scholarly journals Developing an individual profile of attentional control strategy

Author(s):  
Jessica Irons ◽  
Andrew B. Leber

What makes one person better at controlling attention than the next? Attempts to answer this question have largely focused on measuring individuals’ cognitive abilities. However, variation in attentional performance can also be due to differences in strategy. Here we describe research showing that individuals vary dramatically in how they choose to control attention, with many reliably choosing suboptimal strategies. Optimal strategy choice appears to be unrelated to attentional control ability, general cognitive ability, or even strategy choice on other attention tasks. It does, however, correlate with how effortful individuals find the optimal strategy, suggesting strategy choice may be driven by subjective, task-specific effort demands. These findings represent initial steps toward fully characterizing an individual profile of attentional control strategies.

2020 ◽  
Vol 29 (4) ◽  
pp. 364-371 ◽  
Author(s):  
Jessica L. Irons ◽  
Andrew B. Leber

What makes one person better at controlling attention than the next person? Attempts to answer this question have largely focused on measuring individuals’ cognitive abilities. However, variation in attentional performance can also be due to differences in strategy. Here, we describe research showing that individuals vary dramatically in how they choose to control attention, with many reliably choosing suboptimal strategies. Optimal strategy choice appears to be unrelated to attentional control ability, general cognitive ability, or even strategy choice on other attention tasks. It does, however, correlate with how effortful individuals find the optimal strategy, which suggests that strategy choice may be driven by subjective, task-specific effort demands. These findings represent initial steps toward fully characterizing an individual profile of attentional control strategies.


2011 ◽  
Vol 135-136 ◽  
pp. 261-267
Author(s):  
Hai Tao Min ◽  
Dong Jin Ye ◽  
Yuan Bin Yu

This paper introduced the structure of Extended-Range Electric Vehicles as well as its characteristics. Principle researches have been offered on the parameters matching of the power-train and main components. Operating modes and control strategies were discussed, especially the two control strategies of charge sustaining mode which is shown as load following strategy and engine optimal strategy, and the effects of both control strategies are simulated and analyzed. The results indicate that the load following strategy can obviously extend battery’s lifespan, but the engine optimal strategy can reduce fuel consumption and emission effectively.


2021 ◽  
Author(s):  
Walden Y. Li ◽  
Molly R McKinney ◽  
Jessica Irons ◽  
Andrew B. Leber

Does attentional control strategy generalize across different visual search tasks? Previous research has failed to observe significant correlations in strategy metrics between different visual search tasks (Clarke et al., 2020), suggesting that strategy is not unitary, or determined by a single trait variable. Here we question just how heterogeneous (non-unitary) strategies are, hypothesizing a similarity gradient account, which holds that strategy does generalize to some degree, specifically across tasks with similar attentional components. To test this account, we employed the Adaptive Choice Visual Search (ACVS; Irons & Leber, 2018a), a visual search paradigm designed to directly measure attentional control strategy. In two studies, we had participants complete the ACVS and a modified, but similar, task with one altered attentional component (specifically, the requirement to use feature-based attention and enumeration, respectively). We found positive correlations in strategy optimality between tasks that do vs. do not involve feature-based attention (r = .38, p = .0068) and across tasks that do vs. do not require enumeration (r = .33, p = .018). Thus, attentional control strategies did generalize across sufficiently similar tasks, although the strength of the correlations was weaker than the within-task test-retest reliability of strategy measure. These results support the similarity gradient account.


Author(s):  
Carla Benea ◽  
Laura Rendon ◽  
Jesse Papenburg ◽  
Charles Frenette ◽  
Ahmed Imacoudene ◽  
...  

Abstract Objective: Evidence-based infection control strategies are needed for healthcare workers (HCWs) following high-risk exposure to severe acute respiratory coronavirus virus 2 (SARS-CoV-2). In this study, we evaluated the negative predictive value (NPV) of a home-based 7-day infection control strategy. Methods: HCWs advised by their infection control or occupational health officer to self-isolate due to a high-risk SARS-CoV-2 exposure were enrolled between May and October 2020. The strategy consisted of symptom-triggered nasopharyngeal SARS-CoV-2 RNA testing from day 0 to day 7 after exposure and standardized home-based nasopharyngeal swab and saliva testing on day 7. The NPV of this strategy was calculated for (1) clinical coronavirus disease 2019 (COVID-19) diagnosis from day 8–14 after exposure, and for (2) asymptomatic SARS-CoV-2 detected by standardized nasopharyngeal swab and saliva specimens collected at days 9, 10, and 14 after exposure. Interim results are reported in the context of a second wave threatening this essential workforce. Results: Among 30 HCWs enrolled, the mean age was 31 years (SD, ±9), and 24 (80%) were female. Moreover, 3 were diagnosed with COVID-19 by day 14 after exposure (secondary attack rate, 10.0%), and all cases were detected using the 7-day infection control strategy: the NPV for subsequent clinical COVID-19 or asymptomatic SARS-CoV-2 detection by day 14 was 100.0% (95% CI, 93.1%–100.0%). Conclusions: Among HCWs with high-risk exposure to SARS-CoV-2, a home-based 7-day infection control strategy may have a high NPV for subsequent COVID-19 and asymptomatic SARS-CoV-2 detection. Ongoing data collection and data sharing are needed to improve the precision of the estimated NPV, and here we report interim results to inform infection control strategies in light of a second wave threatening this essential workforce.


