scholarly journals Mechanisms of Biological Processes in Domestic Wastewater Treatment Plants

2018 ◽  
Vol 28 (3) ◽  
pp. 177-192
Author(s):  
Sylwia Myszograj

Abstract The growing demand for solutions of household sewage treatment plants means that many new or improved technological solutions are available on the market. The implementation of these technologies is associated with the need to known the mechanisms of the unitary biological processes occurring when removing organic carbon, nitrogen and phosphorus from wastewater. Determining the optimal conditions for these processes will determine the correct operation of the household sewage treatment plant.

2020 ◽  
Vol 5 (2) ◽  
pp. 53-57
Author(s):  
Nandini Moondra ◽  
Namrata D Jariwala ◽  
Robin A Christian

Conventional domestic wastewater treatment in most developing countries is confined to secondary treatments, mainly focusing on solids and organics removal, which results in eutrophication when the effluents are discharged into receiving bodies. Thus, to resolve the issues associated with the conventional treatment system, in the present study, microalgae was introduced in the primary treated effluent collected from a sewage treatment plant to study the efficiency of the system in reducing eutrophication and other challenges of secondary treatment. Phycoremediation is an effective and eco-friendly treatment alternative that reduced the primary-treated effluent’s PO4-P, NH3-N and COD concentration to 97.89%, 98.81%, and 88.24%, respectively at the identical HRT practiced for secondary treatment. One-way ANOVA was also conducted to determine the effectiveness of the system statistically. The experimental and statistical analysis proved that microalgal treatment could resolve the challenges of conventional secondary treatments if adopted for domestic wastewater.


Author(s):  
Narendra Pal Gole

The implementation of wastewater treatment plants has been a challenge for most countries. Economic resources, political will, institutional strength, and cultural background are important factors that define the trajectory of pollution control in many countries. Technology is sometimes mentioned as one of the reasons hindering further development. Therefore, a key objective of this research is to evaluate the performance of a plant based on the 345 MLD Upflow Anaerobic Sludge Blanket (UASB) technology by analyzing the physical and chemical parameters of the water treated by UASB to evaluate the performance of the plant located. at Bharwara Tech from Gomti Nagar Lucknow. In this study, the performance of the wastewater treatment plant and the UASB reactor was calculated. Wastewater is mixed with domestic wastewater, so the concentration of BOD and COD is relatively low. The amount of biogas produced by the UASB reactor is also less than its design value. All STP inlet and outlet water concentration results are displayed graphically.


2017 ◽  
Vol 1 (2) ◽  
pp. 99-108
Author(s):  
Daniel Wicaksono ◽  
Agus Slamet

Kenjeran is one of district in Surabaya with high risk sanitation based on EHRA Surabaya 2012. Kenjeran has 4 (four) sub districts consist of Bulak Banteng, Tanah Kali Kedinding, Sidotopo Wetan and Tambak Wedi. Bulak Banteng, Tanah Kali Kedinding and Tambak Wedi in Kenjeran District has identified as areas where open defecation still happened. The research is descriptive study using field survey, interview, and comparation existing condition with standarts and regulations. The technical aspect study is conducted by analyzing the needs of wastewater infrastructure facilities based on the volume domestic wastewater. 80 (eighty) Communal Sewage Treatment Plant (STP) were designed to solve domestic wastewater handling in 4 (four) subdistrict. Each of 80 (eighty) STP designed to cover 75 – 100 households. The domestic wastewater treatment plant using Anaerobic Baffled Reactor Technology. An example of design STP conducted in Dukuh Bulak Banteng with cover 100 household.


