Chlorine Injury and the Comparative Performance of Colisure™, Colilert™ and Coliquik™ for the Enumeration of Coliform Bacteria and E. coli in Drinking Water

1993 ◽  
Vol 27 (3-4) ◽  
pp. 261-265 ◽  
Author(s):  
Gordon A. McFeters ◽  
Barry H. Pyle ◽  
Shaun J. Gillis ◽  
Carole J. Acomb ◽  
David Ferrazza

Several factors have stimulated interest in recently developed substrate specific media for the detection of coliform bacteria in water. This study compared the performance of Colisure™ (Millipore), ColiLert™ (Environetics) and ColiQuick™ (Hach) with accepted membrane filtration and MPN methodologies for the enumeration of total coliforms and E. coli in chlorinated water. The performance of all three media was compared, in MPN configuration, with LTB/MPN (confirmed) using a variety of drinking and source water samples, both with and without chlorination. The Cochran-Mantel-Haenszel test yielded statistical correlations between results obtained with each of the three new enzyme detection media and accepted reference methods for the detection of low numbers of total coliforms. Another series of tests compared the performance of Colisure with accepted methods (LTB/MPN confirmed with BGLB and EC-MUG) in the detection of total coliforms and E. coli in sewage-spiked samples simulating contaminated drinking water, using an USEPA/AWWA test protocol. The results demonstrated that Colisure detected these indicator bacteria with greater sensitivity than the accepted methods and that this difference increased between 24 and 28 hours of incubation. The results of this study collectively support the validity of the new enzyme detection method for the detection of low levels of coliform bacteria and E. coli in source water and contaminated drinking water.

1995 ◽  
Vol 31 (5-6) ◽  
pp. 259-261
Author(s):  
G. A. McFeters ◽  
S. C. Broadaway ◽  
B. H. Pyle ◽  
M. Pickett ◽  
Y. Egozy

Studies were done to examine the comparability of ColisureTM and accepted reference methods to detect low numbers of total coliform bacteria and E. coli subjected to chlorine stress. ColisureTM is a medium designed to concurrently detect coliform bacteria and E. coli in drinking water by the specific action of β-galactosidase (total coliforms) and β-glucuronidase (E. coli). The methods used to compare the performance of various media followed a protocol established by the USEPA. Samples (31) of sewage from six different regions of the US were treated with sufficient concentrations of chlorine (1.2-2.5mg/l) to reduce viability 1-3 logs (39% average injury) and diluted with drinking water to achieve ca. 3 viable coliforms/100ml. The mean log reductions in viable bacteria, determined with various media following disinfection of the 31 samples were: mEndo = 1.87 (TC), ColisureTM = 1.55 (TC), mTec = 3.63 (E. coli) and ColisureTM = 2.01 (E. coli). When ColisureTM was compared with accepted methods to detect total coliforms in the dilute, disinfected samples, ColisureTM yielded results that were 1.6 times greater than LTB confirmed in BGLB at 28h. ColisureTM also detected 1.7 times greater levels of E. coli than LTB confirmed in EC/MUG at 28h. Sensitivity and specificity of ColisureTM were between 96 and 100% when positive and negative tests were verified. These findings indicate that ColisureTM is superior to certain accepted reference methods in the detection of chlorine-injured coliforms and E. coli under conditions that resemble contaminated drinking water.


