scholarly journals HPLC with Fluorescence Detection for Determination of Bisphenol A in Canned Vegetables: Optimization, Validation and Application to Samples from Portuguese and Spanish Markets

Coatings ◽  
2020 ◽  
Vol 10 (7) ◽  
pp. 624
Author(s):  
Fernanda Vilarinho ◽  
Antia Lestido-Cardama ◽  
Raquel Sendón ◽  
Ana Rodríguez Bernaldo de Quirós ◽  
Maria de Fátima Vaz ◽  
...  

Bisphenol A (BPA) is one of the chemicals used to produce both polycarbonate plastics and epoxy resin coatings. Research has shown that small amounts of BPA can migrate into the foods and beverages enclosed in these types of containers. In this research, an analytical method based on high-performance liquid chromatography with fluorescence detection (HPLC-FLD) was developed and validated for the determination of BPA in canned vegetables. The results were confirmed by liquid chromatography coupled to tandem mass spectrometry (LC-MS/MS). Attenuated total reflectance Fourier transform infrared spectroscopy (ATR-FTIR) was performed, to identify the coating material of each tin can. Nineteen cans of vegetables were taken as study samples (eleven samples from the Spanish market, and eight samples from the Portuguese market). Excellent linear correlation (r2 = 0.9999) was observed over the range of 0.01 to 0.25 mg/L. Limit of detection (LOD) and limit of quantification (LOQ) values were calculated to be 0.005 mg/kg and 0.01 mg/kg, respectively. Good recoveries, between 72% and 90% were obtained at three different levels of concentration (RSD% = 4.6). BPA was not detected in the samples. The proposed HPLC-FLD was found to be suitable for the determination of BPA in canned vegetables.

2016 ◽  
Vol 19 (3) ◽  
pp. 559-565 ◽  
Author(s):  
E. Kowalczyk ◽  
E. Patyra ◽  
A. Grelik ◽  
K. Kwiatek

Abstract A high performance liquid chromatography combined with fluorescence detection (HPLC-FLD) method was developed for determination of five ergot alkaloids (EA): ergometrine, ergotamine, ergocornine, ergocrypine and ergocristine in animal feedingstuffs. The method was based on the application of QuEChERS salts for extraction and modified QuEChERS dispersive SPE for the cleanup step. Alkaloids separation was performed on a C18, 250 mm x 4.6 mm, 5 μm column with the mobile phase containing ammonium carbonate and acetonitrile. The excitation and emission wavelengths were 330 and 420 nm respectively. The method was validated according to the Commission Decision 2002/657/EC and all parameters are in agreement with the requirements of the Decision. Linearity was determined for the concentration range of 25-400 μg/kg. The coefficient of determination (R2) for all curves was from 0.985 to 0.996. The limit of detection (LOD) was in the range 3.23 to 6.53 μg/kg and the limit of quantification (LOQ) from 11.78 to 13.06 μg/kg. The decision limit (CCα) ranged from 29.56 to 43.08 μg/kg and detection capability (CCβ) from 40.65 to 51.01 μg/kg. The highest coefficient of variation (CV) for repeatability was 14.3% and for reproducibility 15.4%.


Author(s):  
Biljana Stojanovska-Dimzoska ◽  
Zehra Hajrulai-Musliu ◽  
Elizabeta Dimitrieska-Stojkovic ◽  
Risto Uzunov ◽  
Pavle Sekulovski

Liquid chromatography with fluorescence detection using immunoaffinity column clean-up was a method described for determination of aflatoxins (AFB1, AFB2, AFG1 and AFG2) in peanuts and peanut based products. The validation of the procedure was performed. Good coefficient of correlation was found for all aflatoxins in the range of 0.9993-0.9999. Limit of detection (LOD) and limit of quantification (LOQ) ranged from 0.003-0.005 mg/kg and 0.009-0.023 mg/kg, respectively, which was acceptable. The mean recovery for total aflatoxins was 88.21%. The method also showed acceptable precision values in the range of 0.171-2.626% at proposed concentration levels for all four aflatoxins. RSDR values (within laboratory reproducibility) calculated from the results showed good correlation between two analysts for all aflatoxins and they ranged from 4.93-11.87%. The developed method was applied for the determination of aflatoxins in 27 samples of peanuts and peanut based products. The results showed that 21 peanut samples (77.7%) were below LOD of the method. Three samples had positive results over the MRL. There was one extreme value recorded for the total aflatoxins in peanut (289.2 mg/kg) and two peanut based products, peanut snack and peanut, with total content of aflatoxins being 16.3 mg/kg and 8.0 mg/kg, respectively. The obtained results demonstrated that the procedure was suitable for the de?termination of aflatoxins in peanuts and peanut based products and it could be implemented for the routine analysis.


