Evaluation of Infrared Ignition Furnace for Determination of Asphalt Content

Author(s):  
Graham C. Hurley ◽  
Brian D. Prowell

The Troxler Model 4730 infrared ignition furnace was compared with a standard Thermolyne ignition furnace. Comparisons conducted with a single unit of each furnace type were based on the correction factor for aggregate loss during ignition, accuracy, and the variability of the measured asphalt content and aggregate degradation during ignition. Forty-eight samples representing two nominal maximum aggregate sizes (9.5 and 19.0 mm), four aggregate types (granite, crushed gravel, limestone, and dolomite), and two asphalt contents (optimum and optimum plus 0.5% asphalt content) were tested in each furnace. The results indicated that the correction factors for aggregate loss during ignition were significantly different for each type of furnace, thus requiring a separate calibration for each type of furnace. In practical terms, the differences for all but the 9.5-mm nominal maximum aggregate size (NMAS) limestone and both dolomite mixtures were less than 0.1%. The samples with the optimum plus 0.5% asphalt content were tested by using the calibration factors developed for a particular mix–furnace combination. The results were analyzed in terms of accuracy (bias) and variability (standard deviation). Neither the measured biases nor the standard deviations for the two types of furnaces were significantly different. The results obtained with four sieve sizes (NMAS and 4.75, 2.36, and 0.075 mm) were evaluated for aggregate breakdown. A comparison of the aggregate gradations recovered from both furnaces indicated no significant difference in the degree of aggregate degradation. A round-robin investigation should be conducted to confirm that the precision of the infrared furnace is similar to the precision of the standard furnace.

Author(s):  
Graham C. Hurley ◽  
Brian D. Prowell

Four methodologies for determining the asphalt content of mixtures containing high-loss aggregates in the ignition furnace were evaluated: the standard method using the Thermolyne furnace (control), the Troxler NTO infrared furnace, the Ontario method, and a Tempyrox glass-cleaning oven. Six aggregate sources with high ignition furnace aggregate corrections were obtained from around the country: four dolomites, a basalt, and a serpentine/chlorite. Calibration factors were determined for each method at optimum asphalt content. Additional samples were then tested at optimum plus 0.5% asphalt content, and the measured asphalt content was calculated by using the correction factor determined for that method and aggregate source. The Tempyrox Pyro-Clean furnace, commonly used for cleaning laboratory glassware, produced the lowest aggregate correction factors. The standard method and the Ontario method, both using the Thermolyne ignition furnace, produced the smallest bias or error in measured asphalt content. The standard deviation of the corrected asphalt contents for these high-loss sources was higher than the within-laboratory standard deviation reported for AASHTO T308. The only exception was the Alabama source using the standard method. The Ontario method and Tempyrox oven generally reduced the variability of asphalt content measurements for high-loss aggregates. None of the methods evaluated statistically reduced aggregate breakdown on the nominal maximum aggregate size and 4.75-mm sieves. The Ontario method significantly reduced, but did not eliminate, aggregate breakdown on the 0.075-mm sieve. The Ontario method is the best method for immediate implementation for determining the asphalt content by the ignition method for high-loss aggregates.


2019 ◽  
Vol 27 (1) ◽  
pp. 382-395
Author(s):  
Mousa Zeki ◽  
Shakir Al-Busaltan

Statistical modeling is utilized effectively to development relation/s between the dependent variables and independent variables. In other words, it describes how one or more random variables are related to one more other variables. Building verified models can help in predicting performance characteristics, and saving time and money. This study aims to present a statistical models which help to understand the significance of the different parameters in characterizing the performance of the Thin Asphalt Overlay (TAO). The experimental program included: design the thin asphalt overlay mixtures using one gradation type (9.5 Nominal Maximum Aggregate Size NMAS), three filler types (conventional mineral filler, Ordinary Portland Cement, and Quick lime), and five percentages of asphalt content to identify the optimum asphalt content. Then, Styrene Butadiene Styrene (SBS) modified polymer binder was introduced for performance enhancement. Performance tests were used to evaluate TAO mixture in term of some main namely, volumetric, mechanical, and durability properties are (bulk density, indirect tensile strength and tensile strength ratio). Statistical Product and Service Solutions (SPSS) software (Version 24) was used as a tool for models building. To find the most accurate statistical models, linear and nonlinear regression was achieved. This study demonstrates that the using statistical modeling is achievable and offer a vital tool to describe the characteristics and performance of the TAO mixture in term volumetric, mechanical and durability properties.


