scholarly journals Attaining a Beam-Like Behavior with FRP Strips and CAM Ribbons

2018 ◽  
Vol 2 (3) ◽  
pp. 7 ◽  
Author(s):  
Elena Ferretti

One of the major concerns in the seismic retrofitting of masonry walls is that of increasing the ultimate load for out-of-plane forces. In multi-story buildings, these forces may originate from the hammering actions of floors, when the earthquake direction is orthogonal to the wall. A possibility for counteracting the out-of-plane displacements is retaining the wall by building some buttresses, that is, some beams lean against the wall and disposed vertically. Another possibility is to make the buttress in the thickness of the wall. In this second case, we must cut the wall for its entire height, realize the buttress, and restore the masonry wall around it. In both cases, the interventions are highly invasive. The first intervention also leads to increments of mass that enhance the attraction of seismic forces. The aim of this paper is to find a less invasive and lighter alternative for realizing buttresses. We proposed to use FRP strips and steel ribbons in a combined fashion, so as to realize an ideal vertical I-beam embedded into the wall, without requiring to cut the masonry. We also provided some experimental results for verifying the effectiveness of the model.

2018 ◽  
Vol 2 (3) ◽  
pp. 6-16 ◽  
Author(s):  
Elena Ferretti

Abstract One of the major concerns in the seismic retrofitting of masonry walls is that of increasing the ultimate load for out-of-plane forces. In multi-story buildings, these forces may originate from the hammering actions of floors, when the earthquake direction is orthogonal to the wall. A possibility for counteracting the out-of-plane displacements is retaining the wall by building some buttresses, that is, some beams lean against the wall and disposed vertically. Another possibility is to make the buttress in the thickness of the wall. In this second case, we must cut the wall for its entire height, realize the buttress, and restore the masonry wall around it. In both cases, the interventions are highly invasive. The first intervention also leads to increments of mass that enhance the attraction of seismic forces. The aim of this paper is to find a less invasive and lighter alternative for realizing buttresses. We proposed to use FRP strips and steel ribbons in a combined fashion, so as to realize an ideal vertical I-beam embedded into the wall, without requiring to cut the masonry. We also provided some experimental results for verifying the effectiveness of the model.


Buildings ◽  
2020 ◽  
Vol 10 (4) ◽  
pp. 72
Author(s):  
Simona Coccia ◽  
Fabio Di Carlo ◽  
Stefania Imperatore

The out-of-plane behaviour of the walls as a consequence of an earthquake is the main vulnerability of existing masonry structures. In the case of rigid in compression not tensile resistant material, incremental dynamic analyses may be employed to evaluate the effective strength of a rocking element. When the seismic capacity of the wall is inadequate, retrofit interventions are required to assure an acceptable safety level. Conventional seismic retrofitting techniques on masonry walls influence the seismic performance of the element, which typically is modified in an out-of-plane bending behaviour. In this paper, analytical investigations are presented to investigate the possibility of a seismic retrofitting intervention able to increase the seismic strength of the wall without modifying its seismic behaviour. The analysed retrofitting technique consists in the application of composite vertical bars either in the middle section of the wall or at its external surfaces. The seismic behaviour of the retrofitted masonry wall is analytically evaluated by means of a parametric incremental dynamic analysis, carried out with an ad hoc in-house software. The effectiveness of the intervention is analysed in terms of level of seismic improvement, defined as the ratio between the seismic capacity of the reinforced and unreinforced walls.


2021 ◽  
Vol 881 ◽  
pp. 149-156
Author(s):  
Mochamad Teguh ◽  
Novi Rahmayanti ◽  
Zakki Rizal

Building material innovations in various interlocking concrete block masonry from local materials to withstand lateral earthquake forces is an exciting issue in masonry wall research. The block hook has an advantage in the interlocking system's invention to withstand loads in the in-plane and out-of-plane orientations commonly required by the masonry walls against earthquake forces. Reviews of the investigation of in-plane and out-of-plane masonry walls have rarely been found in previous studies. In this paper, the results of a series of experimental tests with different interlocking models in resisting the simultaneous in-plane shear and out-of-plane bending actions on concrete blocks are presented. This paper presents a research investigation of various interlocking concrete blocks' mechanical properties with different hook thicknesses. Discussion of the trends mentioned above and their implications towards interlocking concrete block mechanical properties is provided.


