scholarly journals Diagnostic accuracy of ultrasound in detection of pregnancy associated breast cancer

2021 ◽  
Vol 4 (1) ◽  
pp. 3-8
Author(s):  
Zainab Mehmood ◽  
Rafia Shahzad ◽  
Ismat Fatima ◽  
Abubaker Shahid

Introduction: Some unique physiological changes occur in breast volume and water content during pregnancy which makes the radiological evaluation of the breast difficult.  As a result, diagnosis of Pregnancy Associated Breast Cancer.  is often delayed. Objective: To find out the diagnostic accuracy of ultrasonography in detection of pregnancy associated breast cancer taking histopathology as gold standard. Methodology: Present Cross-sectional study was carried out at INMOL Hospital, Lahore. Ultrasound of 200 women was performed. The patient was laid supine and then turned slightly in oblique position to scan the breast with high frequency linear probe (7.5-10 MHz). The contra-lateral breast and both axillae were also scanned in the same way. Findings were categorized on the basis of Breast Imaging Reporting and Data System (BI-RADS) assessment categories. Subsequently the breast tissue was sent to histopathology laboratory for tissue diagnosis. The pathologist was blinded of the results of ultrasonography. Results: Mean age was 34 ± 11.36 years. Twenty-eight percent patients were primi-para while 72% patients were multi-para. Diagnostic accuracy of ultrasonography taking histopathology as gold standard was analyzed and ultrasonography had sensitivity 84.78%, specificity 98.05%, positive predictive value 92.85%, negative predictive value 95.56% and diagnostic accuracy was 95%. Invasive ductal carcinoma was most commonly observed (P<0.001) malignant histopathology. On the other hand, significantly high (P = 0.033) number of benign lesions were Fibroadenomas. Conclusion: The high sensitivity and specificity along with easy availability, and non-invasive nature makes ultrasonography a very useful technique for the diagnosis of Pregnancy Associated Breast Cancer.

2020 ◽  
Vol 36 (4) ◽  
Author(s):  
Hina Hanif ◽  
Sohail Ahmed Khan ◽  
Sobia Muneer ◽  
Syed Omair Adil

Objective: To evaluate the diagnostic accuracy of ultrasound in obstructive jaundice taking MRCP as gold standard. Methods: This cross-sectional study was conducted at Dow Institute of Radiology (DIR), Dow University of Health Sciences (DUHS), Karachi from 2nd May 2018 till 2nd November 2018. Both male and female patients aged 30 to 80 years with suspected obstructive jaundice were included. Patients already diagnosed with obstructive jaundice were excluded. MRCP and ultrasound were performed in suspected patients. Diagnostic accuracy including sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV) of obstructive jaundice were calculated using contingency tables using MRCP findings as gold standard. Results: Mean age of the patients was 54.73 ± 12.65 years. In causes of obstruction, choledocholothiasis was responsible for 85 (35.1%), stricture 61 (25.2%), carcinoma of head of pancreas 39 (16.1%), periampullary carcinoma 21 (8.7%), cholangiocarcinoma 10 (4.1%) and gallbladder carcinoma 26 (10.7%) of the cases. Diagnostic accuracy of ultrasound in obstructive jaundice taking MRCP findings as gold standard showed sensitivity, specificity, positive predicted value (PPV), negative predicted value (NPV) and overall diagnostic accuracy as 84.57%, 79.10%, 91.36%, 66.25% and 83.06%. Conclusion: Ultrasound has a high sensitivity, moderate specificity, and high diagnostic accuracy in diagnosis of obstructive jaundice. doi: https://doi.org/10.12669/pjms.36.4.1665 How to cite this:Hanif H, Khan SA, Muneer S, Adil SO. Diagnostic accuracy of ultrasound in evaluation of obstructive jaundice with MRCP as gold standard. Pak J Med Sci. 2020;36(4):---------. doi: https://doi.org/10.12669/pjms.36.4.1665 This is an Open Access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/3.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.


2021 ◽  
Vol 15 (6) ◽  
pp. 1679-1681
Author(s):  
Afaque Ali ◽  
Majid Shaikh ◽  
Ahsanullah . ◽  
Adeel Ahmed ◽  
Abid Ali Sahito ◽  
...  