Author(s):  
Frazier Parker ◽  
M. Shabbir Hossain ◽  
Jiansheng Song

Asphalt content, voids, and mat density quality control–quality assurance data were collected for selected Marshall and Superpave mixes during 1997 and for selected Superpave mixes during 1998 and 1999. Analyses indicate that the accuracies and variabilities of asphalt content measurements for Marshall and Superpave mixes are comparable. However, analyses also indicate that the accuracies and variabilities of voids and mat density measurements are not comparable. Moreover, variabilities for Superpave mixes are much higher, and measurements for Superpave mixes are more off target than those for Marshall mixes. The effects of gyratory compactor use, mix design range for an equivalent single-axle load, and maximum aggregate size were investigated to explain the observed differences. Although few consistent trends were observed, all these factors seem to affect the variabilities and accuracies of air voids and mat densities of Superpave mixes.


2013 ◽  
Vol 723 ◽  
pp. 291-297 ◽  
Author(s):  
Mohd Khairul Idham ◽  
Hainin Mohd Rosli ◽  
Haryati Yaacob ◽  
M. Naqiuddin M. Warid ◽  
Mohd Ezree Abdullah

Asphalt hardens as a result of an aging process. This study was undertaken to determine the effect of field aging simulated by laboratory aging method of different hot mix asphalt (HMA) mixture. Three types HMA mixtures were used for this study namely Asphaltic Concrete with 10 mm nominal maximum aggregate size (AC 10), Aspaltic Concrete 28 mm (AC 28) and Porous Asphalt 10 mm (PA 10). The resilient modulus test was carried out as an indicator of the performance at a 25 °C and 40 °C. Generally, all samples show similar trend which aged mixture produced slightly higher resilient modulus compared to unaged mixture while an increase in temperature from 25 °C to 40 °C might reduced the resilient modulus up to 88%. This study also found that the difference increment of resilient modulus after the aging process attributed by asphalt content, air void and gradation of respective mixtures.


1996 ◽  
Vol 75 (05) ◽  
pp. 772-777 ◽  
Author(s):  
Sybille Albrecht ◽  
Matthias Kotzsch ◽  
Gabriele Siegert ◽  
Thomas Luther ◽  
Heinz Großmann ◽  
...  

SummaryThe plasma tissue factor (TF) concentration was correlated to factor VII concentration (FVIIag) and factor VII activity (FVIIc) in 498 healthy volunteers ranging in age from 17 to 64 years. Immunoassays using monoclonal antibodies (mAbs) were developed for the determination of TF and FVIIag in plasma. The mAbs and the test systems were characterized. The mean value of the TF concentration was 172 ± 135 pg/ml. TF showed no age- and gender-related differences. For the total population, FVIIc, determined by a clotting test, was 110 ± 15% and the factor VIlag was 0.77 ± 0.19 μg/ml. FVII activity was significantly increased with age, whereas the concentration demonstrated no correlation to age in this population. FVII concentration is highly correlated with the activity as measured by clotting assay using rabbit thromboplastin. The ratio between FVIIc and FVIIag was not age-dependent, but demonstrated a significant difference between men and women. Between TF and FVII we could not detect a correlation.


Problems when calculating reinforced concrete structures based on the concrete deformation under compression diagram, which is presented both in Russian and foreign regulatory documents on the design of concrete and reinforced concrete structures are considered. The correctness of their compliance for all classes of concrete remains very approximate, especially a significant difference occurs when using Euronorm due to the different shape and sizes of the samples. At present, there are no methodical recommendations for determining the ultimate relative deformations of concrete under axial compression and the construction of curvilinear deformation diagrams, which leads to limited experimental data and, as a result, does not make it possible to enter more detailed ultimate strain values into domestic standards. The results of experimental studies to determine the ultimate relative deformations of concrete under compression for different classes of concrete, which allowed to make analytical dependences for the evaluation of the ultimate relative deformations and description of curvilinear deformation diagrams, are presented. The article discusses various options for using the deformation model to assess the stress-strain state of the structure, it is concluded that it is necessary to use not only the finite values of the ultimate deformations, but also their intermediate values. This requires reliable diagrams "s–e” for all classes of concrete. The difficulties of measuring deformations in concrete subjected to peak load, corresponding to the prismatic strength, as well as main cracks that appeared under conditions of long-term step loading are highlighted. Variants of more accurate measurements are proposed. Development and implementation of the new standard GOST "Concretes. Methods for determination of complete diagrams" on the basis of the developed method for obtaining complete diagrams of concrete deformation under compression for the evaluation of ultimate deformability of concrete under compression are necessary.


2015 ◽  
Vol 72 (2) ◽  
pp. 123-131 ◽  
Author(s):  
Marko Igic ◽  
Nebojsa Krunic ◽  
Ljiljana Aleksov ◽  
Milena Kostic ◽  
Aleksandra Igic ◽  
...  

