Lunar Surface Gas Turbine Power Systems With Fission Reactor Heat Sources

Author(s):  
Albert Juhasz ◽  
Jerzy Sawicki
1984 ◽  
Vol 106 (4) ◽  
pp. 737-742 ◽  
Author(s):  
A. I. Kalina

A new thermodynamic energy cycle has been developed using a multicomponent working agent. This cycle is designed to replace the currently used Rankine Cycle as a bottoming cycle for a combined-cycle energy system as well as for generating electricity using low-temperature heat sources. Several combined power systems based on this cycle have been designed and cost-estimated. The efficiency of this cycle is from 1.6 to 1.9 times higher than that of the Rankine Cycle system, at the same border conditions. The investment cost per unit of power output for this cycle is lower than that for the Rankine Cycle system in approximately direct proportion to the energy advantage. The application of this cycle as a bottoming cycle in combined-cycle systems involves the use of an energy system which utilizes heat from the exhaust of a gas turbine, resulting in an increase in overall efficiency of up to 20 percent above the efficiency of the combined systems using the Rankine bottoming cycle. As a result, a thermal efficiency in the range of 50–52 percent can be achieved using a conventional gas turbine. The project to build the first experimental installation is now in progress. This installation is to become operational at the end of 1984.


Author(s):  
John L. Mason ◽  
Anthony Pietsch ◽  
Theodore R. Wilson ◽  
Allen D. Harper

A novel closed-cycle gas turbine power system is now under development by the GWF Power Systems Company for cogeneration applications. Nominally the system produces 5 megawatts (MW) of electric power and 80,000 lb/hr (36,287 kg/hr) of 1000 psig (6895 kPa) steam. The heat source is an atmospheric fluidized bed combustor (AFBC) capable of using low-cost solid fuels while meeting applicable emission standards. A simple, low-pressure ratio, single spool, turbomachine is utilized. This paper describes the system and related performance, as well as the development and test efforts now being conducted. The initial commercial application of the system will be for Enhanced Oil Recovery (EOR) of the heavy crudes produced in California.


Author(s):  
C. F. McDonald

Because of intense development in the aircraft gas turbine field over the last 30 years, the fixed boundary recuperator has received much less development attention than the turbomachinery, and is still proving to be the nemesis of the small gas turbine design engineer. For operation on cheap fuel, such as natural gas, the simple cycle-engine is the obvious choice, but where more expensive liquid fuels are to be burned, the economics of gas turbine operation can be substantially improved by incorporating an efficient, reliable recuperator. For many industrial, vehicular, marine, and utility applications it can be shown that the gas turbine is a more attractive prime mover than either the diesel engine or steam turbine. For some military applications the fuel logistics situation shows the recuperative gas turbine to be the most effective power plant. For small nuclear Brayton cycle space power systems the recuperator is an essential component for high overall plant efficiency, and hence reduced thermal rejection to the environment. Data are presented to show that utilization of compact efficient heat transfer surfaces developed primarily for aerospace heat exchangers, can result in a substantial reduction in weight and volume, for industrial, vehicular, marine, and nuclear gas turbine recuperators. With the increase in overall efficiency of the recuperative cycle (depending on the level of thermal effectiveness, and the size and type of plant), the cost of the heat exchanger can often be paid for in fuel savings, after only a few hundred hours of operation. Heat exchanger surface geometries and fabrication techniques, together with specific recuperator sizes for different applications, are presented. Design, performance, structural, manufacturing, and economic aspects of compact heat exchanger technology, as applied to the gas turbine, are discussed in detail, together with projected future trends in this field.


Author(s):  
Robert F. Steele ◽  
Dale C. Paul ◽  
Torgeir Rui

Since the early 1990’s there have been significant changes in the gas turbine, and power generation market place. The ‘F-Class’ Gas Turbines, with higher firing temperatures, single crystal materials, increased compressor pressure ratios and low emission combustion systems that were introduced in the early 1990’s have gained significant field experience. Many of the issues experienced by these new product introductions have been addressed. The actual reliability growth and current performance of these advanced technology machines will be examined. Additionally, the operating profiles anticipated for many of the units installed during this period has been impacted by both changes in the anticipated demand and increases in fuel costs, especially the cost of natural gas. This paper will review how these changes have impacted the Reliability, Availability, and Maintainability performance of gas turbines. Data from the ORAP® System, maintained by Strategic Power Systems, Inc, will be utilized to examine the actual RAM performance over the past 10 to 15 years in relation to goals and expectations. Specifically, this paper will examine the reliability growth of the F-Class turbines since the 1990’s and examine the reliability impact of duty cycle on RAM performance.


