Effect of Deep Margin Elevation on Interfacial Gap Development of CAD/CAM Inlays after Thermomechanical Cycling

2021 ◽  
Author(s):  
W Moon ◽  
SH Chung ◽  
J Chang

SUMMARY The aim of this study was to evaluate interfacial gap formation of CAD/CAM lithium disilicate inlay margins before and after thermomechanical loading. Methods and Materials: Mesio-occlusal-distal cavities were prepared on 12 extracted mandibular molars. The gingival margin of one proximal box was elevated with resin modified glass ionomer (RMGI) by a height of 2 mm (Group E [elevation]), and the margin of the other side served as a control (Group NE [no elevation]). Lithium disilicate computer-aided design and computer-aided manufacturing (CAD/CAM) inlays were fabricated and bonded with a self-adhesive resin cement. An aging process was simulated on the specimens under thermomechanical cycling by using a chewing simulator. Marginal integration was evaluated under scanning electron miscroscopy (SEM) using epoxy resin replicas before and after cycling. Marginal areas were stained with silver nitrate solution, and the volumetric gap was measured at the bonded interfaces using microcomputed tomography (CT) before and after cycling. Statistical analyses were performed using paired t-tests, the Wilcoxon signed rank test, and the Mann–Whitney test (a<0.05). Results: SEM showed marginal discontinuities in Group NE that increased after thermomechanical cycling. Micro-computed tomography exhibited three-dimensional dye-penetrating patterns at the interfaces before and after cycling. Interfacial disintegration was larger in Group NE before cycling (p<0.05). Thermomechanical cycling increased the gaps in both Groups NE and E (p<0.05). The gap increment from thermomechanical cycling was larger in Group NE (p<0.05). Conclusions: Thermomechanical cycling induced interfacial disintegration at the lithium disilicate CAD/CAM inlays, with deep proximal margins. Margin elevation with RMGI placement reduced the extent of the interfacial gap formation before and after the aging simulation.

2019 ◽  
Vol 18 ◽  
pp. e191573
Author(s):  
Silas Monteiro Borges ◽  
Stephanie Francoi Poole ◽  
Izabela Cristina Maurício Moris ◽  
Aloísio Oro Spazzin ◽  
Adriana Cláudia Lapria Faria ◽  
...  

Aim: This study evaluated the mechanical behavior of implant-supported crowns obtained by different fabrication technique after thermomechanical cycling. Methods: Thirty-two external hexagon dental implants were divided into four groups (n=10): CC – conventional casting with torch; EI – electromagnetic induction casting; PL – plasma casting; and CAD-CAM – milling through computer-aided design and computer-aided manufacturing. Vickers microhardness of the specimens were made before and after the thermomechanical cycling, and then subjected to fracture load. Fracture pattern was evaluated. Results: No significant difference was observed comparing the microhardness before and after thermomechanical cycling. CAD-CAM group presented significant lower microhardness than the other groups. No significant statistical difference was showed on fracture load between the groups. The CAD-CAM and PL presented lower number of failure by plastic deformation. Conclusion: The manufacturing techniques affected the mechanical behavior and the failure pattern of implant-supported crowns tested.


Medicina ◽  
2020 ◽  
Vol 56 (3) ◽  
pp. 132
Author(s):  
Georgina García-Engra ◽  
Lucia Fernandez-Estevan ◽  
Javier Casas-Terrón ◽  
Antonio Fons-Font ◽  
Pablo Castelo-Baz ◽  
...  

Background and Objectives: To evaluate in vitro the fracture resistance and fracture type of computer-aided design and computer-aided manufacturing (CAD-CAM) materials. Materials and Methods: Discs were fabricated (10 × 1.5 mm) from four test groups (N = 80; N = 20 per group): lithium disilicate (LDS) group (control group): IPS e.max CAD®; zirconium-reinforced lithium silicate (ZRLS) group: VITA SUPRINITY®; polymer-infiltrated ceramic networks (PICN) group: VITA ENAMIC®; resin nanoceramics (RNC) group: LAVA™ ULTIMATE. Each disc was cemented (following the manufacturers’ instructions) onto previously prepared molar dentin. Samples underwent until fracture using a Shimadzu® test machine. The stress suffered by each material was calculated with the Hertzian model, and its behavior was analyzed using the Weibull modulus. Data were analyzed with ANOVA parametric statistical tests. Results: The LDS group obtained higher fracture resistance (4588.6 MPa), followed by the ZRLS group (4476.3 MPa) and PICN group (4014.2 MPa) without statistically significant differences (p < 0.05). Hybrid materials presented lower strength than ceramic materials, the RNC group obtaining the lowest values (3110 MPa) with significant difference (p < 0.001). Groups PICN and RNC showed greater occlusal wear on the restoration surface prior to star-shaped fracture on the surface, while other materials presented radial fracture patterns. Conclusion: The strength of CAD-CAM materials depended on their composition, lithium disilicate being stronger than hybrid materials.


