Virus elimination in activated sludge systems: from batch tests to mathematical modeling

2014 ◽  
Vol 70 (6) ◽  
pp. 1115-1121 ◽  
Author(s):  
Emma Haun ◽  
Katharina Ulbricht ◽  
Regina Nogueira ◽  
Karl-Heinz Rosenwinkel

A virus tool based on Activated Sludge Model No. 3 for modeling virus elimination in activated sludge systems was developed and calibrated with the results from laboratory-scale batch tests and from measurements in a municipal wastewater treatment plant (WWTP). The somatic coliphages were used as an indicator for human pathogenic enteric viruses. The extended model was used to simulate the virus concentration in batch tests and in a municipal full-scale WWTP under steady-state and dynamic conditions. The experimental and modeling results suggest that both adsorption and inactivation processes, modeled as reversible first-order reactions, contribute to virus elimination in activated sludge systems. The model should be a useful tool to estimate the number of viruses entering water bodies from the discharge of treated effluents.

Author(s):  
Bilge Alpaslan Kocamemi ◽  
Halil Kurt ◽  
Ahmet Sait ◽  
Fahriye Sarac ◽  
Ahmet Mete Saatci ◽  
...  

Following the announcement of SARS-CoV-2 worldwide pandemic spread by WHO on March 11, 2020, wastewater based epidemiology received great attention in several countries: The Netherlands [Medama et al., 2020; K-Lodder et al., 2020], USA [Wu et al., 2020; Memudryi et al., 2020], Australia [Ahmed et al., 2020], France [Wurtzer et al., 2020], China [Wang et al., 2020], Spain [Randazzo et al., 2020; Walter et al., 2020], Italy (La Rosa et al., 2020; Rimoldi et al., 2020) and Israel [Or et al., 2020], performed analysis in wastewaters by using different virus concentration techniques. Turkey took its place among these countries on 7th of May, 2020 by reporting SARS-CoV-2 RT-qPCR levels at the inlet of seven (7) major municipal wastewater treatment plants (WWTPs) of Istanbul [Alpaslan Kocamemi et al., 2020], which is a metropole with 15.5 million inhabitants and a very high population density (2987 persons/km2) and having about 65 % of Covid-19 cases in Turkey. Sludges that are produced in WWTPs should be expected to contain SARS-CoV-2 virus as well. There has not yet been any study for the fate of SAR-CoV-2 in sludges generated from WWTPs. Knowledge about the existing of SARS-CoV-2 in sludge may be useful for handling the sludge during its dewatering, stabilizing and disposal processes. This information will also be valuable in case of sludges that are used as soil conditioners in agriculture or sent to landfill disposal. In wastewater treatment plants, generally two different types of sludges are generated; primary sludge (PS) and waste activated sludge (WAS). PS forms during the settling of wastewater by gravity in the primary settling tanks. Little decomposition occurs during primary sludge formation. Since most of the inorganic part of the wastewater is removed in the earlier grit removal process, the PS consists of mainly organic material that settles. The PS is about 1-2 % solids by weight. In the biological treatment part of the WWTPs, the biomass that forms in the anaerobic, anoxic and oxic zones of the process is settled in final clarifiers by gravity and returned to the beginning of the biological process so that it is not washed off. The waste activated sludge (WAS) is the excess part of the biomass that grows in this secondary treatment process. It has to be removed from the process not to increase the mixed liquor suspended solids concentration (bacteria concentration) in the secondary process more than a fixed value. The WAS is about 0.6 - 0.9 % solids by weight. This work aims to find whether SARS-CoV-19 is present in the PS and WAS before it is dewatered and sent to anaerobic or aerobic digester processes or to thermal drying operations. For this purpose, on the 7th of May 2020, two (2) PS samples were collected from Ambarlı and Tuzla WWTPs, seven (7) WAS samples were collected from Terkos, Ambarlı, Atakoy I & II, Pasakoy II, Buyukcekmece and Tuzla I WWTPs. Polyethylene glycol 8000 (PEG 8000) adsorption [Wu et al., 2020] SARS-Cov-2 concentration method was used for SARS-CoV-2 concentration after optimization. [Alpaslan Kocamemi et al., 2020]. Real time RT-PCR diagnostic panel validated by US was used to quantify SARS-CoV-2 RNA in primary and waste activated sludge samples taken from WWTPs in Istanbul. All samples were tested positive. Titers of SARS-CoV-2 have been detected ranging copies between 1.17E4 to 4.02x104 per liter.


