scholarly journals The Impact of Carbon Dioxide Concentration on the Human Health - Case Study

2018 ◽  
Vol 8 (1) ◽  
pp. 61-66 ◽  
Author(s):  
P. Kapalo ◽  
F. Domniţa ◽  
C. Bacoţiu ◽  
Nadija Spodyniuk

Abstract From various other studies, it is known that the maximum carbon dioxide concentration in different countries is between 1,000 ppm up to 1,500 ppm. Therefore, the research is focused on indoor environment, namely the production of pollutants from the persons inside office rooms. The article presents the trend of the carbon dioxide concentration from the occupants inside an office. It is examined the carbon dioxide production separately for men and women, for persons of different mass and for persons of different ages. It is also analyzed the carbon dioxide production during a sedentary and physical activities. In parallel with the production of carbon dioxide is presented the monitoring of the human pulse and blood pressure. All these parameters are monitored together with relative humidity and indoor air temperature. The aims of this paper is to describe the partial results of human respiration impact on indoor air quality in closed spaces and to research the connection between carbon dioxide concentration and human health.

Buildings ◽  
2020 ◽  
Vol 10 (7) ◽  
pp. 124 ◽  
Author(s):  
Claire Tam ◽  
Yuqing Zhao ◽  
Zaiyi Liao ◽  
Lian Zhao

Indoor air quality and thermal conditions are important considerations when designing indoor spaces to ensure occupant health, satisfaction, and productivity. Carbon dioxide (CO2) concentration and indoor air temperature are two measurable parameters to assess air quality and thermal conditions within a space. Occupants are progressively affected by the indoor environment as the time spent indoors prolongs. Specifically, there is an interest in carrying out investigations on the indoor environment through surveying existing Heating, Ventilation, Air Conditioning (HVAC) system operations in classrooms. Indoor air temperature and CO2 concentration in multiple lecture halls in Toronto, Canada were monitored; observations consistently show high indoor air temperature (overheating) and high CO2 concentration. One classroom is chosen as a representative case study for this paper. The results verify a strong correlation between the number of occupants and the increase in air temperature and CO2 concentration. Building Energy Simulation (BES) is used to investigate the causes of discomfort in the classroom, and to identify methods for regulating the temperature and CO2 concentration. This paper proposes retro-commissioning strategies that could be implemented in institutional buildings; specifically, the increase of outdoor airflow rate and the addition of occupancy-based pre-active HVAC system control. The proposed retrofit cases reduce the measured overheating in the classrooms by 2-3 °C (indoor temperature should be below 23 °C) and maintain CO2 concentration under 900 ppm (the CO2 threshold is 1000 ppm), showing promising improvements to a classroom’s thermal condition and indoor air quality.


Author(s):  
Vesna Lovec ◽  
Miroslav Premrov ◽  
Vesna Žegarac Leskovar

The experimental monitoring of carbon dioxide concentration was carried out in kindergartens in Slovenia, together with indoor air temperature and relative humidity, before and during the COVID-19 pandemic. The aim of the research was to estimate the practical impact of the pandemic on indoor air quality and thermal comfort. The case study sample included buildings with different architectural typology, which are predominantly present in the building stock of Slovenia. The monitoring process lasted for 125 days before and during the COVID-19 pandemic. The results have shown a better indoor air quality in kindergartens during the pandemic, mostly due to ventilation protocols and almost imperceptibly changed indoor air temperature. The COVID-19 pandemic affected air quality in kindergarten classrooms in Slovenia by reducing the average carbon dioxide concentration when children were present in classrooms by 30%.


2018 ◽  
Vol 49 ◽  
pp. 00133 ◽  
Author(s):  
Monika Wysocka

The quality of indoor environment is an extremely important issue, because people spend large parts of the day inside buildings. The quality of the indoor environment is largely dependent on the quality of indoor air. The parameters of the air we breathe affect our health and comfort of room use. Currently, when energy efficiency is a priority, it is difficult to maintain comfort and conditions appropriate for human health. The artificial environment in a room and related inadequate air quality cause many diseases, such as asthma, lung diseases, cardiovascular diseases, as well as poor well-being and reduced productivity. The Disability Adjusted Life Years (DALY) indicator means “loss of life corrected by disability” and is widely used by the World Health Organization to measure a disease burden on the population and identify the causes of a disease. The aim of the article is to present the structure of the DALY indicator and its suitability to assess the impact of indoor air quality on human health. The most frequent diseases caused by low quality of internal air were analysed based on statistical data. In addition, the possibilities of ventilation solutions have been presented, leading to the improvement of air quality in indoor environment.


2016 ◽  
Vol 836 ◽  
pp. 121-126
Author(s):  
Pradip Aryal ◽  
Thananchai Leephakpreeda

This paper presents a CFD analysis on thermal comfort and indoor air quality affected by partitions in an air-conditioned building. CFD experiments are carried out to simulate variables of indoor air before/after installation or removal of partitions. Accordingly, the Predicted Mean Vote (PMV) is determined as an indicator of thermal comfort while the carbon dioxide concentration within an air-conditioned space is used for the assessment of indoor air quality. Some simulated results are validated by measurements with good agreement where a case study is conducted in an air-conditioned space of a library. With the proposed methodology, it can be recommended in a case study that the significant effects of partition on thermal comfort are observed where the area with neutral sensation and slightly-cool sensation reduces significantly. The occupants feel uncomfortably cold after installing partition. The carbon dioxide concentrations slightly increase in some areas but the average concentration remains acceptable according to ASHRAE standard. Without the reinforcement of the air-conditioning units, the installation of partition at the desired location is not encouraged regarding to occupant’s thermal comfort and indoor air quality.