2016 ◽  
Vol 41 (1) ◽  
pp. 76-82 ◽  
Author(s):  
AO Carvalho ◽  
G Bruzi ◽  
RE Anderson ◽  
HP Maia ◽  
M Giannini ◽  
...  

SUMMARY Objective To assess the influence of adhesive core buildup designs (4-mm buildup, 2-mm buildup, and no buildup/endocrown) on the fatigue resistance and failure mode of endodontically treated molar teeth restored with lithium disilicate computer-aided design/computer-aided manufacturing (CAD/CAM) complete crowns placed with self-adhesive cement. Methods and Materials Forty-five extracted molars were decoronated at the level of the cementoenamel junction and endodontically treated. Specimens received different Filtek Z100 adhesive core buildups (4-mm buildup; 2-mm buildup; and no buildup endocrown preparation) and were restored with Cerec 3 CAD/CAM lithium disilicate crowns (IPS e.max CAD). The intaglio surfaces of restorations (n=15) were conditioned by hydrofluoric acid etching and silane, and prepared teeth were treated with airborne-particle abrasion, followed by cementation with RelyX Unicem 2 Automix. Specimens were then subjected to cyclic isometric loading at 10 Hz, beginning with a load of 200 N (×5000 cycles), followed by stages of 400, 600, 800, 1000, 1200, and 1400 N at a maximum of 30,000 cycles each. Specimens were loaded until failure or to a maximum of 185,000 cycles. The chewing cycle was simulated by an isometric contraction (load control) applied through a 10-mm in diameter composite resin sphere (Filtek Z100). Surviving specimens were axially loaded until failure or to a maximum load of 4500 N (crosshead speed 0.5 mm/min). The failure mode was assessed, and fractures were designated as catastrophic (tooth/root fracture that would require tooth extraction) or reparable (cohesive or cohesive/adhesive fracture of restoration only). Groups were compared using the life table survival analysis (log-rank test at p=0.05). Surviving specimens were loaded to failure and compared with one-way analysis of variance. Results The survival rates after the fatigue test were 100%, 93%, and 100% for 4-mm, 2-mm, and no buildup (endocrown), respectively and were not statistically different (only one specimen failed with a 2-mm buildup under a crown that cohesively fractured at 1,400 N). Postfatigue load to failure averaged 3181 N for 4-mm buildups (15 specimens), 3759 N for 2-mm buildups (12 specimens), and 3265 N for endocrowns (14 specimens). The 2-mm buildups were associated with higher loads to failure than endocrowns and 4-mm buildups, but no differences were found between 4-mm buildups and endocrowns (p&lt;0.05.) One endocrown and 2 restorations with a 2-mm buildup survived the load-to-failure test (at 4500 N). Only catastrophic fractures occurred after the load-to-failure test. Conclusions The buildup design influenced the performance of endodontically treated molars restored with lithium disilicate CAD/CAM complete crowns placed with self-adhesive resin cement. The 2-mm buildups were associated with higher loads to failure than the endocrown and the 4-mm buildup, but all restoration designs survived far beyond the normal range of masticatory forces.


2021 ◽  
Vol 19 ◽  
pp. 228080002110588
Author(s):  
Sarah S. Al-Angari ◽  
Shahad Meaigel ◽  
Nouf Almayouf ◽  
Shahad Quwayhis ◽  
Abdulelah Aldahash ◽  
...  