2004 ◽  
Vol 50 (3) ◽  
pp. 1-10 ◽  
Author(s):  
P.A. Barañao ◽  
E.R. Hall

Activated Sludge Model No 3 (ASM3) was chosen to model an activated sludge system treating effluents from a mechanical pulp and paper mill. The high COD concentration and the high content of readily biodegradable substrates of the wastewater make this model appropriate for this system. ASM3 was calibrated based on batch respirometric tests using fresh wastewater and sludge from the treatment plant, and on analytical measurements of COD, TSS and VSS. The model, developed for municipal wastewater, was found suitable for fitting a variety of respirometric batch tests, performed at different temperatures and food to microorganism ratios (F/M). Therefore, a set of calibrated parameters, as well as the wastewater COD fractions, was estimated for this industrial wastewater. The majority of the calibrated parameters were in the range of those found in the literature.


2007 ◽  
Vol 73 (6) ◽  
pp. 1952-1960 ◽  
Author(s):  
A. Schlüter ◽  
R. Szczepanowski ◽  
N. Kurz ◽  
S. Schneiker ◽  
I. Krahn ◽  
...  

ABSTRACT The erythromycin resistance plasmid pRSB105 was previously isolated from an activated sludge bacterial community of a municipal wastewater treatment plant. Compilation of the complete pRSB105 nucleotide sequence revealed that the plasmid is 57,137 bp in size and has a mean G+C content of 56.66 mol%. The pRSB105 backbone is composed of two different replication and/or partitioning modules and a functional mobilization region encoding the mobilization genes mobCDE and mobBA. The first replicon (Rep1) is nearly identical to the corresponding replication module of the multiresistance plasmid pRSB101 isolated from an unknown activated sludge bacterium. Accordingly, pRSB101 and pRSB105 are sister plasmids belonging to a new plasmid family. The second replicon (Rep2) of pRSB105 was classified as a member of the IncP-6 group. While Rep1 confers replication ability only in γ-proteobacteria, Rep2 extents the host range of the plasmid since it is also functional in the β-proteobacterium Ralstonia eutropha. Plasmid pRSB105 harbors the macrolide resistance genes mel and mph, encoding, respectively, a predicted ABC-type efflux permease and a macrolide-2′-phosphotransferase. Erythromycin resistance is mainly attributed to mel, whereas mph contributes to erythromycin resistance to a lesser extent. The second resistance region, represented by an integron-containing Tn402-like element, includes a β-lactam (oxa10) and a trimethoprim (dfrB2) resistance gene cassette. In addition to antibiotic resistance modules, pRSB105 encodes a functional restriction/modification system and two nonresistance regions of unknown function. The presence of different mobile genetic elements that flank resistance and nonresistance modules on pRSB105 indicates that these elements were involved in acquisition of accessory plasmid modules. Comparative genomics of pRSB105 and related plasmids elucidated that pRSB105 evolved by integration of distinct modules from different plasmid sources, including Pseudomonas aeruginosa plasmids, and thus represents a mosaic plasmid.


1998 ◽  
Vol 38 (1) ◽  
pp. 303-310 ◽  
Author(s):  
V. Naidoo ◽  
V. Urbain ◽  
C. A. Buckley

Denitrification kinetics and wastewater characterization of eight different plants in Europe are discussed. Denitrification batch tests revealed three distinct rates except in the cases of Plaisir, Rostock and Orense where 4 rates were observed. The latter three plants revealed atypical rapid initial rates which were between 7 and 21 mgN/gVSS.h. All denitrification kinetics under non-limiting carbon conditions revealed fast first rates which ranged between 3.0 and 7.3 mgN/gVSS.h. Acetate was used to simulate denitrification kinetics with readily biodegradable COD present. Two subsequent rates were observed. Rates 2 and 3 ranged between 2 and 3 mgN/gVSS.h, and 1 and 2 mgN/gVSS.h, respectively. The RBCOD fraction varied between 10 and 19%, except for one of the plants where the value determined was 7%.