Materials ◽  
2019 ◽  
Vol 12 (17) ◽  
pp. 2712
Author(s):  
Elena Ferretti

The present paper deals with an improvement of the strengthening technique consisting in the combined use of straps—made of stainless steel ribbons—and CFRP (Carbon Fiber Reinforced Polymer) strips, to increase the out-of-plane ultimate load of masonry walls. The straps of both the previous and the new combined technique pass from one face to the opposite face of the masonry wall through some holes made along the thickness, giving rise to a three-dimensional net of loop-shaped straps, closed on themselves. The new technique replaces the stainless steel ribbons with steel wire ropes, which form closed loops around the masonry units and the CFRP strips as in the previous technique. A turnbuckle for each steel wire rope allows the closure of the loops and provides the desired pre-tension to the straps. The mechanical coupling—given by the frictional forces—between the straps and the CFRP strips on the two faces of the masonry wall gives rise to an I-beam behavior that forces the CFRP strips to resist the load as if they were the two flanges of the same I-beam. Even the previous combined technique exploits the ideal I-beam mechanism, but the greater stiffness of the steel wire ropes compared to the stiffness of the steel ribbons makes the constraint between the facing CFRP strips stiffer. This gives the reinforced structural element a greater stiffness and delamination load. In particular, the experimental results show that the maximum load achievable with the second combined technique is much greater than the maximum load provided by the CFRP strips. Even the ultimate displacement turns out to be increased, allowing us to state that the second combined technique improves both strength and ductility. Since the CFRP strips of the combined technique run along the vertical direction of the wall, the ideal I-beam mechanism is particularly useful to counteract the hammering action provided by the floors on the perimeter walls, during an earthquake. Lastly, when the building suffers heavy structural damage due to a strong earthquake, the box-type behavior offered by the three-dimensional net of straps prevents the building from collapsing, acting as a device for safeguarding life.


2017 ◽  
Vol 747 ◽  
pp. 119-127 ◽  
Author(s):  
Francesco Monni ◽  
Enrico Quagliarini ◽  
Stefano Lenci

This paper presents the results of an experimental campaign aimed at improving the innovative technique of continuos basalt fiber (BF) stitching in order to repair the masonry panels damaged by seismic events or to enhance the seismic behavior of unreinforced masonry walls. The masonry panels were tested under out-of-plane actions, one of the common way of failure for masonry walls during an earthquake. The most significant change introduced respect to the system already tested in previous studies, is the presence of pre-tensioned elements and mechanical anchorage of the BF ropes, always with the end of proposing a dry retrofitting system. The results indicate the effectiveness of this, increasing the performance of masonry wall specimens under out-of-plane actions respect to the damaged and unreinforced conditions. Besides, this technique potentially appears fully sustainable, because it is cheap, compatible, reversible, fire, and chemical resistant, it improves but not replaces original materials and, finally, it does not substantially use synthetic adhesives. All these reasons make this novel application of BF ropes fully sustainable and specialized to architectural heritage restoration.


2014 ◽  
Vol 624 ◽  
pp. 429-436 ◽  
Author(s):  
Matteo Bruggi ◽  
Gabriele Milani ◽  
Alberto Taliercio

The problem of finding the optimal layout of FRP strips to effectively retrofit masonry walls undergoing transverse loads is dealt with, taking the presence of permanent vertical loads into account. An innovative topology optimization approach is proposed to define the minimum amount of reinforcement that keeps the stress within a given strength domain throughout the wall. The macroscopic strength properties of masonry are defined by means of a simplified limit analysis approach based on homogenization theory. The capabilities of the proposed procedure are illustrated through applications on a windowed panel subjected to out-of-plane actions and vertical loads.


