scholarly journals Conjugate Heat Transfer Analysis of PCM Suspensions in a Circular Tube under External Cooling Convection: Wall Conduction Effects

2020 ◽  
Vol 10 (6) ◽  
pp. 2034 ◽  
Author(s):  
C. J. Ho ◽  
Z.C. Wang ◽  
R.H. Chen ◽  
Chi-Ming Lai

In this paper, a numerical method is used to investigate the conjugate heat transfer of a phase change material (PCM) suspension in a circular tube under external cooling convection. The following parameters and ranges were considered: dimensionless tube wall thickness, t w (0–0.5); wall-to-fluid thermal conductivity ratio, k w f * (0.1–10); volumetric fraction of PCM particles, c v (0.1); Biot number, B i o (1); Stefan number, Ste (0.1); and Peclet number, Pe (1000). The results show that the wall thermal conductivity considerably affects the outer/inner wall temperature of the tube, the average temperature of the working fluid, and the volumetric liquid fraction of PCM particles. Thus, wall conduction effects must be properly accounted for to model heat transfer in a PCM suspension in tube flow.

Author(s):  
Carol E. Bryant ◽  
James L. Rutledge

Abstract Ceramic matrix composites (CMCs) show promise as higher temperature capable alternatives to traditional metallic components in gas turbine engine hot gas paths. However, CMC components will still require both internal and external cooling, such as film cooling. The overall cooling effectiveness is determined not only by the design of coolant flow, but also by the conduction through the materiel itself. CMCs have anisotropic thermal conductivity, giving rise to heat flow that differs somewhat relative to what we have come to expect from experience with traditional metallic components. Conjugate heat transfer computational fluid dynamics (CFD) simulations were performed in order to isolate the effect anisotropic thermal conductivity has on a cooling architecture consisting of both internal and external cooling. Results show the specific locations and unique effects of anisotropic thermal conduction on overall effectiveness. Thermal conductivity anisotropy is shown to have a significant effect on the resulting overall effectiveness. As CMCs begin to make their way into gas turbine engines, care must be taken to ensure that anisotropy is characterized properly and considered in the thermal analysis.


Author(s):  
Yasin Varol ◽  
Hakan F. Oztop ◽  
Ioan Pop

PurposeThe purpose of this paper is to study the conjugate heat transfer via natural convection and conduction in a triangular enclosure filled with a porous medium.Design/methodology/approachDarcy flow model was used to write governing equations with Boussinesq approximation. The transformed governing equations are solved numerically using a finite difference technique. It is assumed that the enclosure consists of a conducting bottom wall of finite thickness, an adiabatic (insulated) vertical wall and a cooled inclined wall.FindingsFlow patterns, temperature and heat transfer were presented at different dimensionless thickness of the bottom wall, h, from 0.05 to 0.3, different thermal conductivity ratio between solid material and fluid, k, from 0.44 to 283 and Rayleigh numbers, Ra, from 100 to 1000. It is found that both thermal conductivity ratio and thickness of the bottom wall can be used as control parameters for heat transport and flow field.Originality/valueIt is believed that this is the first paper on conduction‐natural convection in porous media filled triangular enclosures with thick wall. In the last years, most of the researchers focused on regular geometries such as rectangular or square cavity bounded by thick wall.


Mechanika ◽  
2020 ◽  
Vol 26 (2) ◽  
pp. 126-133
Author(s):  
Thansekhar M.Rathinam

A numerical study of conjugate free convection heat transfer of Al2O3/water nanofluid inside a differentially heated square enclosure with a baffle attached to its hot wall has been carried out. A detailed parametric study has been carried out to analyze the effect of Rayleigh number (104 < Ra < 106), length, thickness and position of baffle, conductivity ratio and volume fraction of the nanoparticle (0<<0.2) on heat transfer. The thermal conductivity ratio of the baffle plays a major role on the conjugate heat transfer inside the enclosure. Higher the baffle length better is the effectiveness of the baffle. The average Nusselt number is found to be an increasing function of both thermal conductivity ratio and volume fraction of the nanofluid. The minimum enhancement of conjugate heat transfer is 30% when Al2O3/water nanofluid of 0.1 volume fraction is used for the entire range of Rayleigh number considered.


