scholarly journals Effect of Types of Weir on Discharge

2014 ◽  
Vol 5 (2) ◽  
pp. 35-40
Author(s):  
L L Caroline ◽  
Nasser R Afshar

 The measurement of discharge is one of the main concerns in hydraulic engineering. The study of types of weir on discharge is important as the knowledge of the accurate measurement of discharges helps in understanding of the flow mechanism as well as designing the hydraulic structures for future. Structures such as rectangular weir, vee notch weir and crump weir are placed in a channel to measure the flow rate. By using Bernoulli’s equation, weir equation are derived and used to determine the flow rate. The main objective is to determine the optimum discharge for different types of weirs. This discharge is important in designing the hydraulic structure. Overestimated discharge may cause failure to the structure and if the discharge is underestimated, it may not fulfill the design requirements. The studies are experimented from maximum flow to minimum flow by measuring head over the weir for different working sections; flat and slope of 1:2400 and different height of partially opened sluice gate of 4cm and 6cm for crump drowned condition. The result shows that the coefficient of discharge, Cd decreases when the head of water above the crest increases; except for crump weir in which Cd is independent of the head. Meanwhile, the velocities when slope is 1:2400 are higher as compared to flat.

2015 ◽  
Vol 137 (2) ◽  
Author(s):  
Marwan F. Al-Rjoub ◽  
Ajit K. Roy ◽  
Sabyasachi Ganguli ◽  
Rupak K. Banerjee

A new design for an electro-osmotic flow (EOF) driven micropump was fabricated. Considering thermal management applications, three different types of micropumps were tested using multiple liquids. The micropumps were fabricated from a combination of materials, which included: silicon-polydimethylsiloxane (Si-PDMS), Glass-PDMS, or PDMS-PDMS. The flow rates of the micropumps were experimentally and numerically assessed. Different combinations of materials and liquids resulted in variable values of zeta-potential. The ranges of zeta-potential for Si-PDMS, Glass-PDMS, and PDMS-PDMS were −42.5–−50.7 mV, −76.0–−88.2 mV, and −76.0–−103.0 mV, respectively. The flow rates of the micropumps were proportional to their zeta-potential values. In particular, flow rate values were found to be linearly proportional to the applied voltages below 500 V. A maximum flow rate of 75.9 μL/min was achieved for the Glass-PDMS micropump at 1 kV. At higher voltages nonlinearity and reduction in flow rate occurred due to Joule heating and the axial electro-osmotic current leakage through the silicon substrate. The fabricated micropumps could deliver flow rates, which were orders of magnitude higher compared to the previously reported values for similar size micropumps. It is expected that such an increase in flow rate, particularly in the case of the Si-PDMS micropump, would lead to enhanced heat transfer for microchip cooling applications as well as for applications involving micrototal analysis systems (μTAS).


2020 ◽  
Vol 19 (2) ◽  
pp. 64-68
Author(s):  
Mrinmoy Biswas ◽  
Sudip Das Gupta ◽  
Mohammed Mizanur Rahman ◽  
Sharif Mohammad Wasimuddin

Objective: To assess the success of BMG urethroplasty in long segment anterior urethral stricture. Method: From January 2014 to December 2015, twenty male patients with long anterior segment urethral stricture were managed by BMG urethroplasty. After voiding trial they were followed up at 3 month with Uroflowmetry, RGU & MCU and PVR measurement by USG. Patients were further followed up with Uroflowmetry and PVR at 6 months interval.Successful outcome was defined as normal voiding with a maximum flow rate >15ml /sec and PVR<50 ml with consideration of maximum one attempt of OIU after catheter removal. Results: Mean stricture length was 5.2 cm (range 3-9 cm) and mean follow-up was 15.55 months (range 6-23 months). Only two patients developed stricture at proximal anastomotic site during follow-up. One of them voided normally after single attempt of OIU. Other one required second attempt of OIU and was considered as failure (5%). Conclusion: BMG urethroplasty is a simple technique with good surgical outcome. Bangladesh Journal of Urology, Vol. 19, No. 2, July 2016 p.64-68


Author(s):  
Yuchuan Zhu ◽  
Chang Liu ◽  
Yunze Song ◽  
Long Chen ◽  
Yulei Jiang ◽  
...  

