scholarly journals Effect of black tea on the transverse strength of heat-polymerized acrylic resin

2017 ◽  
Vol 29 (3) ◽  
Author(s):  
Eni Rahmi ◽  
Zulkarnain Agus ◽  
Riezka Hanafiah Putri

Introduction: Heat-polymerized acrylic resin is the most basic denture material used. One of the mechanical properties of an acrylic resin is its transverse strength. The transverse strength test provides an overview of the material’s durability in accepting the load at mastication. Consumption of tea, especially black tea in the world placed the second most consumed. The purpose of this study was to determine the effect of black tea on the transverse strength of heat-polymerized acrylic resin. Methods: This research was an experimental laboratory with 24 samples of heat-polymerized acrylic resin plate with the size of 65x10x2.5 mm. The sample was divided into 6 groups, each consisted of 4 samples. The first, second, and the third groups were immersed in aquadest for consecutively 1, 4, and 20 days. The fourth, fifth, and sixth groups were immersed in the black tea for consecutively 1, 4, and 20 days. The transverse strength was tested using the three-point bending method with the Universal Testing Machine. The results of the transverse strength measurement were then analyzed statistically by the One-way ANOVA test and Holm’s sequential Bonferroni posthoc test as an advanced test. Results: The results of the statistical test showed that p<0.05 (p=0.000) which means that the six groups have a significant difference in the average value of the transverse strength. Conclusion: The conclusion of this research was the black tea immersion duration was affecting the transverse strength differences of the heat-polymerized acrylic resin.

2015 ◽  
Vol 1 (1) ◽  
pp. 102
Author(s):  
Pramudya Aditama ◽  
Siti Sunarintyas ◽  
Widjijono Widjijono

Resin akrilik merupakan bahan yang sering digunakan dalam pembuatan basis gigi tiruan. Kelemahan resin akrilik adalah mudah patah. Salah satu cara untuk mengatasi masalah tersebut adalah dengan menambahkan polyethylene (PE) atau glass fiber. Tujuan dari penelitian ini untuk mengetahui pengaruh jenis dan volumetrik fiber terhadap kekuatan transversal reparasi plat resin akrilik. Penelitian ini menggunakan dua puluh lima plat resin akrilik kuring panas berukuran 65 x 10 x 2,5 mm. Subjek dipreparasi untuk membuat jarak 3 mm dan sudut bevel 45o. Subjek dibagi menjadi 5 kelompok, masingmasing kelompok terdiri dari 5 subjek. Kelompok 1 (kontrol) tanpa penambahan fiber, kelompok II dengan penambahan 3,7% v/v PE fiber, kelompok III dengan penambahan 7,4% v/v PE fiber, kelompok IV dengan penambahan 3,7% v/v E-glass fiber, dan kelompok V dengan penambahan 7,4% v/v E-glass fiber. Seluruh plat direndam dalam air destilasi selama satu hari pada suhu 37oC. Pengujian kekuatan transversal plat resin akrilik dengan menggunakan Universal Testing Machine dan data yang didapat dianalisis menggunakan ANAVA dua jalur dengan tingkat kepercayaan 95%. Rerata kekuatan transversal (MPa) reparasi plat resin akrilik yang diperkuat fiber: 3,7% v/v PE fiber (67,77±3,34); 7,4% v/v PE fiber (80,37±8,42); 3,7% v/v E-glass fiber (96,72±5,43); 7,4% v/v E-glass fiber (109,44±4,98); sedangkan reparasi plat resin yang tidak diperkuat fiber menghasilkan kekuatan transversal 56,27±4,7 MPa. Hasil analisis menggunakanANAVA dua jalur menunjukkan variabel jenis dan volumetrik fiber memberikan pengaruh signifikan (p<0,05), sedangkan interaksi antara jenis dan volumetrik fiber tidak berpengaruh signifikan (p>0,05). Uji post hoc Tukey menunjukkan perbedaan signifikan (p<0,05) untuk seluruh kelompok perlakuan. Penambahan E-glass fiber dalam reparasi plat resinakrilik mampu meningkatkan kekuatan transversal lebih tinggi dibandingkan dengan menggunakan PE fiber. Peningkatan volumetrik fiber dapat meningkatkan kekuatan transversal reparasi plat resin akrilik. Effect Of Type And Volumetric Fiber On Transverse Strength Of Acrylic Resin Plate Repair. Acrylic resin is the most common denture base material. A disadvantage of acrylic resin is that it is easily fractured. One way to resolve this problem is by adding polyethylene (PE) or glass fibers. The purpose of this research is to find out about the effect of type and volumetric fiber on transverse strength of acrylic resin plate repaired. The experiment involved twenty five plates of heat cured acrylic with the dimensions of 65 x 10 x 2.5 mm. The speciments were prepared to create a 3 mm gap and 45° bevel. The subjects were divided into 5 groups; each group consisted of 5. Group I (control) was without fiber reinforcement, group II reinforced with 3.7% v/v PE fiber, group III reinforced with 7.4% v/v PE fiber, group IV reinforced with 3.7% v/v E-glass fiber, and group V reinforced with 7.4% v/v E-glass fiber. All plates were soaked in distilled water for one day at 37° C temperature. The plates were tested for transverse strength with Universal Testing Machine and all data obtained were analyzed with two way ANOVA at 95% confidence level. The mean of transverse strength (MPa) of the acrylic resin plate repair reinforced with fiber: 3.7% v/v PE fiber was (67.77±3.34); 7.4% v/v PE fiber (80.37±8.42); 3.7% v/v E-glass fiber (96.72±5.43); 7.4% v/v E-glass fiber (109.44±4.98); while the transverse strength of the acrylic resin plate with no fiber reinforced was 56.27±4.7 MPa. Two way ANOVA analysis shows that type and volumetric fiber had significant effect (p<0.05), while the interaction between type and volumetric fiber had no significant effect (p>0.05). Tukey post hoc test shows significant difference (p<0.05) for all groups. The addition of E-glass fibers in the acrylic resin plate repaired increased the transverse strength higher than that with PE fibers. The increase in volumetric fibers might improve the transverse strength of the acrylic resin plate repaired.


