scholarly journals Influence of Different Fiber Dosages on the Behaviour of Façade Anchors in High-Performance Concrete

CivilEng ◽  
2021 ◽  
Vol 2 (3) ◽  
pp. 556-579
Author(s):  
Szymon Grzesiak ◽  
Matthias Pahn ◽  
Milan Schultz-Cornelius ◽  
Nora Susanne Bies

The behaviour of façade anchors in high performance fiber reinforced concrete (HPFRC) has not been investigated in sufficient detail in recent years. The regulations in the European Technical Approvals also do not fully describe the load-bearing capacity of anchor systems. Due to the increase in the production of HPFRC elements, it is necessary to analyse the impact of added fibers in the concrete composition on the behaviour of anchors. In particular, the behaviour of anchors in filigree façade elements, which is one of the main application areas of the programme of polypropylene (PP) fiber-reinforced concrete, is therefore analysed. With a sufficient content of PP fibers surrounding the steel anchors oriented in an optimal direction, the fibers may enhance both the load-bearing capacity of anchors and the ductility of concrete. However, unfavourable effects on the installation process or even on the load-bearing capacity may also occur due to unfavourable fiber orientation. Therefore, tensile and punching tests were carried out in uncracked concrete with different types of anchor systems containing a tension anchor and an adjustable spacer bolt. The PP fiber content of the concrete component varied during the tests.

Buildings ◽  
2021 ◽  
Vol 11 (2) ◽  
pp. 63
Author(s):  
Anna L. Mina ◽  
Michael F. Petrou ◽  
Konstantinos G. Trezos

The scope of this paper is to investigate the performance of ultra-high performance fiber reinforced concrete (UHPFRC) concrete slabs, under projectile impact. Mixture performance under impact loading was examined using bullets with 7.62 mm diameter and initial velocity 800 m/s. The UHPFRC, used in this study, consists of a combination of steel fibers of two lengths: 6 mm and 13 mm with the same diameter of 0.16 mm. Six composition mixtures were tested, four UHPFRC, one ultra-high performance concrete (UHPC), without steel fibers, and high strength concrete (HSC). Slabs with thicknesses of 15, 30, 50, and 70 mm were produced and subjected to real shotgun fire in the field. Penetration depth, material volume loss, and crater diameter were measured and analyzed. The test results show that the mixture with a combination of 3% 6 mm and 3% of 13 mm length of steel fibers exhibited the best resistance to projectile impact and only the slabs with 15 mm thickness had perforation. Empirical models that predict the depth of penetration were compared with the experimental results. This material can be used as an overlay to buildings or to construct small precast structures.


2021 ◽  
Vol 28 (2) ◽  
pp. 54-72
Author(s):  
Abd-al-Salam Al-Hazragi ◽  
Assim Lateef

This article investigates the behaviour of strengthened concrete columns using jacketing ultra-high-performance fiber reinforced concrete (UHPFRC) and carbon fiber-reinforced polymer (CFRP) under uniaxial loaded. The jacket was connected to the column core using shear connectors and (CFRP) fixed as a strip on the tension zone between the column cores and the jacketing. Seven column samples of square cross-section (120 x120) mm at the midsection with overall length of 1250 mm were cast using normal strength concrete (NSC) and having similar longitudinal and transverse reinforcement. The samples were made and tested under axial load at eccentricity equal to 120 mm up to failure. Test parameters were the thickness of jackets (25 and 35) mm and the width of CFRP (0,8, and 12) cm. Column specimens were tested, one of them was reference without any strengthening, and the other specimens divided into two groups (A, and B), and each group included three specimens based on the parameters. Group (A) has UHPFRC jacket thickness 25 mm and CFRP width (0,8, and 12) cm respectively, and group (B) has UHPFRC jacket thickness 35 mm and CFRP width (0,8, and 12) cm respectively. The outcomes of the article show that increasing the thickness of jacket, and width of CFRP lead to increase in the load carrying capacity about (110.5%,168.4%, and 184.2%) for group A, and (157.9%,226.3%, and 263.2%) for group B compared with the reference column due to delay in the appearance of cracks and their distribution. The mid-height lateral displacement of columns was decreased about (66.6%,42.3%, and 35.9%) for group A, and (46.15%,38.46%, and 32.3%) for group B, also the axial deformation of specimens decreased about (71.7%,60.86%, and 55.86%) for group A, and (65.5%,60.5%, and 53.4) for group B compared with the reference column. The ductility of columns that were strengthened with UHPFRC jacket only was increased about (13.67%,19.66%) for thickness(25,35) mm respectively, because of that UHPFRC jacket was contented on steel fibers, and the percentage decrease of ductility was about (5.1%,and 12%) for group (A), (1%,and 9.4%) for group (B) when bonded CFRP in the tension zone with width (8 ,and 12) cm respectively. The results show improvement in the initial and secant stiffness when, increased the thickness of jacket, and width of CFRP because of increase in the size of columns and improvement in the modulus of elasticity. The toughness increase was about (273.97%,301.55%, and 304.5%) for group A, and (453.69%,511.93%, and 524.28%) for group B compared with the reference column because of increase in the size of specimens and delay the appearance of cracks.