In this paper, an electro-hydrostatic actuator driven by dual axial-mounted magnetostrictive material rods-based pumps (MMPs) with a new type of active rectification valve is designed in the current study. Based on flow distribution of the active rectification valve and driving energy provided by two MMPs, the actuator can output continuous and bidirectional displacement. By establishing a mathematical model of the actuating system, using simulation techniques, the change rule of hydraulic cylinder’s motion state caused by different driving signals are studied and analyzed. Test equipment platform is constructed in the laboratory to test the output characteristics and confirm the feasibility of the new concept. The experimental results indicate that the maximum flow rate can reach approximately 2.7 L·min−1, while the operating frequency is 180 Hz.


2021 ◽  
pp. 039156032110033
Author(s):  
Atef Fathi ◽  
Omar Mohamed ◽  
Osama Mahmoud ◽  
Gamal A Alsagheer ◽  
Ahmed M Reyad ◽  
...  

Background: Substitution urethroplasty using buccal mucosal grafts can be performed by several approaches including ventral onlay graft, dorsal onlay graft, or ventral urethrotomy with dorsal inlay graft. Our study aims to evaluate the surgical outcome of dorsolateral buccal mucosal graft for long segment anterior urethral stricture >6 cm in patients with Lichen sclerosus (LS). Methods: A retrospective study included patients who underwent repair for long segment anterior urethral stricture >6 cm due to LS between January 2013 and April 2019. All patients were followed-up at 3, 6, 9, and 12 months postoperatively and then yearly by clinical symptoms, uroflowmetry, and calculation of post-void residual urine volume. Retrograde urethrogram was requested for patients with voiding symptoms or decreased maximum flow rate. Stricture recurrence that required subsequent urethrotomy or urethroplasty was considered failure. The success rate and surgical complications were collected and analyzed. Results: Thirty patients were identified. The median age (range) was 39 (25–61) years and a median (range) stricture length was 8 (6–14) cm. Most of postoperative complications were of minor degree. The success rate at median follow-up of 15 (12–24) months was 86.5%. The median maximum flow rate increased significantly from 6 (2–11) ml/s preoperatively to 18 (range: 6–23) ml/s at the 6th month ( p value < 0.001). Conclusion: Dorsolateral buccal mucosal grafts urethroplasty for long anterior urethral stricture caused by LS has a high success rate and low risk of complications including stricture recurrence.


Micromachines ◽  
2021 ◽  
Vol 12 (5) ◽  
pp. 500
Author(s):  
Jian Chen ◽  
Wenzhi Gao ◽  
Changhai Liu ◽  
Liangguo He ◽  
Yishan Zeng

This study proposes the improvement of the output performance of a resonant piezoelectric pump by adding proof masses to the free ends of the prongs of a U-shaped piezoelectric resonator. Simulation analyses show that the out-of-phase resonant frequency of the developed resonator can be tuned more efficiently within a more compact structure to the optimal operating frequency of the check valves by adjusting the thickness of the proof masses, which ensures that both the resonator and the check valves can operate at the best condition in a piezoelectric pump. A separable prototype piezoelectric pump composed of the proposed resonator and two diaphragm pumps was designed and fabricated with outline dimensions of 30 mm × 37 mm × 54 mm. Experimental results demonstrate remarkable improvements in the output performance and working efficiency of the piezoelectric pump. With the working fluid of liquid water and under a sinusoidal driving voltage of 298.5 Vpp, the miniature pump can achieve the maximum flow rate of 2258.9 mL/min with the highest volume efficiency of 77.1% and power consumption of 2.12 W under zero backpressure at 311/312 Hz, and the highest backpressure of 157.3 kPa under zero flow rate at 383 Hz.