2017 ◽  
Vol 6 (2) ◽  
pp. 411 ◽  
Author(s):  
Kirsten Ngaire Nicholson ◽  
Klaus Neumann ◽  
Carolyn Dowling ◽  
Subodh Sharma

During the 2016 pre-monsoon dry season, we undertook a systematic study of water quality, specifically fecal contamination of drinking water, in the Khumbu Valley, Sagarmatha National Park (SNP, Mt. Everest region) and SNP buffer zone, Nepal. Our goal was to quantify physical parameters (temperature, pH, conductivity and total dissolved solids), and the presence of fecal coliforms (E. coli and total coliforms) in drinking water and drinking water sources (predominately groundwater-fed springs). This data set will function as a baseline for access to potable water and further monitoring. Sample sites were selected based on primary use as a drinking water and/or drinking water source for each community. In general, there is little correlation between and physical parameters however, there are very weak correlations between total coliform data and increasing temperature, and decreasing elevation and pH. There does, however, appear to be a correlation between population (including tourist numbers) and both E. coli and total coliforms. Our study clearly indicates that the presence of bacterial indicators of fecal pollution during the dry season. Samples from the more populated, lower altitude areas had higher levels of E. coli and coliform bacteria. Importantly, drinking water that was stored in tanks or transported long distances had a much higher incidence of E. coli and total coliforms suggesting that a change in water handling practices might have an important impact on drinking water quality and population health. 


2008 ◽  
Vol 54 (6) ◽  
pp. 495-500 ◽  
Author(s):  
B. Lévesque ◽  
D. Pereg ◽  
E. Watkinson ◽  
J.S. Maguire ◽  
L. Bissonnette ◽  
...  

Bermuda residents collect rainwater from rooftops to fulfil their freshwater needs. The objective of this study was to assess the microbiological quality of drinking water in household tanks throughout Bermuda. The tanks surveyed were selected randomly from the electoral register. Governmental officers visited the selected household (n = 102) to collect water samples and administer a short questionnaire about the tank characteristics, the residents’ habits in terms of water use, and general information on the water collecting system and its maintenance. At the same time, water samples were collected for analysis and total coliforms and Escherichia coli were determined by 2 methods (membrane filtration and culture on chromogenic media, Colilert kit). Results from the 2 methods were highly correlated and showed that approximately 90% of the samples analysed were contaminated with total coliforms in concentrations exceeding 10 CFU/100 mL, and approximately 66% of samples showed contamination with E. coli. Tank cleaning in the year prior to sampling seems to protect against water contamination. If rainwater collection from roofs is the most efficient mean for providing freshwater to Bermudians, it must not be considered a source of high quality drinking water because of the high levels of microbial contamination.


2019 ◽  
Vol 65 (2) ◽  
pp. 23-32
Author(s):  
Marta Nedelkova ◽  
Angela Delova ◽  
Tanja Petreska Ivanovska ◽  
Zoran Zhivikj ◽  
Lidija Petrushevska-Tozi

The aim of this paper is to analyze the presence of Escherichia coli (E. coli) and total coliform bacteria (CB) in the drinking water of urban and rural areas of the Bitola region, as indicators for water quality and safety. All water in urban area is chlorinated, while at the same time the water in rural areas is non-chlorinated. The samples were analyzed according to the international standard method of membrane filtration MKC EN ISO 9308-1:2015. In all examined samples of drinking water in urban area, presence of E. coli and CB was not detected as a result of the disinfection of the water. On contrary, in all tested samples of the water from the rural water supply, presence of E. coli and CB was confirmed. Significant increase in coliform bacterial counts probably weather-related was found in the period from April to September. In addition, in the third quarter including July, August, and September, in many measurements, E. coli as an indicator of faecal contamination was identified in drinking water. In accordance with these findings and in order to provide safe drinking water, it is necessary to modernize the water supply for the population in rural areas, to disinfect permanently the drinking water and to apply regular laboratory controls which are a basic pre-condition. Otherwise, inappropriate management of the water systems can cause serious decrease in the quality and safety of the drinking water associated with an increased risk of appearance of the infectious diseases in people and hydric epidemic. Key words: drinking water, Escherichia coli, coliform bacteria, membrane filtration


2009 ◽  
Vol 89 (2) ◽  
pp. 285-293 ◽  
Author(s):  
S J Bach ◽  
R P Johnson ◽  
K. Stanford ◽  
T A McAllister

