scholarly journals Loosening and revision rates after total shoulder arthroplasty: a systematic review of cemented all-polyethylene glenoid and three modern designs of metal-backed glenoid

2020 ◽  
Author(s):  
Dong Min Kim ◽  
Mohammed Aldeghaither ◽  
Fahad Alabdullatif ◽  
Myung Jin Shin ◽  
Erica Kholinne ◽  
...  

Abstract Background: Several modern designs of metal-backed glenoids (MBG) have been devised to overcome flaws such as loosening and a high failure rate. This review aimed to compare rates of complications and revision surgeries between cemented polyethylene glenoid (PEG) and three examples of modern MBG designs.Methods: Literature search was carried out using PubMed, Cochrane Library, EMBASE, and Google Scholar using MeSH terms and natural keywords. A total of 1186 articles were screened. We descriptively analyzed numerical data between the groups and statistically analyzed the categorical data, such as the presence of radiolucent line, loosening, and revision surgery (failure). Articles were divided into three groups based on follow-up duration: < 36-month, 36–72-month, and > 72-month subgroups.Results: This study included 35 articles (3769 shoulders); 25 on cemented PEG and ten on the modern MBG. Mean age was 66.4 (21–93) and 66.5 years (31–88). The mean duration of follow-up was 73.1 (12–211) and 56.1 months (24–100). Overall, the rate of the radiolucent line was 354/1302 (27%) and 47/282 (17%), the loosening rate was 465/3185 (15 %) and 22/449 (5%), and the failure rate was 189/3316 (6%) and 11/457 (2%), for PEG and MBG, respectively. The results of < 36-month and 36–72-month subgroups showed lower rates of radiolucency and loosening in the cemented PEG group, but there was no significant difference in failure rate (P=0.754 and 0.829, respectively). In the > 72-month subgroup, MBG was better in terms of loosening (P <0.001) and failure rates (P = 0.006).Conclusions: The modern MBG component, especially TM glenoid, seems to be a promising alternative to cemented PEGs, based on subgroup revision rates according to the follow-up duration and overall results of ROM and clinical scores. All polyethylene glenoids tend to increase loosening and failure over time. Three modern MBG designs seem to have no difference in failure, at least in the < 36-month and 36–72-month subgroups compared to the cemented PEG. More long-term follow-up studies on modern MBG should be ultimately conducted.

2019 ◽  
Author(s):  
Dong Min Kim ◽  
Mohammed Aldeghaither ◽  
Fahad Alabdullatif ◽  
Myung Jin Shin ◽  
Erica Kholinne ◽  
...  

Abstract Background: Modern designs of metal-backed glenoids (MBG) have been devised to overcome flaws such as loosening and a high failure rate.This review aimed to compare rates of complications and revision surgeries between the modern metal-backed glenoid (MBG) and the cemented polyethylene glenoid (PEG).Methods: Literature search was carried out using PubMed, Cochrane Library, EMBASE, and Google Scholar using MeSH terms and natural keywords. A total of 1186 articles were screened. We descriptively analyzed numerical data between the groups and statistically analyzed the categorical data, such as the presence of radiolucent line, loosening, and revision surgery (failure). Articles were divided into 3 groups based on follow-up duration: short-term < 36 months, midterm 36–72 months, and long-term > 72 months.Results: This study included 35 articles (3769 shoulders); 25 on cemented PEG and ten on the modern MBG. Mean age was 66.4 (21–93) and 66.5 years (31–88). The mean duration of follow-up was 73.1 (12–211) and 56.1 months (24–100). Overall, the rate of the radiolucent line was 354/1302 (27%) and 47/282 (17%), the loosening rate was 465/3185 (15 %) and 22/449 (5%), and the failure rate was 189/3316 (6%) and 11/457 (2%), for PEG and MBG, respectively. The results of short- and mid-term FU studies showed lower rates of radiolucency and loosening in the cemented PEG group, but there was no significant difference in failure rate (P=0.754 and 0.829, respectively). In long-term FU, MBG was better in terms of loosening (P <0.001) and failure rates (P = 0.006).Conclusions: The modern MBG component, especially TM glenoid, seems to be a promising alternative to cemented PEGs, based on subgroup revision rates according to the follow-up duration and overall results of ROM and clinical scores. All polyethylene glenoids tend to increase loosening and failure over time. The modern MBG seems to have no difference in failure, at least in the short- and mid-term compared to the cemented PEG. More long-term follow-up studies on modern MBG should be ultimately conducted.