Background/Aim. The vertical dimension of occlusion is a very important parameter for proper reconstruction of the relationship between the jaws. The literature describes many methods for its finding, from the simple, easily applicable clinically, to quite complicated, with the use of one or more devices for determination. The aim of this study was to examine the possibility of determining the vertical dimension of occlusion using the vocals ?O? and ?E? with the control of values o btained by applying cognitive functions. Methods. This investigation was performed with the two groups of patients. The first group consisted of 50 females and 50 males, aged 18 to 30 years. In this group the distance between the reference points (on top of the nose and chin) was measured in the position of the mandible in the vertical dimension of occlusion, the vertical dimension at rest and the pronunciation of the words ?OLO? and ?ELE?. Checking the correctness of the particular value for the word ?OLO? was also performed by the phonetic method with the application of cognitive exercises when the patients counted from 89 to 80. The obtained difference in the average values i n determining the vertical dimension of occlusion and the ?OLO? and ?ELE? in the first group was used as the reference for determining the vertical dimension of occlusion in the second group of patients. The second group comprised of 31 edentulous persons (14 females and 17 males), aged from 54 to 85 years who had been made a complete denture. Results. The average value obtained for the vertical dimension of rest for the entire sample was 2.16 mm, for the word ?OLO? for the entire sample was 5.51 mm and for the word ?ELE? for the entire sample was 7.47 mm. There was no statistically significant difference between the genders for the value of the vertical dimension at rest, ?ELE? and ?OLO?. There was a statistically significant difference between the values f or the vertical dimension at rest, ?OLO? and ?ELE? for both genders. There was a statistically significant correlation between the value for the vertical dimension at rest, ?OLO? and ?ELE?, for both groups of subjects. Conclusion. Determining the vertical dimension of occlusion requires 5.5 mm subtraction from the position of the mandible in pronunciation of the word ?OLO? or 7.5 mm in pronunciation of the word ?ELE?.


Author(s):  
Nesma M Fahmy ◽  
Adel M Michael

Abstract Background Modern built-in spectrophotometer software supporting mathematical processes provided a solution for increasing selectivity for multicomponent mixtures. Objective Simultaneous spectrophotometric determination of the three naturally occurring antioxidants—rutin(RUT), hesperidin(HES), and ascorbic acid(ASC)—in bulk forms and combined pharmaceutical formulation. Method This was achieved by factorized zero order method (FZM), factorized derivative method (FD1M), and factorized derivative ratio method (FDRM), coupled with spectrum subtraction(SS). Results Mathematical filtration techniques allowed each component to be obtained separately in either its zero, first, or derivative ratio form, allowing the resolution of spectra typical to the pure components present in Vitamin C Forte® tablets. The proposed methods were applied over a concentration range of 2–50, 2–30, and 10–100 µg/mL for RUT, HES, and ASC, respectively. Conclusions Recent methods for the analysis of binary mixtures, FZM and FD1M, were successfully applied for the analysis of ternary mixtures and compared to the novel FDRM. All were revealed to be specific and sensitive with successful application on pharmaceutical formulations. Validation parameters were evaluated in accordance with the International Conference on Harmonization guidelines. Statistical results were satisfactory, revealing no significant difference regarding accuracy and precision. Highlights Factorized methods enabled the resolution of spectra identical to those of pure drugs present in mixtures. Overlapped spectra of ternary mixtures could be resolved by spectrum subtraction coupled FDRM (SS-FDRM) or by successive application of FZM and FD1M.


Author(s):  
Heba M El-Sayed ◽  
Laila E Abdel Fattah ◽  
Hisham E Abdellatef ◽  
Maha A Hegazy ◽  
Mai M Abd El-Aziz

Abstract Background Entecavir (ENT) is an antiretroviral agent prescribed for treatment of HBV and HIV. Objective Development and validation of three simple, sensitive, selective, and precise methods for determination of ENT in presence of its oxidative degradation product (ENT deg.). Methods The first method was based on second derivative (D2) spectrophotometry through measuring the peak amplitude of D2 spectra at 293.6 nm. The second one is mean centering of the ratio spectra (MCR), which allowed measuring the peak amplitude at 280.0 nm. While the third method was HPLC; where ENT was separated from ENT deg. using Zobrax C18column and methanol: water (30:70, v/v), pH 3 as a mobile phase. The three developed methods were validated according to ICH guidelines. Results Linearity range of ENT was 5.00–50.00 μg/mL for both D2and MCR. However, higher sensitivity was achieved using HPLC (1.00–50.00 μg/mL). Accuracy of ENT were 100.60%±0.547, 101.55%±1.2071 and 100.61%±1.207 for D2, MCR and HPLC methods, respectively, and precision was within 1.280. Conclusions The developed methods were successfully applied for the determination of ENT in Tecavir® tablets without interference from ENT deg. They showed no significant difference compared with the official method as well as they could be applied in the quality analysis of ENT with high selectivity, accuracy, and precision. Highlights ENT was quantified using two spectrophotometric (D2 and MCR) methods and an HPLC method in presence of ENT deg. The proposed methods were applied to analysis of ENT tablets with high selectivity, sensitivity, and accuracy.


Sign in / Sign up

Export Citation Format

Share Document