Bacteriophage biocontrol has potential as a means of mitigating the prevalence of Escherichia coli O157:H7 in ruminants. The efficacy of oral administration of bacteriophages for reducing fecal shedding of E. coli O157:H7 by sheep was evaluated using 20 Canadian Arcott rams (50.0 ± 3.0) housed in four rooms (n = 5) in a contained facility. The rams had ad libitum access to drinking water and a pelleted barley-based total mixed ration, delivered once daily. Experimental treatments consisted of administration of E. coli O157:H7 (O157), E. coli O157:H7+bacteriophages (O157+phage), bacteriophages (phage), and control (CON). Oral inoculation of the rams with 109 CFU of a mixture of four nalidixic acid-resistant strains of E. coli O157:H7 was performed on day 0. A mixture of 1010 PFU of bacteriophages P5, P8 and P11 was administered on days -2, -1, 0, 6 and 7. Fecal samples collected on 14 occasions over 21 d were analyzed for E. coli O157:H7, total E. coli, total coliforms and bacteriophages. Sheep in treatment O157+phage shed fewer (P < 0.05) E. coli O157:H7 than did sheep in treatment O157. Populations of total coliforms and total E. coli were similar (P < 0.05) among treatments, implying that bacteriophage lysis of non-target E. coli and coliform bacteria in the gastrointestinal tract did not occur. Bacteriophage numbers declined rapidly over 21 d, which likely reduced the chance of collision between bacteria and bacteriophage. Oral administration of bacteriophages reduced shedding of E. coli O157:H7 by sheep, but a delivery system that would protect bacteriophages during passage through the intestine may increase the effectiveness of this strategy as well as allow phage to be administered in the feed.Key words: Escherichia coli O157:H7, bacteriophage, sheep, environment, coliforms


2007 ◽  
Vol 53 (6) ◽  
pp. 688-694 ◽  
Author(s):  
Annie Locas ◽  
Christine Barthe ◽  
Benoit Barbeau ◽  
Annie Carrière ◽  
Pierre Payment

A 1 year study was undertaken on groundwater that was a source of drinking water in the province of Quebec, Canada. Twelve municipal wells (raw water) were sampled monthly during a 1 year period, for a total of 160 samples. Using historic data, the 12 sites were categorized into 3 groups: group A (no known contamination), group B (sporadically contaminated by total coliforms), and group C (historic and continuous contamination by total coliforms and (or) fecal coliforms). Bacterial indicators (total coliform, Escherichia coli , enteroccoci), viral indicators (somatic and male-specific coliphages), total culturable human enteric viruses, and noroviruses were analyzed at every sampling site. Total coliforms were the best indicator of microbial degradation, and coliform bacteria were always present at the same time as human enteric viruses. Two samples contained human enteric viruses but no fecal pollution indicators (E. coli, enterococci, or coliphages), suggesting the limited value of these microorganisms in predicting the presence of human enteric viruses in groundwater. Our results underline the value of historic data in assessing the vulnerability of a well on the basis of raw water quality and in detecting degradation of the source. This project allowed us to characterize the microbiologic and virologic quality of groundwater used as municipal drinking water sources in Quebec.


2009 ◽  
Vol 8 (1) ◽  
pp. 11-19 ◽  
Author(s):  
Marta Sofia Valente ◽  
Paulo Pedro ◽  
M. Carmen Alonso ◽  
Juan J. Borrego ◽  
Lídia Dionísio

Monitoring the microbiological quality of water used for recreational activities is very important to human public health. Although the sanitary quality of recreational marine waters could be evaluated by standard methods, they are time-consuming and need confirmation. For these reasons, faster and more sensitive methods, such as the defined substrate-based technology, have been developed. In the present work, we have compared the standard method of membrane filtration using Tergitol-TTC agar for total coliforms and Escherichia coli, and Slanetz and Bartley agar for enterococci, and the IDEXX defined substrate technology for these faecal pollution indicators to determine the microbiological quality of natural recreational waters. ISO 17994:2004 standard was used to compare these methods. The IDEXX for total coliforms and E. coli, Colilert®, showed higher values than those obtained by the standard method. Enterolert® test, for the enumeration of enterococci, showed lower values when compared with the standard method. It may be concluded that more studies to evaluate the precision and accuracy of the rapid tests are required in order to apply them for routine monitoring of marine and freshwater recreational bathing areas. The main advantages of these methods are that they are more specific, feasible and simpler than the standard methodology.