2020 ◽  
Author(s):  
Dong Min Kim ◽  
Mohammed Aldeghaither ◽  
Fahad Alabdullatif ◽  
Myung Jin Shin ◽  
Erica Kholinne ◽  
...  

Abstract Background: Modern designs of metal-backed glenoids (MBG) have been devised to overcome flaws such as loosening and a high failure rate. This review aimed to compare rates of complications and revision surgeries between the modern metal-backed glenoid (MBG) and the cemented polyethylene glenoid (PEG).Methods: Literature search was carried out using PubMed, Cochrane Library, EMBASE, and Google Scholar using MeSH terms and natural keywords. A total of 1186 articles were screened. We descriptively analyzed numerical data between the groups and statistically analyzed the categorical data, such as the presence of radiolucent line, loosening, and revision surgery (failure). Articles were divided into 3 groups based on follow-up duration: short-term < 36 months, midterm 36–72 months, and long-term > 72 months.Results: This study included 35 articles (3769 shoulders); 25 on cemented PEG and ten on the modern MBG. Mean age was 66.4 (21–93) and 66.5 years (31–88). The mean duration of follow-up was 73.1 (12–211) and 56.1 months (24–100). Overall, the rate of the radiolucent line was 354/1302 (27%) and 47/282 (17%), the loosening rate was 465/3185 (15 %) and 22/449 (5%), and the failure rate was 189/3316 (6%) and 11/457 (2%), for PEG and MBG, respectively. The results of short- and mid-term FU studies showed lower rates of radiolucency and loosening in the cemented PEG group, but there was no significant difference in failure rate (P=0.754 and 0.829, respectively). In long-term FU, MBG was better in terms of loosening (P <0.001) and failure rates (P = 0.006).Conclusions: The modern MBG component, especially TM glenoid, seems to be a promising alternative to cemented PEGs, based on subgroup revision rates according to the follow-up duration and overall results of ROM and clinical scores. All polyethylene glenoids tend to increase loosening and failure over time. The modern MBG seems to have no difference in failure, at least in the short- and mid-term compared to the cemented PEG. More long-term follow-up studies on modern MBG should be ultimately conducted.


2022 ◽  
Vol 104-B (1) ◽  
pp. 83-90
Author(s):  
Timothy J. Batten ◽  
Sian Gallacher ◽  
Jonathan P. Evans ◽  
Richard J. Harding ◽  
Jeffrey Kitson ◽  
...  

Aims The use and variety of stemless humeral components in anatomical total shoulder arthroplasty (TSA) have proliferated since their advent in 2004. Early outcomes are reassuring but independent mid-term results are scarce. This independent study reports a consecutive series of 143 Eclipse stemless shoulder prostheses with a minimum five-year (5 to 10) follow-up. Methods Outcomes of 143 procedures undertaken for all indications in 131 patients were reviewed, with subset analysis of those for osteoarthritis (OA) (n = 99). The primary outcome was the Oxford Shoulder Score (OSS) at a minimum of five years. Secondary outcomes were ranges of motion and radiological analysis of humeral radiolucency, rotator cuff failure, and glenoid loosening. Results Mean OSS at mean follow-up of 6.67 years (5.0 to 10.74) was 40.12 (9 to 48), with no statistically significant difference between those implanted for a non-OA indication and those for OA (p = 0.056) or time-dependent deterioration between two years and five years (p = 0.206). Ranges of motion significantly improved compared with preoperative findings and were maintained between two and five years with a mean external rotation of 38° (SD 18.1, 0 to 100) and forward elevation of 152° (SD 29.9, 90 to 180). Of those components with radiographs suitable for analysis (n = 83), 23 (28%) were found to have a least one humeral radiolucent line, which were predominantly incomplete, less than 2 mm, and in a single anatomical zone. No humeral components were loose. A radiolucent line was present around 22 (15%) of glenoid components, and 15 (10%) of components had failed. Rotator cuff failure was found in 21 (15%) components. The mean time to either glenoid or rotator cuff failure was greater than three years following implantation. Survivorship was 96.4% (95% CI 91.6 to 98.5, number at risk 128) at five years, and 94.3% (95% CI 88.2 to 97.3, number at risk 76) at seven years, both of which compare favourably with best results taken from available registries. Conclusion Functional and radiological outcomes of the Eclipse stemless TSA are excellent, with no loose humeral components at minimum five-year follow-up. The presence of radiolucent lines is of interest and requires long-term observation but does not impact on the clinical results. Of the eight revisions required, this was predominantly for glenoid and rotator cuff failure. Cite this article: Bone Joint J 2022;104-B(1):83–90.