2017 ◽  
Vol 1 ◽  
Author(s):  
Annisa Mayang Rusdi ◽  
Lasminda Syafiar ◽  
Astrid Yudhit

<p class="AbstractContent"><strong>Objective:</strong> The purpose of this study was to evaluate transverse strength of heat cured acrylic resin after immersed in 0,2% chlorhexidine gluconate mouthwash for 15, 30, 45, and 60 minutes.</p><p class="AbstractContent"><strong>Methods:</strong> This was an experimental laboratory study with posttest only group design. The samples were heat cured acrylic resin plate with size 65mm x 10mm x 2,5mm. Polymerization of the heat cured acrylic was done by water bath (74 °C for 2hrs followed by 100 °C for 1hr). Totally 30 samples were prepared and divided into 5 groups (n=6) which are group I as control, and others were immersed in 0, 2% chlorhexidine gluconate, group II (15 minutes), group III (30 minutes), group IV (45 minutes) and group V (60 minutes) respectively. The transverse strength was test using Torsee’s Universal Testing machine, Japan with crosshead 1/10 mm/seconds. The data was statistically analyzed using one way ANOVA (p≤0,005).</p><p class="AbstractContent"><strong>Results:</strong> Means and Standard deviation of Transverse strength were 92.382±11.786 N/mm2, 92.186±13.349 N/mm2,92.578±12.492 N/mm2, 92.382±13.939 N/mm2, and 91.989±12.285 N/mm2 for group I, II, III, IV, and V respectively. Statistic analyzed showed no significant difference among groups with p value= 1,000 (p &lt; 0, 05).</p><p class="AbstractContent"><strong>Conclusion:</strong> The immersion in 0, 2% chlorhexidine gluconate mouthwash at different period does not changed transverse strength of heat cured acrylic resin.</p>


2015 ◽  
Vol 3 (2) ◽  
pp. 68-73
Author(s):  
Riezka Hanafiah Putri ◽  
Zulkarnain Agus ◽  
Eni Rahmi

Heat-polymerized  acrylic  resins  is  the  most  used  denture  base  material  in  prosthodontics.  One  of  mechanical properties of acrylic resins is transverse strength. It represents the masticatory pressure that is applied to denture base. Black tea is the second largest consumed beverage in the world. The aim of this study was to investigate the effect of black tea beverage on transverse strength of heat-polymerized acrylic resins. A total of 24 heat-polymerized acrylic resin plates (65×10×2,5 mm) were immersed in black tea beverage for 1, 4, and 20 days as treatment group and in aquadest for 1, 4, and 20 days as control group. The transverse strength of  acrylic samples were measured by three–point bending test by universal testing machine. Data were statistically analyzed using Independent t test. The transverse strength values of acrylic resin immersed in black tea beverage had no significant differences to the transverse strength values of acrylic resin immersed in aquadest with similar immersion time (p>0,05). There was no effect of black tea beverage on transverse strength of heat-polymerized acrylic resins. Immersion time decrease the transverse strength of heat-polymerized acrylic resins due to water sorption. Keywords: Heat-polymerized acrylic resins, black tea, transverse strength


