scholarly journals 3D printed phantom to mimic dynamic softening of cervix during pre-labour

2021 ◽  
Author(s):  
Jung S. Kim

It is thought that through the development of more realistic training models for midwives and obstetricians it may be possible to reduce the overuse of labour induction. To this end we demonstrate a method for creating pneumatically-controlled phantom cervixes using thermoplastic elastomer, filled with a granular material. The maximum spring constant of the phantom cervix was measured to be 10.5 N/m at -20 kPa deflated air (vacuum) and the minimum spring constant measured was 5.3 N/m at 20 kPa inflated air. The true stress measured on these elastomeric phantom cervixes indicated a maximum stress of 133 kPa and a minimum stress of 94 kPa at 0.15 strain. Discrimination and threshold tests demonstrated that people can distinguish between the hard and soft states of the phantom. Future work will focus on increasing the softness of these devices.

2021 ◽  
Author(s):  
Jung S. Kim

It is thought that through the development of more realistic training models for midwives and obstetricians it may be possible to reduce the overuse of labour induction. To this end we demonstrate a method for creating pneumatically-controlled phantom cervixes using thermoplastic elastomer, filled with a granular material. The maximum spring constant of the phantom cervix was measured to be 10.5 N/m at -20 kPa deflated air (vacuum) and the minimum spring constant measured was 5.3 N/m at 20 kPa inflated air. The true stress measured on these elastomeric phantom cervixes indicated a maximum stress of 133 kPa and a minimum stress of 94 kPa at 0.15 strain. Discrimination and threshold tests demonstrated that people can distinguish between the hard and soft states of the phantom. Future work will focus on increasing the softness of these devices.


Circulation ◽  
2020 ◽  
Vol 142 (Suppl_3) ◽  
Author(s):  
Matthew H Park ◽  
Annabel Imbrie-moore ◽  
Yuanjia Zhu ◽  
Hanjay Wang ◽  
Michael J Paulsen ◽  
...  

Introduction: Advances in ex vivo heart simulation have enabled the study of valvular biomechanics, disease pathologies, and repair strategies. However, these simulators test the valves in isolation, which does not fully replicate in vivo physiology. We hypothesize that by engineering a simulator that preserves the aortomitral junction, we can better recreate pathophysiologies such as systolic anterior motion (SAM). Here, we present a new heart simulator that preserves and manipulates the native aortomitral physiology. Methods: Our simulator is comprised of three subsystems: the ventricular chamber, atrial chamber, and aortic chamber (Fig A, B). The heart is excised at the apex to preserve the papillary muscles, and the left ventricle, atrial cuff, and aorta are fixed to their respective chambers via hemostatic suturing to 3D-printed elastomeric rings. The chambers are equipped with pressure and flow sensors, and a linear piston pump generates physiologic pressures and flows. The atrial and aortic chambers are mounted on 5-degree-of-freedom arms. To demonstrate system function, we manipulated the aortomitral angle and measured aortic cardiac output. Results: In our testing, we evaluated two unique configurations of an explanted porcine heart, of which the aortomitral angles spanned the SAM predictive risk threshold of <120° (Fig C, D). From the flow readings, we measured a 36% reduction in aortic cardiac output upon decreasing the aortomitral angle by 25°. Conclusions: This work highlights the design and development of an ex vivo heart simulator capable of modeling native aortomitral physiology. Our results point to a clear direction for future experimentation, particularly evaluating the biomechanical changes of the heart based on the aortomitral angle. Future work will utilize this platform to create new models and repair techniques to ultimately improve clinical care of valvular pathologies.


2021 ◽  
Vol 2021 ◽  
pp. 1-9
Author(s):  
Aolin Che ◽  
Yalin Liu ◽  
Hong Xiao ◽  
Hao Wang ◽  
Ke Zhang ◽  
...  