2019 ◽  
Vol 9 (1) ◽  
Author(s):  
Hui Yan ◽  
Zhuan-Di Zheng ◽  
Hong-Fei Wu ◽  
Xiao-Chuang Liu ◽  
An Zhou

AbstractTenuifolin was used as a reliable chemical marker for the quality control of Radix Polygalae. The determination of tenuifolin is challenging because the analyte molecule lacks a suitable chromophore. The aim of this study was to establish a microemulsion high-performance liquid chromatography (MELC) method which is robust and sensitive, and can separate and determine tenuifolin in Radix Polygalae using an oil-in-water (O/W) microemulsion mobile phase. The separations were performed on a C18 (4.6 × 250 mm, 5 μm) column at 25 °C using a flow rate of 1.0 mL/min, and an ultraviolet detection wavelength of 210 nm. The microemulsion mobile phase comprised 2.8% (w/v) sodium dodecyl sulfate (SDS), 7.0% (v/v) n-butanol, 0.8% (v/v) n-octane and 0.1% (v/v) aqueous orthophosphate buffer (H3PO4). The linearity analysis of tenuifolin showed a correlation coefficient of 0.9923 in the concentration range of 48.00–960.00 µg/mL. The accuracy of the method based on three concentration levels ranged from 96.23% to 99.28%; the limit of detection (LOD) was 2.34 µg/mL, and the limit of quantification (LOQ) was 6.76 µg/mL. The results of our study indicated that the optimized MELC method was sensitive and robust, and can be widely applied for the separation and determination of tenuifolin in Radix Polygalae.


2019 ◽  
Vol 2019 ◽  
pp. 1-6
Author(s):  
Ruth Rodriguez ◽  
Elianna Castillo ◽  
Diana Sinuco

A simple and economic high-performance liquid chromatography (HPLC-UV-Vis) analytical method was validated for the quantitation of specific Bisphenol-A migration from baby feeding bottles. Overall and specific migration assays were done with different food simulating matrices using the filling method. Good linearity was obtained over the concentration range of 0.01–0.6 mg/kg. The limit of detection (LOD) and limit of quantification (LOQ) were 0.004 and 0.010 mg/kg, respectively. The repeatability of the method (%RSD, n=10) was between 89.5 and 99.0%, while recovery ranged from 83.2 to 98.4%. The method was applied to specific migration assays from baby feeding bottles purchased from different plastic producers in Colombia. The results show that, in a first migration assay, Bisphenol-A was not detectable in all samples. In a second migration test, Bisphenol-A concentrations were higher than the most restricted limit (0.05 mg/kg) with ethanol 95% and isooctane as food simulants.


2001 ◽  
Vol 18 (1) ◽  
pp. 69-75 ◽  
Author(s):  
Terumitsu Yoshida ◽  
Masakazu Horie ◽  
Youji Hoshino ◽  
Hiroyuki Nakazawa ◽  
Masakazu Horie ◽  
...  

