scholarly journals Assessment of water hammer effects on boiling water nuclear reactor core dynamics

2007 ◽  
Vol 22 (1) ◽  
pp. 18-33 ◽  
Author(s):  
Anis Bousbia-Salah

Complex phenomena, as water hammer transients, occurring in nuclear power plants are still not very well investigated by the current best estimate computational tools. Within this frame work, a rapid positive reactivity addition into the core generated by a water hammer transient is considered. The numerical simulation of such phenomena was carried out using the coupled RELAP5/PARCS code. An over all data comparison shows good agreement between the calculated and measured core pressure wave trends. However, the predicted power response during the excursion phase did not correctly match the experimental tendency. Because of this, sensitivity studies have been carried out in order to identify the most influential parameters that govern the dynamics of the power excursion. After investigating the pressure wave amplitude and the void feed back responses, it was found that the disagreement between the calculated and measured data occurs mainly due to the RELAP5 low void condensation rate which seems to be questionable during rapid transients. .

Author(s):  
Robert A. Leishear

An explosion that burst a steel pipe like a paper fire cracker at the Hamaoka Nuclear Power Station, Unit-1 is investigated in this paper, which is one of a series of papers investigating fires and explosions in nuclear power plants. The accumulation of flammable hydrogen and oxygen due to radiolysis has long been recognized as a potential problem in nuclear reactors, where radiolysis is the process that decomposes water into hydrogen and oxygen by radiation exposure in the reactor core. Hydrogen ignition and explosion has long been considered the cause of this Hamaoka piping explosion, but the cause of ignition was considered to be a minor fluid transient, or water hammer, that ignited flammable gasses in the piping, which was made possible by the presence of catalytic noble metals inside the piping. The theory presented here is that a much larger pressure surge occurred due to water hammer during operations. In fact, calculations presented here serve as proof of principle that this explosion mechanism may be present in many operating nuclear power plants. Chubu Electric, the operator of the Hamaoka plant, took appropriate actions to prevent this type of explosion in their plants in the future. In fact, this accident indicates one potential preventive action from explosions for other operating plants. Ensure that a system high point is available, where mixed hydrogen and oxygen may be removed during routine operations and during off-normal accident conditions, such as nuclear reactor meltdowns and loss of coolant accidents.


Author(s):  
Robert A. Leishear

Water hammers, or fluid transients, compress flammable gasses to their autognition temperatures in piping systems to cause fires or explosions. While this statement may be true for many industrial systems, the focus of this research are reactor coolant water systems (RCW) in nuclear power plants, which generate flammable gasses during normal operations and during accident conditions, such as loss of coolant accidents (LOCA’s) or reactor meltdowns. When combustion occurs, the gas will either burn (deflagrate) or explode, depending on the system geometry and the quantity of the flammable gas and oxygen. If there is sufficient oxygen inside the pipe during the compression process, an explosion can ignite immediately. If there is insufficient oxygen to initiate combustion inside the pipe, the flammable gas can only ignite if released to air, an oxygen rich environment. This presentation considers the fundamentals of gas compression and causes of ignition in nuclear reactor systems. In addition to these ignition mechanisms, specific applications are briefly considered. Those applications include a hydrogen fire following the Three Mile Island meltdown, hydrogen explosions following Fukushima Daiichi explosions, and on-going fires and explosions in U.S nuclear power plants. Novel conclusions are presented here as follows. 1. A hydrogen fire was ignited by water hammer at Three Mile Island. 2. Hydrogen explosions were ignited by water hammer at Fukushima Daiichi. 3. Piping damages in U.S. commercial nuclear reactor systems have occurred since reactors were first built. These damages were not caused by water hammer alone, but were caused by water hammer compression of flammable hydrogen and resultant deflagration or detonation inside of the piping.