2021 ◽  
Vol 10 (7) ◽  
pp. 1336
Author(s):  
Toshifumi Takahashi ◽  
Shinya Somiya ◽  
Katsuhiro Ito ◽  
Toru Kanno ◽  
Yoshihito Higashi ◽  
...  

Introduction: Cystine stone development is relatively uncommon among patients with urolithiasis, and most studies have reported only on small sample sizes and short follow-up periods. We evaluated clinical courses and treatment outcomes of patients with cystine stones with long-term follow-up at our center. Methods: We retrospectively analyzed 22 patients diagnosed with cystine stones between January 1989 and May 2019. Results: The median follow-up was 160 (range 6–340) months, and the median patient age at diagnosis was 46 (range 12–82) years. All patients underwent surgical interventions at the first visit (4 extracorporeal shockwave lithotripsy, 5 ureteroscopy, and 13 percutaneous nephrolithotripsy). The median number of stone events and surgical interventions per year was 0.45 (range 0–2.6) and 0.19 (range 0–1.3) after initial surgical intervention. The median time to stone events and surgical intervention was 2 years and 3.25 years, respectively. There was a significant difference in time to stone events and second surgical intervention when patients were divided at 50 years of age at diagnosis (p = 0.02, 0.04, respectively). Conclusions: Only age at a diagnosis under 50 was significantly associated with recurrent stone events and intervention. Adequate follow-up and treatment are needed to manage patients with cystine stones safely.


1991 ◽  
Vol 9 (5) ◽  
pp. 736-740 ◽  
Author(s):  
L E Spitler

We conducted a long-term follow-up (median, 10.5 years) of patients included in a randomized trial of levamisole versus placebo as surgical adjuvant therapy in 203 patients with malignant melanoma. Of the patients randomized, 104 received levamisole, and 99 received placebo. The results show that there is no difference between the treatment and control groups with regard to any of the three end points analyzed. These included disease-free interval, time to appearance of visceral metastasis, and survival. Moreover, there was no significant difference between the treatment and control groups after adjusting for age, sex, or stage of disease.


2019 ◽  
Vol 2019 ◽  
pp. 1-6 ◽  
Author(s):  
Joanna Wojtasik-Bakalarz ◽  
Zoltan Ruzsa ◽  
Tomasz Rakowski ◽  
Andreas Nyerges ◽  
Krzysztof Bartuś ◽  
...  

The most relevant comorbidities in patients with peripheral artery disease (PAD) are coronary artery disease (CAD) and diabetes mellitus (DM). However, data of long-term follow-up of patients with chronic total occlusion (CTO) are scarce. The aim of the study was to assess the impact of CAD and DM on long-term follow-up patients after superficial femoral artery (SFA) CTO retrograde recanalization. In this study, eighty-six patients with PAD with diagnosed CTO in the femoropopliteal region and at least one unsuccessful attempt of antegrade recanalization were enrolled in 2 clinical centers. Mean time of follow-up in all patients was 47.5 months (±40 months). Patients were divided into two groups depending on the presence of CAD (CAD group: n=45 vs. non-CAD group: n=41) and DM (DM group: n=50 vs. non-DM group: n=36). In long-term follow-up, major adverse peripheral events (MAPE) occurred in 66.6% of patients with CAD vs. 36.5% of patients without CAD and in 50% of patients with DM vs. 55% of non-DM subjects. There were no statistical differences in peripheral endpoints in both groups. However, there was a statistically significant difference in all-cause mortality: in the DM group, there were 6 deaths (12%) (P value = 0.038). To conclude, patients after retrograde recanalization, with coexisting CTO and DM, are at higher risk of death in long-term follow-up.


