scholarly journals Dynamic Characteristics of Accelerator-Driven Subcritical Reactor With Self-Adapting Multi-Mode Core Few-Group Constants

2021 ◽  
Vol 8 ◽  
Author(s):  
Nianbiao Deng ◽  
Jinsen Xie ◽  
Cheng Hou ◽  
Wenjie Zeng ◽  
Zhenping Chen ◽  
...  

In this study, the dynamic characteristics of accelerator-driven subcritical reactor (ADSR) under beam transients with high heterogeneity of neutron flux in time-space are investigated. Multi-mode core few-group constants are generated by three kinds of neutron fluxes: steady state of ADSR, λ-eigenvalue fundamental wave, and α-eigenvalue fundamental wave. The proposed few-group constants overcome the limitation of single few-group constant generated by two-step method that cannot consider the variation in neutron flux density and neutron energy spectrum with time and space. Compared to the existing few-group constants generated by two-step method under different operating conditions, the self-adapting multi-mode core few-group constants exhibit higher accuracy in the case of following two modes: steady-state mode of ADSR in the starting process and λ-eigenvalue mode in the beam trip condition. Overall, this research provides useful insights on neutron kinetics and can boost the development of ADSRs.

1992 ◽  
Vol 26 (5-6) ◽  
pp. 1355-1363 ◽  
Author(s):  
C-W. Kim ◽  
H. Spanjers ◽  
A. Klapwijk

An on-line respiration meter is presented to monitor three types of respiration rates of activated sludge and to calculate effluent and influent short term biochemical oxygen demand (BODst) in the continuous activated sludge process. This work is to verify if the calculated BODst is reliable and the assumptions made in the course of developing the proposed procedure were acceptable. A mathematical model and a dynamic simulation program are written for an activated sludge model plant along with the respiration meter based on mass balances of BODst and DO. The simulation results show that the three types of respiration rate reach steady state within 15 minutes under reasonable operating conditions. As long as the respiration rate reaches steady state the proposed procedure calculates the respiration rate that is equal to the simulated. Under constant and dynamic BODst loading, the proposed procedure is capable of calculating the effluent and influent BODst with reasonable accuracy.


Author(s):  
Bassam A. Hemade ◽  
Hamed A. Ibrahim ◽  
Hossam E.A. Talaat

Background: The security assessment plays a crucial role in the operation of the modern interconnected power system network. Methods: Hence, this paper addresses the application of k-means clustering algorithm equipped with Principal Component Analysis (PCA) and silhouette analysis for the classification of system security states. The proposed technique works on three principal axes; the first stage involves contingency quantification based on developed insecurity indices, the second stage includes dataset preparation to enhance the overall performance of the proposed method using PCA and silhouette analysis, and finally the application of the clustering algorithm over data. Results: The proposed composite insecurity index uses available synchronized measurements from Phasor Measurement Units (PMUs) to assess the development of cascading outages. Considering different operational scenarios and multiple levels of contingencies (up to N-3), Fast Decoupled Power Flow (FDPF) have been used for contingency replications. The developed technique applied to IEEE 14-bus and 57-bus standard test system for steady-state security evaluation. Conclusion: The obtained results ensure the robustness and effectiveness of the established procedure in the assessment of the system security irrespective of the network size or operating conditions.


1986 ◽  
Vol 51 (11) ◽  
pp. 2481-2488
Author(s):  
Benitto Mayrhofer ◽  
Jana Mayrhoferová ◽  
Lubomír Neužil ◽  
Jaroslav Nývlt

The paper presents a simple model of recrystallization with countercurrent flows of the solution and the crystals being purified. The model assumes steady-state operating conditions, an equilibrium between the outlet streams of each stage, and the same equilibrium temperature and distribution coefficient for all stages. With these assumptions, the model provides the basis for analyzing the variation in the degree of purity as a function of the number of recrystallization stages. The analysis is facilitated by the use of a diagram constructed for the limiting case of perfect removal of the mother liquor from the crystals between the stages.


Author(s):  
Ioannis Vlaskos ◽  
Ennio Codan ◽  
Nikolaos Alexandrakis ◽  
George Papalambrou ◽  
Marios Ioannou ◽  
...  

The paper describes the design process for a controlled pulse turbocharging system (CPT) on a 5 cylinder 4-stroke marine engine and highlights the potential for improved engine performance as well as reduced smoke emissions under steady state and transient operating conditions, as offered by the following technologies: • controlled pulse turbocharging, • high pressure air injection onto the compressor impeller as well as into the air receiver, and • an electronic engine control system, including a hydraulic powered electric actuator. Calibrated engine simulation computer models based on the results of tests performed on the engine in its baseline configuration were used to design the CPT components. Various engine tests with CPT under steady state and transient operating conditions show the engine optimization process and how the above-mentioned technologies benefit engine behavior in both generator and propeller law operation.


Author(s):  
Bin Wang ◽  
Haocen Zhao ◽  
Ling Yu ◽  
Zhifeng Ye

It is usual that fuel system of an aero-engine operates within a wide range of temperatures. As a result, this can have effect on both the characteristics and precision of fuel metering unit (FMU), even on the performance and safety of the whole engine. This paper provides theoretical analysis of the effect that fluctuation of fuel temperature has on the controllability of FMU and clarifies the drawbacks of the pure mathematical models considering fuel temperature variation for FMU. Taking the electrohydraulic servovalve-controlled FMU as the numerical study, simulation in AMESim is carried out by thermal hydraulic model under the temperatures ranged from −10 to 60 °C to confirm the effectiveness and precision of the model on the basis of steady-state and dynamic characteristics of FMU. Meanwhile, the FMU testing workbench with temperature adjustment device employing the fuel cooler and heater is established to conduct an experiment of the fuel temperature characteristics. Results show that the experiment matches well with the simulation with a relative error no more than 5% and that 0–50 °C fuel temperature variation produces up to 5.2% decrease in fuel rate. In addition, step response increases with the fuel temperature. Fuel temperature has no virtual impact on the steady-state and dynamic characteristics of FMU under the testing condition in this paper, implying that FMU can operate normally in the given temperature range.


2021 ◽  
Vol ahead-of-print (ahead-of-print) ◽  
Author(s):  
Masoud Behzad ◽  
Benjamin Herrmann ◽  
Williams R. Calderón-Muñoz ◽  
José M. Cardemil ◽  
Rodrigo Barraza

Purpose Volumetric air receivers experience high thermal stress as a consequence of the intense radiation flux they are exposed to when used for heat and/or power generation. This study aims to propose a proper design that is required for the absorber and its holder to ensure efficient heat transfer between the fluid and solid phases and to avoid system failure due to thermal stress. Design/methodology/approach The design and modeling processes are applied to both the absorber and its holder. A multi-channel explicit geometry design and a discrete model is applied to the absorber to investigate the conjugate heat transfer and thermo-mechanical stress levels present in the steady-state condition. The discrete model is used to calibrate the initial state of the continuum model that is then used to investigate the transient operating states representing cloud-passing events. Findings The steady-state results constitute promising findings for operating the system at the desired airflow temperature of 700°C. In addition, we identified regions with high temperatures and high-stress values. Furthermore, the transient state model is capable of capturing the heat transfer and fluid dynamics phenomena, allowing the boundaries to be checked under normal operating conditions. Originality/value Thermal stress analysis of the absorber and the steady/transient-state thermal analysis of the absorber/holder were conducted. Steady-state heat transfer in the explicit model was used to calibrate the initial steady-state of the continuum model.


Sign in / Sign up

Export Citation Format

Share Document