2016 ◽  
Vol 32 (4) ◽  
pp. 2317-2335 ◽  
Author(s):  
Dante Navarrete-Macias ◽  
Jorge Varela-Rivera ◽  
Luis Fernandez-Baqueiro

This paper presents the results of a study on the out-of-plane seismic behavior of confined masonry walls. Five confined walls were tested under reverse cyclic loads. The variables studied were the axial stress and the wall aspect ratio. Analytical out-of-plane strength of walls was calculated considering the strengths of the wall panel and the concrete confining elements. The former was determined using the unidirectional strut method and the latter using a plastic analysis. It was observed that for walls with the same aspect ratio, as the axial stress increases, the out-of-plane strength increases. For walls with the same axial stress, as the aspect ratio increases, the strength decreases. Based on comparisons between analytical and experimental results, it was concluded that the models developed in this work predict accurately the out-of-plane strength of the walls.


2017 ◽  
Vol 8 (1) ◽  
pp. 11
Author(s):  
Mosfeka Mahabuba Akter ◽  
Atique Shahariar ◽  
Md. Shafiqul Islam

Brick masonry walls consist of the main elements that responsible for the global stability of brick masonry buildings when subjected to lateral loads such as wind and seismic forces. These elements are subjected to gravity forces, bending moments and shear forces due to the horizontal loading. The application of reinforcement increases the deformation capacity, controls the crack opening and allows a better distribution of stresses. Longitudinal reinforcements increase the flexural strength, even if they seem not to influence the shear behavior. Effectiveness of reinforcement on the increase of the resistance of brick masonry wall is highly related to the failure mode of the element. This paper shows the flexural strength of reinforced perforated brick masonry wall and weight loss of reinforcements for corrosion after a certain period of time. Several reinforce bar arrangements into the perforated brick masonry walls show the variety of possible applications.


Author(s):  
Noriko Takiyama ◽  
Akari Yamaguchi ◽  
Kohei Hara ◽  
Verdejo Juan Ramon Jimenez

The October 2013 Earthquake hit the Bohol Island of the Philippines. Many traditional churches were damaged by the earthquake. In this study, material tests were conducted to assess the strength of the Philippines’ traditional masonry wall, which is composed of various materials. Additionally, out-of-plane flexural experiments were conducted to elucidate the mechanical characteristics of masonry walls found in traditional churches. The wall specimens used in this study were made of a variety of materials with different compositions. The major findings of this study are summarized as follows: (a) compressive tests and splitting tensile tests were conducted for various test samples having distinct compositions. For both tests, the strength of the cylinders without additional materials was greater than that with contamination, expect for those containing egg whites; (b) out-of-plane flexural experiments were conducted on four specimens to identify their structural characteristics.


2017 ◽  
Vol 747 ◽  
pp. 158-165 ◽  
Author(s):  
Alessandro Bellini ◽  
Andrea Incerti ◽  
Claudio Mazzotti

Structural strengthening by using composite materials proved to be one of the most suitable solutions for reinforcing masonry buildings. In this framework, the focus point of the presented experimental study is to evaluate the out-of-plane behaviour of masonry walls strengthened with Fiber Reinforced Cementitious Matrix (FRCM) composites when subjected to horizontal actions, by analyzing and discussing failure modes and their out-of-plane capacity. To this purpose, a new experimental set-up was developed, capable of applying an axial force and out-of-plane horizontal actions on full-scale masonry panels, placed in vertical position and subjected to a stress state similar to that present on a real masonry wall. Experimental results, obtained by using traditional and innovative techniques (such as Digital Image Correlation), will be compared with those coming from more conventional tensile and bond tests performed on FRCM coupons applied on masonry substrates, making use of simple theoretical models.


Sign in / Sign up

Export Citation Format

Share Document