Performance of a Noninvasive Magnetic Sensor-Based Current Measurement System in Power Systems

Electronics ◽  
2021 ◽  
Vol 10 (22) ◽  
pp. 2869
Author(s):  
Prasad Shrawane ◽  
Tarlochan S. Sidhu

A large increase in distributed generation integrated within power system networks has resulted in power quality challenges and in the need to resolve complex system faults. The monitoring of the real-time state of the power parameters of the transmission and distribution grid helps to control the stability and reliability of the grid. In such a scenario, having current monitoring equipment that is flexible and easy to install can always be of great help to reduce the price of energy monitoring and to increase the dependability of a smart grid. Advances in magnetic sensor research offer measurement system accuracy that is less complex to install and that can be obtained at a lower less cost. Tunneling magnetoresistive (TMR) sensors can be used to measure the AC current by sensing the magnetic field that is generated by the current-carrying conductor in a contactless manner. This paper illustrates the results of a thorough investigation of factors that can influence the performance of the TMR sensors that are used for the current phasor measurements of a single-phase AC current application, such as the effects of distance, harmonics, and conductor insulation.

Energies ◽  
2021 ◽  
Vol 14 (14) ◽  
pp. 4150
Author(s):  
Lluís Monjo ◽  
Luis Sainz ◽  
Juan José Mesas ◽  
Joaquín Pedra

Photovoltaic (PV) power systems are increasingly being used as renewable power generation sources. Quasi-Z-source inverters (qZSI) are a recent, high-potential technology that can be used to integrate PV power systems into AC networks. Simultaneously, concerns regarding the stability of PV power systems are increasing. Converters reduce the damping of grid-connected converter systems, leading to instability. Several studies have analyzed the stability and dynamics of qZSI, although the characterization of qZSI-PV system dynamics in order to study transient interactions and stability has not yet been properly completed. This paper contributes a small-signal, state-space-averaged model of qZSI-PV systems in order to study these issues. The model is also applied to investigate the stability of PV power systems by analyzing the influence of system parameters. Moreover, solutions to mitigate the instabilities are proposed and the stability is verified using PSCAD time domain simulations.


Energies ◽  
2021 ◽  
Vol 14 (2) ◽  
pp. 513
Author(s):  
Henryk Majchrzak ◽  
Michał Kozioł

The balancing of the power of the Polish Power System (KSE) is a key element in ensuring the safety of electric energy supplies to end users. This article presents an analysis of the power demand in power systems (PS), with emphasis on the typical power variability both in subsequent hours of the day and on particular days and in particular months each year. The methodology for calculating the costs of electric energy undelivered to the end users and the amount of these costs for KSE is presented. Different possibilities have been analyzed for balancing power systems’ peak load and assumptions have been formulated for calculating the amount of the related costs. On this basis, a comparative analysis has been made of the possibility to balance peak load using operators’ system services, trans-border connections, and various energy storage solutions. On the basis of the obtained results, optimal tools have been proposed for market-based influence from transmission and distribution system operators on energy market participants’ behaviors in order to ensure the power systems’ operating safety and continuous energy deliveries to end users.


Energies ◽  
2021 ◽  
Vol 14 (1) ◽  
pp. 195
Author(s):  
Ivan Oropeza-Perez ◽  
Astrid H Petzold-Rodriguez

The Mexican national electricity transmission and distribution grid (SEN, initials in Spanish) is characterized by the high interconnection between its several electricity generation plants and the millions of final consumers throughout the country. This feature, which is seen first as an adequate transmission and distribution method for electricity between producer and consumer, has the inconvenience of being highly complex when renewable energy is introduced into the SEN. The random nature of renewable energy means that coordination between the producer and consumer is difficult; therefore, these energy sources are considered by the Mexican Federal Commission of Electricity (CFE, initials in Spanish) without priority in their generation and distribution. In this document, a solution for this is given by the consideration of on-site photovoltaic production in the Mexican residential sector, setting a straightforward relationship between production and consumption, neglecting the long-distance transmission, and freeing the transmission and distribution through the SEN at certain hours of the day. Different scenarios are studied, considering the level of penetration of this renewable energy technology into the housing sector. In this way, it is found that, if 80% of the total Mexican dwellings hold a photovoltaic roof, in some seasons of the year, a large part the total national demand can be fulfilled by the photovoltaic generation if certain systems—such as bidirectional smart meters—are applied. In this sense, the results show that, if 80% of the Mexican dwellings had a photovoltaic roof, there would be a money saving of 3418 Million USD and a mitigation of 25 million tons CO2e, for 2018. With this, it is concluded that renewable energy in Mexico could provide a much greater share if the electricity is produced in the same place where it will be consumed. This might be possible in Mexico due to the high interconnection of the transmission and distribution grid, which would manage the surplus electricity generation in the dwellings in a proper manner.