Author(s):  
Ahmed Kadhim Hussein ◽  
Muhaiman Alawi Mahdi ◽  
Obai Younis

In this research, the entropy production of the conjugate heat transfer in a tilted porous cavity in respect to heat source and solid walls locations has been studied numerically. Three different cases of the cavity with finite walls thickness and heat source locations are considered in the present study. For both cases one and two, the cavity considered has a vertical finite walls thickness, while the cavity with the horizontal finite walls thickness is considered for case three. For cases one and two, the left sidewall of the cavity is exposed to heat source, whereas the rest of this wall as well as the right sidewall are adiabatic. The upper and lower cavity walls are adiabatic. For case three, the lower wall is exposed to a localized heat source, while the rest of it is assumed adiabatic. The upper wall is cold, whereas the left and right sidewalls are adiabatic. The flow and thermal fields properties along with the entropy production are computed for the modified Rayleigh number (150 ? Ram ? 1000), thermal conductivity ratio (1 ? Kr ? 10), heat source length (0.2 ? B ? 0.6), aspect ratio (0.5 ? AR ? 2) and walls thickness (0.1 ? D1 ? 0.2 and 0.1 ? D2 ? 0.2) respectively. The results show that, the maximum values of the entropy generated from fluid friction develop close to the cavity wall-fluid interfacial, while the maximum values of the entropy generated from heat transfer develop nearby the heat source region. The average Bejan number (Beav) is higher than (0.5) for cases one and two. While for case three, it was found to be less than (0.5). Also, the results show that as the modified Rayleigh number, thermal conductivity ratio, heat source length and aspect ratio increased, the fluid flow intensity in the cavity increased. While, it decreased when the walls thickness increased. From the results, it is concluded that case three gives a higher heat transfer enhancement. The obtained results are compared against another published results and a good agreement is found between them.


Micromachines ◽  
2020 ◽  
Vol 11 (2) ◽  
pp. 218 ◽  
Author(s):  
Danish Rehman ◽  
Jojomon Joseph ◽  
Gian Luca Morini ◽  
Michel Delanaye ◽  
Juergen Brandner

In micro heat exchangers, due to the presence of distributing and collecting manifolds as well as hundreds of parallel microchannels, a complete conjugate heat transfer analysis requires a large amount of computational power. Therefore in this study, a novel methodology is developed to model the microchannels as a porous medium where a compressible gas is used as a working fluid. With the help of such a reduced model, a detailed flow analysis through individual microchannels can be avoided by studying the device as a whole at a considerably less computational cost. A micro heat exchanger with 133 parallel microchannels (average hydraulic diameter of 200 μ m) in both cocurrent and counterflow configurations is investigated in the current study. Hot and cold streams are separated by a stainless-steel partition foil having a thickness of 100 μ m. Microchannels have a rectangular cross section of 200 μ m × 200 μ m with a wall thickness of 100 μ m in between. As a first step, a numerical study for conjugate heat transfer analysis of microchannels only, without distributing and collecting manifolds is performed. Mass flow inside hot and cold fluid domains is increased such that inlet Reynolds number for both domains remains within the laminar regime. Inertial and viscous coefficients extracted from this study are then utilized to model pressure and temperature trends within the porous medium model. To cater for the density dependence of inertial and viscous coefficients due to the compressible nature of gas flow in microchannels, a modified formulation of Darcy–Forschheimer law is adopted. A complete model of a double layer micro heat exchanger with collecting and distributing manifolds where microchannels are modeled as the porous medium is finally developed and used to estimate the overall heat exchanger effectiveness of the investigated micro heat exchanger. A comparison of computational results using proposed hybrid methodology with previously published experimental results of the same micro heat exchanger showed that adopted methodology can predict the heat exchanger effectiveness within the experimental uncertainty for both cocurrent and counterflow configurations.