2020 ◽  
Vol 72 (1) ◽  
Author(s):  
Mohammad Abdallah Eltahlawi ◽  
Abdel-Aziz Fouad Abdel-Aziz ◽  
Abdel-Salam Sherif ◽  
Khalid Abdel-Azeem Shokry ◽  
Islam Elsayed Shehata

Abstract Background We hypothesized that 1st generation everolimus-eluting bioresorbable vascular scaffold (BVS) stent associated with less complication and less restenosis rate than everolimus-eluting stent (EES) in chronic total occlusion (CTO) recanalization guided by intracoronary imaging. Therefore, we aimed to assess the safety and performance of BVS stent in CTO revascularization in comparison to EES guided by intracoronary imaging. Our prospective comparative cross-sectional study was conducted on 60 CTO patients divided into two groups according to type of stent revascularization: group I (EES group): 40 (66.7%) patients and group II (BVS group): 20 (33.3%) patients. All patients were subjected to history taking, electrocardiogram (ECG), echocardiography, laboratory investigation, stress thallium study to assess viability before revascularization. Revascularization of viable CTO lesion guided by intracoronary imaging using optical coherence tomography (OCT). Then, long-term follow-up over 1 year clinically and by multi-slice CT coronary angiography (MSCT). Our clinical and angiographic endpoints were to detect any clinical or angiographic complications during the follow-up period. Results At 6 months angiographic follow-up, BVS group had not inferior angiographic parameters but without statistically significant difference (p = 0.566). At 12 months follow-up, there was no difference at end points between the two groups (p = 0.476). No differences were found at angiographic or clinical follow-up between BVS and EES. Conclusion This study shows that 1st generation everolimus-eluting BVS is non-inferior to EES for CTO revascularization. Further studies are needed to clearly state which new smaller footprint BVS, faster reabsorption, magnesium-based less thrombogenicity, and advanced mechanical properties is under development. We cannot dismiss the efficacy and safety of new BVS technology. Trial registration ZU-IRB#2498/3-12-2016 Registered 3 December 2016, email: [email protected]


2017 ◽  
Vol 45 (9) ◽  
pp. 2098-2104 ◽  
Author(s):  
Jorge Chahla ◽  
Chase S. Dean ◽  
Lauren M. Matheny ◽  
Justin J. Mitchell ◽  
Mark E. Cinque ◽  
...  

Background: Limited evidence exists for meniscal repair outcomes in a multiligament reconstruction setting. Purpose/Hypothesis: The purpose of this study was to assess outcomes and failure rates of meniscal repair in patients who underwent multiligament reconstruction compared with patients who underwent multiligament reconstruction but lacked meniscal tears. The authors hypothesized that the outcomes of meniscal repair associated with concomitant multiligament reconstruction would significantly improve from preoperatively to postoperatively at a minimum of 2 years after the index surgery. Secondarily, they hypothesized that this cohort would demonstrate similar outcomes and failure rates compared with the cohort that did not have meniscal lesions at the time of multiligament reconstruction. Study Design: Cohort study; Level of evidence, 3. Methods: Inclusion criteria for the study included radiographically confirmed skeletally mature patients of at least 16 years of age who underwent multiligamentous reconstruction of the knee without previous ipsilateral osteotomy, intra-articular infections, or intra-articular fractures. Patients were included in the experimental group if they underwent inside-out meniscal suture repair with concurrent multiligament reconstruction. Those included in the control group (multiligament reconstruction without a meniscal tear) underwent multiligament reconstruction but did not undergo any type of meniscal surgery. Lysholm, Western Ontario and McMaster Universities Osteoarthritis Index, Short Form–12 physical component summary and mental component summary, Tegner activity scale, and patient satisfaction scores were recorded preoperatively and postoperatively. The failure of meniscal repair was defined as a retear of the meniscus that was confirmed arthroscopically. Results: There were 43 patients (16 female, 27 male) in the meniscal repair group and 62 patients (25 female, 37 male) in the control group. Follow-up was obtained in 93% of patients with a mean of 3.0 years (range, 2.0-4.7 years). There was a significant improvement between all preoperative and postoperative outcome scores ( P < .05) for both groups. The meniscal repair group had significantly lower preoperative Lysholm and Tegner scores ( P = .009 and P = .02, respectively). There were no significant differences between any other outcome scores preoperatively. The failure rate of the meniscal repair group was 2.7%, consisting of 1 symptomatic meniscal retear. There was no significant difference in any postoperative outcome score at a minimum 2-year follow-up between the 2 groups. Conclusion: Good to excellent patient-reported outcomes were reported for both groups with no significant differences in outcomes between the cohorts. Additionally, the failure rate for inside-out meniscal repair with concomitant multiligament reconstruction was low, regardless of meniscus laterality and tear characteristics. The use of multiple vertical mattress sutures and the biological augmentation resulting from intra-articular cruciate ligament reconstruction tunnel reaming may be partially responsible for the stability of the meniscal repair construct and thereby contribute to the overall improved outcomes and the low failure rate of meniscal repair, despite lower preoperative Lysholm and Tegner scores in the meniscal repair group.


