Motion Estimation for Gray Level Videos Using Different Block Matching Algorithms

2021 ◽  
Vol 39 (1B) ◽  
pp. 53-66
Author(s):  
Tareq Z. Hammood ◽  
Matheel E. Abdulmunim

Motion Estimation (ME) is a very important operation in video coding. In order to reduce complexity of computations involved in ME and to increase quality of this process, many Block Matching Motion Estimation (BMME) Algorithms are proposed. The aim of this paper is to compare between these algorithms and find the best one. Seven BMME algorithms are used in this paper. The performance of each algorithm is evaluated for different types of motion to determine the best one of these algorithms. The evaluation is based on search points, and Peak Signal to Noise Ratio (PSNR). The simulation shows that Hexagonal Search is faster than all other Block Matching (BM) algorithms used in this paper regardless the type of video because it requires less number of search points to evaluate motion vectors for the video sequence. It requires 11.2424 average search point (SP) for small motions and 13.9708 for fast motions. It also gives a good quality that is close enough to the quality given by Full Search

2014 ◽  
Vol 2 (2) ◽  
pp. 47-58
Author(s):  
Ismail Sh. Baqer

A two Level Image Quality enhancement is proposed in this paper. In the first level, Dualistic Sub-Image Histogram Equalization DSIHE method decomposes the original image into two sub-images based on median of original images. The second level deals with spikes shaped noise that may appear in the image after processing. We presents three methods of image enhancement GHE, LHE and proposed DSIHE that improve the visual quality of images. A comparative calculations is being carried out on above mentioned techniques to examine objective and subjective image quality parameters e.g. Peak Signal-to-Noise Ratio PSNR values, entropy H and mean squared error MSE to measure the quality of gray scale enhanced images. For handling gray-level images, convenient Histogram Equalization methods e.g. GHE and LHE tend to change the mean brightness of an image to middle level of the gray-level range limiting their appropriateness for contrast enhancement in consumer electronics such as TV monitors. The DSIHE methods seem to overcome this disadvantage as they tend to preserve both, the brightness and contrast enhancement. Experimental results show that the proposed technique gives better results in terms of Discrete Entropy, Signal to Noise ratio and Mean Squared Error values than the Global and Local histogram-based equalization methods


2014 ◽  
Vol 610 ◽  
pp. 686-694
Author(s):  
Chang Jiang Liu ◽  
Chao Chen ◽  
A Fei Zhang ◽  
Xiao Lang Yan

The diamond search (DS) algorithm is one of the most efficient block matching motion estimation algorithms by far and has already been applied in MPEG2/4. Through our research, we found that there is still some redundancy in the algorithm. In this paper, an improved new difference based search (DBS) algorithm is proposed. Simulation results demonstrate that the new algorithm outperforms the well-known diamond search (DS) algorithm and four step-searches (4SS). It obtains almost the same Peak Signal to Noise Ratio (PSNR) while requires less computations than the DS algorithm and 4SS algorithm.


2012 ◽  
Vol 241-244 ◽  
pp. 3014-3019 ◽  
Author(s):  
Xiao Bing Zhang ◽  
Xin Liu ◽  
Bo Liu ◽  
Jiang Hong Han ◽  
Hua Xia Wu

A new algorithm is proposed to adjust backlight luminance for local dimming of liquid crystal display (LCD) devices. PSNR (the peak signal-to-noise ratio) =30 is acted as the lowest standard to guarantee the quality of image in the algorithm. Based on the formula of PSNR=30, the square error value of the image distortion is gained. Then, luminance of backlight is gained dynamically by that the maximum gray level minus 1 into the formula proposed in the paper and decreases by one after each trial if the image quality requirement is not satisfied. In order to simplify the calculation, three important gray level values are selected to meet the requirements. The results show that the algorithm can greatly reduce the power consumption with guaranteeing the image quality and furthermore save much time in calculation and be better applied in hardware.


Author(s):  
Mourad Talbi ◽  
Med Salim Bouhlel

Background: In this paper, we propose a secure image watermarking technique which is applied to grayscale and color images. It consists in applying the SVD (Singular Value Decomposition) in the Lifting Wavelet Transform domain for embedding a speech image (the watermark) into the host image. Methods: It also uses signature in the embedding and extraction steps. Its performance is justified by the computation of PSNR (Pick Signal to Noise Ratio), SSIM (Structural Similarity), SNR (Signal to Noise Ratio), SegSNR (Segmental SNR) and PESQ (Perceptual Evaluation Speech Quality). Results: The PSNR and SSIM are used for evaluating the perceptual quality of the watermarked image compared to the original image. The SNR, SegSNR and PESQ are used for evaluating the perceptual quality of the reconstructed or extracted speech signal compared to the original speech signal. Conclusion: The Results obtained from computation of PSNR, SSIM, SNR, SegSNR and PESQ show the performance of the proposed technique.


