scholarly journals An experimental investigation on the coefficient of performance of the small hot water heat pump using refrigeration R410A and R32

Author(s):  
Le Minh Nhut ◽  
Tran Quang Danh

Hot water is an important factor in domestic life and industrial development. Today, the heat pump is used to produce hot water more and more popular because it has many advantages of saving energy compared to the method of producing hot water by the hot water electric heater. The main aim of this study is to evaluate of the coefficient of performance (COP) of the small hot water heat pump using refrigeration R410A and R32. The capacity of both hot water heat pump is similar, one using new refrigerant R32 and other using refrigerant R410A. These heat pumps were designed and installed at the Ho Chi Minh City University of Technology and Education to evaluate the COP for the purpose of application the new refrigerant R32 for hot water heat pump. The compressor capacity is 1 Hp, the volume of hot water storage tank is of 100 liters and is insulated with thickness of 30 mm to reduce the heat loss to invironment, the required hot water temperature at the outlet of condenser is 50 oC, and the amount of required hot water is 75 liters per batch and is controlled by float valve. The experimental results indicate that the COP of the heat pump using the new refrigerant R32 is higher than heat pump using refrigerant R410A from 9% to 15% when the experimental conditions such as ambient temperature, initial water flow rate through the condenser and the required temperature of hot water were the same. In addition, the effect of the ambient temperature, initial water temperature and water flow rate were also evaluated.

2018 ◽  
Vol 8 (10) ◽  
pp. 1973 ◽  
Author(s):  
Adnan Ploskić ◽  
Qian Wang ◽  
Sasan Sadrizadeh

The aim of this study was to map the parameters that have the greatest impact on the environmental impact of heating systems usually used in Nordic single-family dwellings. The study focused on mapping the technical requirements for efficient operation of heating systems in a broader context. The results suggest that the ability of a heating system to be operated with a low-temperature water supply depends to a large extent on the heating demand of a building. It was shown that an increase in the water flow rate in hydronic circuits would significantly increase the thermal efficiency from analyzed heating systems. This increase would not increase the pumping power need, nor would it create noise problems in distribution network if the distribution pipes and thermostatic valves were properly selected. However, this increase in water flow rate improved the efficiency of considered closed-loop heat pump. It was further shown that the efficiency of the heat pump could be additionally improved by halving the energy needs for the domestic hot-water and circulators. The main conclusion from this study is that exergy usage, CO2 emission and thereby environmental impact are significantly lower for heating systems that are operated with small temperature drops.


2015 ◽  
Vol 2015 ◽  
pp. 1-10 ◽  
Author(s):  
Wei Zhang ◽  
Tao Wang ◽  
Sulu Zheng ◽  
Xueyuan Peng ◽  
Xiaolin Wang

Gas engine driven heat pumps (GEHPs) represent one of practical solutions to effectively utilize fossil fuel energy and reduce environmental pollution. In this paper, the performance characteristics of the GEHP were investigated experimentally with engine heat recovery. A GEHP test facility was set up for this purpose. The effects of several important factors including engine speed, ambient temperature, condenser water flow rate, and condenser water inlet temperature on the system performance were studied over a wide range of operating conditions. The results showed that the engine waste heat accounted for about 40–50% of the total heat capacity over the studied operating conditions. It also showed that engine speed and ambient temperature had significant effects on the GEHP performance. The coefficient of performance (COP) and the primary energy ratio (PER) decreased by 14% and 12%, respectively, as engine speed increased from 1400 rpm to 2000 rpm. On the other hand, the COP and PER of the system increased by 22% and 16%, respectively, with the ambient temperature increasing from 3 to 12°C. Furthermore, it was demonstrated that the condenser water flow rate and condenser water inlet temperature had little influence on the COP of the heat pump and the PER of the GEHP system.


Energies ◽  
2020 ◽  
Vol 14 (1) ◽  
pp. 167
Author(s):  
Hasan Alimoradi ◽  
Madjid Soltani ◽  
Pooriya Shahali ◽  
Farshad Moradi Kashkooli ◽  
Razieh Larizadeh ◽  
...  

In this study, a numerical and empirical scheme for increasing cooling tower performance is developed by combining the particle swarm optimization (PSO) algorithm with a neural network and considering the packing’s compaction as an effective factor for higher accuracies. An experimental setup is used to analyze the effects of packing compaction on the performance. The neural network is optimized by the PSO algorithm in order to predict the precise temperature difference, efficiency, and outlet temperature, which are functions of air flow rate, water flow rate, inlet water temperature, inlet air temperature, inlet air relative humidity, and packing compaction. The effects of water flow rate, air flow rate, inlet water temperature, and packing compaction on the performance are examined. A new empirical model for the cooling tower performance and efficiency is also developed. Finally, the optimized performance conditions of the cooling tower are obtained by the presented correlations. The results reveal that cooling tower efficiency is increased by increasing the air flow rate, water flow rate, and packing compaction.