2018 ◽  
Vol 30 (1) ◽  
pp. 35 ◽  
Author(s):  
Edwin Tandra ◽  
Endang Wahyuningtyas ◽  
Erwan Sugiatno

Introduction: Acrylic resin is still the most commonly used denture base material due to its ideal properties. However, acrylic resin denture fractures are still considered a major unsolved problem thus the addition of nanoparticles as filler was performed to increase its mechanical properties. The purpose of this study was to discovered the effect of nanoparticles TiO2 on the flexural strength of acrylic resin denture plate. Method: This study used 27 heat-cured acrylic resin specimens sized 65 x 10 x 2.5 mm. The samples were divided into three concentration groups (n = 9), the control group; 1% of nanoparticles TiO2; and 3% of nanoparticles TiO2. The flexural strength was tested using the Universal Testing Machine. All data were analysed using the one-way ANOVA test with 95% confidence level then continued with the Least Significant Difference (LSD) test. Results: There were significant flexural strength differences in different concentration of nanoparticles TiO2. The highest flexural strength value was found in the 1% of nanoparticles TiO2 group (106.99 ± 6.09 MPa), whilst the lowest flexural strength value was found in the 3% of nanoparticles TiO2 group (91.64 ± 5.38 MPa). Significant flexural strength difference was found between the control group and the 1% of nanoparticles TiO2 group, and also between the 1% of nanoparticles TiO2 group with the 3% of nanoparticles TiO2 group (p < 0.05). Conclusion: From this study can be concluded that concentration of 1% of nanoparticles TiO2 was able to increase the flexural strength of acrylic resin denture plate.


2017 ◽  
Vol 2 (1) ◽  
pp. 40
Author(s):  
Pramudya Aditama ◽  
Erwan Sugiatno ◽  
Muhamad Rifqi Tri Nuryanto

The effect of e-glass fiber volumetric on transverse strength of an acrylic resin denture plate repair. Acrylic resin is the most commonly material for the denture base. A disadvantage of acrylic resin is that it is easily to be cracked. One of the ways to resolve this problem is by adding the E-glass fibers. The purpose of this research was to find out the effect of volumetric E-glass fiber on transverse strength of an acrylic resin denture plate repair. The experiment involved thirty plates of heat cured acrylic with the dimensions of 65 × 10 × 2.5 mm. The specimens were prepared to create a 3-mm gap and 45° bevel. Subjects were divided in to 3 groups, each of which contained 10. Group I (control) was with no fiber reinforcement, group II was reinforced with 3.7vol % E-glass fiber, and group III was reinforced with 7.4 volume % E-glass fiber. All plates were soaked in distillation water for one day at 37 °C. Plates were tested for transverse strength with Universal Testing Machine and all data obtained was analyzed with one way anova at 95% confidence level (α= 0.05). The significant difference was found between the transversal force of acrylic resin plat enforced with fiber and other group without being reinforced with fibers (p<0.05). Group reinforced with 7.4 vol % E-glass fibers showed a significant difference (higher) than the group reinforced with 3.7 volume % fibers. The addition of E-glass fibers in an acrylic resin plate repair material increased the transverse strength. The increase in volumetric fibers might improve the transverse strength of an acrylic resin plate repair material.ABSTRAKResin akrilik merupakan bahan yang sering digunakan dalam pembuatan basis gigi tiruan. Kekurangan dari bahan resin akrilik adalah mudah patah. Salah satu cara yang dapat digunakan untuk mengatasi masalah tersebut adalah dengan menambahkan E-glass fiber. Tujuan untuk mengetahui pengaruh volumetrik E-glass fiber terhadap kekuatan transversal reparasi plat gigi tiruan resin akrilik. Penelitian ini menggunakan tiga puluh plat resin akrilik kuring panas dengan ukuran 65 × 10 × 2,5 mm. Spesimen dipreparasi untuk membentuk jarak 3 mm dan sudut bevel 45°. Subjek kemudian dibagi menjadi 3 kelompok, setiap kelompok terdiri dari 10 plat. Kelompok I (kontrol) tanpa diberikan penguat fiber, kelompok II diperkuat dengan 3,7 vol % E-glass  ber, dan kelompok III diperkuat dengan 7,4 vol % E-glass fiber. Seluruh plat kemudian direndam dalam air destilasi selama satu hari pada suhu 37 °C. Plat resin akrilik kemudian diuji menggunakan Universal Testing Machine untuk mengetahui kekuatan transversal dan data yang didapatkan dianalisis menggunakan Anova satu jalur dengan tingkat kepercayaan 95% (α=0,05). Hasil menunjukkan terdapat perbedaan signifikan antara kekuatan transversal plat resin akrilik yang diperkuat dengan fiber dengan kelompok tanpa diperkuat fiber (p < 0,05). Kelompok yang diperkuat dengan 7,4 vol % E-glass fiber menunjukkan perbedaan signi kan (lebih tinggi) dibandingkan kelompok yang diperkuat dengan 3,7 vol % fiber. Kesimpulan bahwa peningkatan volume dari E-glass fiber dapat meningkatkan kekuatan transversal reparasi plat gigi tiruan resin akrilik.