In the past decades, due to the low design cost and easy maintenance, text-based CAPTCHAs have been extensively used in constructing security mechanisms for user authentications. With the recent advances in machine/deep learning in recognizing CAPTCHA images, growing attack methods are presented to break text-based CAPTCHAs. These machine learning/deep learning-based attacks often rely on training models on massive volumes of training data. The poorly constructed CAPTCHA data also leads to low accuracy of attacks. To investigate this issue, we propose a simple, generic, and effective preprocessing approach to filter and enhance the original CAPTCHA data set so as to improve the accuracy of the previous attack methods. In particular, the proposed preprocessing approach consists of a data selector and a data augmentor. The data selector can automatically filter out a training data set with training significance. Meanwhile, the data augmentor uses four different image noises to generate different CAPTCHA images. The well-constructed CAPTCHA data set can better train deep learning models to further improve the accuracy rate. Extensive experiments demonstrate that the accuracy rates of five commonly used attack methods after combining our preprocessing approach are 2.62% to 8.31% higher than those without preprocessing approach. Moreover, we also discuss potential research directions for future work.


2006 ◽  
Vol 315-316 ◽  
pp. 637-640
Author(s):  
Li Li Liu ◽  
Jian Xin Deng ◽  
Jun Zhou

The stress states of the ceramic nozzle in abrasive jet machining (AJM) process are analyzed. Results shown that the maximum stress appears in entrance area of the nozzle and minimum stress in middle area, while the stress of exit area was lower than entrance area and higher than middle area. It can interprets why the entrance and exit area of the nozzle were worn badly. The idea of functionally gradient material (FGM) theory was used to design of ceramic nozzle. The purpose was to reduce the stresses at the entrance and exit area of the nozzle during AJM processes. The physical, composition distribution, and property parameter models of the FGM nozzle were established.


Author(s):  
Marcel Hanisch ◽  
Elke Kroeger ◽  
Markus Dekiff ◽  
Maximilian Timme ◽  
Johannes Kleinheinz ◽  
...  

Background: Most simulation models used at university dental clinics are typodonts. Usually, models show idealized eugnathic situations, which are rarely encountered in everyday practice. The aim of this study was to use 3D printing technology to manufacture individualized surgical training models for root tip resection (apicoectomy) on the basis of real patient data and to compare their suitability for dental education against a commercial typodont model. Methods: The training model was designed using CAD/CAM (computer-aided design/computer-aided manufacturing) technology. The printer used to manufacture the models employed the PolyJet technique. Dental students, about one year before their final examinations, acted as test persons and evaluated the simulation models on a visual analogue scale (VAS) with four questions (Q1–Q4). Results: A training model for root tip resection was constructed and printed employing two different materials (hard and soft) to differentiate anatomical structures within the model. The exercise was rated by 35 participants for the typodont model and 33 students for the 3D-printed model. Wilcoxon rank sum tests were carried out to identify differences in the assessments of the two model types. The alternative hypothesis for each test was: “The rating for the typodont model is higher than that for the 3D-printed model”. As the p-values reveal, the alternative hypothesis has to be rejected in all cases. For both models, the gingiva mask was criticized. Conclusions: Individual 3D-printed surgical training models based on real patient data offer a realistic alternative to industrially manufactured typodont models. However, there is still room for improvement with respect to the gingiva mask for learning surgical incision and flap formation.


2017 ◽  
Vol 21 (6) ◽  
Author(s):  
Jingyi Wang ◽  
Carlton McMullen ◽  
Ping Yao ◽  
Niandong Jiao ◽  
Min Kim ◽  
...  

2021 ◽  
Vol 13 (2) ◽  
pp. 57-61
Author(s):  
Alireza Izadi ◽  
Fariboorz Vafaie ◽  
Armaghan Shahbazi ◽  
Mohamad Taghi Mokri vala