Author(s):  
M. McGarry ◽  
C. Bonilla ◽  
I. Metzger

A validated computational model was created to simulate the heat transfer from a heated surface using liquid metals and alloys during conjugate heat transfer. This model explores the effect of the Rayleigh number, Prandtl number, thermal conductivity ratio, and aspect ratio on the Nusselt number along the hot surface. The data will show how to keep the temperature sensitive components along the hot wall cool by maximizing the amount of heat removed from the hot wall. The data show three distinct regions that occur as a function of the Rayleigh number for a fixed k∗ and d∗. The data also show that the thermal conductivity ratio between the fluid and the solid conducting block has little effect on the Nusselt number at a fixed Rayleigh number. However, when examining the effect of the aspect ratio on the Nusselt number, two distinct regions can be seen. The results demonstrate that in order to keep the temperature sensitive components cool along the hot wall, one would want to have large Rayleigh and Prandtl numbers. The easiest way to achieve large Rayleigh numbers is by increasing the height of the enclosure. Large Prandtl numbers can be achieved by choosing a fluid that is highly conductive. In addition, the choice of material for the center solid conducting block does not impact the amount of heat removed from the hot wall. However, increased cooling can be achieved by decreasing the spacing between the hot and the cold wall.


Energies ◽  
2021 ◽  
Vol 14 (3) ◽  
pp. 572
Author(s):  
Ching-Jenq Ho ◽  
Shih-Ming Lin ◽  
Chi-Ming Lai

This study explores the effects of pipe wall properties (thermal conductivity k and wall thickness tw) on the heat transfer performance of a rectangular thermosyphon with a phase change material (PCM) suspension and a geometric configuration (aspect ratio = 1; dimensionless heating section length = 0.8; dimensionless relative elevation between the cooling and the heating sections = 2) that ensures the optimum heat transfer efficiency in the cooling section. The following parameter ranges are studied: the dimensionless loop wall thickness (0 to 0.5), wall-to-fluid thermal conductivity ratio (0.1 to 100), modified Rayleigh number (1010 to 1011), and volumetric fraction of PCM particles (0 to 10%). The results show that appropriate selection of k and tw can lead to improved heat transfer effectiveness in the cooling section of the PCM suspension-containing rectangular thermosyphon.


Energies ◽  
2021 ◽  
Vol 14 (8) ◽  
pp. 2096
Author(s):  
Joon Ahn ◽  
Jeong Chul Song ◽  
Joon Sik Lee

Large eddy simulations are performed to analyze the conjugate heat transfer of turbulent flow in a ribbed channel with a heat-conducting solid wall. An immersed boundary method (IBM) is used to determine the effect of heat transfer in the solid region on that in the fluid region in a unitary computational domain. To satisfy the continuity of the heat flux at the solid–fluid interface, effective conductivity is introduced. By applying the IBM, it is possible to fully couple the convection on the fluid side and the conduction inside the solid and use a dynamic subgrid scale model in a Cartesian grid. The blockage ratio (e/H) is set at 0.1, which is typical for gas turbine blades. Through conjugate heat transfer analysis, it is confirmed that the heat transfer peak in front of the rib occurs because of the impinging of the reattached flow and not the influence of the thermal boundary condition. When the rib turbulator acts as a fin, its efficiency and effectiveness are predicted to be 98.9% and 8.32, respectively. When considering conjugate heat transfer, the total heat transfer rate is reduced by 3% compared with that of the isothermal wall. The typical Biot number at the internal cooling passage of a gas turbine is <0.1, and the use of the rib height as the characteristic length better represents the heat transfer of the rib.


Sign in / Sign up

Export Citation Format

Share Document