2019 ◽  
Vol 7 ◽  
pp. 954-959 ◽  
Author(s):  
Detelin Ganchev Markov ◽  
Sergey Mijorski ◽  
Peter Stankov ◽  
Iskra Simova ◽  
Radositna A. Angelova ◽  
...  

: People are one of the sources for deterioration of the indoor air quality. They worsen indoor air quality by their presence (respiration, bio-effluents), activities and habits. Through respiration, people decrease the oxygen concentration in the air of the occupied space and increase carbon dioxide and water vapor concentration in the indoor air as well as its temperature. The goal of the AIRMEN project is to find out if the rate of consumption of oxygen and emission of carbon dioxide (and water vapor) by people depends on the indoor air temperature as well as carbon dioxide concentration in the inhaled air. In order to achieve this goal a small climate chamber must be designed and constructed which allows for controlling and measuring both inflow and exposure parameters as well as for measuring outflow parameters. The principal goal of this paper is to present some important details, obtained by CFD simulations, from the design process of the climate chamber which precondition the air distribution in the chamber and hence the exposure parameters.


Perfusion ◽  
2010 ◽  
Vol 25 (6) ◽  
pp. 399-408 ◽  
Author(s):  
Jiachen Yang ◽  
Bin Wang ◽  
Ran Xu ◽  
Lei Wang

This paper is a description of the designing of a new mainstream device to measure human respiration carbon dioxide concentration, based on non-dispersive infrared (NDIR) absorption technology. The device can be used to accurately monitor the cardiopulmonary status during anaesthesia and mechanical ventilation in real time. This new device can not only make up the error of real-time gas measurement of the side-stream device, but also make up the accuracy of the main-stream device. In the paper, four issues which can affect the measurement accuracy were considered: respiration gas flow, turbulence of the light source with all ranges of wavelength, temperature drift and signal noise. The experimental results showed that the device could produce a stable output signal and deviation of measurement accuracy could be achieved to within 4%.


2020 ◽  
Vol 10 (13) ◽  
pp. 4631
Author(s):  
Motokazu Moritani ◽  
Norifumi Watanabe ◽  
Kensuke Miyamoto ◽  
Kota Itoda ◽  
Junya Imani ◽  
...  

Recent indoor air quality studies show that even 1000 parts per million (ppm) concentration of Carbon Dioxide (CO2) has an adverse effect on human intellectual activities. Therefore, it is required to keep the CO 2 concentration below a certain value in a room. In this study, in order to analyze the diffusion tendency of carbon dioxide by breathing, we constructed a simultaneous multi-point sensing system equipped with a carbon dioxide concentration sensor to measure indoor environment. Furthermore, it was evaluated whether the prediction model can be effectively used by comparing the prediction value by the model and the actually measured value from the sensor. The experimental results showed that CO 2 by exhaled breathing diffuses evenly throughout the room regardless of the sensor’s relative positions to the human test subjects. The existing model is sufficiently accurate in a room which has above at least a 0.67 cycle/h ventilation cycle. However, there is a large gap between the measured and the model’s predicted values in a room with a low ventilation cycle, and that suggests a measurement with a sensor still is necessary to precisely monitor the indoor air quality.


Proceedings ◽  
2018 ◽  
Vol 2 (20) ◽  
pp. 1309 ◽  
Author(s):  
Antonio Rodero ◽  
Dorota Anna Krawczyk

Carbon dioxide concentration is an important parameter to know Indoor Air Quality of a building. One of the most important sources of CO2 in poor ventilated building is human activity. This work presents a method for experimental determination of human CO2 generation rate based on measuring of time evolution of indoor CO2 concentration. The method is applied to 5 rooms of an educational building from Bialystok (Poland). Similar carbon dioxide gains were obtained in all rooms, around 0.0046 L/s, which correspond to theoretical CO2 generation rates of a sedentary activity for persons, males and females, between 21–30 years old, characteristics of occupants of analyzed rooms.


Author(s):  
Tomoyasu Hirano ◽  
Tokuaki Shobayashi ◽  
Teiji Takei ◽  
Fumihiko Wakao

It is too early to provide a clear answer on the impact of exposure to the second-hand aerosol of heated tobacco products (HTPs) in the planning of policy for smoke-free indoors legislation. Here, we conducted a preliminary study to evaluate indoor air quality with the use of HTPs. We first measured the concentration of nicotine and particulate matter (PM2.5) in the air following 50 puffs in the use of HTPs or cigarettes in a small shower cubicle. We then measured these concentrations in comparison with the use equivalent of smoking 5.4 cigarettes per hour in a 25 m3 room, as a typical indoor environment test condition. In the shower cubicle test, nicotine concentrations in indoor air using three types of HTP, namely IQOS, glo, and ploomTECH, were 25.9–257 μg/m3. These values all exceed the upper bound of the range of tolerable concentration without health concerns, namely 3 µg/m3. In particular, the indoor PM2.5 concentration of about 300 to 500 μg/m3 using IQOS or glo in the shower cubicle is hazardous. In the 25 m3 room test, in contrast, nicotine concentrations in indoor air with the three types of HTP did not exceed 3 μg/m3. PM2.5 concentrations were below the standard value of 15 μg/m3 per year for IQOS and ploomTECH, but were slightly high for glo, with some measurements exceeding 100 μg/m3. These results do not negate the inclusion of HTPs within a regulatory framework for indoor tolerable use from exposure to HTP aerosol, unlike cigarette smoke.