2018 ◽  
Vol 7 (4.20) ◽  
pp. 310
Author(s):  
Ali Hadi Ghawi

In this study, a sewage treatment plant was designed for the city of Al-Nasiriyah in Dhi Qar governorate in southern Iraq serving 316083 inhabitants. The resulting treated water is suitable for agricultural irrigation and can be discharged to the Euphrates River when needed by adding nitrogen and phosphorus removal units to the wastewater treatment plant. The obtained plant design has been verified and optimized by implementing the proposed plant layout in the GPS-X 5.0 modeling and simulation software (Hydromantis). Where the results of the design showed that the total phosphorus flow is higher than the desired limit of 2 mg / L, due to the excessive release during anaerobic digestion. Control of phosphorus concentration can be controlled by adding chemicals (iron or aluminum salts) in different parts of the wastewater treatment plant. In this case, two different control strategies can be implemented: adding aluminum doses in both water and sludge lines (at Chem1 and Chem2 points) or adding aluminum doses in the water line only (at point Chem2). The second strategy showed that it is the most efficient in controlling the concentration of phosphorus and nitrogen produced, which meets the limits of the Iraqi standard of water used in irrigation.  


2020 ◽  
Vol 15 (2) ◽  
pp. 142-151
Author(s):  
Peter Lukac ◽  
Lubos Jurik

Abstract:Phosphorus is a major substance that is needed especially for agricultural production or for the industry. At the same time it is an important component of wastewater. At present, the waste management priority is recycling and this requirement is also transferred to wastewater treatment plants. Substances in wastewater can be recovered and utilized. In Europe (in Germany and Austria already legally binding), access to phosphorus-containing sewage treatment is changing. This paper dealt with the issue of phosphorus on the sewage treatment plant in Nitra. There are several industrial areas in Nitra where record major producers in phosphorus production in sewage. The new wastewater treatment plant is built as a mechanicalbiological wastewater treatment plant with simultaneous nitrification and denitrification, sludge regeneration, an anaerobic zone for biological phosphorus removal at the beginning of the process and chemical phosphorus precipitation. The sludge management is anaerobic sludge stabilization with heating and mechanical dewatering of stabilized sludge and gas management. The aim of the work was to document the phosphorus balance in all parts of the wastewater treatment plant - from the inflow of raw water to the outflow of purified water and the production of excess sludge. Balancing quantities in the wastewater treatment plant treatment processes provide information where efficient phosphorus recovery could be possible. The mean daily value of P tot is approximately 122.3 kg/day of these two sources. The mean daily value of P tot is approximately 122.3 kg/day of these two sources. There are also two outflows - drainage of cleaned water to the recipient - the river Nitra - 9.9 kg Ptot/day and Ptot content in sewage sludge - about 120.3 kg Ptot/day - total 130.2 kg Ptot/day.


1998 ◽  
Vol 33 (2) ◽  
pp. 231-252 ◽  
Author(s):  
D.T. Bennie ◽  
C.A. Sullivan ◽  
H.-B. Lee ◽  
R.J. Maguire

Abstract Nonylphenol polyethoxylates and their refractory metabolites, including nonylphenol, are on the second Priority Substances List (PSL2) to determine if they are "toxic" as defined under the Canadian Environmental Protection Act. This study addresses the need for data on their occurrence in raw sewage, final effluents and sludge in Canada. Samples of raw sewage, final effluent and sludge were collected from 16 wastewater treatment plants across Canada in 1995 and 1996. These samples were analyzed for 4-nonylphenol (4-NP), nonylphenol ethoxylate (NP1EO), nonylphenol diethoxylate (NP2EO) and 4-4-tert-octylphenol (4-t-OP). Measurable quantities of these chemicals were found in almost all raw sewage and sludge samples. In the raw sewage, concentrations ranged from <0.005 to 21 μg/L for 4-t-OP, from 0.69 to 155 μg/L for 4-NP, from 2.9 to 43 μg/L for NP1EO and from 0.26 to 24 μg/L for NP2EO. Sludge concentrations (based on dry weight) ranged from <0.010 to 20 μg/g, from 8.4 to 850 μg/g, from 3.9 to 437 μg/g and from 1.5 to 297 μg/g for 4-t-OP, 4-NP, NP1EO and NP2EO, respectively. Of the final effluent samples, 60% contained detectable amounts of 4-t-OP and concentrations ranged from <0.005 to 0.37 μg/L. Almost all of the final effluent samples had detectable levels of 4-NP, NP1EO and NP2EO. The 4-NP concentrations varied from <0.020 to 13 μg/L, NP1EO was found in the range of 0.072 to 26 μg/L and NP2EO was found in the range of 0.099 to 21 μg/L.