2021 ◽  
Vol 30 (5) ◽  
pp. 66-75
Author(s):  
S. A. Titov ◽  
N. M. Barbin ◽  
A. M. Kobelev

Introduction. The article provides a system and statistical analysis of emergency situations associated with fires at nuclear power plants (NPPs) in various countries of the world for the period from 1955 to 2019. The countries, where fires occurred at nuclear power plants, were identified (the USA, Great Britain, Switzerland, the USSR, Germany, Spain, Japan, Russia, India and France). Facilities, exposed to fires, are identified; causes of fires are indicated. The types of reactors where accidents and incidents, accompanied by large fires, have been determined.The analysis of major emergency situations at nuclear power plants accompanied by large fires. During the period from 1955 to 2019, 27 large fires were registered at nuclear power plants in 10 countries. The largest number of major fires was registered in 1984 (three fires), all of them occurred in the USSR. Most frequently, emergency situations occurred at transformers and cable channels — 40 %, nuclear reactor core — 15 %, reactor turbine — 11 %, reactor vessel — 7 %, steam pipeline systems, cooling towers — 7 %. The main causes of fires were technical malfunctions — 33 %, fires caused by the personnel — 30 %, fires due to short circuits — 18 %, due to natural disasters (natural conditions) — 15 % and unknown reasons — 4 %. A greater number of fires were registered at RBMK — 6, VVER — 5, BWR — 3, and PWR — 3 reactors.Conclusions. Having analyzed accidents, involving large fires at nuclear power plants during the period from 1955 to 2019, we come to the conclusion that the largest number of large fires was registered in the USSR. Nonetheless, to ensure safety at all stages of the life cycle of a nuclear power plant, it is necessary to apply such measures that would prevent the occurrence of severe fires and ensure the protection of personnel and the general public from the effects of a radiation accident.


Author(s):  
Zhe Dong ◽  
Xiaojin Huang ◽  
Liangju Zhang

The modular high-temperature gas-cooled nuclear reactor (MHTGR) is seen as one of the best candidates for the next generation of nuclear power plants. China began to research the MHTGR technology at the end of the 1970s, and a 10 MWth pebble-bed high temperature reactor HTR-10 has been built. On the basis of the design and operation of the HTR-10, the high temperature gas-cooled reactor pebble-bed module (HTR-PM) project is proposed. One of the main differences between the HTR-PM and HTR-10 is that the ratio of height to diameter corresponding to the core of the HTR-PM is much larger than that of the HTR-10. Therefore it is not proper to use the point kinetics based model for control system design and verification. Motivated by this, a nodal neutron kinetics model for the HTR-PM is derived, and the corresponding nodal thermal-hydraulic model is also established. This newly developed nodal model can reflect not only the total or average information but also the distribution information such as the power distribution as well. Numerical simulation results show that the static precision of the new core model is satisfactory, and the trend of the transient responses is consistent with physical rules.


2011 ◽  
Vol 11 (11) ◽  
pp. 31207-31230 ◽  
Author(s):  
J. Lelieveld ◽  
D. Kunkel ◽  
M. G. Lawrence

Abstract. Reactor core meltdowns of nuclear power plants are rare, yet the consequences are catastrophic. But what is meant by "rare"? And what can be learned from the Chernobyl and Fukushima incidents? Here we assess the risk of exposure to radioactivity due to atmospheric dispersion of gases and particles following severe nuclear accidents, using particulate 137Cs and gaseous 131I as proxies for the fallout. It appears that previously the occurrence of major accidents and the risks of radioactive contamination have been underestimated. Using a global model of the atmosphere we compute that on average, in the event of a core melt of any nuclear power plant worldwide, more than 90% of emitted 137Cs would be transported beyond 50km and about 50% beyond 1000 km distance. This corroborates that such accidents have large-scale and trans-boundary impacts. Although the emission strengths and atmospheric removal processes of 137Cs and 131I are quite different, the radioactive contamination patterns over land and the human deposition exposure are computed to be similar. High human exposure risks occur around reactors in densely populated regions, notably in southern Asia where a core melt can subject 55 million people to radioactive contamination. The recent decision by Germany to phase out its nuclear reactors will reduce the national risk, though a large risk will still remain from the reactors in neighbouring countries.


Author(s):  
Xing Li ◽  
Sichao Tan ◽  
Zhengpeng Mi ◽  
Peiyao Qi ◽  
Yunlong Huang

Thermal hydraulic research of reactor core is important in nuclear energy applications, the flow and heat transfer characteristics of coolant in reactor fuel assembly has a great influence on the performance and safety of nuclear power plants. Particle image velocimetry (PIV) and Laser induced fluorescence (LIF) are the instantaneous, non-intrusive, whole-field fluid mechanics measuring method. In this study, the simultaneous measurement of flow field and temperature field for a rod bundle was conducted using PIV and LIF technique. A facility system, utilizing the matching index of refraction approach, has been designed and constructed for the measurement of velocity and temperature in the rod bundle. In order for further study on complex heat and mass transfer characteristic of rod bundle, the single-phase experiments on the heating conditions are performed. One of unique characteristics of the velocity and temperature distribution downstream the spacer grid was obtained. The experimental results show that the combined use of PIV and LIF technique is applied to the measurement of multi-physical field in a rod bundle is feasible, the measuring characteristics of non-intrusive ensured accuracy of whole field data. The whole field experimental data obtained in rod bundle benefits the design of spacer grid geometry.