2011 ◽  
Vol 9 (1-2) ◽  
pp. 0-0
Author(s):  
Tomas Abalikšta ◽  
Gintautas Brimas ◽  
Kęstutis Strupas

Tomas Abalikšta, Gintautas Brimas, Kęstutis Strupas Vilniaus universiteto Medicinos fakultetas, M. K. Čiurlionio g. 21, LT-03101 VilniusVilniaus universiteto ligoninės Santariškių klinikų Pilvo chirurgijos centras,Santariškių g. 2, LT-08661 VilniusEl. paštas: [email protected] Darbo tikslas: Remiantis literatūros duomenimis palyginti skirtingas skrandžio apjuosimo reguliuojamas juostas, naudojamas chirurginiam nutukimo gydymui. Tyriamoji medžiaga ir metodai: Publikacijų paieška atlikta elektroninėse MEDLINE, Current Contents ir Cochrane Library duomenų bazėse. Apžvelgtos visos skrandį apjuosiančių reguliuojamų juostų lyginamųjų studijų publikacijos, paskelbtos iki 2010 m. sausio 1 d. Rezultatai: Atlikus literatūros šaltinių paiešką rasta 10 publikacijų, lyginančių skirtingas skrandį apjuosiančias reguliuojamas juostas. Išsamiai atlikta viena studija: perspektyvi, atsitiktinių imčių, jos tiriamųjų skaičius didelis ir stebėjimo laikotarpis ilgas, įvertinti visi gydymo rezultatai. Statistiškai reikšmingo skirtumo tarp SAGB ir LAP-BAND juostų šioje studijoje nerasta. Kitos lyginamosios juostų studijos turi trūkumų: keturios buvo ne atsitiktinių imčių (dvi iš jų retrospektyvios), trijose tiriamųjų imtis maža, visų stebėjimo laikas trumpas. Vienoje iš šių studijų nustatytas kūno masės kritimo skirtumas tarp grupių: LAP-BAND grupėje pradinė viršnorminė kūno masė sumažėjo 41,7 %, Heliogast – 28,3 %. Mechaninių juostų komplikacijų dažnis skyrėsi vienoje studijoje: LAP-BAND – 7 %, SAGB – 1 %. Skirtumas tarp „mažo skrandžio“ išsiplėtimo arba juostos nuslinkimo dažnio rastas trijose studijose (MiniMizer Extra – 0 % ir LAP-BAND – 10,8 %; SAGB – 2,4 % ir LAP-BAND – 27,6 %; SAGB – 2 % ir LAP-BAND – 23 %). Skirtumo tarp gretutinių ligų ir gyvenimo kokybės pokyčio, hospitalizacijos trukmės, juostos reguliavimų skaičiaus/dažnio, juostos penetracijos/migracijos į skrandį bei infekcinių komplikacijų dažnio nerasta. Išvados: Tik viena studija atlikta laikantis šiuolaikinių įrodymais pagrįstos medicinos keliamų reikalavimų, skirtumo tarp lygintų juostų nerasta. Reikalingos perspektyvios, atsitiktinių imčių ilgalaikės (>5 metų) lyginamosios studijos, vertinančios juostų konstrukcijos ar formos skirtumų įtaką gydymo efektyvumui ar komplikacijoms. Reikšminiai žodžiai: nutukimas, bariatrinė chirurgija, skrandžio apjuosimo reguliuojama juosta operacija. Adjustable gastric bands: review of comparative studies Tomas Abalikšta, Gintautas Brimas, Kęstutis Strupas Vilnius University Medical Faculty, M. K. Čiurlionio Str. 21, LT-03101 Vilnius, LithuaniaVilnius University Hospital Santariškių Klinikos Centre of Abdominal Surgery,Santariškių Str. 2, LT-08661 Vilnius, LithuaniaEl. paštas: [email protected] Objective: The objective of this review is to compare different adjustable gastric bands according to the data of comparative studies. Materials and Methods: A search of articles published in any language before January 2010 was carried out through the MEDLINE, Current Contents and Cochrane Library electronic databases. All articles about comparative studies of different adjustable gastric bands were eligible for review. All possible data were extracted from accepted studies and reviewed. Results: Ten comparative studies of different adjustable gastric bands were accepted. Only one comparative study of the bands was accomplished properly. It was a prospective randomised study type with a large number of patients and a long follow-up period with all possible results evaluated. No statistically significant difference between SAGB and LAP-BAND gastric bands was found in this study. The other band studies had shortcomings: four studies were non-randomised (two of them retrospective), a small number of patients in three studies, and a too short follow-up period in all studies. The difference in weight loss was stated in one of these studies: 41.7% of initial excess weight loss in the LAP-BAND group and 28.3% in the Heliogast group. Band leakage frequency was different in one study: LAP-BAND – 7%, SAGB – 1%. A difference between pouch dilatation or band slippage frequency was found in three studies (MiniMizer Extra – 0% and LAP-BAND – 10.8%; SAGB – 2.4% and LAP-BAND – 27.6%; SAGB – 2% and LAP-BAND – 23%). There was no difference between the resolution of comorbidities, improvement of the quality of life, hospital stay, band adjustment frequency, band migration or band infection rate. Conclusion: Only one accepted study was accomplished properly. There was no difference between compared adjustable gastric bands in this study. Prospective randomised long-term (more than 5 years) comparative studies are needed for a proper evaluation of band construction or shape influence on weight loss and complications. Keywords: obesity, bariatric surgery, adjustable gastric banding.


