An Active Power Line Conditioner for Current Harmonic Elimination in Power Supply System of Phased Array Antennas

Author(s):  
Huang-Jen Chiu ◽  
Hsiu-Ming Huang ◽  
Li-Wei Lin ◽  
Shann-Chyi Mou ◽  
Pang-Jung Liu
2002 ◽  
Vol 17 (3) ◽  
pp. 405-412 ◽  
Author(s):  
N. Vazquez ◽  
C. Aguilar ◽  
J. Arau ◽  
R.O. Caceres ◽  
I. Barbi ◽  
...  

2020 ◽  
Vol 1 (1) ◽  
pp. 21-30
Author(s):  
Olena Levon ◽  
Igor Domnin

The expediency of using a power active filter in the mode of reactive power compensation of the supply network for the powerful sounding pulses shaper power supply system of the Institute of ionosphere NAS and MES of Ukraine is shown. An analysis of the literature has been carried out, which shows the effectiveness of solving the problem of reactive power compensation, filtering higher harmonics of the power supply network using active filtering of higher harmonics of current or voltage using an additional energy source to obtain a compensating signal in the form of current or voltage. The choice of the power circuit for constructing a power active filter has been made. A voltage inverter on IGBT transistors is used as a power active filter. The basic principles of operation of the power active filter control system are described, which are based on the p-q theory of power and provide for the calculation of instantaneous values ​​of the task currents for each phase of a three-phase power supply system. The work of the Matlab-model of the power supply system of the shaper is shown, the oscillograms of the main energy characteristics of the shaper are given. As a result of using a power active filter, the current of the supply network becomes close to sinusoidal, and the power factor tends to 1. A positive effect on the efficiency of the shaper when the power active filter is included in the supply network is noted, which is due to the efficiency of compensation of the reactive power consumed by the shaper from the supply network. The simulation results are presented, in particular, graphs of reactive power change at the point of connecting the power active filter to the supply network, at different levels of reactive power consumption by the shaper. The results obtained confirmed the possibility of using a power active filter in the mode of reactive power compensation of the supply network when solving the problems of improving the electromagnetic compatibility of powerful sounding pulses shapers with the supply network, reducing losses and increasing the reliability of the shapers. Keywords: active power filter, reactive power control, control systems


2014 ◽  
Vol 543-547 ◽  
pp. 693-696
Author(s):  
Hao Hua Li ◽  
You Hua Wang ◽  
Dun Yu Zhu

270V high voltage DC power supply system with grid of light weight, uninterrupted power supply and a two power density higher characteristic, in recent years become a hot research topic in domestic and international air supply system.[ To ensure the high voltage DC bus power quality, for the safe operation of the aircraft is very important. Single phase aeronautical static inverter as a typical aircraft power system load, the input current ripple of the serious pollution of the high voltage DC power supply. Therefore, the harmonic pollution problem of how to control the high voltage DC power supply system has been increasingly concerned aviation power researchers.


2014 ◽  
Vol 703 ◽  
pp. 290-293 ◽  
Author(s):  
Yan Qiong Song ◽  
Le Ming Xiao ◽  
Wei Qiang Ye

This paper introduced the development of marine on-shore power supply system in China and abroad, and described the different control strategy of shore power based on uninterruptable power on-shore connection, as well as instance of variable frequency power supply between the port and ship for controlling harmonicdistortion, based on the Matlab simulation software to establish the simulation model of active power filter system,so as to provide the guarantee for achieving reliable paralleling between shore power and marine electrical system with effective harmonic elimination.


2013 ◽  
Vol 805-806 ◽  
pp. 763-771
Author(s):  
Rui Li ◽  
Yi Ming Hou ◽  
Zhen Jiang ◽  
Hao Xu ◽  
Shi Hong Miao ◽  
...  

This paper introduces a novel comprehensive-sequence components based directional relay to improve the protection performance of the power supply system of important power consumers. Based on the analysis of the characteristic of the phase relationship between the positive-sequence voltage and current in the fault conditions, Active Power Factor is defined to track the loading conditions real-time in the power system. In the proposed technique, the sensitivity of this novel relay is self-compensative by the Comprehensive-sequence components Criteria. Actually, by means of the studies on the characteristic of this novel relay, the proposed technique can be self-adaptive to the loading conditions, suitable for any type of fault and hold their fault direction decision stably.


2021 ◽  
Vol 288 ◽  
pp. 01053
Author(s):  
Svetlana Molot ◽  
Vasilina Kovalenko ◽  
Elena Pylskaya ◽  
Ivan Artyukhov ◽  
Sergey Stepanov

A feature of modern power supply systems is the presence of a large number of electrical devises that consume non-sinusoidal current. The examples of the devices are frequency converters or rectifiers of large unit power. But substations for supplying a group of variable frequency drives affect negatively also. Since the equivalent circuit of the power includes line inductive and capacitive elements, under certain conditions, resonant can occur in the power supply system. The model for studying a power supply system with a powerful rectifier load has been developed in the MATLAB + Simulink environment. The equivalent power line circuit is adopted in the form of a certain number of series-connected sections. The number of sections was chosen from the condition of obtaining information about all harmonics, which the electric power quality standard prescribes to analyze. The simulation results show the number of the harmonic at which the resonance occurs depends on the length of the power line. It has been found that at resonance, the maximum current harmonic circulates through the source. And at the end of the line in this moment, the current harmonic has a minimum value, while the corresponding voltage harmonic rises sharply.


2015 ◽  
Vol 21 (2) ◽  
pp. 63-76 ◽  
Author(s):  
Nishad Mendis ◽  
Kashem Mohammad Muttaqi ◽  
Sarath Perera ◽  
Mohammad Nasir Uddin

2019 ◽  
Vol 2 (1) ◽  
pp. 8-16 ◽  
Author(s):  
P. A. Khlyupin ◽  
G. N. Ispulaeva

Introduction: The co-authors provide an overview of the main types of wind turbines and power generators installed into wind energy devices, as well as advanced technological solutions. The co-authors have identified the principal strengths and weaknesses of existing wind power generators, if applied as alternative energy sources. The co-authors have proven the need to develop an algorithm for the selection of a wind generator-based autonomous power supply system in the course of designing windmill farms in Russia. Methods: The co-authors have analyzed several types of wind turbines and power generators. Results and discussions: The algorithm for the selection of a wind generator-based autonomous power supply system is presented as a first approximation. Conclusion: The emerging algorithm enables designers to develop an effective wind generator-based autonomous power supply system.


Sign in / Sign up

Export Citation Format

Share Document