2013 ◽  
Vol 2013 ◽  
pp. 1-6 ◽  
Author(s):  
Naghi Saadatjou ◽  
Shahab Shariati ◽  
Mostafa Golshekan

A simple and high sensitive preconcentration method based on micelle-mediated extraction followed by high performance liquid chromatography (LC-UV) was developed for preconcentration and determination of trace amounts of bisphenol A (BPA) in aqueous samples. The BPA was quantitatively extracted from aqueous samples in the presence of Triton X-114 as a nonionic surfactant and preconcentrated into the small volume (about 30 μL) of the surfactant-rich phase. Taguchi method, an orthogonal array design (OA16 (45)), was utilized to optimize the various factors affecting the micellar extraction of BPA. The maximum extraction efficiency of BPA was obtained at pH 3, 0.2% (w/v) Triton X-114, and 0.25 mol L−1 sodium acetate. For the preconcentration, the solutions were incubated in a thermostatic water bath at 50°C for 7 min. After centrifuge and separation of aqueous phase, the surfactant-rich phase was diluted with 100 μL acetone and injected in the chromatographic system. Under the optimum conditions, preconcentration factor of 34.9 was achieved for extraction from 10 mL of sample solution and the relative standard deviation (RSD%) of the method was lower than 6.6%. The calibration curve was linear in the range of 0.5–150 μg L−1 with reasonable linearity (r2>0.9987). The limit of detection (LOD) based on S/N = 3 was 0.13 μg L−1 for 10 mL sample volumes. The limit of quantification (LOQ) based on S/N = 10 was 0.43 μg L−1 for 10 mL sample volumes. Finally, the applicability of the proposed method was evaluated by the extraction and determination of BPA in the real samples, and satisfactory results were obtained.


2020 ◽  
Vol 8 (2) ◽  
pp. 1-7
Author(s):  
Ihsan M. Shaheed ◽  
Saadiyah A. Dhahir

The quinolizindine alkaloid compound, oxymatrine pesticide, was analysis in the river water samples collected from different agriculture areas in the Iraqi city of Kerbala and also in its formulation using developed reverse-phase high-performance liquid chromatography method. Acetonitrile:methanol (60:40 v/v) was chosen as mobile phase at pH (7.0), flow rate 0.5 mL/min, and 20 µL as volume injection. Modified ecological-friendly method, dispersive liquid-liquid microextraction, was used for the extraction of oxymatrine from water samples. Linearity study was constructed from 0.1 to 70 μg/mL at λmax 205 nm. The limit of detection and limit of quantification were 0.025 and 0.082 μg/mL, respectively, and the relative standard deviation (RSD) % was 0.518%. Three spiked levels of concentration (20.0, 40.0, and 70.0 μg/mL) were used for the validation method. The percentage recovery for the three spiked samples was ranged between 98.743 and 99.432 and the RSD% was between 0.051 and 0.202%, the formulation studies of oxymatrine between 99.487 and 99.798, and the RSD% was ranged from 0.045 to 0.057%. The developed method can be used accurately and selectively for the determination of oxymatrine in environmental samples and in the formulation.


2020 ◽  
Vol 17 (34) ◽  
pp. 1046-1054
Author(s):  
Ihsan Mahdi SHAHEED ◽  
Saadiyah Ahmed DHAHIR

The triazole, tebuconazole pesticide, was determined in its formulation and also in the river water samples collected from different agriculture areas in the Iraqui city of Kerbala using developed high-performance liquid chromatography method(HPLC) with UV-visible detection, The mobile composition phase was a mixture of acetonitrile:methanol (50:50 v/v) and the column was C18 (250 cm x 4.6 mm,5μm). Also modified dispersive liquidliquid microextraction (DLLME), which is regarded as an ecological -friendly method, was used for the extraction of tebuconazole from water samples using acetonitrile and chloroform as solvents extraction and dispersive agent, respectively. Linearity to maintain the calibration curve was achieved from (0.1-70) μg.mL-1 with a limit of detection(0.053) μg.mL-1 and limit of quantification (0.174) μg.mL-1. Three spiked levels of concentration (1.0, 5.0, and 10) μg.mL-1 were used for the validation of the method. The relative standard deviation (RSD%) was (0.294- 0.813)%, and the percentage recovery was (100.001-100.005). The formulation studies for two different concentrations (10 and 40) μg.mL-1, which prepared from tebuconazole formulation (Raxil ODS2 2%), gave acceptable percentage recovery between (98.956-99.833). The developed method can be used accurately for the determination of tebuconazole in water samples and in the formulation of tebuconazole effectively.


Sign in / Sign up

Export Citation Format

Share Document