Objective: To determine the diagnostic accuracy of High-resolution computed tomography (HRCT) chest in detection of covid-19 infection taking PCR as gold standard. Study Design: Cross-sectional study Setting: Radiology department of Tabba Hospital, Karachi. Duration: From March 2019 to September 2020 Material and Methods: All the clinically suspected patients of covid-19, of any age, both genders and those referred to radiology for High-resolution computed tomography (HRCT) chest to detect the covid-19 infection were included. After two days, patients’ PCR reports were collected from the ward, after taking informed consent and permission from head of department. The diagnostic accuracy of HRCT was established with respect to sensitivity, PPV, NPV, and specificity by taking PCR as gold standard. All the information was collected via study proforma. Results: Total 70 patients suspected for COVID-19 were studied, and the patients’ mean age was 58.23±9.52 years. Males were in majority 54(77.1%). As per HRCT findings, COVID-19 infection was positive in 46 patients, however, 48 patients were detected positive for COVID-19 infection as per PCR findings. In the detection of COVID-19 infection, HRCT chest showed sensitivity of 91%, specificity of 90%, PPV of 83%, NPV of 84% and diagnostic accuracy of 94%; by taking PCR as gold standard. Conclusion: High-resolution computed tomography (HRCT) is a reliable diagnostic approach in promptly detecting the COVID-19; with 91% sensitivity, 90% specificity, 83% positive predictive value, 84% negative predictive value and 94% diagnostic accuracy. Keywords: Accuracy, HRCT, COVID-19


2020 ◽  
Vol 37 (1) ◽  
Author(s):  
Sohbia Munir ◽  
Sohail Ahmed Khan ◽  
Hina Hanif ◽  
Maria Khan

Objective: To evaluate the diagnostic accuracy of magnetic resonance imaging (MRI) in detection of intra-axial gliomas in suspected cases keeping histopathology as gold standard. Methods: This cross-sectional study was conducted at Dow Institute of Radiology, DUHS from October 2017 - April 2018. Patients of either gender aged 30-70 years presenting with headache were included. Patients already diagnosed and referred for follow up were excluded. MRI was performed on 1.5T scanner by a trained MRI technician. T1, T2, FLAIR, diffusion weighted and T1 post contrast images were acquired and reviewed by two radiologists having more than five years post fellowship experience. Sensitivity, specificity, PPV, NPV and diagnostic accuracy of MRI for intraaxial gliomas was calculated taking histopathology findings as gold standard. Results: Mean age of the patient`s was 51.71 ±10.85 years. Positive intraaxial gliomas on MRI were observed in 123 (79.90%) patients while on histopathology, positive intraaxial gliomas were observed in 131 (85.10%) patients. Diagnostic accuracy of MRI in detection of intra-axial gliomas taking histopathology findings as gold standard showed sensitivity, specificity, positive predicted value (PPV), negative predicted value (NPV) and overall diagnostic accuracy as 89.31%, 73.91%, 95.12%, 54.84% and 87.01%. Conclusions: MRI has high sensitivity, moderate specificity and high diagnostic accuracy in detection of intraaxial gliomas. doi: https://doi.org/10.12669/pjms.37.1.2489 How to cite this:Munir S, Khan SA, Hanif H, Khan M. Diagnostic accuracy of magnetic resonance imaging in detection of intra-axial gliomas. Pak J Med Sci. 2021;37(1):125-130. doi: https://doi.org/10.12669/pjms.37.1.2489 This is an Open Access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/3.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.


Author(s):  
G Sindhujha Sekar ◽  
A Esther Ruby ◽  
P Lalitha

Introduction: In perimenopausal age group particularly, 70% of all gynaecological consultations are for Abnormal Uterine Bleeding (AUB). About 30% of women seek medical assistance for AUB during their reproductive age group and about one third of hysterectomies are carried out for AUB alone. Aim: To determine the sensitivity, specificity, positive predictive value and negative predictive value of Transvaginal Ultrasonography (TVS) versus hysteroscopy in detecting uterine abnormalities Materials and Methods: A cross-sectional study in patients with AUB, admitted to the Department of Obstetrics and Gynaecology at RGGWCH, Puducherry between February 2016 and February 2017 who met the inclusion criteria were included. Sample size was 85 cases. After taking detailed history and physical examination the patient was investigated to rule out organic causes of AUB and then TVS and hysteroscopy were done. Any intrauterine pathology was looked for and endometrial sampling was taken from the abnormal sites for Histopathological Examination (HPE). Both TVS and hysteroscopy results were compared with histopathology which is the gold standard. Results: The sensitivity of TVS in diagnosis of uterine fibroid in comparison to hysteroscopy was 94.74% and the specificity was 71.21%. The sensitivity of hysteroscopy in diagnosis of endometrial hyperplasia in comparison to HPE was 75% and the specificity was 87.01%. The sensitivity of TVS in diagnosis of endometrial hyperplasia in comparison to HPE was 37.5% and the specificity was 90.91%. The sensitivity of hysteroscopy in diagnosis of polyp in comparison to HPE was 100% and the specificity was 97.3%. The sensitivity and specificity of TVS in diagnosis of polyp in comparison to HPE were 9.09% and 93.24%, respectively. Conclusion: TVS had a high sensitivity to detect fibroids but its value in detecting hyperplasia and polyps was in question in this study. But hysteroscopy had a maximum sensitivity to detect polyps and high sensitivity to detect endometrial hyperplasia compared to histopathology which is a gold standard investigation.