2012 ◽  
Vol 29 (6) ◽  
pp. 772-795 ◽  
Author(s):  
Lei Lei ◽  
Guifu Zhang ◽  
Richard J. Doviak ◽  
Robert Palmer ◽  
Boon Leng Cheong ◽  
...  

Abstract The quality of polarimetric radar data degrades as the signal-to-noise ratio (SNR) decreases. This substantially limits the usage of collected polarimetric radar data to high SNR regions. To improve data quality at low SNRs, multilag correlation estimators are introduced. The performance of the multilag estimators for spectral moments and polarimetric parameters is examined through a theoretical analysis and by the use of simulated data. The biases and standard deviations of the estimates are calculated and compared with those estimates obtained using the conventional method.


Sensors ◽  
2021 ◽  
Vol 21 (16) ◽  
pp. 5540
Author(s):  
Nayeem Hasan ◽  
Md Saiful Islam ◽  
Wenyu Chen ◽  
Muhammad Ashad Kabir ◽  
Saad Al-Ahmadi

This paper proposes an encryption-based image watermarking scheme using a combination of second-level discrete wavelet transform (2DWT) and discrete cosine transform (DCT) with an auto extraction feature. The 2DWT has been selected based on the analysis of the trade-off between imperceptibility of the watermark and embedding capacity at various levels of decomposition. DCT operation is applied to the selected area to gather the image coefficients into a single vector using a zig-zig operation. We have utilized the same random bit sequence as the watermark and seed for the embedding zone coefficient. The quality of the reconstructed image was measured according to bit correction rate, peak signal-to-noise ratio (PSNR), and similarity index. Experimental results demonstrated that the proposed scheme is highly robust under different types of image-processing attacks. Several image attacks, e.g., JPEG compression, filtering, noise addition, cropping, sharpening, and bit-plane removal, were examined on watermarked images, and the results of our proposed method outstripped existing methods, especially in terms of the bit correction ratio (100%), which is a measure of bit restoration. The results were also highly satisfactory in terms of the quality of the reconstructed image, which demonstrated high imperceptibility in terms of peak signal-to-noise ratio (PSNR ≥ 40 dB) and structural similarity (SSIM ≥ 0.9) under different image attacks.


2019 ◽  
Vol 829 ◽  
pp. 252-257
Author(s):  
Azhari ◽  
Yohanes Hutasoit ◽  
Freddy Haryanto

CBCT is a modernized technology in producing radiograph image on dentistry. The image quality excellence is very important for clinicians to interpret the image, so the result of diagnosis produced becoming more accurate, appropriate, thus minimizing the working time. This research was aimed to assess the image quality using the blank acrylic phantom polymethylmethacrylate (PMMA) (C­5H8O2)n in the density of 1.185 g/cm3 for evaluating the homogeneity and uniformity of the image produced. Acrylic phantom was supported with a tripod and laid down on the chin rest of the CBCT device, then the phantom was fixed, and the edge of the phantom was touched by the bite block. Furthermore, the exposure of the X-ray was executed toward the acrylic phantom with various kVp and mAs, from 80 until 90, with the range of 5 kV and the variation of mA was 3, 5, and 7 mA respectively. The time exposure was kept constant for 25 seconds. The samples were taken from CBCT acrylic images, then as much as 5 ROIs (Region of Interest) was chosen to be analyzed. The ROIs determination was analyzed by using the ImageJ® software for recognizing the influence of kVp and mAs towards the image uniformity, noise and SNR. The lowest kVp and mAs had the result of uniformity value, homogeneity and signal to noise ratio of 11.22; 40.35; and 5.96 respectively. Meanwhile, the highest kVp and mAs had uniformity value, homogeneity and signal to noise ratio of 16.96; 26.20; and 5.95 respectively. There were significant differences between the image uniformity and homogeneity on the lowest kVp and mAs compared to the highest kVp and mAs, as analyzed with the ANOVA statistics analysis continued with the t-student post-hoc test with α = 0.05. However, there was no significant difference in SNR as analyzed with the ANOVA statistic analysis. The usage of the higher kVp and mAs caused the improvement of the image homogeneity and uniformity compared to the lower kVp and mAs.


2015 ◽  
Vol 22 (2) ◽  
pp. 452-457 ◽  
Author(s):  
Yimeng Yang ◽  
Feifei Yang ◽  
Ferdinand F. Hingerl ◽  
Xianghui Xiao ◽  
Yijin Liu ◽  
...  

There is high demand for efficient, robust and automated routines for tomographic data reduction, particularly for synchrotron data. Registration of the rotation axis in data processing is a critical step affecting the quality of the reconstruction and is not easily implemented with automation. Existing methods for calculating the center of rotation have been reviewed and an improved algorithm to register the rotation axis in tomographic data is presented. The performance of the proposed method is evaluated using synchrotron-based microtomography data on geological samples with and without artificial reduction of the signal-to-noise ratio. The proposed method improves the reconstruction quality by correcting both the tilting error and the translational offset of the rotation axis. The limitation of this promising method is also discussed.


Sign in / Sign up

Export Citation Format

Share Document