Background: This finite element analysis (FEA) evaluated stress distribution in implant-supported overdenture (ISO) and peri-implant bone using one extracoronal (ball) and two intracoronal (locator and Zest Anchor Advanced Generation (ZAAG)) attachment systems. Methods: In this in vitro study, the mandible was modelled in the form of an arc-shaped bone block with 33 mm height and 8 mm width. Two titanium implants were modelled at the site of canine teeth, and three attachments (ZAGG, locator, and ball) were placed over them. Next, 100 N load was applied at 90° and 30° angles from the molar site of each quadrant to the implants. The stress distribution pattern in the implants and the surrounding bone was analyzed, and the von Mises stress around the implants and in the crestal bone was calculated. Results: While minimum stress in peri-implant bone following load application at 30° angle was noted in the mesial point of the locator attachment, maximum stress was recorded at the distal point of the ball attachment following load application at 90° angle. Maximum stress around the implant following load application at 90° angle was noted in the lingual point of the ball attachment while minimum stress was recorded in the lingual point of the locator attachment following load application at 90° angle. Conclusions: According to the results, the locator attachment is preferred to the ZAAG attachment, and the ball attachment should be avoided if possible.


2021 ◽  
Vol 7 (1) ◽  
Author(s):  
Kristin M. Fischer ◽  
Andrew P. Howell

AbstractHealth care waste can be a costly expenditure for facilities as specific disposal methods must be used to prevent the spread of pathogens. If more multi-use medical devices were available, it could potentially relieve some of this burden; however, sterilization between uses is important in preventing disease transmission. 3D printing has the ability to easily create custom medical devices at a low cost, but the majority of filaments utilized cannot survive steam sterilization. Polypropylene (PP) can withstand autoclave temperatures, but is difficult to print as it warps and shrinks during printing; however, a composite PP filament reduces these effects. Commercially available PP and glass filled PP (GFPP) filaments were successfully 3D printed into 30 × 30 × 30 mm cubes with no shrinking or warping and were autoclaved. The 134 °C autoclave temperature was too high as several cubes melted after two to three rounds, but both PP and GFPP cubes displayed minimal changes in mass and volume after one, four, seven, and ten rounds of autoclaving at 121 °C. GFPP cubes autoclaved zero, four, seven, and ten times had significantly smaller average compressive stress values compared to all PP groups, but the GFPP cubes autoclaved once were only less than PP cubes autoclaved zero, seven and ten times. GFPP cubes autoclaved zero, one, four, and seven times also deformed less indicating that the embedded glass fibers provided additional strength. While a single method was found that successfully printed PP and GFPP cubes that were able to survive up to ten rounds of autoclaving, future work should include further investigation into the mechanical properties and increasing the number of autoclave rounds.


Polymers ◽  
2020 ◽  
Vol 12 (6) ◽  
pp. 1224 ◽  
Author(s):  
Namsoo Peter Kim

3D printable, flexible, and conductive composites are prepared by incorporating a thermoplastic elastomer and electrically conductive carbon fillers. The advantageous printability, workability, chemical resistance, electrical conductivity, and biocompatibility components allowed for an enabling of 3D-printed electronics, electromagnetic interference (EMI) shielding, static elimination, and biomedical sensors. Carbon-infused thermoplastic polyurethane (C/TPU) composites have been demonstrated to possess right-strained sensing abilities and are the candidate in fields such as smart textiles and biomedical sensing. Flexible and conductive composites were prepared by a mechanical blending of biocompatible TPU and carbons. 3D structures that exhibit mechanical flexibility and electric conductivity were successfully printed. Three different types of C/TPU composites, carbon nanotube (CNT), carbon black (CCB), and graphite (G) were prepared with differentiating sizes and composition of filaments. The conductivity of TPU/CNT and TPU/CCB composite filaments increased rapidly when the loading amount of carbon fillers exceeded the filtration threshold of 8%–10% weight. Biocompatible G did not form a conductive pathway in the TPU; resistance to indentation deformation of the TPU matrix was maintained by weight by 40%. Adding a carbon material to the TPU improved the mechanical properties of the composites, and carbon fillers could improve electrical conductivity without losing biocompatibility. For the practical use of the manufactured filaments, optimal printing parameters were determined, and an FDM printing condition was adjusted. Through this process, a variety of soft 3D-printed C/TPU structures exhibiting flexible and robust features were built and tested to investigate the performance of the possible application of 3D-printed electronics and medical scaffolds.