scholarly journals Pengaruh pelapisan kitosan pada basis gigi tiruan resin akrilik polimerisasi panas terhadap penyerapan air dan kekuatan transversalThe effect of chitosan coating on the water absorption and transverse strength of heat polymerised acrylic resin

2021 ◽  
Vol 5 (1) ◽  
pp. 57
Author(s):  
Felycia Felycia ◽  
Slamat Tarigan
2019 ◽  
Vol S (1) ◽  
pp. 7-10
Author(s):  
Ahmed Asim Saeed Al-Ali ◽  
◽  
Ammar k. Al-Noori ◽  
Amer A. Taqa ◽  
◽  
...  

Objectives: Compare tensile and transverse strength of new copolymers for denture base. Materials and methods: The specimens were prepared from heat cured acrylic resin with three types of additives: Acryester B, Ethoxycarbonylethylene, and Propenoic acid at a percentage of 5% and 10%. The tensile and transverse strains were tested, recorded and compared. Results: The analysis of variance display statistically significant difference. The p-value was 0.001 for each of tensile and transverse strain tests. Conclusions: The tensile strength of the novel copolymers increased. The transverse strength of some of the novel copolymers increased.


2020 ◽  
Vol 32 (1) ◽  
pp. 66
Author(s):  
Siti Wahyuni ◽  
Chairunnisa Ricca

Pendahuluan: Nilon termoplastik merupakan basis gigi tiruan yang banyak diminati oleh para dokter gigi karena memiliki beberapa keuntungan dibandingkan bahan basis gigi tiruan resin akrilik. Diantara jenis nilon termoplastik yang sering dijadikan basis gigi tiruan adalah poliamida 6 dan poliamida mikrokristalin. Poliamida Mikrokristalin merupakan poliamida generasi baru yang dibuat untuk menanggulangi kelemahan pada poliamida sebelumnya. Tujuan penelitian ini adalah menganalisis pengaruh minuman teh pada pengguna gigi tiruan nilon termoplastik terhadap penyerapan air dan stabilitas warna. Metode: Jenis penelitian ini adalah experimental laboratoris. Jumlah sampel terdiri dari 40 dengan  ukuran diameter 15 mm ± 1 mm dan ketebalan 0.5 mm ± 0,1 mm (ISO 4049) dan terbagi menjadi 4 kelompok (kelompok A poliamida 6 dan kelompok B poliamida mikrokristalin untuk penyerapan air serta kelompok C poliamida 6 dan kelompok D poliamida mikrokristalin untuk uji stabilitas warna). Semua sampel direndam dalam larutan teh selama 7 hari. Data dianalisis dengan uji T Independen. Gambaran mikroskopis sampel diuji dengan SEM Hasil: Berdasarkan uji T Independen hasil menunjukkan perbedaan yang signifikan diantara kelompok A dan B, C dan D.  Uji T independen menunjukkan perbedaan yang signifikan diantara kelompok A dan B, C dan D (p=0,0001, p<0,05) Simpulan: Terdapat pengaruh minuman teh pada pengguna gigi tiruan nilon termoplastik. Poliamida Mikrokristalin memiliki penyerapan air yang lebih sedikit dan stabilitas warna yang lebih baik dibandingkan Poliamida 6.Kata kunci: Nilon termoplastik, poliamida 6, poliamida mikrokristalin, penyerapan air, stabilitas warna, SEM. ABSTRACTIntroduction: Thermoplastic nylon is a denture base mostly demanded by dentists due to its several advantages over acrylic resin denture base material. Among the types of thermoplastic nylon that are often used as denture bases are polyamide 6 and microcrystalline polyamide. Microcrystalline polyamide is the new generation of polyamides created to overcome the weaknesses of previous polyamides. The purpose of this study was to analyse the effect of tea on thermoplastic nylon denture wearers on water absorption and colour stability. Methods: This research was experimental laboratory research on 40 samples with a diameter of 15 mm ± 1 mm, and a thickness of 0.5 mm ± 0.1 mm (ISO 4049), divided into four groups (Group A was the polyamide 6; Group B was the microcrystalline polyamide on the water absorption; Group C was polyamide 6; and Group D was microcrystalline polyamide on the colour stability). All samples were immersed in the tea solutions for 7 days. Data were analysed with independent t-test. The microscopic structure was analysed using the scanning electron microscope (SEM). Results: The results showed significant differences between group A, B, C, and D. The independent t-test also showed significant differences between group A, B, C, and D (p = 0.000; p < 0.05). Conclusion: There is an effect of tea on the thermoplastic nylon denture wearers. Microcrystalline polyamides have less water absorption and better colour stability than Polyamide 6.Keywords:  Polyamide 6, thermoplastic nylon, microcrystalline polyamide, water absorption, colour stability, SEM.