Objectives: To investigate the effects of a coffee beverage and two whitening systems on the surface roughness and gloss of glazed Lithium Disilicate Glass-Ceramics (LDGC) for computer-aided design/computer-aided manufacturing (CAD/CAM) systems. Methods: Sixty-eight LDGC disks (12 × 10 × 2 mm) were prepared from blocks of CAD/CAM systems (IPS e.max CAD ceramic). Baseline measurements for surface roughness (Ra) and gloss (GU) were taken using a 3-D optical profilometer and a glossmeter, respectively; then specimens were randomized into four groups ( n = 17). All specimens were immersed in a coffee solution (24 h × 12 days) then subjected to two whitening systems. G1-negative control (kept moist × 7 days); G2-positive control (brushed with distilled water, 200 g/load, 2 min twice daily × 7 days); G3-whitening toothpaste (Colgate optic white; relative dentin abrasivity (RDA) = 100, 200 g/load, 2 min twice daily × 7 days); and G4-simulated at-home bleaching protocol (Opalescence,15% carbamide peroxide (CP), 6 h/day × 7 days). The study outcomes were measured at baseline and after the treatments. Data were analyzed using paired T-test and one-way ANOVA (α = 0.05). Results: The mean surface roughness significantly increased ( p ⩽ 0.002) for all groups after the designated treatment protocols. Among groups, the mean surface roughness of G2 and G3 were significantly higher ( p ⩽ 0.001) (Ra: 0.51 and 0.57 μm, respectively) compared to the control group (Ra: 0.23 μm), and were not significantly different from G4 (Ra: 0.46 μm). Surface gloss decreased with no significant change within or among groups after treatment. Conclusion: All glazed LDGC had a significant increase in surface roughness after being subjected to simulated 1 year of coffee drinking and whitening systems (15% CP and whitening toothpaste), and the greatest change was associated with brushing (simulating 8 months). However, coffee beverages and whitening systems had no significant effect on the surface gloss.


2016 ◽  
Vol 2016 ◽  
pp. 1-6 ◽  
Author(s):  
Jae-Hong Kim ◽  
Seunghan Oh ◽  
Soo-Hyuk Uhm

The aim of this study is to quantify the effect of the crystallization process on lithium disilicate ceramic crowns fabricated using a computer-aided design/computer-aided manufacturing (CAD/CAM) system and to determine whether the effect of crystallization is clinically acceptable by comparing values of fit before and after the crystallization process. The mandibular right first molar was selected as the abutment for the experiments. Fifteen working models were prepared. Lithium disilicate crowns appropriate for each abutment were prepared using a commercial CAD/CAM system. Gaps in the marginal area and 4 internal areas of each crown were measured twice—before and after crystallization—using the silicone replica technique. The mean values of fit before and after crystallization were analyzed using a pairedt-test to examine whether the conversion that occurred during crystallization affected marginal and internal gaps (α=0.05). Gaps increased in the marginal area and decreased in the internal areas after crystallization. There were statistically significant differences in all of the investigated areas (P<0.05). None of the values for marginal and internal fit of lithium disilicate CAD/CAM crowns after crystallization exceeded 120μm, which is the clinically acceptable threshold.


Crystals ◽  
2021 ◽  
Vol 11 (2) ◽  
pp. 86
Author(s):  
Pa Pa Kay Khine ◽  
Antonin Tichy ◽  
Ahmed Abdou ◽  
Keiichi Hosaka ◽  
Yasunori Sumi ◽  
...  

Background: Repair bonding to lithium disilicate ceramic (LDS) remains an issue. This study examined whether the adaptation of a resin composite to LDS can be improved by a silane pretreatment and warm air-drying. Methods: LDS blocks (IPS e.max CAD) with prefabricated tapered cavities were bonded using a silane-containing universal adhesive (Clearfil Universal Bond Quick ER; UBQ) or the bonding agent of a two-step self-etch adhesive (Clearfil SE Bond 2), with and without a silane pretreatment (Clearfil Ceramic Primer; CP). CP and the adhesives were air-dried with normal air (23 ± 1 °C) or warm air (60 ± 5 °C), light-cured, and the cavities were filled with a flowable composite. Interfacial gap formation was evaluated using swept-source optical coherence tomography immediately after filling, after 24 h, 5000 and 10,000 thermal cycles, and an additional 1 year of water storage. Results: Without the silane pretreatment, all specimens soon detached from the cavities. Warm air-drying significantly decreased gap formation compared to normal air-dried groups (p < 0.001) and improved long-term stability (p < 0.001). The lowest gap formation was observed with UBQ when the silane pretreatment was combined with warm air-drying. Conclusions: Composite adaptation to LDS was insufficient without silanization, but it was stable in the long term if the silane pretreatment and warm air-drying were combined.


2021 ◽  
Author(s):  
CA Jurado ◽  
A Tsujimoto ◽  
H Watanabe ◽  
NG Fischer ◽  
JA Hasslen ◽  
...  

