigate the clinical potential of Raman spectroscopy (RS) in detecting oral squamous cell carcinoma (OSCC) in tumor and healthy tissues in surgical resection specimens during surgery. Raman experiments were performed on cryopreserved specimens from patients with OSCC. Univariate and multivariate analysis was performed based on the fingerprint region (700–1800 cm−1) of the Raman spectra. One hundred thirty-one ex-vivo Raman experiments were performed on 131 surgical resection specimens obtained from 67 patients. The principal component analysis (PCA) and partial least square (PLS) methods with linear discriminant analysis (LDA) were applied on an independent validation dataset. Both models were able to differentiate between the tissue types, but PLS–LDA showed 100% accuracy, sensitivity, and specificity. In this study, Raman measurements of fresh resection tissue specimens demonstrated that OSCC had significantly higher nucleic acid, protein, and several amino acid contents than adjacent healthy tissues. The specific spectral information obtained in this study can be used to develop an in vivo Raman spectroscopic method for the tumor-free resection boundary during surgery.


2019 ◽  
Vol 8 (1) ◽  
Author(s):  
Khairunnisa Khairunnisa ◽  
Rizka Pitri ◽  
Victor P Butar-Butar ◽  
Agus M Soleh

This research used CFSRv2 data as output data general circulation model. CFSRv2 involves some variables data with high correlation, so in this research is using principal component regression (PCR) and partial least square (PLS) to solve the multicollinearity occurring in CFSRv2 data. This research aims to determine the best model between PCR and PLS to estimate rainfall at Bandung geophysical station, Bogor climatology station, Citeko meteorological station, and Jatiwangi meteorological station by comparing RMSEP value and correlation value. Size used was 3×3, 4×4, 5×5, 6×6, 7×7, 8×8, 9×9, and 11×11 that was located between (-40) N - (-90) S and 1050 E -1100 E with a grid size of 0.5×0.5 The PLS model was the best model used in stastistical downscaling in this research than PCR model because of the PLS model obtained the lower RMSEP value and the higher correlation value. The best domain and RMSEP value for Bandung geophysical station, Bogor climatology station, Citeko meteorological station, and Jatiwangi meteorological station is 9 × 9 with 100.06, 6 × 6 with 194.3, 8 × 8 with 117.6, and 6 × 6 with 108.2, respectively.


Molecules ◽  
2021 ◽  
Vol 26 (6) ◽  
pp. 1546
Author(s):  
Ioanna Dagla ◽  
Anthony Tsarbopoulos ◽  
Evagelos Gikas

Colistimethate sodium (CMS) is widely administrated for the treatment of life-threatening infections caused by multidrug-resistant Gram-negative bacteria. Until now, the quality control of CMS formulations has been based on microbiological assays. Herein, an ultra-high-performance liquid chromatography coupled to ultraviolet detector methodology was developed for the quantitation of CMS in injectable formulations. The design of experiments was performed for the optimization of the chromatographic parameters. The chromatographic separation was achieved using a Waters Acquity BEH C8 column employing gradient elution with a mobile phase consisting of (A) 0.001 M aq. ammonium formate and (B) methanol/acetonitrile 79/21 (v/v). CMS compounds were detected at 214 nm. In all, 23 univariate linear-regression models were constructed to measure CMS compounds separately, and one partial least-square regression (PLSr) model constructed to assess the total CMS amount in formulations. The method was validated over the range 100–220 μg mL−1. The developed methodology was employed to analyze several batches of CMS injectable formulations that were also compared against a reference batch employing a Principal Component Analysis, similarity and distance measures, heatmaps and the structural similarity index. The methodology was based on freely available software in order to be readily available for the pharmaceutical industry.


2021 ◽  
Vol 22 (1) ◽  
Author(s):  
Mika Jönsson ◽  
Björn Gerdle ◽  
Bijar Ghafouri ◽  
Emmanuel Bäckryd

Abstract Background Neuropathic pain (NeuP) is a complex, debilitating condition of the somatosensory system, where dysregulation between pro- and anti-inflammatory cytokines and chemokines are believed to play a pivotal role. As of date, there is no ubiquitously accepted diagnostic test for NeuP and current therapeutic interventions are lacking in efficacy. The aim of this study was to investigate the ability of three biofluids - saliva, plasma, and cerebrospinal fluid (CSF), to discriminate an inflammatory profile at a central, systemic, and peripheral level in NeuP patients compared to healthy controls. Methods The concentrations of 71 cytokines, chemokines and growth factors in saliva, plasma, and CSF samples from 13 patients with peripheral NeuP and 13 healthy controls were analyzed using a multiplex-immunoassay based on an electrochemiluminescent detection method. The NeuP patients were recruited from a clinical trial of intrathecal bolus injection of ziconotide (ClinicalTrials.gov identifier NCT01373983). Multivariate data analysis (principal component analysis and orthogonal partial least square regression) was used to identify proteins significant for group discrimination and protein correlation to pain intensity. Proteins with variable influence of projection (VIP) value higher than 1 (combined with the jack-knifed confidence intervals in the coefficients plot not including zero) were considered significant. Results We found 17 cytokines/chemokines that were significantly up- or down-regulated in NeuP patients compared to healthy controls. Of these 17 proteins, 8 were from saliva, 7 from plasma, and 2 from CSF samples. The correlation analysis showed that the most important proteins that correlated to pain intensity were found in plasma (VIP > 1). Conclusions Investigation of the inflammatory profile of NeuP showed that most of the significant proteins for group separation were found in the less invasive biofluids of saliva and plasma. Within the NeuP patient group it was also seen that proteins in plasma had the highest correlation to pain intensity. These preliminary results indicate a potential for further biomarker research in the more easily accessible biofluids of saliva and plasma for chronic peripheral neuropathic pain where a combination of YKL-40 and MIP-1α in saliva might be of special interest for future studies that also include other non-neuropathic pain states.