2019 ◽  
Vol 2 (2) ◽  
pp. a13-19
Author(s):  
ELEXSON NILLIAN ◽  
AMIZA NUR ◽  
DIYANA NUR ◽  
AMIRAH ZAKIRAH ◽  
GRACE BEBEY

Contamination of drinks with E. coli O157:H7 served in food premises such as restaurants can cause haemorrhagic colitis and haemolytic uremic syndrome to humans. The presence or absence of faecal pathogen was demonstrated using coliform group as indicator microorganisms. Therefore, this study was conducted to detect the presence of E. coli O157:H7 in drinking water from food restaurant premise in Kota Samarahan and Kuching to ensure safe and potable drinking water is served to the consumer. A total of thirty (n=30) drink samples including six types of each of the samples are cold plain water, iced tea, iced milo, syrup and iced milk tea. Most Probable Number (MPN) procedure was used in this study to enumerate the MPN values of coliform bacteria in each drink collected. A total of 53.33% (16/30) of the drink samples showed positive E. coli detection. Then, the PCR assay showed 6.25% (one out of 16 isolates) samples were positive and carried stx1 gene produced by E. coli O157:H7 in iced milo sample types. This study showed the drinks collected from food premises was contaminated with faecal contamination, which was not safe to drink by the consumer. Therefore, preventive actions should be taken to prevent foodborne illness outbreak in future


1970 ◽  
Vol 24 (2) ◽  
pp. 163-165 ◽  
Author(s):  
Abdul Hussain Shar ◽  
Yasmeen F Kazi ◽  
Miandad Zardari ◽  
Irshad Hussain Soomro

Total coliform (TC) and faecal coliform (FC) bacteria were analyzed in drinking water of Khairpur city. Ninty samples were collected from main reservoir (source), distribution line and consumer taps. pH and residual chlorine of water samples were also determined. For bacteriological analysis inductively membrane filtration (MF) method was used for total coliform (TC) as well as faecal (FC) coliform bacteria. All samples were found contaminated with total coliform (TC) and faecal coliform (FC) and the counts were higher than the maximum microbial contaminant level (MMCL) established by World Health Organization (WHO). It was observed that pH was within the limits of WHO standard (6.5-8.5). The residual chlorine was not detected in any sample of drinking water. Bacteriologically the water quality of the drinking water is unsatisfactory.Keywords: Coliform, Escherichia coli, Water quality, Contamination, SanitationDOI: http://dx.doi.org/10.3329/bjm.v24i2.1266


2012 ◽  
Vol 29 (Special Issue) ◽  
pp. S109-S114
Author(s):  
M. Pejchalová ◽  
P. Hanzalová ◽  
R. Metelka ◽  
J. Vytřasová

Selected springs in the Pardubice Region were repeatedly examined for analytical and microbiological indicators. Microbiological analyses included the determination of intestinal enterococci, coliform bacteria, E. coli, and the number of colonies cultivated at temperature form 22&deg;C to 36&deg;C. The analyses were carried out according to the relevant CSN ISO norms using the membrane filtration technique and also the alternative cultivation method Colilert<sup>&reg;</sup>/Quanti-Tray 2000<sup>&reg;</sup> quantification method using the defined substrate technology. Out of 11 wells and springs examined, only two satisfied the requirements for potable water with all indicators observed.


Sign in / Sign up

Export Citation Format

Share Document