SUMMARY Objective: The purpose of this study was to evaluate the effectiveness of five different polishing systems on a computer-aided design and computer-aided manufacturing (CAD/CAM) polymer-infiltrated ceramic-network restoration with nanoscale assessment using atomic force microscopy (AFM) and visual assessment performed by dental school senior students and faculty members. Method: Forty-eight full coverage crowns were milled out of polymer-infiltrated ceramic-network CAD/CAM blocks (Vita Enamic) for polishing with one company proprietary, two ceramic and two composite polishing systems. The prepared crowns were divided into six groups: (1) no polishing (control); (2) polishing with Vita Enamic Polishing Kit (VEna); (3) polishing with Shofu Porcelain Laminate Polishing Kit (SCer); (4) polishing with Brasseler Dialite Feather lite All- Ceramic Adjusting & Polishing System (BCer); (5) polishing with Shofu Composite Polishing Kit (SCom); and (6) polishing with Brasseler Composite Polishing Kit (BCom). The polished crown surface topography was observed, and surface roughness and area were measured with AFM. In addition, polished crowns were visually assessed by 15 senior dental students and 15 dental school faculty members. Results: All polishing treatments significantly reduced the surface roughness and area of the crown compared with the control. SCom and BCom showed significantly higher surface area than VEna, and the SCer and BCer groups were intermediate, showing no significant difference from either VEna or SCom and BCom. There were no significant differences in surface roughness between any of the systems. Dental students and faculty members classified the groups polished with VEna, SCer, and BCer groups as clinically acceptable, and they selected BCer group as the best polished restorations and the control group as the least polished restorations. Conclusions: Ceramic and composite polishing systems produced similar polishing results as that observed using a company proprietary polishing system. However, effectiveness for polishing using a company proprietary and ceramic polishing system tends to be higher than composite polishing systems.


2019 ◽  
Vol 2 (1) ◽  
Author(s):  
Dwi Fitriyanti ◽  
Mardiyono Mardiyono ◽  
Yuriz Bakhtiar

Cervical cancer is the cancer that most often attacks women after breastcancer throughout the world. Around the world every two minutes or everyhour a woman dies from cervical cancer. Every patient newly diagnosed withcervical cancer needs to know information about cervical cancer that canaffect the patient's psychological changes in the form of depression. Thepurpose of this study was to determine the effectiveness of education withanimation media to reduce the depression level of cervical cancer patientswith early diagnosis. The method of this research is a pilot study(preliminary study) or testing the feasibility of animation video media on thelevel of depression. Respondent samples in the animated video media trialincluded 10 intervention samples and 10 control samples. The results of theanimation video media research are feasible to be used in subsequent studiesin cervical cancer patients with an initial diagnosis of depression. Dataanalysis using the Wilcoxon Sign Rank Test showed that there was asignificant difference in the level of depression before and after being giveneducation using the animation video media in the intervention group with avalue of p = 0.005 while in the control group with a value p = 0.102. Theconclusion of this study is that the animation video media is feasible to beused in subsequent studies and can effectively be given to cervical cancerpatients with an initial diagnosis of depression.


2014 ◽  
Vol 1 (2) ◽  
pp. 081-086
Author(s):  
Rendra Sukmana ◽  
Nawang Wulandari

Occupational therapy is a healing effort against someone who is experiencing mental and physical disorders by giving liveliness job. The purpose of the study to determine the effect of Occupational Therapy on social skills in schizophrenia with social isolation, using Quasy Control Group Pre-test Posttest Design. Sampel used in this experiments were 10 respondents that are divided into 2 groups: treatment and control. The treatment group was given occupational therapy 2 times a week for 3 weeks. Observations by 12 questions was conducted to determine the level of social skills of respondents. The results of this study showed no increase on the level of social skills before and after given granted Occupational Therapy. The level of social capability of 5 respondents in the treatment group before given an Occupational Therapy were 7 and while after given an occupational therapy were 10.2. This result have contrast to the control group which showed level of social capability were 7 . Statistic Analized using Wilcoxon Sign Rank Test showed significant is 0.0205 in the group between pre and post treatment, while the treatment and control group comparisons with Mann Whitney U test showed 0.029 ≤ 0.05. With these results Occupational Therapy can improve social skills clients with social isolation.


Sign in / Sign up

Export Citation Format

Share Document