Author(s):  
Thomas G. Scarbrough

In a series of Commission papers, the U.S. Nuclear Regulatory Commission (NRC) described its policy for inservice testing (IST) programs to be developed and implemented at nuclear power plants licensed under 10 CFR Part 52. This paper discusses the expectations for IST programs based on those Commission policy papers as applied in the NRC staff review of combined license (COL) applications for new reactors. For example, the design and qualification of pumps, valves, and dynamic restraints through implementation of American Society of Mechanical Engineers (ASME) Standard QME-1-2007, “Qualification of Active Mechanical Equipment Used in Nuclear Power Plants,” as accepted in NRC Regulatory Guide (RG) 1.100 (Revision 3), “Seismic Qualification of Electrical and Active Mechanical Equipment and Functional Qualification of Active Mechanical Equipment for Nuclear Power Plants,” will enable IST activities to assess the operational readiness of those components to perform their intended functions. ASME has updated the Operation and Maintenance of Nuclear Power Plants (OM Code) to improve the IST provisions for pumps, valves, and dynamic restraints that are incorporated by reference in the NRC regulations with applicable conditions. In addition, lessons learned from performance experience and testing of motor-operated valves (MOVs) will be implemented as part of the IST programs together with application of those lessons learned to other power-operated valves (POVs). Licensee programs for the Regulatory Treatment of Non-Safety Systems (RTNSS) will be implemented for components in active nonsafety-related systems that are the first line of defense in new reactors that rely on passive systems to provide reactor core and containment cooling in the event of a plant transient. This paper also discusses the overlapping testing provisions specified in ASME Standard QME-1-2007; plant-specific inspections, tests, analyses, and acceptance criteria; the applicable ASME OM Code as incorporated by reference in the NRC regulations; specific license conditions; and Initial Test Programs as described in the final safety analysis report and applicable RGs. Paper published with permission.


Author(s):  
Xiaomeng Dong ◽  
Zhijian Zhang ◽  
Zhaofei Tian ◽  
Lei Li ◽  
Guangliang Chen

Multi-physics coupling analysis is one of the most important fields among the analysis of nuclear power plant. The basis of multi-physics coupling is the coupling between neutronics and thermal-hydraulic because it plays a decisive role in the computation of reactor power, outlet temperature of the reactor core and pressure of vessel, which determines the economy and security of the nuclear power plant. This paper develops a coupling method which uses OPENFOAM and the REMARK code. OPENFOAM is a 3-dimension CFD open-source code for thermal-hydraulic, and the REMARK code (produced by GSE Systems) is a real-time simulation multi-group core model for neutronics while it solves diffusion equations. Additionally, a coupled computation using these two codes is new and has not been done. The method is tested and verified using data of the QINSHAN Phase II typical nuclear reactor which will have 16 × 121 elements. The coupled code has been modified to adapt unlimited CPUs after parallelization. With the further development and additional testing, this coupling method has the potential to extend to a more large-scale and accurate computation.


2020 ◽  
Author(s):  
Evrim Oyguc ◽  
Abdul Hayır ◽  
Resat Oyguc

Increasing energy demand urge the developing countries to consider different types of energy sources. Owing the fact that the energy production capacity of renewable energy sources is lower than a nuclear power plant, developed countries like US, France, Japan, Russia and China lead to construct nuclear power plants. These countries compensate 80% of their energy need from nuclear power plants. Further, they periodically conduct tests in order to assess the safety of the existing nuclear power plants by applying impact type loads to the structures. In this study, a sample third-generation nuclear reactor building has been selected to assess its seismic behavior and to observe the crack propagations of the prestressed outer containment. First, a 3D model has been set up using ABAQUS finite element program. Afterwards, modal analysis is conducted to determine the mode shapes. Nonlinear dynamic time history analyses are then followed using an artificial strong ground motion which is compatible with the mean design spectrum of the previously selected ground motions that are scaled to Eurocode 8 Soil type B design spectrum. Results of the conducted nonlinear dynamic analyses are considered in terms of stress distributions and crack propagations.


