scholarly journals Clinical and Ultrasound Biomicroscopic Characteristics of Congenital Fibrovascular Pupillary Membrane-Induced Secondary Glaucoma

2021 ◽  
Vol 8 ◽  
Author(s):  
Yingting Zhu ◽  
Lei Fang ◽  
Yimin Zhong ◽  
Julius Oatts ◽  
Ying Han ◽  
...  

Purpose: The purpose of this study was to describe and summarize the clinical features of congenital fibrovascular pupillary membrane-induced secondary glaucoma (CFPMSG).Design: Cross-sectional case series.Methods: Eyes of 32 patients with CFPMSG were enrolled. Demographic data, including gender, laterality, age at presentation, and age at onset of glaucoma were collected. Patients underwent comprehensive ophthalmic examinations and ultrasound biomicroscopy (UBM). CFPMSG eyes were classified into three groups based on UBM findings and intergroup analysis was performed using ANOVA.Results: The average age at presentation was 2.4 ± 4.6 months (mean ± SD) and at glaucoma onset was 3.8 ± 4.5 months. Compared to normal fellow eyes, all affected eyes had increased intraocular pressure (IOP), axial length, corneal diameter, and central corneal thickness, and decreased anterior chamber depth (ACD) (all P ≤ 0.001). Twenty-two affected eyes (68.8%) had evidence of glaucomatous optic neuropathy. Based on iris configuration on UBM, eyes were classified as 53% type I (“U” shape), 34% type II (“Y” shape), and 13% type III (no anterior chamber). IOP in types II (33.8 ± 5.9 mmHg) and III (35.2 ± 5.9 mmHg) was significantly higher than in type I eyes (26.5 ± 5.1 mmHg). The ACD was shallower in type II compared to type I (P = 0.045).Conclusion: Congenital fibrovascular pupillary membrane-induced secondary glaucoma is characterized by ocular hypertension, corneal enlargement and edema, axial length elongation, and glaucomatous optic neuropathy. Glaucoma in this condition is secondary to pupillary block and angle-closure. UBM provides important information for the diagnosis and classification of CFPMSG. This novel classification system demonstrated varying levels of severity and may guide on management of this disease.

2021 ◽  
Author(s):  
Qiong Lei ◽  
Haixia Tu ◽  
Xi Feng ◽  
Yong Wang

Abstract Background: To create an anterior chamber depth (ACD) regression model for adult cataract surgery candidates from China, and to evaluate the distribution of their ocular biometric parameters.Methods: The ocular biometric records of 28,709 right eyes of cataract surgery candidates who were treated at Aier Eye Hospitals in nine cities from 2018 to 2019 were retrospectively analyzed. All measurements were taken with IOLMaster 700. We included patients who were at least 40 years old and were diagnosed with cataract.Results: The mean age of the patients was 68.6 ± 11.0 years. The mean values recorded were as follows: axial length (AL), 24.17 ± 2.47 mm; mean keratometry (Km) value, 44.09 ± 3.25 D; corneal astigmatism (CA), 1.06 ± 0.98 D; ACD, 3.02 ± 0.45 mm; lens thickness (LT), 4.52 ± 0.45 mm; central corneal thickness (CCT), 0.534 ± 0.04 mm; and white to white (WTW) corneal diameter, 11.64 ± 0.46 mm. The proportion of patients with long axial length (AL >25 mm) decreased with age. ACD, LT, AL, Km, WTW, and age were correlated. In the multivariate regression analysis of ACD, which included LT, AL, WTW, sex, Km, CCT, and age, there was a reasonable prediction with adjusted R2 = 0.629.Conclusions: The results show that high myopes are inclined to schedule cataract surgery at a younger age. LT and AL were found to be important factors that affect ACD. This study provides reference data for cataract patients from China.


2016 ◽  
Vol 2016 ◽  
pp. 1-4 ◽  
Author(s):  
Ercan Ozsoy ◽  
Abuzer Gunduz ◽  
Ersin Ersan Demirel ◽  
Tongabay Cumurcu