Author(s):  
Eleni Agelidou ◽  
Martin Henke ◽  
Thomas Monz ◽  
Manfred Aigner

Residential buildings account for approximately one fifth of the total energy consumption and 12 % of the overall CO2 emissions in the OECD countries. Replacing conventional boilers by a co-generation of heat and power in decentralized plants on site promises a great benefit. Especially, micro gas turbine (MGT) based combined heat and power systems are particularly suitable due to their low pollutant emissions without exhaust gas treatment. Hence, the overall aim of this work is the development of a recuperated inverted MGT as heat and power supply for a single family house with 1 kWel. First, an inverted MGT on a Brayton cycle MGT was developed and experimentally characterized, in previous work by the authors. This approach allows exploiting the potential of using the same components for both cycles. As a next step, the applicability of the Brayton cycle components operated in inverted mode needs to be evaluated and the requirements for a component optimization need to be defined, both, by pursuing thermodynamic cycle simulations. This paper presents a parametrization and validation of in-house 1D steady state simulation tool for an inverted MGT, based on experimental data from the inverted Brayton cycle test rig. Moreover, a sensitivity analysis is conducted to estimate the influence of every major component on the overall system and to identify the necessary optimizations. Finally, the component requirements for an optimized inverted MGT with 1 kWel and 16 % of electrical efficiency are defined. This work demonstrates the high potential of an inverted MGT for a decentralized heat and power generation when optimizing the system components.


Author(s):  
I K Smith

The world market for systems for power recovery from low-grade heat sources is of the order of £1 billion per annum. Many of these sources are hot liquids or gases from which conventional power systems convert less than 2.5 per cent of the available heat into useful power when the fluid is initially at a temperature of 100° C rising to 8–9 per cent at an initial temperature of 200°C. Consideration of the maximum work recoverable from such single-phase heat sources leads to the concept of an ideal trilateral cycle as the optimum means of power recovery. The trilateral flash cycle (TFC) system is one means of approaching this ideal which involves liquid heating only and two-phase expansion of vapour. Previous work related to this is reviewed and details of analytical studies are given which compare such a system with various types of simple Rankine cycle. It is shown that provided two-phase expanders can be made to attain adiabatic efficiencies of more than 75 per cent, the TFC system can produce outputs of up to 80 per cent more than simple Rankine cycle systems in the recovery of power from hot liquid streams in the 100–200°C temperature range. The estimated cost per unit net output is approximately equal to that of Rankine cycle systems. The preferred working fluids for TFC power plants are light hydrocarbons.


Author(s):  
Alberto Vannoni ◽  
Andrea Giugno ◽  
Alessandro Sorce

Abstract Renewable energy penetration is growing, due to the target of greenhouse-gas-emission reduction, even though fossil fuel-based technologies are still necessary in the current energy market scenario to provide reliable back-up power to stabilize the grid. Nevertheless, currently, an investment in such a kind of power plant might not be profitable enough, since some energy policies have led to a general decrease of both the average price of electricity and its variability; moreover, in several countries negative prices are reached on some sunny or windy days. Within this context, Combined Heat and Power systems appear not just as a fuel-efficient way to fulfill local thermal demand, but also as a sustainable way to maintain installed capacity able to support electricity grid reliability. Innovative solutions to increase both the efficiency and flexibility of those power plants, as well as careful evaluations of the economic context, are essential to ensure the sustainability of the economic investment in a fast-paced changing energy field. This study aims to evaluate the economic viability and environmental impact of an integrated solution of a cogenerative combined cycle gas turbine power plant with a flue gas condensing heat pump. Considering capital expenditure, heat demand, electricity price and its fluctuations during the whole system life, the sustainability of the investment is evaluated taking into account the uncertainties of economic scenarios and benchmarked against the integration of a cogenerative combined cycle gas turbine power plant with a Heat-Only Boiler.


Sign in / Sign up

Export Citation Format

Share Document