scholarly journals Reusability of autoclaved 3D printed polypropylene compared to a glass filled polypropylene composite

2021 ◽  
Vol 7 (1) ◽  
Author(s):  
Kristin M. Fischer ◽  
Andrew P. Howell

AbstractHealth care waste can be a costly expenditure for facilities as specific disposal methods must be used to prevent the spread of pathogens. If more multi-use medical devices were available, it could potentially relieve some of this burden; however, sterilization between uses is important in preventing disease transmission. 3D printing has the ability to easily create custom medical devices at a low cost, but the majority of filaments utilized cannot survive steam sterilization. Polypropylene (PP) can withstand autoclave temperatures, but is difficult to print as it warps and shrinks during printing; however, a composite PP filament reduces these effects. Commercially available PP and glass filled PP (GFPP) filaments were successfully 3D printed into 30 × 30 × 30 mm cubes with no shrinking or warping and were autoclaved. The 134 °C autoclave temperature was too high as several cubes melted after two to three rounds, but both PP and GFPP cubes displayed minimal changes in mass and volume after one, four, seven, and ten rounds of autoclaving at 121 °C. GFPP cubes autoclaved zero, four, seven, and ten times had significantly smaller average compressive stress values compared to all PP groups, but the GFPP cubes autoclaved once were only less than PP cubes autoclaved zero, seven and ten times. GFPP cubes autoclaved zero, one, four, and seven times also deformed less indicating that the embedded glass fibers provided additional strength. While a single method was found that successfully printed PP and GFPP cubes that were able to survive up to ten rounds of autoclaving, future work should include further investigation into the mechanical properties and increasing the number of autoclave rounds.

2017 ◽  
Vol 61 (4) ◽  
pp. 282 ◽  
Author(s):  
Bence Rochlitz ◽  
Dávid Pammer

3D printing manufacturing process has the possibilities to produce individual medical devices, especially implants and prosthesis with short production time. The aim of this study is to design a 3D printable Energy Storage and Return (ESAR) foot prosthesis for transtibial amputees with a novel geometry. The criteria of the prosthesis were 3D printable, low cost, simply geometry and satisfying mechanical properties for low activity use. The finite element analysis of the designed foot prosthesis was conducted in each of the three support phases of the walking cycle (controlled plantarflexion, controlled dorsiflexion, powered plantarflexion or push-off phase). Besides of the simulations the prototype was printed by fused deposit modeling (FDM) technology, used ABS material and the produced prototype was investigated in quasi-static and cyclic compression. It can be stated after the investigation (simulation and test) that the 3D printed prototype fulfill the requirements and it can be used as passive ESAR foot prosthesis.


Author(s):  
Philip Chung ◽  
J. Alex Heller ◽  
Mozziyar Etemadi ◽  
Paige E. Ottoson ◽  
Jonathan A. Liu ◽  
...  

2020 ◽  
Author(s):  
Merel van der Stelt ◽  
Martin P. Grobusch ◽  
Abdul R. Koroma ◽  
Marco Papenburg ◽  
Ismaila Kebbie ◽  
...  

2020 ◽  
Vol 27 (10) ◽  
pp. 1616-1633 ◽  
Author(s):  
Oana Cristina Duta ◽  
Aurel Mihail Ţîţu ◽  
Alexandru Marin ◽  
Anton Ficai ◽  
Denisa Ficai ◽  
...  

Polymeric materials, due to their excellent physicochemical properties and versatility found applicability in multiples areas, including biomaterials used in tissue regeneration, prosthetics (hip, artificial valves), medical devices, controlled drug delivery systems, etc. Medical devices and their applications are very important in modern medicine and the need to develop new materials with improved properties or to improve the existent materials is increasing every day. Numerous reasearches are activated in this domain in order to obtain materials/surfaces that does not have drawbacks such as structural failure, calcifications, infections or thrombosis. One of the most used material is poly(vinylchloride) (PVC) due to its unique properties, availability and low cost. The most common method used for obtaining tubular devices that meet the requirements of medical use is the surface modification of polymers without changing their physical and mechanical properties, in bulk. PVC is a hydrophobic polymer and therefore many research studies were conducted in order to increase the hydrophilicity of the surface by chemical modification in order to improve biocompatibility, to enhance wettability, reduce friction or to make lubricious or antimicrobial coatings. Surface modification of PVC can be achieved by several strategies, in only one step or, in some cases, in two or more steps by applying several techniques consecutively to obtain the desired modification / performances. The most common processes used for modifying the surface of PVC devices are: plasma treatment, corona discharge, chemical grafting, electric discharge, vapour deposition of metals, flame treatment, direct chemical modification (oxidation, hydrolysis, etc.) or even some physical modification of the roughness of the surface.


Sensors ◽  
2021 ◽  
Vol 21 (6) ◽  
pp. 1977
Author(s):  
Ricardo Oliveira ◽  
Liliana M. Sousa ◽  
Ana M. Rocha ◽  
Rogério Nogueira ◽  
Lúcia Bilro

In this work, we demonstrate for the first time the capability to inscribe long-period gratings (LPGs) with UV radiation using simple and low cost amplitude masks fabricated with a consumer grade 3D printer. The spectrum obtained for a grating with 690 µm period and 38 mm length presented good quality, showing sharp resonances (i.e., 3 dB bandwidth < 3 nm), low out-of-band loss (~0.2 dB), and dip losses up to 18 dB. Furthermore, the capability to select the resonance wavelength has been demonstrated using different amplitude mask periods. The customization of the masks makes it possible to fabricate gratings with complex structures. Additionally, the simplicity in 3D printing an amplitude mask solves the problem of the lack of amplitude masks on the market and avoids the use of high resolution motorized stages, as is the case of the point-by-point technique. Finally, the 3D printed masks were also used to induce LPGs using the mechanical pressing method. Due to the better resolution of these masks compared to ones described on the state of the art, we were able to induce gratings with higher quality, such as low out-of-band loss (0.6 dB), reduced spectral ripples, and narrow bandwidths (~3 nm).