2019 ◽  
Vol 10 (2) ◽  
pp. 1464-1469
Author(s):  
Adnan R. Al Assal ◽  
Abdalbaset A Fatalla ◽  
Mohammed Moudhaffar ◽  
Ghasak H Jani

The general upgrading of polymer denture base material and research continuously looking for ideal restorative dental material with better properties, adequate esthetic properties, less expensive and easier to handle material to develop photo polymerization dental materials. This study was conducted to evaluate the effect of addition polyamide on mechanical microparticle properties light cure denture base material. One hindered sixty specimens from light-cured acrylic resin (Aurora). The divided mainly into four groups according to test used (Transverse strength test, impact strength test, hardness test and tensile strength test) with 40 specimens for each group. The results show an increase in Transverse strength, impact strength, hardness and tensile strength in all experimental group when compared to control group the highest mean values for all tests included in the study appeared in group B 1% polyamide. The addition of polyamide microparticle improves transverse, tensile, impact strength and hardness properties of denture base material.


2021 ◽  
Vol 4 (3) ◽  
pp. 131
Author(s):  
Sujati Sujati

Background: In acrylic removable dentures, brokenness often occurs in the midline region of the maxilla. Resistance to fracture depends on the physical properties of the material namely the transverse strength. This can be prevented by the addition of glass fibers. Tea is consumed by many people, acrylic resin dipped in steeping tea will reduce the strength of acrylic resin. How the physical properties of acrylic resin are modified by the addition of glass fiber effect when immersed in a tea solution. Purpose: This study was to determine the strength of transverse acrylic resin with the addition of glass fibers soaked in tea. Method: Rectangular acrylic resin with a size of 10 x 65 x 2.5 mm. The number of samples is 24. divided into 4 groups. namely 2 groups without glass fiber and 2 groups with glass fiber. The sample is measured by transverse strength using an autograph (Shimadzu) tool, then data is analyzed using ANOVA. Result: Acrylic resin without glass fiber immersed in tea solution decreases its transverse strength. while the acrylic resin was given glass fiber the strength value of the transversion does not differ significantly either soaked or not. Conclusion: Acrylic resin which is given glass fiber and soaked in tea does not reduce the strength of the transversion. This is due to the glass fiber filling the cavity in the acrylic resin.


2017 ◽  
Vol 29 (3) ◽  
Author(s):  
Eni Rahmi ◽  
Zulkarnain Agus ◽  
Riezka Hanafiah Putri

Introduction: Heat-polymerized acrylic resin is the most basic denture material used. One of the mechanical properties of an acrylic resin is its transverse strength. The transverse strength test provides an overview of the material’s durability in accepting the load at mastication. Consumption of tea, especially black tea in the world placed the second most consumed. The purpose of this study was to determine the effect of black tea on the transverse strength of heat-polymerized acrylic resin. Methods: This research was an experimental laboratory with 24 samples of heat-polymerized acrylic resin plate with the size of 65x10x2.5 mm. The sample was divided into 6 groups, each consisted of 4 samples. The first, second, and the third groups were immersed in aquadest for consecutively 1, 4, and 20 days. The fourth, fifth, and sixth groups were immersed in the black tea for consecutively 1, 4, and 20 days. The transverse strength was tested using the three-point bending method with the Universal Testing Machine. The results of the transverse strength measurement were then analyzed statistically by the One-way ANOVA test and Holm’s sequential Bonferroni posthoc test as an advanced test. Results: The results of the statistical test showed that p<0.05 (p=0.000) which means that the six groups have a significant difference in the average value of the transverse strength. Conclusion: The conclusion of this research was the black tea immersion duration was affecting the transverse strength differences of the heat-polymerized acrylic resin.


2015 ◽  
Vol 1 (1) ◽  
pp. 102
Author(s):  
Pramudya Aditama ◽  
Siti Sunarintyas ◽  
Widjijono Widjijono