2014 ◽  
Vol 08 (04) ◽  
pp. 498-503 ◽  
Author(s):  
Lucas da Fonseca Roberti Garcia ◽  
Hebert Luis Rossetto ◽  
Fernanda de Carvalho Panzeri Pires-de-Souza

ABSTRACT Objective: To evaluate the shear bond strength of a novel calcium aluminate-based cement, EndoBinder (EB), to dentine in comparison with Grey and White Mineral Trioxide Aggregate (MTA). Materials and Methods: Root canal hemi-sections obtained from 30 extracted molar teeth were embedded in self-polymerized acrylic resin and were grounded wet in order to obtain a flat dentine surface. Next, the roots were randomly assigned into three groups (n = 10), according to the cement used, as follows: EB: EndoBinder; WMTA: White MTA and GMTA: Grey MTA. The shear bond strength test was performed using a Universal Testing Machine (0.5 mm/min) and the data were submitted to statistical analysis (1-way ANOVA and Tukey tests, P < 0.05). Results: EB presented the highest shear bond strength values; however, there was no statistically significant difference in comparison with GMTA (P > 0.05). WMTA presented the lowest mean values, which were significant in comparison with EB (P < 0.05). Conclusions: The novel calcium aluminate-based cement presented higher shear bond strength than WMTA, and should be considered as a promising alternative in endodontic therapy.


2015 ◽  
Vol 26 (3) ◽  
pp. 258-262 ◽  
Author(s):  
Renato Sussumu Nishioka ◽  
Luis Gustavo Oliveira de Vasconcellos ◽  
Renata Pilli Jóias ◽  
Sigmar de Mello Rode

In view of the low loading values commonly employed in dentistry, a load-application device (LAD) was developed as option to the universal testing machine (UTM), using strain gauge analysis. The aim of this study was to develop a load-application device (LAD) and compare the LAD with the UTM apparatus under axial and non-axial loads. An external hexagonal implant was inserted into a polyurethane block and one EsthetiCone abutment was connected to the implant. A plastic prosthetic cylinder was screwed onto the abutment and a conical pattern crown was fabricated using acrylic resin. An impression was made and ten identical standard acrylic resin patterns were obtained from the crown impression, which were cast in nickel-chromium alloy (n=10). Four strain gauges were bonded diametrically around the implant. The specimens were subjected to central (C) and lateral (L) axial loads of 30 kgf, on both devices: G1: LAD/C; G2: LAD/L; G3: UTM/C; G4: UTM/L. The data (με) were statistically analyzed by repeated measures ANOVA and Tukey's test (p<0.05). No statistically significant difference was found between the UTM and LAD devices, regardless of the type of load. It was concluded that the LAD is a reliable alternative, which induces microstrains to implants similar to those obtained with the UTM.