1987 ◽  
Vol 20 (1) ◽  
pp. 18-25
Author(s):  
P Gilbert

The transmission and distribution system operated by British Gas plc is the largest integrated pipeline system in Europe. The whole system comprises a national transmission system which carries gas from five terminals to the twelve gas regions. Each region in turn carries the gas through a regional transmission system into a distribution grid and thence onto its customers. The national, regional and distribution system all present the instrument engineer with different technical challenges because of the way in which they have been built and are operated, however, it is simplest to characterise them by their process conditions. The operating pressure is highest in the national transmission system being up to 75 bar, in the regional transmission system the pressure is usually less than 37 bar, and in the distribution grid it is less than 7 bar. In general, the pipe diameters decrease from the national system downwards, and the measured flowrates are lowest in the distribution grids. This paper is concerned only with instrumentation on the national transmission system. The discussion will cover current technology which is typical of that being installed at present, and concentrates on the more commonly found instrumentation. The paper begins with a brief history of development of the national transmission system and a description of how it is operated. This is followed by a discussion on the application of computers to the control of unmanned installations. A section concerning the measurement of pressure and its application to the control of the system comes next. The main part of the paper contains an analysis of high accuracy flowmetering and the paper concludes with some comments on developments in instrumentation and their application to changing operation of the national transmission system.


2019 ◽  
Vol 2 (S1) ◽  
Author(s):  
Friederike Wenderoth ◽  
Elisabeth Drayer ◽  
Robert Schmoll ◽  
Michael Niedermeier ◽  
Martin Braun

Abstract Historically, the power distribution grid was a passive system with limited control capabilities. Due to its increasing digitalization, this paradigm has shifted: the passive architecture of the power system itself, which includes cables, lines, and transformers, is extended by a communication infrastructure to become an active distribution grid. This transformation to an active system results from control capabilities that combine the communication and the physical components of the grid. It aims at optimizing, securing, enhancing, or facilitating the power system operation. The combination of power system, communication, and control capabilities is also referred to as a “smart grid”. A multitude of different architectures exist to realize such integrated systems. They are often labeled with descriptive terms such as “distributed,” “decentralized,” “local,” or “central." However, the actual meaning of these terms varies considerably within the research community.This paper illustrates the conflicting uses of prominent classification terms for the description of smart grid architectures. One source of this inconsistency is that the development of such interconnected systems is not only in the hands of classic power engineering but requires input from neighboring research disciplines such as control theory and automation, information and telecommunication technology, and electronics. This impedes a clear classification of smart grid solutions. Furthermore, this paper proposes a set of well-defined operation architectures specialized for use in power systems. Based on these architectures, this paper defines clear classifiers for the assessment of smart grid solutions. This allows the structural classification and comparison between different smart grid solutions and promotes a mutual understanding between the research disciplines. This paper presents revised parts of Chapters 4.2 and 5.2 of the dissertation of Drayer (Resilient Operation of Distribution Grids with Distributed-Hierarchical Architecture. Energy Management and Power System Operation, vol. 6, 2018).


2020 ◽  
Vol 20 (4) ◽  
pp. 103-113

A synchronous generator is one of the key elements of any power system, having a significant impact on the stability and reliability of consumers’ power supply. Nowadays, the power systems emergency and operational control issues are being solved using computational models, the parameters whereof are determined using the reference data, or the data obtained during testing. High dependence of the models’ parameters on various external factors leads to a significant decrease in the accuracy of solving the issues of emergency and operational control. Identification based on the traditional telemetry systems or synchrophasor measurements is used to improve the accuracy of parameters of the power systems’ computational models. The purpose of this research lies in a meta-analysis of the available studies aimed at developing a methodology for determining parameters of a synchronous generator on the basis of measurement data. Russian and foreign studies were analyzed and grouped to achieve this goal. After that, for each group, advantages, disadvantages, and the area of application were identified. As a result, it is shown that the existing methods for determining parameters of synchronous generators based on measurement data cannot adapt to the source dataset and also require significant computing power. As a way to overcome these shortcomings, an adaptive model of a synchronous machine is proposed.


The article dwells upon optimizing, reduction of losses in, and improving the stability of grids by implementing devices that affect the parameters and power flows in a grid. State-of-the-art technology for better control is crucial for the development of electric power systems. FACTS technologies or flexible alternating current transmission systems, essentially transform the grid from a passive electricity transport into a device that actively controls the grid parameters. The article analyzes the development of a 500/220/110 kV grid that uses parameter-affective devices: SVC, BSK, LCD. Steady-state parameters, active power losses, and electric power losses were calculated for a year before and after the devices were deployed. Each device was therefore analyzed for effectiveness. The parameters of the SVC-equipped 500/220/110 kV grid were calculated for emergency operation with the 500 kV line being offline. Thus, the paper also analyzes the emergency performance of the SVC.