scholarly journals HYPOTHESIS OF RFMRA DEVELOPMENT – THE RECEPTOR-FOCUSED MAGNETIC AND RESONANT ANESTHESIA

2016 ◽  
Vol 5 ◽  
pp. 44-49
Author(s):  
Maxim Golyanishchev

This article is described the hypothesis of the solution how to create the "ideal anesthesia". Theoretical justification of the innovative technique of the Receptor-focused Magnetic Resonance anesthesia is offered. It should be use the "ideal anesthetic" as which the electromagnetic model of a medicinal preparation for anesthesia acts. Stages of carrying out the offered type of anesthesia have offered. For the practical application of the proposed idea it would be implemented a number of innovations. First, it includes technologies of a magnetic and resonant tomography of high resolution (less than 100 microns). At the second, it would be technologies of creation electromagnetic models of the existing medical preparations. Than it would be on-line technologies of formation the 3D base of addresses of receptors for anesthesia of organism of a particular person. In addition, technologies of a triggering the cascade of biochemical reactions is proposed, by the modeling of pharmacodynamics electromagnetic models of a medicinal preparation. Such type of anesthesia will allow to avoid side effects of medical preparations at stages of an absorption, distribution, removal that are caused by the mass of drug and, in addition, respectively, to reach therapeutic effect only by means of electromagnetic model of a medicinal preparation for anesthesia.

Author(s):  
G. Van Tendeloo ◽  
J. Van Landuyt ◽  
S. Amelinckx

Polytypism has been studied for a number of years and a wide variety of stacking sequences has been detected and analysed. SiC is the prototype material in this respect; see e.g. Electron microscopy under high resolution conditions when combined with x-ray measurements is a very powerful technique to elucidate the correct stacking sequence or to study polytype transformations and deviations from the ideal stacking sequence.


Author(s):  
N. Bonnet ◽  
M. Troyon ◽  
P. Gallion

Two main problems in high resolution electron microscopy are first, the existence of gaps in the transfer function, and then the difficulty to find complex amplitude of the diffracted wawe from registered intensity. The solution of this second problem is in most cases only intended by the realization of several micrographs in different conditions (defocusing distance, illuminating angle, complementary objective apertures…) which can lead to severe problems of contamination or radiation damage for certain specimens.Fraunhofer holography can in principle solve both problems stated above (1,2). The microscope objective is strongly defocused (far-field region) so that the two diffracted beams do not interfere. The ideal transfer function after reconstruction is then unity and the twin image do not overlap on the reconstructed one.We show some applications of the method and results of preliminary tests.Possible application to the study of cavitiesSmall voids (or gas-filled bubbles) created by irradiation in crystalline materials can be observed near the Scherzer focus, but it is then difficult to extract other informations than the approximated size.


Author(s):  
Alan P. Koretsky ◽  
Afonso Costa e Silva ◽  
Yi-Jen Lin

Magnetic resonance imaging (MRI) has become established as an important imaging modality for the clinical management of disease. This is primarily due to the great tissue contrast inherent in magnetic resonance images of normal and diseased organs. Due to the wide availability of high field magnets and the ability to generate large and rapidly switched magnetic field gradients there is growing interest in applying high resolution MRI to obtain microscopic information. This symposium on MRI microscopy highlights new developments that are leading to increased resolution. The application of high resolution MRI to significant problems in developmental biology and cancer biology will illustrate the potential of these techniques.In combination with a growing interest in obtaining high resolution MRI there is also a growing interest in obtaining functional information from MRI. The great success of MRI in clinical applications is due to the inherent contrast obtained from different tissues leading to anatomical information.


Author(s):  
F. Hosokawa ◽  
Y. Kondo ◽  
T. Honda ◽  
Y. Ishida ◽  
M. Kersker

High-resolution transmission electron microscopy must attain utmost accuracy in the alignment of incident beam direction and in astigmatism correction, and that, in the shortest possible time. As a method to eliminate this troublesome work, an automatic alignment system using the Slow-Scan CCD camera has been introduced recently. In this method, diffractograms of amorphous images are calculated and analyzed to detect misalignment and astigmatism automatically. In the present study, we also examined diffractogram analysis using a personal computer and digitized TV images, and found that TV images provided enough quality for the on-line alignment procedure of high-resolution work in TEM. Fig. 1 shows a block diagram of our system. The averaged image is digitized by a TV board and is transported to a computer memory, then a diffractogram is calculated using an FFT board, and the feedback parameters which are determined by diffractogram analysis are sent to the microscope(JEM- 2010) through the RS232C interface. The on-line correction system has the following three modes.


2019 ◽  
Author(s):  
Hamilton Lee ◽  
Jenica Lumata ◽  
Michael A. Luzuriaga ◽  
Candace Benjamin ◽  
Olivia Brohlin ◽  
...  

<div><div><div><p>Many contrast agents for magnetic resonance imaging are based on gadolinium, however side effects limit their use in some patients. Organic radical contrast agents (ORCAs) are potential alternatives, but are reduced rapidly in physiological conditions and have low relaxivities as single molecule contrast agents. Herein, we use a supramolecular strategy where cucurbit[8]uril binds with nanomolar affinities to ORCAs and protects them against biological reductants to create a stable radical in vivo. We further over came the weak contrast by conjugating this complex on the surface of a self-assembled biomacromolecule derived from the tobacco mosaic virus.</p></div></div></div>


Sign in / Sign up

Export Citation Format

Share Document