2018 ◽  
Vol 20 (1) ◽  
pp. 1 ◽  
Author(s):  
Sri Sudadiyo

Nowadays, pumps are being widely used in the thermal power generation including nuclear power plants. Reaktor Daya Eksperimental (RDE) is a proposed nuclear reactor concept for the type of nuclear power plant in Indonesia. This RDE has thermal power 10 MWth, and uses a feedwater pump within its steam cycle. The performance of feedwater pump depends on size and geometry of impeller model, such as the number of blades and the blade angle. The purpose of this study is to perform a preliminary design on an impeller of feedwater pump for RDE and to simulate its performance characteristics. The Fortran code is used as an aid in data calculation in order to rapidly compute the blade shape of feedwater pump impeller, particularly for a RDE case. The calculations analyses is solved by utilizing empirical correlations, which are related to size and geometry of a pump impeller model, while performance characteristics analysis is done based on velocity triangle diagram. The effect of leakage, pass through the impeller due to the required clearances between the feedwater pump impeller and the volute channel, is also considered. Comparison between the feedwater pump of HTR-10 and of RDE shows similarity in the trend line of curve shape. These characteristics curves will be very useful for the values prediction of performance of a RDE feedwater pump. Preliminary design of feedwater pump provides the size and geometry of impeller blade model with 5-blades, inlet angle 14.5 degrees, exit angle 25 degrees, inside diameter 81.3 mm, exit diameter 275.2 mm, thickness 4.7 mm, and height 14.1 mm. In addition, the optimal values of performance characteristics were obtained when flow capacity was 4.8 kg/s, fluid head was 29.1 m, shaft mechanical power was 2.64 kW, and efficiency was 52 % at rotational speed 1750 rpm.Keywords: Blade, impeller, pump, RDEDESAIN AWAL IMPELER POMPA AIR UMPAN RDE. Saat ini, pompa digunakan secara luas dalam pembangkit tenaga termal termasuk pembangkit listrik tenaga nuklir. Reaktor Daya Eksperimental (RDE) merupakan konsep reaktor nuklir yang diusulkan untuk tipe PLTN di Indonesia. RDE ini memiliki daya termal 10 MWth, dan menggunakan pompa air umpan dalam siklus uapnya. Kinerja pompa air umpan bergantung pada ukuran dan geometri model impeller, seperti jumlah sudu dan sudut sudu. Tujuan dari penelitian ini adalah untuk membuat rancangan awal impeller pompa air umpan untuk RDE dan untuk mensimulasikan karakteristik kinerjanya. Kode Fortran digunakan sebagai bantuan dalam penghitungan data untuk untuk mengkalkulasi secara cepat bentuk sudu impeller pompa air umpan, terutama pada kasus RDE. Analisis perhitungan dipecahkan menggunakan korelasi empiris yang terkait dengan ukuran dan geometri model impeller pompa, sedangkan analisis karakteristik kinerja dilakukan berdasarkan diagram segitiga kecepatan. Pengaruh bocoran, melalui impeler akibat celah yang diperlukan antara impeller pompa air umpan dan saluran volute, juga dipertimbangkan. Perbandingan antara pompa air umpan HTR-10 dan RDE menunjukkan kemiripan dalam garis tren bentuk kurva. Kurva karakteristik ini akan sangat berguna untuk perkiraan nilai kinerja pompa air umpan RDE. Desain awal pompa air umpan memberikan ukuran dan geometri model sudu impeller dengan 5-sudu, sudut masuk 14,5 derajat, sudut keluar 25 derajat, diameter dalam 81,3 mm, diameter luar 275,2 mm, ketebalan 4,7 mm, dan tinggi 14,1 mm. Selain itu, nilai optimal karakteristik kinerja diperoleh ketika kapasitas aliran 4,8 kg/s, head fluida 29,1 m, tenaga mekanik poros 2,64 kW, dan efisiensi 52 % pada kecepatan putaran 1750 rpm.Kata kunci: Sudu, impeler, pompa, RDE


Sign in / Sign up

Export Citation Format

Share Document