2014 ◽  
Vol 982 ◽  
pp. 119-124 ◽  
Author(s):  
Tomáš Vavřiník ◽  
Jan Zatloukal

This paper describes influence of different mechanical properties to the concrete penetration resistance. The resistance is evaluated on the basis of the presented experimental program. In the experiment, non-deformable ogive-nose projectiles with diameter of 7.92 mm and mass of 8 g with impact velocity of about 700 m/s were hitting center of the specimens. Determination of the concrete penetration resistance was than based on projectile residual velocity obtained from high-speed camera record. The specimens were made from high strength concrete, steel fiber-reinforced concrete, ultra-high performance concrete and ultra-high performance fiber-reinforced concrete with different fiber content. The concrete penetration resistance was evaluated on total 32 specimens. Influence of mechanical properties, addition of coarse aggregate and steel fibers were discussed. Mechanical properties of the tested materials were investigated on total 125 specimens. Data from the measurements were used for creation of new RHT concrete models in Autodyn. In order to confirm experiment's setup and results, numerical analysis was performed in Autodyn. Results of the numerical simulations were compared to the experimental program.


2014 ◽  
Vol 624 ◽  
pp. 246-253
Author(s):  
Michal Přinosil ◽  
Petr Kabele

Out of plane load bearing capacity of a masonry structure enhanced by surface render made of high performance lime-based mortar is investigated by numerical simulations using the finite element method (FEM). The response of the wall is simulated firstly without render (as a reference) then with surface render consisting of conventional lime mortar with increased tensile strength (by addition of the metakaolin) without fibers and finally with the proposed lime-metakaolin mortar reinforced with PVA fibers. The thickness of the surface render is considered in two configurations (20 mm and 40 mm). Material parameters of masonry units (bricks), joints (mortar between bricks) and conventional plain render are chosen with regard to investigations of historic structures (reported in the literature), material characteristics of fiber reinforced render are evaluated based on experiments or numerical simulations of these experiments. Using these parameters and characteristics, the numerical simulations of masonry wall subjected to out of plane bending are performed. The results allow us to identify influence of the thickness and the material of render on load-bearing and deformation capacity, failure mode and amount and width of cracks. The results show that the conventional plain mortar improves load-bearing capacity and deformation capacity proportionately to the thickness of render, but the response remains brittle. Fiber reinforced mortar significantly increases the deformation capacity and load-bearing capacity and the amount of absorbed energy is significantly improved.


Materials ◽  
2020 ◽  
Vol 13 (24) ◽  
pp. 5603
Author(s):  
Sun-Jae Yoo ◽  
Tian-Feng Yuan ◽  
Se-Hee Hong ◽  
Young-Soo Yoon