Resin akrilik merupakan bahan yang sering digunakan dalam pembuatan basis gigi tiruan. Kelemahan resin akrilik adalah mudah patah. Salah satu cara untuk mengatasi masalah tersebut adalah dengan menambahkan polyethylene (PE) atau glass fiber. Tujuan dari penelitian ini untuk mengetahui pengaruh jenis dan volumetrik fiber terhadap kekuatan transversal reparasi plat resin akrilik. Penelitian ini menggunakan dua puluh lima plat resin akrilik kuring panas berukuran 65 x 10 x 2,5 mm. Subjek dipreparasi untuk membuat jarak 3 mm dan sudut bevel 45o. Subjek dibagi menjadi 5 kelompok, masingmasing kelompok terdiri dari 5 subjek. Kelompok 1 (kontrol) tanpa penambahan fiber, kelompok II dengan penambahan 3,7% v/v PE fiber, kelompok III dengan penambahan 7,4% v/v PE fiber, kelompok IV dengan penambahan 3,7% v/v E-glass fiber, dan kelompok V dengan penambahan 7,4% v/v E-glass fiber. Seluruh plat direndam dalam air destilasi selama satu hari pada suhu 37oC. Pengujian kekuatan transversal plat resin akrilik dengan menggunakan Universal Testing Machine dan data yang didapat dianalisis menggunakan ANAVA dua jalur dengan tingkat kepercayaan 95%. Rerata kekuatan transversal (MPa) reparasi plat resin akrilik yang diperkuat fiber: 3,7% v/v PE fiber (67,77±3,34); 7,4% v/v PE fiber (80,37±8,42); 3,7% v/v E-glass fiber (96,72±5,43); 7,4% v/v E-glass fiber (109,44±4,98); sedangkan reparasi plat resin yang tidak diperkuat fiber menghasilkan kekuatan transversal 56,27±4,7 MPa. Hasil analisis menggunakanANAVA dua jalur menunjukkan variabel jenis dan volumetrik fiber memberikan pengaruh signifikan (p<0,05), sedangkan interaksi antara jenis dan volumetrik fiber tidak berpengaruh signifikan (p>0,05). Uji post hoc Tukey menunjukkan perbedaan signifikan (p<0,05) untuk seluruh kelompok perlakuan. Penambahan E-glass fiber dalam reparasi plat resinakrilik mampu meningkatkan kekuatan transversal lebih tinggi dibandingkan dengan menggunakan PE fiber. Peningkatan volumetrik fiber dapat meningkatkan kekuatan transversal reparasi plat resin akrilik. Effect Of Type And Volumetric Fiber On Transverse Strength Of Acrylic Resin Plate Repair. Acrylic resin is the most common denture base material. A disadvantage of acrylic resin is that it is easily fractured. One way to resolve this problem is by adding polyethylene (PE) or glass fibers. The purpose of this research is to find out about the effect of type and volumetric fiber on transverse strength of acrylic resin plate repaired. The experiment involved twenty five plates of heat cured acrylic with the dimensions of 65 x 10 x 2.5 mm. The speciments were prepared to create a 3 mm gap and 45° bevel. The subjects were divided into 5 groups; each group consisted of 5. Group I (control) was without fiber reinforcement, group II reinforced with 3.7% v/v PE fiber, group III reinforced with 7.4% v/v PE fiber, group IV reinforced with 3.7% v/v E-glass fiber, and group V reinforced with 7.4% v/v E-glass fiber. All plates were soaked in distilled water for one day at 37° C temperature. The plates were tested for transverse strength with Universal Testing Machine and all data obtained were analyzed with two way ANOVA at 95% confidence level. The mean of transverse strength (MPa) of the acrylic resin plate repair reinforced with fiber: 3.7% v/v PE fiber was (67.77±3.34); 7.4% v/v PE fiber (80.37±8.42); 3.7% v/v E-glass fiber (96.72±5.43); 7.4% v/v E-glass fiber (109.44±4.98); while the transverse strength of the acrylic resin plate with no fiber reinforced was 56.27±4.7 MPa. Two way ANOVA analysis shows that type and volumetric fiber had significant effect (p<0.05), while the interaction between type and volumetric fiber had no significant effect (p>0.05). Tukey post hoc test shows significant difference (p<0.05) for all groups. The addition of E-glass fibers in the acrylic resin plate repaired increased the transverse strength higher than that with PE fibers. The increase in volumetric fibers might improve the transverse strength of the acrylic resin plate repaired.


2017 ◽  
Vol 1 ◽  
Author(s):  
Annisa Mayang Rusdi ◽  
Lasminda Syafiar ◽  
Astrid Yudhit

<p class="AbstractContent"><strong>Objective:</strong> The purpose of this study was to evaluate transverse strength of heat cured acrylic resin after immersed in 0,2% chlorhexidine gluconate mouthwash for 15, 30, 45, and 60 minutes.</p><p class="AbstractContent"><strong>Methods:</strong> This was an experimental laboratory study with posttest only group design. The samples were heat cured acrylic resin plate with size 65mm x 10mm x 2,5mm. Polymerization of the heat cured acrylic was done by water bath (74 °C for 2hrs followed by 100 °C for 1hr). Totally 30 samples were prepared and divided into 5 groups (n=6) which are group I as control, and others were immersed in 0, 2% chlorhexidine gluconate, group II (15 minutes), group III (30 minutes), group IV (45 minutes) and group V (60 minutes) respectively. The transverse strength was test using Torsee’s Universal Testing machine, Japan with crosshead 1/10 mm/seconds. The data was statistically analyzed using one way ANOVA (p≤0,005).</p><p class="AbstractContent"><strong>Results:</strong> Means and Standard deviation of Transverse strength were 92.382±11.786 N/mm2, 92.186±13.349 N/mm2,92.578±12.492 N/mm2, 92.382±13.939 N/mm2, and 91.989±12.285 N/mm2 for group I, II, III, IV, and V respectively. Statistic analyzed showed no significant difference among groups with p value= 1,000 (p &lt; 0, 05).</p><p class="AbstractContent"><strong>Conclusion:</strong> The immersion in 0, 2% chlorhexidine gluconate mouthwash at different period does not changed transverse strength of heat cured acrylic resin.</p>


Sign in / Sign up

Export Citation Format

Share Document