Author(s):  
Emin Yilmaz ◽  
Abhijit Nagchaudhuri

The goal of the design project titled “Domestic Hot Water Heater Using Air Conditioner Waste Heat” was to introduce students to designing mechanical systems in the “ETME475-Mechanical Systems Design” course. Two students completed the design project in spring 2007. Some test runs were conducted with a commercial desuperheater to measure the efficiency of the unit and its effect on the Coefficient of Performance (COP) of the Heat Pump when the heat pump is operated in air conditioning (A/C) mode. Contrary to author’s expectations, results indicated that, COP values were reduced by about 22%. Measured efficiency of the desuperheater was about 18% [1]. The current project is an extension of the original project with the new National Instruments data acquisition board, a newly developed LabVIEW data acquisition program, and with a more realistic heat transfer loop. The study covers performance of the heat pump operating in A/C mode as well as in heating mode. Results indicate, depending on the water temperature in the desuperheater, heat pump COP dropped 6–17% in A/C mode and 8–38% in heating mode. Again depending on the average water temperature in the ECU, the ECU efficiencies ranged from 12% to 27% for cooling and 11% to 39% for heating.


2020 ◽  
Vol 1008 ◽  
pp. 177-185
Author(s):  
Hamed Abbady ◽  
Mahmoud Salem Ahmed ◽  
Hamdy Hassan ◽  
A.S.A. Mohamed

In this paper, an experimental work studies the principal operating parameters of a proposed desalination process using air humidification-dehumidification method. The major objective of this work is to determine the humid air behavior through the desalination system. Different operating conditions including the effect of the water temperature at the entry to the humidifier, the ratio of the mass of water to the air, the air/water flow rate, and cooling water at entry the dehumidifier on the desalination performance were studied. The results show that the freshwater increases with increasing the water temperature at the inlet of the humidifier, the ratio of the mass of water to air, and cooling water flow rate in the dehumidifier. Cooling water outlet temperature at the condenser increases with increasing the water temperature at humidifier inlet. Also, it decreases as increasing cooling water flow rate while the ratio of the mass of water to air achieves the highest productivity and gained output ratio (GOR). The achieved mass ratio (MR) is 4.5 and the mass flow rate of air is 0.8 kg/min.


2011 ◽  
Vol 1 (2) ◽  
Author(s):  
I Made Rasta

Refrigerant in refrigeration machines will absorb heat from a room space and released the heat to the environment. The heat balancing in the system is heat released from condenser equal with heat absorbed from room space added by the heat equivalent from compressor work. Based on this heat cycle, the writer try to conduct research on using this heat rejection from condenser to heating tap water, focusing on water flow rate increased from 0.5 liter/min to 2.5 liter/min. From experiment and analysis result obtained that the maximum heat water temperature which can be reached is 47.5°C in 0.5 liter/min, with the equipment specifications are 2 HP- split air conditioning and the tank volume is 75 liters. The additional result is heating water temperature is fallen when the water flow rate is increased.


Author(s):  
Said Dini ◽  
Mohammad Khosrowjerdi ◽  
James Aflaki

This paper describes an effective, but simple, technique using a computer interface for control, data acquisition, and processing of a heat pump laboratory experiment. A water-to-air heat pump that allows comfort cooling and heating from a single source is used as an experiment and will be incorporated in a Mechanical Engineering Laboratory Course. Presently, the source is the city water. Plans are in place to use a ground source that provides a relatively constant temperature water supply, as low as 45°F. This well-instrumented laboratory teaching equipment allows students to measure temperatures, pressures, flow rate, and power input and then calculate the coefficient of performance of the system and the efficiency of the compressor both manually and automatically. A self-contained Windows-based data collection and analysis system has been developed for automating all the manual functions of a WPH-J Series Water-to-Air Heat Pump from Heat Controller, Inc. This system uses a data acquisition board to read the voltage signals corresponding to 9 T-type thermocouples, three pressure gauges, and compressor supplied power. The data acquisition and control software written in Visual Basic 6 uses 32-bit libraries to control the operation mode, read the thermocouples’ voltages, water flow rate, compressor’s input and output pressure, and supplied power.


Author(s):  
Michael J. Kazmierczak ◽  
Abhishek Gupta

Experiments were performed on a heat exchanger equipped with multiple thermoelectric (TE) modules. The TE-HX serves as the basic system component in a simple hydronic modular Peltier heat pump system designed to provide chilled or hot water for domestic use (or supplementary building climate control) of small residences [1]. The present work focuses on the detailed convection analysis inside the TE-HX component when 10 thermoelectric modules are utilized. The local heat transfer coefficient at different points along the channel are measured at steady-state, first, when a continuous heater is installed and then when replaced with 10 TE modules. The experimental heat transfer coefficients obtained are compared with available empirical correlations for “transition” (3000 < ReDh < 7000) turbulent flow inside the channel with fair-to-good results. Next, the resulting coefficient-of-performance of the TE heat pump system is measured with its value depending both on system input power and water flow rate. Testing showed that performance degradation, i.e. reduced COPs, occurred when operated at higher power levels but remains satisfactory for up to 688 Watts with higher flow rate.