Experimental/theoretical investigation of the sound field of an isolated propeller, including angle of incidence effects

Author(s):  
T. ZANDBERGEN ◽  
S. SARIN ◽  
R. DONNELLY
2020 ◽  
Vol 10 (1) ◽  
Author(s):  
Bhaskar Singh ◽  
Mohammed M. Shabat ◽  
Daniel M. Schaadt

Abstract Herein, we report a theoretical investigation of large photocurrent density enhancement in a GaAs absorber layer due to non-absorbing spherical dielectric (SiO2) nanoparticles-based antireflection coating. The nanoparticles are embedded in a dielectric matrix (SiN) which improves the antireflection property of SiN ($$\lambda /4$$ λ / 4 coating) and let to pass more photons into the GaAs layer. The improvement is noticed omnidirectional and the highest is more than 100% at 85° angle of incidence with the nanoparticles’ surface filling density of 70%. Sunrise to sunset calculation of normalized photocurrent density over the course of a year have also shown improvements in the nanoparticles’ case.


2005 ◽  
Vol 12 (4) ◽  
pp. 225-235 ◽  
Author(s):  
Jeremy W. Trevathan ◽  
John R. Pearse

Results are presented for the numerically predicted sound transmission loss of a finite panel excited by plane wave sources at various angles of incidence. It is shown that the limitation commonly imposed upon the integration of the ‘mass law’ is not arbitrary. Rather, it is the upper integration limit at which a function dependent on cos2 (the ‘mass law’), when integrated, becomes equal to a function dependent on cos (the method used in this study, the ISO 140 experimental method) which has been integrated from zero to 90 degrees. The current definition of sound transmission loss implicitly assumes that a plane wave sound source at normal incidence to the panel surface will produce the highest level of excitation in the panel, and as the angle of incidence is increased the panel will experience decreasing levels of excitation. However, it is shown here that the excitation experienced by a panel due to a plane wave source is almost independent of the angle of incidence.


Author(s):  
David C. Joy

Electron channeling patterns (ECP) were first found by Coates (1967) while observing a large bulk, single crystal of silicon in a scanning electron microscope. The geometric pattern visible was shown to be produced as a result of the changes in the angle of incidence, between the beam and the specimen surface normal, which occur when the sample is examined at low magnification (Booker, Shaw, Whelan and Hirsch 1967).A conventional electron diffraction pattern consists of an angularly resolved intensity distribution in space which may be directly viewed on a fluorescent screen or recorded on a photographic plate. An ECP, on the other hand, is produced as the result of changes in the signal collected by a suitable electron detector as the incidence angle is varied. If an integrating detector is used, or if the beam traverses the surface at a fixed angle, then no channeling contrast will be observed. The ECP is thus a time resolved electron diffraction effect. It can therefore be related to spatially resolved diffraction phenomena by an application of the concepts of reciprocity (Cowley 1969).


Author(s):  
David C. Joy

In a crystalline solid the regular arrangement of the lattice structure influences the interaction of the incident beam with the specimen, leading to changes in both the transmitted and backscattered signals when the angle of incidence of the beam to the specimen is changed. For the simplest case the electron flux inside the specimen can be visualized as the sum of two, standing wave distributions of electrons (Fig. 1). Bloch wave 1 is concentrated mainly between the atom rows and so only interacts weakly with them. It is therefore transmitted well and backscattered weakly. Bloch wave 2 is concentrated on the line of atom centers and is therefore transmitted poorly and backscattered strongly. The ratio of the excitation of wave 1 to wave 2 varies with the angle between the incident beam and the crystal structure.


Author(s):  
W. E. Lee ◽  
A. H. Heuer

IntroductionTraditional steatite ceramics, made by firing (vitrifying) hydrous magnesium silicate, have long been used as insulators for high frequency applications due to their excellent mechanical and electrical properties. Early x-ray and optical analysis of steatites showed that they were composed largely of protoenstatite (MgSiO3) in a glassy matrix. Recent studies of enstatite-containing glass ceramics have revived interest in the polymorphism of enstatite. Three polymorphs exist, two with orthorhombic and one with monoclinic symmetry (ortho, proto and clino enstatite, respectively). Steatite ceramics are of particular interest a they contain the normally unstable high-temperature polymorph, protoenstatite.Experimental3mm diameter discs cut from steatite rods (∼10” long and 0.5” dia.) were ground, polished, dimpled, and ion-thinned to electron transparency using 6KV Argon ions at a beam current of 1 x 10-3 A and a 12° angle of incidence. The discs were coated with carbon prior to TEM examination to minimize charging effects.


Author(s):  
W.S. Putnam ◽  
C. Viney

Many sheared liquid crystalline materials (fibers, films and moldings) exhibit a fine banded microstructure when observed in the polarized light microscope. In some cases, for example Kevlar® fiber, the periodicity is close to the resolution limit of even the highest numerical aperture objectives. The periodic microstructure reflects a non-uniform alignment of the constituent molecules, and consequently is an indication that the mechanical properties will be less than optimal. Thus it is necessary to obtain quality micrographs for characterization, which in turn requires that fine detail should contribute significantly to image formation.It is textbook knowledge that the resolution achievable with a given microscope objective (numerical aperture NA) and a given wavelength of light (λ) increases as the angle of incidence of light at the specimen surface is increased. Stated in terms of the Abbe resolution criterion, resolution improves from λ/NA to λ/2NA with increasing departure from normal incidence.


1973 ◽  
Vol 16 (2) ◽  
pp. 267-270 ◽  
Author(s):  
John H. Mills ◽  
Seija A. Talo ◽  
Gloria S. Gordon

Groups of monaural chinchillas trained in behavioral audiometry were exposed in a diffuse sound field to an octave-band noise centered at 4.0 k Hz. The growth of temporary threshold shift (TTS) at 5.7 k Hz from zero to an asymptote (TTS ∞ ) required about 24 hours, and the growth of TTS at 5.7 k Hz from an asymptote to a higher asymptote, about 12–24 hours. TTS ∞ can be described by the equation TTS ∞ = 1.6(SPL-A) where A = 47. These results are consistent with those previously reported in this journal by Carder and Miller and Mills and Talo. Whereas the decay of TTS ∞ to zero required about three days, the decay of TTS ∞ to a lower TTS ∞ required about three to seven days. The decay of TTS ∞ in noise, therefore, appears to require slightly more time than the decay of TTS ∞ in the quiet. However, for a given level of noise, the magnitude of TTS ∞ is the same regardless of whether the TTS asymptote is approached from zero, from a lower asymptote, or from a higher asymptote.


1968 ◽  
Vol 11 (1) ◽  
pp. 204-218 ◽  
Author(s):  
Elizabeth Dodds ◽  
Earl Harford

Persons with a high frequency hearing loss are difficult cases for whom to find suitable amplification. We have experienced some success with this problem in our Hearing Clinics using a specially designed earmold with a hearing aid. Thirty-five cases with high frequency hearing losses were selected from our clinical files for analysis of test results using standard, vented, and open earpieces. A statistical analysis of test results revealed that PB scores in sound field, using an average conversational intensity level (70 dB SPL), were enhanced when utilizing any one of the three earmolds. This result was due undoubtedly to increased sensitivity provided by the hearing aid. Only the open earmold used with a CROS hearing aid resulted in a significant improvement in discrimination when compared with the group’s unaided PB score under earphones or when comparing inter-earmold scores. These findings suggest that the inclusion of the open earmold with a CROS aid in the audiologist’s armamentarium should increase his flexibility in selecting hearing aids for persons with a high frequency hearing loss.