2011 ◽  
Vol 11 (3) ◽  
pp. 97-103
Author(s):  
Jerzy Jańczak ◽  
Wojciech Maślanka ◽  
Kamil Nowiński

Causes of polytrophism of three lakes in the Wdzydze Landscape ParkIn the lakes Cheb and Słupino, located in the Wdzydze Landscape Park the quality of waters has been deteriorating in recent years. In the hydrologic year 2009 the quality of water was examined three times. Monthly measurements on the lake inflows and outflows were carried out 12 times to determine biogenic loads. In 2010 the supplementary measurements of biogenic loads were taken in the streams five times. According to Vollenweider's criterion, the loads of nitrogen and phosphorus compounds are too big, the heaviest to Lake Cheb. The discharge from the new sewage treatment plant is directed by the inflows into this lake. A similar situation takes place in the inflow to Lake Schodno. Paradoxically, in some catchments the construction of the sewage treatment plant may result in the deterioration of lake water quality.


2017 ◽  
Vol 35 (1) ◽  
pp. 141-148 ◽  
Author(s):  
Michał Marzec

AbstractThe reliability of removal of selected contaminants in three technological solutions of the household sewage treatment plants was analysed in this paper. The reliability of the sewage treatment plant with activated sludge, sprinkled biological deposit and hybrid reactor (activated sludge and immersed trickling filter) was analyzed. The analysis was performed using the Weibull method for basic indicators of impurities, BOD5, COD and total suspended solids. The technological reliability of the active sludge treatment plant was 70% for BOD5, 87% for COD and 66% for total suspended solids. In the sewage treatment plant with a biological deposit, the reliability values determined were: 30% (BOD5), 60% (COD) and 67% (total suspended solids). In a treatment plant with a hybrid reactor, 30% of the BOD5and COD limit values were exceeded, while 30% of the total suspended solids were exceeded. The reliability levels are significantly lower than the acceptable levels proposed in the literature, which means that the wastewater discharged from the analysed wastewater treatment plants often exceeds the limit values of indicators specified in currently valid in Poland Regulation of the Minister of Environment for object to 2000 population equivalent.


2019 ◽  
Vol 9 (1) ◽  
Author(s):  
Zarimah Mohd Hanafiah ◽  
Wan Hanna Melini Wan Mohtar ◽  
Hassimi Abu Hasan ◽  
Henriette Stokbro Jensen ◽  
Anita Klaus ◽  
...  

Abstract The fluctuation of domestic wastewater characteristic inhibits the current conventional microbial-based treatment. The bioremediation fungi has received attention and reported to be an effective alternative to treat industrial wastewater. Similar efficient performance is envisaged for domestic wastewater whereby assessed performance of fungi for varying carbon-to-nitrogen ratios in domestic wastewater is crucial. Thus, the performance of pre-grown wild-Serbian Ganoderma lucidum mycelial pellets (GLMPs) was evaluated on four different synthetic domestic wastewaters under different conditions of initial pH (pH 4, 5, and 7) and chemical oxygen demand (COD) to nitrogen (COD/N) ratio of 3.6:1, 7.1:1, 14.2:1, and 17.8:1 (C3.6N1, C7.1N1, C14.2N1, and C17.8N1). The COD/N ratios with a constant concentration of ammonia–nitrogen (NH3–N) were chosen on the basis of the urban domestic wastewater characteristics sampled at the inlet basin of a sewage treatment plant (STP). The parameters of pH, COD, and NH3–N were measured periodically during the experiment. The wild-Serbian GLMPs efficiently removed the pollutants from the synthetic sewage. The COD/N ratio of C17.8N1 wastewater had the best COD and NH3–N removal, as compared to the lower COD/N ratio, and the shortest treatment time was obtained in an acidic environment at pH 4. The highest percentage for COD and NH3–N removal achieved was 96.0% and 93.2%, respectively. The results proved that the mycelium of GLMP has high potential in treating domestic wastewater, particularly at high organic content as a naturally sustainable bioremediation system.


Sign in / Sign up

Export Citation Format

Share Document