2017 ◽  
Vol 1 (1) ◽  
Author(s):  
Dita Yulianda

This article will describe learning to write auotobiografi text using Contextual Teaching and Learning approach. The method used in the research, namely the experiment with the design of One-Group Pretest-Postest. Technique of collecting data in the form of test, observation, and questionnaire. The population in the study of students of class XI SMK Nurul Islam Cianjur, with a sample of 22 students. From the results of the study known the average value of the initial test 60.45 and the average value of the final test 80.91. The result of calculation with t-test known value that is 11,41 and value for t.s 0,05 value t = 1,72 and for t.s 0,01 value t = 2.51. Thus, there is a significant difference between students' ability in learning to write autobiographic text before and after using Contextual Teaching and Learning approach. The difference seen in the final test results is higher than the initial test results. The use of Contextual Teaching and Learning approach also get positive response for students, this can be proved by the percentage of student answers for positive response is greater than negative response, that is 30% of students who choose strongly agree (SS)> 4% of students who choose strongly disagree (STS).Keywords: autobiographic text, contextual


2020 ◽  
Vol 6 (2) ◽  
pp. 137-145
Author(s):  
Lukmanul Hakim

Abstrak: Ketepatan umpan (passing) merupakan salah satu hal yang sangat penting dalam permainan sepak bola. Banyak metode ataupun cara yang bisa dilakukan untuk melatih dan mengasah kemampuan seseorang untuk meningkatkan kualitas passing pada pemain sepak bola. Penelitian ini memiliki tujuan untuk mengetahui pengaruh latihan small side game terhadap keterampilan passing siswa SMP Plus Nurul Huda dalam ekstrakurikuler sepak bola tahun ajaran 2020. Penelitian ini merupakan penelitian eksperimen dengan menggunakan desain One-Group Pretest-posttest Design.Populasi pada penelitian ini adalah siswa ekstrakurikuler sepak bola.Sampel yang digunakan yaitu purposive sampling, dengan syarat bahwa subjek yang digunakan adalah siswa SMP Plus Nurul Huda kelas VII dan VIII yang mengikuti kegiatan ekstrakurikuler. Jumlah sampel pada penelitian ini berjumlah 16 orang.Hasil penelitian menunjukan pada nilai rata-rata yang diperoleh ketika melakukan tes awal adalah 17,38 dengan simpangan baku 1,82. Sedangkan untuk nilai tes akhir adalah rata-rata 25,94 dengan simpangan baku 1,87. Hasil uji-t memperoleh nilai t-hitung > t-tabel(20,990 > 2,13), maka Ho di tolak dan Ha diterima. Dengan demikian dapat disimpulkan bahwa terdapat pengaruh latihan small side game terhadap keterampilan passing siswa SMP Plus Nurul Huda dalam ekstrakurikuler sepak bola tahun ajaran 2020. Kata kunci :small side game, passing   Abstract: The accuracy of the pass (passing) is one of the most important things in soccer. There are many methods or ways that can be done to train and hone one's skills to improve the quality of passing on soccer players. This study aims to determine the effect of small side game training on the passing skills of SMP Plus Nurul Huda students in soccer extracurricular activities for the 2020 academic year.This research is an experimental study using the One-Group Pretest-posttest Design. The population in this study were soccer extracurricular students. The sample used was purposive sampling, with the condition that the subjects used were students of SMP Plus Nurul Huda class VII and VIII who participated in extracurricular activities. The number of samples in this study amounted to 16 people.The results showed that the average value obtained when conducting the initial test was 17.38 with a standard deviation of 1.82. As for the final test score is an average of 25.94 with a standard deviation of 1.87. The t-test results obtained the value of t-count> t-table (20.990> 2.13), then Ho was rejected and Ha was accepted. Thus it can be concluded that there is an effect of small side game training on the passing skills of SMP Plus Nurul Huda students in the football extracurricular activities for the 2020 academic year. Key words: small side game, passing


2019 ◽  
Vol S (1) ◽  
pp. 7-10
Author(s):  
Ahmed Asim Saeed Al-Ali ◽  
◽  
Ammar k. Al-Noori ◽  
Amer A. Taqa ◽  
◽  
...  

Objectives: Compare tensile and transverse strength of new copolymers for denture base. Materials and methods: The specimens were prepared from heat cured acrylic resin with three types of additives: Acryester B, Ethoxycarbonylethylene, and Propenoic acid at a percentage of 5% and 10%. The tensile and transverse strains were tested, recorded and compared. Results: The analysis of variance display statistically significant difference. The p-value was 0.001 for each of tensile and transverse strain tests. Conclusions: The tensile strength of the novel copolymers increased. The transverse strength of some of the novel copolymers increased.


Sign in / Sign up

Export Citation Format

Share Document