2019 ◽  
Vol 6 (6) ◽  
pp. 2593
Author(s):  
Nayantara R. Gandra ◽  
Kalavathy Jasmine Masillamoni

Background: Even though there are many programs run by Government to tackle the problem of malnutrition in India, problem of malnutrition is still there. Malnutrition leads to infections and even can lead to death of child in severe cases. The mortality rate is very high compared to other countries. The objective of the study to study validity of age independent various nutritional status indices in comparison to gold standard of weight for ageMethods: Present study was institution based cross sectional study carried out at SDA high school, from January 2019 to July 2019 among 58 school children aged 34-92 months of age. Anthropometric measurements like weight, height, head circumference, chest circumference, mid arm circumference were recorded as per the standard guidelines. Weight for height, weight of age, Kanawati Index, Jeliffe’s ratio, Rao index, and Dugdales index was calculated. Gold standard used was weight for age. Sensitivity, specificity, positive predictive value and negative predictive value were calculated for these indices.Results: Majority of the children belonged to 48-60 months and 61-72 months i.e. 29.3% each. Males were more than females. Prevalence of malnutrition was 60.3%, 48.3%, 51.7%, 91.4%, and 56.8% based on weight for age, Kanawati index, Rao index, Jeliffe’s ratio and Dugdale’s index respectively. Dugdale’s index was found to have high sensitivity (85.7%) and specificity (86.9%) compared to all other indices.Conclusions: Among age independent indices of nutritional status available, Dugdales index can be used as it has been found that it has remarkably higher sensitivity and specificity compared to other age independent indices of nutritional status.


2014 ◽  
Vol 48 (6) ◽  
pp. 931-939 ◽  
Author(s):  
Flávio Xavier Silva ◽  
Leila Katz ◽  
Alex Sandro Rolland Souza ◽  
Melania Maria Ramos Amorim

OBJECTIVE To assess findings of mammography of and interventions resulting from breast cancer screening in women aged 40-49 years with no increased risk (typical risk) of breast cancer. METHODS This cross-sectional study evaluated women aged 40-49 years who underwent mammography screening in a mastology reference center in Recife, PE, Northeastern Brazil, between January 2010 and October 2011. Women with breast-related complaints, positive findings in the physical examination, or high risk of breast cancer were excluded. RESULTS The 1,000 mammograms performed were classified into the following Breast Imaging-Reporting and Data System (BI-RADS) categories BI-RADS 0, 232; BI-RADS 1, 294; BI-RADS 2, 294; BI-RADS 3, 16; BI-RADS 4A, 2; BI-RADS 5, 1. There was one case of grade II invasive ductal carcinoma and various interventions, including 469 ultrasound scans, 53 referrals to mastologists, 11 cytological examinations, and 8 biopsies. CONCLUSIONS Mammography screening in women aged 40-49 years with typical risk of breast cancer led to the performance of other interventions. However, it also resulted in increased costs without demonstrable efficacy in decreasing mortality.


Author(s):  
Abid Ali Sahito ◽  
. Ahsanullah ◽  
Vicky Kumar ◽  
Mohsim Hussain ◽  
Humaira Ashraf ◽  
...  

Objective: To determine the diagnostic accuracy of doppler ultrasound in the diagnosis of testicular carcinoma, by taking histopathology as gold standard. Methods: This cross-sectional study was carried out at Radiology department of Liaquat University of Medical and health Sciences (LUMHS), from November 2017 to October 2019. All the clinically diagnosed cases of testicular carcinoma, those who referred for doppler ultrasound and histopathology of testes, were included. After taking informed consent all the study participants underwent testicular histopathology after doppler ultrasound. All of the information was entered into a research proforma. SPSS version 20 was used to analyze the data. Results: Overall, 70 patients of suspected testicular carcinoma were studied. The mean age of the cases was 38.38+4.55 years. Most of the cases 47(67.1%) were poor. As per Doppler ultrasound (U/S) findings out of all 55.7% cases had diagnosed testicular carcinoma, while histopathologically it was observed in 45.7% of the cases. Diagnostic accuracy of Doppler U/S in testicular carcinoma diagnosis was observed to be 77%, followed by sensitivity (SE) 84%, specificity (SP) 71%, positive predictive value (PPV) 78% and negative predictive value (NPV) 84%. Conclusion: Doppler ultrasound observed to be a non-invasive, uncomplicated, lack of pain, effective and easily available diagnostic tool for early diagnosis of testicular carcinoma.


