scholarly journals Prototipe Pengaman Kebakaran Rumah Menggunakan Thermal Camera

eLEKTRIKA ◽  
2021 ◽  
Vol 13 (2) ◽  
pp. 53
Author(s):  
Filmada Ocky Saputra ◽  
Ardiawan Bagus Harisa ◽  
Zaenal Arifin

80% of cases of building or house fires in Indonesia are caused by electrical short circuits. Currently, there are only MCB and ELCB devices protecting for building electrical installations, but these devices cannot protect the conditions that cause fires. In a short circuit, there will be heating of the short cable or device. In this study, researchers used a thermal camera that can be placed on an electrical panel to be able monitor the temperature of electrical panel which includes cables, MCB, or can be placed on other devices. When the detected object temperature exceeds a predetermined limit, the device will provide a warning in the form of sound and text and can automatically cut off electricity in the building's electricity network. This research produces a prototype of a power grid safety device using a Raspberry Pi that can be applied to buildings and objects that have the potential to emit excess heat that can cause fires. Systems it will be able to monitor, provide warnings and can automatically cut off the electricity network when the temperature of the observed object exceeds the specified limit and has the potential to emit excess heat which can cause a fire.

Energies ◽  
2021 ◽  
Vol 14 (8) ◽  
pp. 2160
Author(s):  
Arthur K. Barnes ◽  
Jose E. Tabarez ◽  
Adam Mate ◽  
Russell W. Bent

Protecting inverter-interfaced microgrids is challenging as conventional time-overcurrent protection becomes unusable due to the lack of fault current. There is a great need for novel protective relaying methods that enable the application of protection coordination on microgrids, thereby allowing for microgrids with larger areas and numbers of loads while not compromising reliable power delivery. Tools for modeling and analyzing such microgrids under fault conditions are necessary in order to help design such protective relaying and operate microgrids in a configuration that can be protected, though there is currently a lack of tools applicable to inverter-interfaced microgrids. This paper introduces the concept of applying an optimization problem formulation to the topic of inverter-interfaced microgrid fault modeling, and discusses how it can be employed both for simulating short-circuits and as a set of constraints for optimal microgrid operation to ensure protective device coordination.


2014 ◽  
Vol 513-517 ◽  
pp. 281-285
Author(s):  
Cheng Sun ◽  
Min Ju Ding ◽  
Yong Feng Zhang ◽  
Xun Tan ◽  
Peng Wang ◽  
...  

A variety of electrical apparatus used in daily life can cause fires because of internal or external factors. During cause identification of an electrical fire, the first short circuit melted marks of copper wire have been considered highly important because they are direct proofs. Additionally, overloaded short circuit caused by the overload of current due to excessive electrical usage can give rise to an electrical fire. Despite extensive research on the first short circuit in fire scenes, the overloaded short circuit remains difficult to be distinguished because of the limitation of commonly used testing methods. Conventional metallographic method is intuitionistic and simple, but may not provide detailed data of crystals such as misorientation of grains. Here a new method (electron backscattered diffraction, EBSD) is applied for identification of the first and overloaded short-circuited melted marks of copper wires in electrical fire scenes. Results show obvious morphological distinctions in melted marks of copper wires between the first and overloaded short circuits. Qualitative and Quantitative differences obtained from the contrast of the above two short circuit situations may assist for cause identification of electrical fires in the future.


Author(s):  
Xin Shen ◽  
Hongchun Shu ◽  
Min Cao ◽  
Nan Pan ◽  
Junbin Qian

In distribution networks with distributed power supplies, distributed power supplies can also be used as backup power sources to support the grid. If a distribution network contains multiple distributed power sources, the distribution network becomes a complex power grid with multiple power supplies. When a short-circuit fault occurs at a certain point on the power distribution network, the size, direction and duration of the short-circuit current are no longer single due to the existence of distributed power, and will vary with the location and capacity of the distributed power supply system. The change, in turn, affects the current in the grid, resulting in the generation and propagation of additional current. This power grid of power electronics will cause problems such as excessive standard mis-operation, abnormal heating of the converter and component burnout, and communication system failure. It is of great and practical significance to study the influence of distributed power in distributed power distribution networks.


Energies ◽  
2021 ◽  
Vol 14 (20) ◽  
pp. 6834
Author(s):  
Ruizhu Wu ◽  
Simon Mendy ◽  
Nereus Agbo ◽  
Jose Ortiz Gonzalez ◽  
Saeed Jahdi ◽  
...  

This paper investigates the impact of parameter variation between parallel connected SiC MOSFETs on short circuit (SC) performance. SC tests are performed on parallel connected devices with different switching rates, junction temperatures and threshold voltages (VTH). The results show that VTH variation is the most critical factor affecting reduced robustness of parallel devices under SC. The SC current conducted per device is shown to increase under parallel connection compared to single device measurements. VTH shift from bias–temperature–instability (BTI) is known to occur in SiC MOSFETs, hence this paper combines BTI and SC tests. The results show that a positive VGS stress on the gate before the SC measurement reduces the peak SC current by a magnitude that is proportional to VGS stress time. Repeating the measurements at elevated temperatures reduces the time dependency of the VTH shift, thereby indicating thermal acceleration of negative charge trapping. VTH recovery is also observed using SC measurements. Similar measurements are performed on Si IGBTs with no observable impact of VGS stress on SC measurements. In conclusion, a test methodology for investigating the impact of BTI on SC characteristics is presented along with key results showing the electrothermal dynamics of parallel devices under SC conditions.


2019 ◽  
Vol 2019 (1) ◽  
pp. 209-217
Author(s):  
F Isakov

The article considers the results of the analysis of autotransformers operation mode monitoring. The time diagram of active load current and oil temperature of autotransformer TashTES AT-3 is established and during one year changes of these variables and basic parameters of autotransformer were observed. Technical faults of the power transformer and high power autotransformer are established and methods of their elimination are determined. Damage of transformers and autotransformers with voltage of 110-500 kV of about 30% of the total number of outages which were accompanied by internal short-circuits and two main causes of damage were determined. The main causes of technological failures, which were not accompanied by internal short-circuits, are as follows: 20% of failures in operation of the onload tap-changer, 16% of oil leaks from the bushings, 13% of oil leaks and lowering of oil from the transformer due to violation of welded joints and rubber seals, 4% of engine damage to oil pumps of the cooling system, 3% of pressure increase in high-voltage hermetic bushings, 2% of film protection shell damage. The main reasons of technological violations accompanied by internal short-circuit in the transformer are as follows: breakdown of internal insulation of highvoltage bushings, insufficient short-circuit resistance, wear and tear of winding insulation, breakdown of insulation.


2013 ◽  
Vol 860-863 ◽  
pp. 1857-1861
Author(s):  
Li Wen Wang ◽  
Bi Qiang Tang ◽  
Ling Ling Pan ◽  
Fei Shi ◽  
Jun Liu

Topology adjustment is a main measure to limit short circuit current, but changes of power grid structure might bring deep impact on power system operation. Measures to limit short circuit current are difficult to apply online due to unable to completely evaluate its safety and feasibility. This paper presents an on-line decision support indicator system, which applied to evaluate online short circuit current level of power grid. Based on practical power grid model and typical cross-section, short circuit current level under the current and future maintenance mode is analyzed, decision support to limit short circuit current is given, and the effectiveness and feasibility of limiting measures are evaluated. Analysis results show that the index system is reasonable.