scholarly journals Proxy Measures and Novel Strategies for Estimating Nitrogen Utilisation Efficiency in Dairy Cattle

Animals ◽  
2021 ◽  
Vol 11 (2) ◽  
pp. 343
Author(s):  
Anna Lavery ◽  
Conrad Ferris

The efficiency with which dairy cows convert dietary nitrogen (N) to milk N is generally low (typically 25%). As a result, much of the N consumed is excreted in manure, from which N can be lost to the environment. Therefore there is increasing pressure to reduce N excretion and improve N use efficiency (NUE) on dairy farms. However, assessing N excretion and NUE on farms is difficult, thus the need to develop proximate measures that can provide accurate estimates of nitrogen utilisation. This review examines a number of these proximate measures. While a strong relationship exists between blood urea N and urinary N excretion, blood sampling is an invasive technique unsuitable for regular herd monitoring. Milk urea N (MUN) can be measured non-invasively, and while strong relationships exist between dietary crude protein and MUN, and MUN and urinary N excretion, the technique has limitations. Direct prediction of NUE using mid-infrared analysis of milk has real potential, while techniques such as near-infrared spectroscopy analysis of faeces and manure have received little attention. Similarly, techniques such as nitrogen isotope analysis, nuclear magnetic resonance spectroscopy of urine, and breath ammonia analysis may all offer potential in the future, but much research is still required.

2018 ◽  
Vol 39 (10) ◽  
pp. 2035-2047 ◽  
Author(s):  
Gemma Bale ◽  
Subhabrata Mitra ◽  
Isabel de Roever ◽  
Magdalena Sokolska ◽  
David Price ◽  
...  

There is a need for a method of real-time assessment of brain metabolism during neonatal hypoxic-ischaemic encephalopathy (HIE). We have used broadband near-infrared spectroscopy (NIRS) to monitor cerebral oxygenation and metabolic changes in 50 neonates with HIE undergoing therapeutic hypothermia treatment. In 24 neonates, 54 episodes of spontaneous decreases in peripheral oxygen saturation (desaturations) were recorded between 6 and 81 h after birth. We observed differences in the cerebral metabolic responses to these episodes that were related to the predicted outcome of the injury, as determined by subsequent magnetic resonance spectroscopy derived lactate/N-acetyl-aspartate. We demonstrated that a strong relationship between cerebral metabolism (broadband NIRS-measured cytochrome-c-oxidase (CCO)) and cerebral oxygenation was associated with unfavourable outcome; this is likely to be due to a lower cerebral metabolic rate and mitochondrial dysfunction in severe encephalopathy. Specifically, a decrease in the brain tissue oxidation state of CCO greater than 0.06 µM per 1 µM brain haemoglobin oxygenation drop was able to predict the outcome with 64% sensitivity and 79% specificity (receiver operating characteristic area under the curve = 0.73). With further work on the implementation of this methodology, broadband NIRS has the potential to provide an early, cotside, non-invasive, clinically relevant metabolic marker of perinatal hypoxic-ischaemic injury.


NIR news ◽  
2008 ◽  
Vol 19 (1) ◽  
pp. 4-7 ◽  
Author(s):  
Erik Tønning ◽  
Lars Nørgaard ◽  
Søren B. Engelsen ◽  
Lene Pedersen ◽  
Kim H. Esbensen

Oikos ◽  
2021 ◽  
Author(s):  
Philip M. Riekenberg ◽  
Tijs Joling ◽  
Lonneke L. IJsseldijk ◽  
Andreas M. Waser ◽  
Marcel T. J. van der Meer ◽  
...  

PLoS ONE ◽  
2018 ◽  
Vol 13 (10) ◽  
pp. e0205448 ◽  
Author(s):  
Zaid Alhabbar ◽  
Rongchang Yang ◽  
Angela Juhasz ◽  
Hu Xin ◽  
Maoyun She ◽  
...  

Proceedings ◽  
2019 ◽  
Vol 27 (1) ◽  
pp. 8 ◽  
Author(s):  
David Perpetuini ◽  
Antonio Maria Chiarelli ◽  
Vincenzo Vinciguerra ◽  
Piergiusto Vitulli ◽  
Sergio Rinella ◽  
...  

Photoplethysmography (PPG) is a non-invasive technique that employs near infrared light to estimate periodic oscillations in blood volume within arteries caused by the pulse pressure wave. Importantly, combined Electrocardiography (ECG) and PPG can be employed to quantify arterial stiffness. The capabilities of a home-made multi-channel PPG-ECG device (7 PPG probes, 4 ECG derivations) to evaluate arterial ageing were assessed. The high numerosity of channels allowed to estimate arterial stiffness at multiple body locations, without supra-systolic cuff occlusion, providing a fast and accurate examination of cardiovascular status and potentially allowing large scale clinical screening of cardiovascular risk.


Sign in / Sign up

Export Citation Format

Share Document