Purpose. To evaluate anterior segment’s structures by Pentacam in patients with tilted disc syndrome (TDS).Methods. Group 1 included forty-six eyes of forty-six patients who have the TDS. Group 2 including forty-six eyes of forty-six cases was the control group which was equal to the study group in age, gender, and refraction. A complete ophthalmic examination was performed in both groups. All cases were evaluated by Pentacam. The axial length (AL) of eyes was measured by ultrasound. Quantitative data obtained from these measurements were compared between two groups.Results. There was no statistically significant difference for age, gender, axial length, and spherical equivalent measurements between two groups (p=0.625,p=0.830,p=0.234, andp=0.850). There was a statistically significant difference for central corneal thickness (CCT), corneal volume (CV), anterior chamber angle (ACA), and pupil size measurements between two groups (p=0.001,p=0.0001,p=0.003, andp=0.001). Also, there was no statistically significant difference for anterior chamber depth (ACD), anterior chamber volume (ACV), and lens thickness (LT) measurements between two groups (p=0.130,p=0.910, andp=0.057).Conclusion. We determined that CCT was thinner, CV was less, and ACA was narrower in patients with TDS. There are some changes in the anterior segment of the eyes with tilted disc.


2016 ◽  
Vol 27 (4) ◽  
pp. 417-422 ◽  
Author(s):  
José Ignacio Fernández-Vigo ◽  
Lucía De-Pablo-Gómez-De-Liaño ◽  
Cristina Fernández-Vigo ◽  
Inés Sánchez-Guillén ◽  
Enrique Santos-Bueso ◽  
...  

Purpose To determine the prevalence of trabecular-iris contact (TIC) and quantify this contact in healthy Caucasian individuals using Fourier-domain optical coherence tomography (FD-OCT). Methods For this cross-sectional study, 2,012 eyes of 1,006 healthy subjects were recruited among individuals undergoing a routine ophthalmologic checkup. In each participant, age, sex, intraocular pressure, and spherical refractive error were first recorded along with anterior chamber depth and volume, central corneal thickness measured with the Pentacam, and axial length with the IOLMaster. Anterior chamber angle variables and the presence of TIC in the horizontal quadrants were determined by anterior segment FD-OCT (RTVue 100®). When TIC was observed, TIC length (TICL) and its percentage in relation to the length of the trabecular meshwork (TICL percentage) were also measured. Results Trabecular-iris contact in the horizontal quadrants was observed in 34 eyes of 25 patients, representing 1.6% of the total number of eyes examined. In this subgroup of individuals, mean age was 55.8 years, 84% were women, and spherical refractive error ranged from -0.25 to 8.25 D. Eyes with TIC showed an angle width of less than 23.2 degrees and axial length shorter than 23.7 mm. Mean TICL was 239 ± 79 μm (103-495 μm) and mean TICL percentage was 46.9% ± 13.9% (17.2%-76.3%). Conclusions The prevalence of TIC was low in this population. Fourier-domain optical coherence tomography emerged as useful to assess its prevalence and quantify the extent of TIC.


2020 ◽  
pp. 112067212091453
Author(s):  
Ali Keleş ◽  
Emine Şen ◽  
Ufuk Elgin

Purpose: The aims of this study were to compare the biometric parameters and axial lengths of eyes with phacomorphic glaucoma and mature cataract and to identify differences that might predispose to development of phacomorphic glaucoma. Methods: Three hundred forty-two patients were enrolled in this retrospective study. The eyes were divided into four groups—Group (G)1: phacomorphic glaucoma ( n = 29), G2: mature cataract ( n = 313), G3: contralateral phacomorphic glaucoma ( n = 29), and G4: contralateral mature cataract ( n = 313). Central corneal thickness and anterior chamber depth were assessed by optical low-coherence reflectometry (Lenstar LS 900®; Haag-Streit AG, Switzerland), while axial length was determined by A-scan ultrasound biometry. Results: The mean central corneal thickness of G1 was significantly higher than in other groups ( p < 0.001) and the mean anterior chamber depth of G1 was the lowest among the groups ( p < 0.001). Also, G2 had lower mean anterior chamber depth than G4 ( p < 0.001) and G3 had lower mean anterior chamber depth than G4 ( p = 0.007). Anterior chamber depth less than 3.27 mm had the higher odds ratio for distinguishing G3 versus G4 (odds ratio = 10.79, p < 0.001). Furthermore, patients aged ⩾68.9 years had the higher odds ratio for distinguishing G1 versus G2 (odds ratio = 2.82, p = 0.019). There was no significant difference in the presence of pseudoexfoliation material between G1 and G2 ( p = 0.057). There were no significant differences in axial length values among the four groups ( p = 0.097). Conclusion: Advanced age and shallow anterior chamber depth were found to be risk factors for developing phacomorphic glaucoma, but the presence of pseudoexfoliation material was not found to play a role as a risk factor in phacomorphic glaucoma development.