Author(s):  
Young Joo Shin ◽  
Peter H. Meckl

Benchmark problems have been used to evaluate the performance of a variety of robust control design methodologies by many control engineers over the past 2 decades. A benchmark is a simple but meaningful problem to highlight the advantages and disadvantages of different control strategies. This paper verifies the performance of a new control strategy, which is called combined feedforward and feedback control with shaped input (CFFS), through a benchmark problem applied to a two-mass-spring system. CFFS, which consists of feedback and feedforward controllers and shaped input, can achieve high performance with a simple controller design. This control strategy has several unique characteristics. First, the shaped input is designed to extract energy from the flexible modes, which means that a simpler feedback control design based on a rigid-body model can be used. In addition, only a single frequency must be attenuated to reduce residual vibration of both masses. Second, only the dynamics between control force and the first mass need to be considered in designing both feedback and feedforward controllers. The proposed control strategy is applied to a benchmark problem and its performance is compared with that obtained using two alternative control strategies.


2014 ◽  
Vol 525 ◽  
pp. 646-652
Author(s):  
Min Bian ◽  
Qing Yun Guo

The robust H2/<em>H</em>∞ control strategy for a class of linear continuous-time uncertain systems with randomly jumping parameters is investigated. The transition of the jumping parameters is decided by a finite-state Markov process. The uncertainties are supposed to be norm-bounded. It is desired to design a linear state feedback control strategies such that the closed-loop system satisfies H performance and minimizes the H2 norm of the system. A sufficient condition is first established on the existence of the robust H2/<em>H</em>∞controller bases on the bounded real lemma. Then the corresponding state-feedback law is given in terms of a set of linear matrix inequalities (LMIs). It is showed that this condition is equivalent to the feasible solutions problem of LMI. Furthermore, the control strategy design problem is converted into a convex optimization problem subject to LMI constraints, which can be easily solved by standard numerical software.


2014 ◽  
Vol 909 ◽  
pp. 317-322
Author(s):  
Huan Pao Huang ◽  
Ji An Yu ◽  
Qian Su ◽  
Lei Wang

2 × 660MW ultra-supercritical units of O'Brien Power Plant are single configuration of auxiliary pilot project, due to the higher its parameters and performance requirements, it need better control strategies to ensure safe and economical operation. Against traditional cascade PID main steam’s temperature control system delaying large, this article proposed control strategy based on Smith estimated. Main steam’s temperature controlled object inert zone mathematical model can be showed by multi-volume model, and use the improved system for large inertia Smith Predictor to make dynamic parameter control systems improvements. Simulation results of the simulation machine show that: Optimization emperor steam temperature control is in an adjustable range and the policy in separate auxiliary units is feasible.


2012 ◽  
Vol 512-515 ◽  
pp. 788-793
Author(s):  
Xiao Hua Zhou ◽  
Ming Qiang Wang ◽  
Wei Wei Zou

Traditional decoupling control strategy of doubly-fed induction generator (DFIG) wind turbine makes little contribution to system inertia and do not participate in the system frequency control, the synchronization of large-scale wind power requires wind turbine have the ability to participate in the regulation of power system frequency. This paper adds a frequency control segment to traditional DFIG wind turbine and considers the doubly-fed wind turbine operating on the state of the super-synchronous speed, by analysis the effect of inertia and proportional control strategies, a fuzzy control strategy which combines the advantages of the former two control strategies is proposed, simulation results show that this control strategy can more effectively improve the system frequency response.


2021 ◽  
Vol 25 (5) ◽  
Author(s):  
Jeanne Moldenhauer

Warning letters and regulatory inspection observation reports (e.g., FDA 483) often provide useful information for assessing risks in your facility and preparing for upcoming inspections. Starting with the updates to the European Union’s Annex 1 for the Manufacture of Sterile Drugs there has been an increased focus on contamination control strategies in facilities. A contamination control strategy is an integral part of pharmaceutical manufacturing, whether sterile or non-sterile. For this article we are going to look at a series of observations for a vaccine production facility and how we might learn from these observations. Highlighted are some of the contamination control issues. The FDA 483 Report was published in redacted form.


2021 ◽  
Vol ahead-of-print (ahead-of-print) ◽  
Author(s):  
Vikash Gurugubelli ◽  
Arnab Ghosh

Purpose The share of renewable energy sources (RESs) in the power system is increasing day by day. The RESs are intermittent, therefore maintaining the grid stability and power balance is very difficult. The purpose of this paper is to control the inverters in microgrid using different control strategies to maintain the system stability and power balance. Design/methodology/approach In this paper, different control strategies are implemented to the voltage source converter (VSC) to get the desired performance. The DQ control is a basic control strategy that is inherently present in the droop and virtual synchronous machine (VSM) control strategies. The droop and VSM control strategies are inspired by the conventional synchronous machine (SM). The main objective of this work is to design and implement the three aforementioned control strategies in microgrid. Findings The significant contributions of this work are: the detailed implementation of DQ control, droop control and VSM control strategies for VSC in both grid-connected mode and standalone mode is presented; the MATLAB/Simulink simulation results and comparative studies of the three aforementioned controllers are introduced first time in the proposed work; and the opal-RT digital real-time simulation results of the proposed VSM control show the superiority in transient response compared to the droop control strategy. Research limitations/implications In the power system, the power electronic-based power allowed by VSM is dominated by the conventional power which is generated from the traditional SM, and then the issues related to stability still need advance study. There are some differences between the SM and VSM characteristics, so the integration of VSM with the existing system still needs further study. Economical operation of VSM with hybrid storage is also one of the future scopes of this work. Originality/value The significant contributions of this work are: the detailed implementation of DQ control, droop control and VSM control strategies for VSC in both grid-connected mode and standalone mode is presented; the MATLAB/Simulink simulation results and comparative studies of the three aforementioned controllers are introduced first time in the proposed work; and the opal-RT digital real-time simulation results of the proposed VSM control show the superiority in transient response compared to the droop control strategy.


Sign in / Sign up

Export Citation Format

Share Document