In this study, the performance of reinforced concrete slabs strengthened using four methods was investigated under impact loads transferred from the top side to bottom side. The top and bottom sides of test slabs were strengthened by no-slump high-strength, high-ductility concrete (NSHSDC), fiber-reinforced-polymer (FRP) sheet, and sprayed FRP, respectively. The test results indicated that the test specimens strengthened with FRP series showed a 4% increase in reaction force and a decrease in deflection by more than 20% compared to the non-strengthened specimens. However, the specimen enhanced by the NSHSDC jacket at both the top and bottom sides exhibited the highest reaction force and energy dissipation as well as the above measurements because it contains two types of fibers in the NSHSDC. In addition, the weight loss rate was improved by approximately 0.12% for the NSHSDC specimen, which was the lowest among the specimens when measuring the weight before and after the impact load. Therefore, a linear relationship between the top and bottom strengthening of the NSHSDC and the impact resistance was confirmed, concluding that the NSHSDC is effective for impact resistance when the top and bottom sides are strengthened. The results of the analysis of the existing research show that the NSHSDC is considered to have high impact resistance, even though it has lower resistance than the steel fiber reinforced concrete and ultra-high-performance-concrete, it can be expected to further studies on strengthening of NSHSDC.


2019 ◽  
Vol 10 (1) ◽  
pp. 239
Author(s):  
Ana Martínez-Ibernón ◽  
Marta Roig-Flores ◽  
Josep Lliso-Ferrando ◽  
Eduardo J. Mezquida-Alcaraz ◽  
Manuel Valcuende ◽  
...  

Reinforced concrete elements frequently suffer small cracks that are not relevant from the mechanical point of view, but they can be an entrance point for aggressive agents, such as oxygen, which could initiate the degradation processes. Fiber-Reinforced Concrete and especially Ultra High Performance Concrete increase the multi-cracking behavior, reducing the crack width and spacing. In this work, the oxygen availability of three types of concrete was compared at similar strain levels to evaluate the benefit of multi-cracking in the transport of oxygen. The types of concrete studied include traditional, High-Performance, and Ultra-High-Performance Fiber-Reinforced Concrete with and without nanofibers. To this purpose, reinforced concrete beams sized 150 × 100 × 750 mm3 were prepared with embedded stainless steel sensors that were located at three heights, which have also been validated through this work. These beams were pre-cracked in bending up to fixed strain levels. The results indicate that the sensors used were able to detect oxygen availability due to the presence of cracks and the detected differences between the studied concretes. Ultra High Performance Concrete in the cracked state displayed lower oxygen availability than the uncracked High Performance Concrete, demonstrating its potential higher durability, even when working in cracked state, thanks to the increased multi-cracking response.


Vestnik MGSU ◽  
2021 ◽  
pp. 1567-1572
Author(s):  
Emmanuel Mikerego ◽  
Donatien Nduwimana

Introduction. This paper presents the results of an assessment of the impact of fire on the bearing capacity of the ordinary concrete, to be taken into account in the rehabilitation of fire-damaged reinforced concrete structures in Burundi. Materials and methods. Experimental samples of the ordinary concrete made respectively of coarse river aggregates and crushed coarse quarry aggregates were prepared and subjected to different heating temperatures (250, 350, 450, 600 and 900 °C) simulating the fire. After natural cooling, experimental samples were subjected to compression test; and diagrams showing the loss of the load-bearing capacity of the ordinary concrete used in reinforced concrete structures in Burundi were drawn. Results. Negative impact of the fire on the load-bearing capacity of the ordinary concrete occurs above of 350 °C of heating temperature. Concrete made of crushed coarse quarry aggregates loses 50 and 78 % of its bearing capacity at around 525 and 900 °C of heating temperature, respectively. Similarly, concrete made of coarse river aggregates loses 50 and 70 % of its load-bearing capacity respectively at 600 and 900 °C of heating temperature. An evaluation curve of the after-fire bea­ring capacity of the concrete used in reinforced concrete structures in Burundi is established. Conclusions. The negative impact of the fire on the load-bearing capacity of the ordinary concrete occurs above of 350 °C of heating temperature. Concretes made of crushed coarse quarry aggregates and concrete made of coarse river aggregates lose 50 % of its bearing capacity at around 525 and 600 °C of heating temperature respectively. Knowing the heating temperature that the fire-damaged reinforced concrete structure has undergone is indispensable in deciding on its demolition or rehabilitation.


Sign in / Sign up

Export Citation Format

Share Document