2021 ◽  
Author(s):  
Yanzhen Xue ◽  
Yonghong Guo ◽  
Ruibo Zhao

Abstract Purpose: To determine patient preoperative anatomical features and the parameters of implantable collamer lenses (ICLs) relevant in explaining vault variability.Setting: Ophthalmology Xi’an Aier Gucheng Eye hospital , Xi’an China.Design: Retrospective case series.Methods:This study comprised 88 eyes of 45 patients implanted with myopic or toric ICLs between May 2021 and August 2021.Pentacam imaging was used for assessing white-to-white (WTW) diameter, central keratometry, anterior chamber depth(ACD), central corneal thickness and vault. Anterior-segment optical coherence tomography(AS-OCT) was used to measure the horizontal anterior chamber angle distance (ATA). Ultrasound biomicroscopy (UBM) was used to measure horizontal and vertical sulcus to sulcus(vSTS). According to different ACD,we divide ACD into shallow group(2.8 to 3.2 mm),medium group(3.2 to 3.5 mm),and deep group(>3.5mm).Results: Linear regression analysis found significant correlation between WTW diameters and ATA diameters( y= 0.9605x+0.1491,R² = 0.9148),with a coefficient of determinant of 0.9148 (P<0.01). Linear regression analysis found significant correlation between hSTS and vSTS(y=0.9855x-0.0178,R²=0.1979),with a coefficient of determinant of 0.1979 (P<0.01). WTW diameters showed statistically significant difference in shallow and medium ACD (t=-3.28,P<0.01 ), significant difference in shallow and deep ACD (t=-4.69,P<0.01 ),there was no correlation in medium and deep ACD(t=-1.41,P>0.05 ). There was a statistically significant correlation between WTW diameters and hSTS diameters when the ACD was less than 3.5 mm (t=-0.451, P=0.000) (t=1.406, P=0.026),but weak correlation when the ACD was bigger than 3.5 mm(t=1.594, P=0.051). ATA and WTW with a mean difference close to zero(-0.66 mm). Despite the relatively high correlation (intraclass correlation co-efficient =0.689), the range of agreement is quite broad (1.33 mm).Conclusions:ATA measured with AS-OCT can not be used interchangeably with WTW obtained with Pentacam. WTW diameters and hSTS diameters have a statistically significant correlation when the ACD was less than 3.5 mm. WTW, ATA, hSTS and vSTS all should be considered during design the size of lens and regulating the vault after surgery.


2021 ◽  
Vol 37 (3) ◽  
Author(s):  
Muhammad Suhail Sarwar ◽  
Sehrish Shahid ◽  
Muhammad Arslan Ashraf ◽  
Shaista Kanwal

Purpose:  To check inter observer reproducibility of axial ocular measurements i.e. central corneal thickness (CCT), anterior chamber depth (ACD), aqueous depth (AD), lens thickness (LT), anterior segment lens (ASL), vitreous length (VL) and axial length (AL) with non-contact HAAG-STRAIT biometer. Study Design:  Comparative Reproducibility Analysis. Place and Duration of Study:  College of ophthalmology and allied vision sciences (COAVS), Mayo Hospital, Lahore. Methods:  This study included 66 healthy students (132 eyes). Data was collected through self-designed proforma by 2 operators independently. SPSS 21 was used for data analysis. Interclass correlation was applied for agreement between the two readings. Interclass coefficient (ICC) value greater than 0.7 was considered as excellent correlation. Results:  The mean CCT, AD, ACD, LT, ASL, VL, and AL were 526.47 ± 35.72 µm and 526.47 ± 36.06 µm (ICC = 0.92); 2.93 ± 0.29 mm and 2.93 ± 0.29 mm (ICC = 0.81); 3.45 ± 0.30 mm and 3.46 ± 0.30 mm (ICC = 0.79); 3.58 ± 0.28 mm and 3.56 ± 0.22 mm (ICC = 0.76); 7.03 ± 0.30 mm and 7.02 ± 0.27 mm (ICC = 0.80); 16.56 ± 0.85 mm and 16.62 ± 0.81 mm (ICC = 0.72); and 23.59 ± 0.85 mm and 23.64 ± 0.87 mm (ICC: 0.76) of observer 1 and 2, respectively. Conclusion:  Non-contact Biometer (HAAG-STRAIT) has high inter-observer reproducibility with strong interclass coefficient of greater than 0.72. Key Words:  Biometry, Axial Length, Central Corneal Thickness, Anterior Chamber Depth.


Sign in / Sign up

Export Citation Format

Share Document