2021 ◽  
pp. 096703352098731
Author(s):  
Adenilton C da Silva ◽  
Lívia PD Ribeiro ◽  
Ruth MB Vidal ◽  
Wladiana O Matos ◽  
Gisele S Lopes

The use of alcohol-based hand sanitizers is recommended as one of several strategies to minimize contamination and spread of the COVID-19 disease. Current reports suggest that the virucidal potential of ethanol occurs at concentrations close to 70%. Traditional methods of verifying the ethanol concentration in such products invite potential errors due to the viscosity of chemical components or may be prohibitively expensive to undertake in large demand. Near infrared (NIR) spectroscopy and chemometrics have already been used for the determination of ethanol in other matrices and present an alternative fast and reliable approach to quality control of alcohol-based hand sanitizers. In this study, a portable NIR spectrometer combined with classification chemometric tools, i.e., partial least square discriminant analysis (PLS–DA) and linear discriminant analysis with successive algorithm projection (SPA–LDA) were used to construct models to identify conforming and non-conforming commercial and laboratory synthesized hand sanitizer samples. Principal component analysis (PCA) was applied in an exploratory data study. Three principal components accounted for 99% of data variance and demonstrate clustering of conforming and non-conforming samples. The PLS–DA and SPA–LDA classification models presented 77 and 100% of accuracy in cross/internal validation respectively and 100% of accuracy in the classification of test samples. A total of 43% commercial samples evaluated using the PLS–DA and SPA–LDA presented ethanol content non-conforming for hand sanitizer gel. These results indicate that use of NIR spectroscopy and chemometrics is a promising strategy, yielding a method that is fast, portable, and reliable for discrimination of alcohol-based hand sanitizers with respect to conforming and non-conforming ethanol concentrations.


2021 ◽  
Vol 16 (1) ◽  
Author(s):  
Huan-Hua Xu ◽  
Zhen-Hong Jiang ◽  
Cong-Shu Huang ◽  
Yu-Ting Sun ◽  
Long-Long Xu ◽  
...  

Abstract Background OPD and OPD' are the two main active components of Ophiopogon japonicas in Shenmai injection (SMI). Being isomers of each other, they are supposed to have similar pharmacological activities, but the actual situation is complicated. The difference of hemolytic behavior between OPD and OPD' in vivo and in vitro was discovered and reported by our group for the first time. In vitro, only OPD' showed hemolysis reaction, while in vivo, both OPD and OPD' caused hemolysis. In vitro, the primary cause of hemolysis has been confirmed to be related to the difference between physical and chemical properties of OPD and OPD'. In vivo, although there is a possible explanation for this phenomenon, the one is that OPD is bio-transformed into OPD' or its analogues in vivo, the other one is that both OPD and OPD' were metabolized into more activated forms for hemolysis. However, the mechanism of hemolysis in vivo is still unclear, especially the existing literature are still difficult to explain why OPD shows the inconsistent hemolysis behavior in vivo and in vitro. Therefore, the study of hemolysis of OPD and OPD' in vivo is of great practical significance in response to the increase of adverse events of SMI. Methods Aiming at the hemolysis in vivo, this manuscript adopted untargeted metabolomics and lipidomics technology to preliminarily explore the changes of plasma metabolites and lipids of OPD- and OPD'-treated rats. Metabolomics and lipidomics analyses were performed on ultra-high performance liquid chromatography (UPLC) system tandem with different mass spectrometers (MS) and different columns respectively. Multivariate statistical approaches such as principal component analysis (PCA) and orthogonal partial least square-discriminant analysis (OPLS-DA) were applied to screen the differential metabolites and lipids. Results Both OPD and OPD' groups experienced hemolysis, Changes in endogenous differential metabolites and differential lipids, enrichment of differential metabolic pathways, and correlation analysis of differential metabolites and lipids all indicated that the causes of hemolysis by OPD and OPD' were closely related to the interference of phospholipid metabolism. Conclusions This study provided a comprehensive description of metabolomics and lipidomics changes between OPD- and OPD'-treated rats, it would add to the knowledge base of the field, which also provided scientific guidance for the subsequent mechanism research. However, the underlying mechanism require further research.


Sign in / Sign up

Export Citation Format

Share Document