1992 ◽  
Vol 25 (6) ◽  
pp. 167-183 ◽  
Author(s):  
H. Siegrist ◽  
M. Tschui

The wastewater of the municipal treatment plants Zürich-Werdhölzli (350000 population equivalents), Zürich-Glatt (110000), and Wattwil (20000) have been characterized with regard to the activated sludge model Nr.1 of the IAWPRC task group. Zürich-Glatt and Wattwil are partly nitrifying treatment plants and Zürich-Werdhölzli is fully nitrifying. The mixing characteristics of the aeration tanks at Werdhölzli and Glatt were determined with sodium bromide as a tracer. The experimental data were used to calibrate hydrolysis, heterotrophic growth and nitrification. Problems arising by calibrating hydrolysis of the paniculate material and by measuring oxygen consumption of heterotrophic and nitrifying microorganisms are discussed. For hydrolysis the experimental data indicate first-order kinetics. For nitrification a maximum growth rate of 0.40±0.07 d−1, corresponding to an observed growth rate of 0.26±0.04 d−1 was calculated at 10°C. The half velocity constant found for 12 and 20°C was 2 mg NH4-N/l. The calibrated model was verified with experimental dam of me Zürich-Werdhölzli treatment plant during ammonia shock load.


2019 ◽  
Vol 11 (3) ◽  
pp. 622 ◽  
Author(s):  
Isabella Pecorini ◽  
Francesco Baldi ◽  
Renato Iannelli

Four inocula collected from different operating facilities were tested in their hydrogenic performances by means of two biochemical hydrogen potential test set-ups using sucrose and food waste as substrates, with the aim of evaluating the influence of inoculum media in batch fermentative assays. The selected inocula were: activated sludge collected from the aerobic unit of a municipal wastewater treatment plant, digested sludge from an anaerobic reactor treating organic waste and cattle manure, digested sludge from an anaerobic reactor treating agroindustrial residues, and digested sludge from an anaerobic reactor of a municipal wastewater treatment plant. Test results, in terms of specific hydrogen production, hydrogen conversion efficiency, and volatile solids removal efficiency, were significantly dependent on the type of inoculum. Statistical analysis showed different results, indicating that findings were due to the different inocula used in the tests. In particular, assays performed with activated sludge showed the highest performances for both substrates and both experimental set-ups.


2019 ◽  
Vol 80 (9) ◽  
pp. 1654-1661
Author(s):  
J. Tauber ◽  
V. Parravicini ◽  
K. Svardal ◽  
J. Krampe

Abstract In this research, sources of methane emissions of an anaerobic digester (AD) system at a municipal wastewater treatment plant (WWTP) with 260,000 population equivalent (PE) capacity were detected by a non-dispersive infrared (NDIR) camera. The located emissions were evaluated qualitatively and were documented with photographs and video films. Subsequently, the emission sources were quantified individually using different methods like the Flux-Chamber method and sampling from the digester's circulation pipe. The dissolved methane in the sludge digester was measured via gas chromatography-mass spectrometry (GC-MS) and 6.8% oversaturation compared to the equilibrium after Henry's law was found. Additionally, the residual gas potential of the digestate was measured using batch tests with 10 days' additional stabilisation time. The PE-specific residual gas production of the full-scale AD was calculated to 12.4 g CH4/(PE · y). An extended chemical oxygen demand (COD) balance including methane emissions for the whole digester system was calculated. Also the measured methane loads were calculated and summed up. The total methane loss of the AD was calculated at 24.6 g CH4/(PE · y), which corresponds to 0.4% of the produced biogas (4,913 g CH4/(PE · y)). PE-specific methane emission factors are presented for each investigated (point) source like the sludge outlet at the digester's head, a leaking manhole sealing and cracks in the concrete structure.


Sign in / Sign up

Export Citation Format

Share Document