2019 ◽  
Vol 7 (1) ◽  
pp. 144
Author(s):  
Shahaji G. Chavan ◽  
Sree Ganesh B. ◽  
Nandan Vemuri

Background: Breast cancer incidence in India is increasing and has now become the most common cancer among women. Preoperative pathology diagnosis and mammography (using breast imaging reporting and data system      (BI-RADS) scoring system) constitute an essential part of the workup of breast lesions. The present study was aimed to compare the diagnostic accuracy of BI-RADS score with histopathological finding in diagnosis of benign and malignant lesions of breast.Methods: This is a cross-sectional study. The present study was conducted on 100 randomly selected newly diagnosed cases of breast lump attending the General Surgery Department (OPD).Results: Considering histopathological examination as gold standard, the sensitivity and specificity of BI-RADS score is 93.9% and 82.3% respectively. The positive predictive value, negative predictive value and diagnostic accuracy of BI-RADS score is 91.1%, 87.5% and 90.0% respectively.Conclusions: Author conclude from the present study that BI-RADS score being non-invasive, it may become a very useful test for evaluating Breast lump lesions. However, BI-RADS score cannot be considered as gold standard and thus cannot be used as an alternative to histopathology in diagnosis of breast lumps.


2014 ◽  
Vol 47 (2) ◽  
pp. 74-78 ◽  
Author(s):  
Gustavo Machado Badan ◽  
Décio Roveda Júnior ◽  
Carlos Alberto Pecci Ferreira ◽  
Ozeas Alves de Noronha Junior

Objective Undertaking of a complete audit of the service of mammography, as recommended by BI-RADS®, in a private reference institution for breast cancer diagnosis in the city of São Paulo, SP, Brazil, and comparison of results with those recommended by the literature. Materials and Methods Retrospective, analytical and cross-sectional study including 8,000 patients submitted to mammography in the period between April 2010 and March 2011, whose results were subjected to an internal audit. The patients were followed-up until December 2012. Results The radiological classification of 7,249 screening mammograms, according to BI-RADS, was the following: category 0 (1.43%), 1 (7.82%), 2 (80.76%), 3 (8.35%), 4 (1.46%), 5 (0.15%) and 6 (0.03%). The breast cancer detection ratio was 4.8 cases per 1,000 mammograms. Ductal carcinoma in situ was found in 22.8% of cases. Positive predictive values for categories 3, 4 and 5 were 1.3%, 41.3% and 100%, respectively. In the present study, the sensitivity of the method was 97.1% and specificity, 97.4%. Conclusion The complete internal audit of a service of mammography is essential to evaluate the quality of such service, which reflects on an early breast cancer detection and reduction of mortality rates.


Diagnostics ◽  
2020 ◽  
Vol 10 (12) ◽  
pp. 1011
Author(s):  
Sofia Nevander ◽  
Eva Landberg ◽  
Marie Blomberg ◽  
Bertil Ekman ◽  
Caroline Lilliecreutz

Gestational diabetes mellitus (GDM) is a common complication with negative impacts on mother and child. The primary aim of this study was to examine whether plasma glucose cutoffs for GDM diagnosis based on venous sampling can be replaced by cutoffs based on capillary sampling. A prospective cross-sectional study was performed at an antenatal care clinic including 175 pregnant women undergoing an oral glucose tolerance test (OGTT). Duplicate samples were collected by capillary and venous puncture while fasting and 1 h and 2 h after an OGTT. Both samples were analyzed on Accu-Chek Inform II. The cutoffs for a GDM diagnosis using capillary samples were corrected from 5.1 to 5.3 mmol/L for the fasting sample, from 10.0 to 11.1 mmol/L for the 1 h sample, and from 8.5 to 9.4 mmol/L for the 2-h sample using half of the dataset. Applying these cutoffs to the remaining dataset resulted in a sensitivity, specificity, and accuracy of 85.0%, 95.0%, and 90.3%, respectively, with a positive predictive value (PPV) of 83%, an negative predictive value (NPV) of 96%, and a positive negative likelihood ratio (LHR) of 16.4 using capillary sampling for the GDM diagnosis at fasting and 2-h after. Corrected cutoffs and capillary samples can be used for the diagnosis of GDM with maintained diagnostic accuracy using Accu-Chek Inform II.


Sign in / Sign up

Export Citation Format

Share Document