2021 ◽  
Vol 12 ◽  
Author(s):  
Mohit Agrawal ◽  
Kanwaljeet Garg ◽  
Raghu Samala ◽  
Roopa Rajan ◽  
Vikas Naik ◽  
...  

Background: Magnetic resonance guided focused ultrasound (MRgFUS) is a relatively novel technique to treat essential tremor (ET). The objective of this review was to analyze the efficacy and the safety profile of MRgFUS for ET.Methods: A systematic literature review was done. The post procedure changes in the Clinical Rating Scale for Tremor (CRST) score, hand score, disability and quality of life scores were analyzed.Results: We found 29 studies evaluating 617 patients. DTI based targeting was utilized in six cohorts. A significant difference was observed in the pooled standard mean difference between the pre and postoperative total CRST score (p-value &lt; 0.001 and 0.0002), hand score (p-value 0.03 and 0.02); and the disability at 12 months (p-value 0.01). Head pain and dizziness were the most in procedure complications. The immediate pooled proportion of ataxia was 50%, while it was 20% for sensory complications, which, respectively, declined to 31 and 13% on long term follow up. A significant reduction (p = 0.03) in immediate ataxia related complications was seen with DTI targeting.Conclusion: MRgFUS for ET seems to be an effective procedure for relieving unilateral tremor. Use of DTI based targeting revealed a significant reduction in post procedure ataxia related complications as compared to traditional targeting techniques. Analysis of other complications further revealed a decreasing trend on follow up.


Sign in / Sign up

Export Citation Format

Share Document