HardwareX ◽  
2021 ◽  
pp. e00214
Author(s):  
David T. McCarthy ◽  
Baiqian Shi ◽  
Miao Wang ◽  
Stephen Catsamas
Keyword(s):  
Low Cost ◽  

2021 ◽  
Vol 14 (1) ◽  
Author(s):  
Fiona Teltscher ◽  
Sophie Bouvaine ◽  
Gabriella Gibson ◽  
Paul Dyer ◽  
Jennifer Guest ◽  
...  

Abstract Background Mosquito-borne diseases are a global health problem, causing hundreds of thousands of deaths per year. Pathogens are transmitted by mosquitoes feeding on the blood of an infected host and then feeding on a new host. Monitoring mosquito host-choice behaviour can help in many aspects of vector-borne disease control. Currently, it is possible to determine the host species and an individual human host from the blood meal of a mosquito by using genotyping to match the blood profile of local inhabitants. Epidemiological models generally assume that mosquito biting behaviour is random; however, numerous studies have shown that certain characteristics, e.g. genetic makeup and skin microbiota, make some individuals more attractive to mosquitoes than others. Analysing blood meals and illuminating host-choice behaviour will help re-evaluate and optimise disease transmission models. Methods We describe a new blood meal assay that identifies the sex of the person that a mosquito has bitten. The amelogenin locus (AMEL), a sex marker located on both X and Y chromosomes, was amplified by polymerase chain reaction in DNA extracted from blood-fed Aedes aegypti and Anopheles coluzzii. Results AMEL could be successfully amplified up to 24 h after a blood meal in 100% of An. coluzzii and 96.6% of Ae. aegypti, revealing the sex of humans that were fed on by individual mosquitoes. Conclusions The method described here, developed using mosquitoes fed on volunteers, can be applied to field-caught mosquitoes to determine the host species and the biological sex of human hosts on which they have blood fed. Two important vector species were tested successfully in our laboratory experiments, demonstrating the potential of this technique to improve epidemiological models of vector-borne diseases. This viable and low-cost approach has the capacity to improve our understanding of vector-borne disease transmission, specifically gender differences in exposure and attractiveness to mosquitoes. The data gathered from field studies using our method can be used to shape new transmission models and aid in the implementation of more effective and targeted vector control strategies by enabling a better understanding of the drivers of vector-host interactions.


Materials ◽  
2021 ◽  
Vol 14 (2) ◽  
pp. 376
Author(s):  
Mao Kaneko ◽  
Masanori Hiratsuka ◽  
Ali Alanazi ◽  
Hideki Nakamori ◽  
Kazushige Namiki ◽  
...  

We evaluated the adhesion, friction characteristics, durability against bodily acids, sterilization, cleaning, and anti-reflection performance of diamond-like carbon (DLC) coatings formed as a surface treatment of intracorporeal medical devices. The major coefficients of friction during intubation in a living body in all environments were lower with DLC coatings than with black chrome plating. DLC demonstrated an adhesion of approximately 24 N, which is eight times stronger than that of black chrome plating. DLC-coated samples also showed significant stability without being damaged during acid immersion and high-pressure steam sterilization, as suggested by the results of durability tests. In addition, the coatings remained unpeeled in a usage environment, and there was no change in the anti-reflection performance of the DLC coatings. In summary, DLC coatings are useful for improving intracorporeal device surfaces and extending the lives of medical devices.


Author(s):  
Romain Nicot ◽  
Edwige Hurteloup ◽  
Sébastien Joachim ◽  
Charles Druelle ◽  
Jean-Marc Levaillant

Polymers ◽  
2021 ◽  
Vol 13 (15) ◽  
pp. 2518
Author(s):  
Nunzio Cennamo ◽  
Lorena Saitta ◽  
Claudio Tosto ◽  
Francesco Arcadio ◽  
Luigi Zeni ◽  
...  

In this work, a novel approach to realize a plasmonic sensor is presented. The proposed optical sensor device is designed, manufactured, and experimentally tested. Two photo-curable resins are used to 3D print a surface plasmon resonance (SPR) sensor. Both numerical and experimental analyses are presented in the paper. The numerical and experimental results confirm that the 3D printed SPR sensor presents performances, in term of figure of merit (FOM), very similar to other SPR sensors made using plastic optical fibers (POFs). For the 3D printed sensor, the measured FOM is 13.6 versus 13.4 for the SPR-POF configuration. The cost analysis shows that the 3D printed SPR sensor can be manufactured at low cost (∼15 €) that is competitive with traditional sensors. The approach presented here allows to realize an innovative SPR sensor showing low-cost, 3D-printing manufacturing free design and the feasibility to be integrated with other optical devices on the same plastic planar support, thus opening undisclosed future for the optical sensor systems.