1965 ◽  
Vol 87 (1) ◽  
pp. 134-141 ◽  
Author(s):  
F. J. Moody

A theoretical model is developed for predicting the maximum flow rate of a single component, two-phase mixture. It is based upon annular flow, uniform linear velocities of each phase, and equilibrium between liquid and vapor. Flow rate is maximized with respect to local slip ratio and static pressure for known stagnation conditions. Graphs are presented giving maximum steam/water flow rates for: local static pressures between 25 and 3,000 psia, with local qualities from 0.01 to 1.00; local stagnation pressures and enthalpies which cover the range of saturation states.


Author(s):  
Mohammad J. Izadi ◽  
Alireza Falahat

In this investigation an attempt is made to find the best hub to tip ratio, the maximum number of blades, and the best angle of attack of an axial fan with flat blades at a fixed rotational speed for a maximum mass flow rate in a steady and turbulent conditions. In this study the blade angles are varied from 30 to 70 degrees, the hub to tip ratio is varied from 0.2 to 0.4 and the number of blades are varied from 2 to 6 at a fixed hub rotational speed. The results show that, the maximum flow rate is achieved at a blade angle of attack of about 45 degrees for when the number of blades is set equal to 4 at most rotational velocities. The numerical results show that as the hub to tip ratio is decreased, the mass flow rate is increased. For a hub to tip ratio of 0.2, and an angle of attack around 45 degrees with 4 blades, a maximum mass flow rate is achieved.


Author(s):  
Jaikumar Sankar ◽  
Liu Yang

Abstract This work focuses on investigating the time of sinking of a Saxon bowl proposed by ‘International Young Physicists’ Tournament in 2020. A quasi-static model is built to simulate the motion path of the bowl and predict the sinking time subsequently. The model assumes an open axisymmetric bowl with a hole in its base. The hole is modelled as a pipe for which the flow profile is governed by a modified Bernoulli’s equation which has a Coefficient of Discharge (C_d) added to account for energy losses. The motion of the entire bowl is assumed to be in quasi-static equilibrium for an infinitesimal time interval to calculate the volumetric flow rate through the hole. The model is used to predict the sinking times of various bowls against independent variables - hole radius, bowl dimensions, mass of bowl, mass distribution of bowl, and Coefficient of Discharge - and predict the motion path of bowls of different, axisymmetric geometries. Characterisation of C_d was done by draining a bowl filled with water and measuring the time taken to do so. Experimental verification was completed through measuring sinking times of 3D printed hemispherical bowls of the different variables in water. Motion tracking of bowls with different geometries was done using computational pixel tracking software to verify the model’s predictive power. Data from experiments for sinking time against the variables corroborate with the model to a great degree. The motion path tracked, matched the modelled motion path to a high degree for bowls of different shapes, namely a hemisphere, cylinder, frustum, and a free-form axisymmetric shape. The work is poised for an undergraduate level of readership.


Author(s):  
Yi Hou ◽  
Lipeng He ◽  
Zheng Zhang ◽  
Baojun Yu ◽  
Hong Jiang ◽  
...  

This paper focuses on a new structure in the valveless piezoelectric pump, which has a combination structure of the conical flow channel and two fishtail-shaped bluffbodies in the chamber of the pump. The fishtail-shaped bluffbody is inspired by the shape of the swimming fish to diminish the backflow and optimize the performance of the pump. The performance is studied by changing the shape and size of the inlet and outlet, the bluff bodies’ height and the space between two bluff bodies. The results show that the 3 mm × 3 mm square inlet, 3 mm diameter round outlet, 3 mm height of bluffbodies, 6.8 mm pitch of bluffbodies has a best performance in all 10 prototypes, which implements a maximum flow rate of 87.5 ml/min at 170 V 40 Hz with a noise of 42.6 dB. This study makes a preliminary investigation and theoretical explanation for the subsequent optimization of this structure, improved the performance of the valveless piezoelectric pump, broaden the thinking of the design for the bluffbody for better performance of the valveless piezoelectric pump.


Sign in / Sign up

Export Citation Format

Share Document